    Operation Husky ® 1050 Air -Operated Diaphra gm Pump 312877P EN 1-inch pump with modular air v al ve for fluid transf er applications. For prof essional use only . See page 4 f or model inf ormation, including appr o v als. 125 psi (0.86 MP a, 8.6 bar) Ma ximum Fluid W or king Pressure 125 psi (0.86 MP a, 8.6 bar) Maximum Air Input Pressure End Fl ...

  • Graco 1050A - page 2

    Related Manua ls 2 312877P Contents Related M anuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 T o Find Y our N earest Distributor . . . . . . . . . . . . . . 3 T o Specif y the Configurat ion of a Ne w Pump . . . . 3 T o Order Replacement P ar ts . . . . . . . . . . . . . . . . . 3 Distributor Note . . . . . . . . . . . . . . . . . . ...

  • Graco 1050A - page 3

    To Find Your Nearest D istributor 312877P 3 T o Find Y our Nearest Distrib utor 1. Visit www .graco .com . 2. Click on Where to Buy and use the Distributor Locator . T o Specify the Configuration of a Ne w Pump Please call y our distributor . OR 1. Use the Online Husky Sel ector T ool at wwwd.graco .com/training/husky/inde x.html. 2. If the link do ...

  • Graco 1050A - page 4

    Configuration Numb er Matrix 4 312877P Configuration Number Matrix Chec k the identification plate (ID) f or the 20-digit Configuration Number of y our pump . Use the follo wing matrix to define the components of y our pump . Sample Configuration Number 1050A A01A A1 SS BN BN PT Pump Model Center Section and Air V al ve Fluid Cov ers and Manif olds ...

  • Graco 1050A - page 5

    ATEX Certifications 312877P 5 A TEX Cer tifications Wa r n i n g s The f ollowing w arnings are for the setup , use, grounding, maintenance , and repair of this equip- ment. The e xclamation point symbo l aler ts you to a gener al warni ng and the hazard symbol refe rs to procedure-specific risk. When these symbols appear in the body of this manual ...

  • Graco 1050A - page 6

    Warnings 6 312877P SPECIAL CONDITIONS FOR SAFE USE Equipment must comply with the f ollowing conditions to av oid a hazardous condition which can cause fire or e xplosion. • All label and marking mater i al must be cleaned with a damp cloth (or equiv alent). • The electronic monitori ng system is requir ed to be grounded. See Gr ounding instruc ...

  • Graco 1050A - page 7

    Installation 312877P 7 Installation The T ypical Installation shown in F IG . 4 is only a guide f or selecting and installing system components. Contact y our Graco distr ibutor f or assistance in planning a system to suit your needs. Tighten F astener s Bef ore Setup Bef ore using the pump f o r the first time , chec k and retorque all e xter nal ...

  • Graco 1050A - page 8

    Installation 8 312877P Mounting 1. F or wall mounting, or der Graco Kit 24C637. 2. Be sure the mounti ng surface can support the weight of the pum p , hoses, and acces- sories, as well as the stress caused during operation. 3. F or all mountings, be sure the pump is bolted directly to the mounting surf ace . 4. F or ease of operati on and service, ...

  • Graco 1050A - page 9

    Installation 312877P 9 Check y our system electr ical continuity after the initial installation, and then set up a regular schedule f or chec king continuity to be sure proper grounding is maintained. Air Line See F IG . 4, page 12. 1. Install an air regulat or (C) and gauge to control the fluid pre ssure. The fluid stall pressure will be the same ...

  • Graco 1050A - page 10

    Installation 10 312877P Air Exhaust V entilation The air e xhaust por t is 3/4 npt(f). Do not restrict the air exhaust por t. Excessiv e e xhaust restriction can cause er ratic pump operation. T o pro vide a remote exhaust: 1. Remov e the muffler (T) from the pump air e xhaust por t. 2. Install a grounded air e xhaust hose (U) and connect the muffl ...

  • Graco 1050A - page 11

    Installation 312877P 11 Fluid Suppl y Line See F IG . 4, page 12. 1. Use grounded, fle xible fluid supply lines (G). See Grounding , page 8. 2. If the inlet fluid pre ssure to the pump is more than 25% of t he outlet working pres- sure, the ball chec k v alv es will not close f ast enough, resulting in inefficient pump operation. Excessiv e in let ...

  • Graco 1050A - page 12

    Installation 12 312877P Key fo r F IG . 4: A Air supply line B Bleed-type master air v alve (requ ired f or pump) C Air filter/regulator assemb ly D Air inlet E Master air v alve (f or accessor ies) G Grounded, fle xible fluid sup ply line J Fluid drain v alve (required) K Fluid shutoff v alve L Grounded, fle xib le fluid outlet line M Fluid inlet ...

  • Graco 1050A - page 13

    Installation 312877P 13 Fluid Inlet and Outlet P or ts NO TE: Remov e and rev erse the manifold(s) to change the orientation of in let or outlet por t(s). Fo l l o w T orque Instructions on page 17. Aluminum ( 1050A ) The fluid inlet and outle t manif olds each hav e f our 1 in. npt(f) or bspt threaded por ts. Close off the unused por ts, using the ...

  • Graco 1050A - page 14

    Installation 14 312877P Fluid Pressure Relief V alve F IG . 6. Fluid pressure relief kit (Aluminum pumps only , 1050A models) Some systems ma y requi re installation of a pressure relief v alv e at the pump outlet to pre- v ent ov er pressurization and rupture of the pump or hose. Ther mal e xpansion of flui d in the outlet line can cause ov er pre ...

  • Graco 1050A - page 15

    Operation 312877P 15 Operation Pressure Relief Pr ocedure 1. Shut off the air supply to the pump . 2. Open the dispensing valv e, if used. 3. Open the fluid drain v alv e to relie v e fluid pressure. Ha v e a cont ainer ready to catch the drainage . Flush the Pump Bef ore Fir st Use The pump was tested in w ater . If water could contaminate the flu ...

  • Graco 1050A - page 16

    Maintenance 16 312877P 10. If you are flushi ng, run the pump long enough to thoroughly clean the pump and hoses. 11. Close the dispensing valv e, if used. 12. Close the bleed-ty pe master air v alve. 13. Pumps with r una wa y protection: Disab le the prime/flush func tion by pushing the prime/flush button on the DataT r ak. DataT rak Operation See ...

  • Graco 1050A - page 17

    Maintenance 312877P 17 T orque Instructions NO TE: Fluid cov er and manif old f asteners hav e a thread-locking adhesiv e patch applied to the threads. If this patch is e xcessively w or n, the f asteners ma y l oosen during operation. Replace screws with ne w ones or apply medium-strength (b lue) Lo ctite or equiv alent to the threads. If fluid co ...

  • Graco 1050A - page 18

    Dimensions and Mounting 18 312877P Dimensions and Mounting Aluminum ( 1050A ) 5.0 in. 5.5 in. (140 mm) (127 mm) K J H & % E A 1 0 3 / G F D ti12212b ti12211b ti12213b ti14540b A ..... 12.7 in. (323 mm) B ..... 14.4 in. (366 mm) C ..... 15.9 in. (404 mm) D ..... 10.9 in. (277 mm) E...... 1.8 in. (46 mm) F ...... 7.3 in. (185 mm) G ..... 14.7 in. ...

  • Graco 1050A - page 19

    Dimensions a nd Mounting 312877P 19 P olypr opylene ( 1050P ), Conductive P ol ypr opylene ( 1050C ) and PVDF ( 1050F ) NO TE: Listed dimensions are accurate f or both center and end fl ange models, e xcept where noted. & % ( $ 1 0 3 . - + LQ PP LQ PP * ) ' / ti13845b ti1 ...

  • Graco 1050A - page 20

    Dimensions and Mounting 20 312877P Hastello y ( 1050H ) and Stainless Steel ( 1050S ) & ( % $ 1 0 3 * ' / . - + LQ PP LQ PP ti14343b ti14344b ti14345b ti14542b A ..... 11.8 in. (300 mm) B ..... 12.9 in. (328 mm) C ..... 13.7 in. (348 mm) D ..... 9.5 in. (24 1 mm) E...... 1.1 ...

  • Graco 1050A - page 21

    Performance Charts 312877P 21 Pe r f o r m a n c e C h a r t s T est Conditions: Pump tested i n wate r with inlet submerged. 0 51 0 15 20 25 30 35 40 45 50 (19) (38) (57) (76) (95) (114) (133) (152) (170) (189) A B C D How to Read the Charts 1. Locate fluid flo w ra te along bottom of chart. 2. Follo w ve r tical line up to intersection with selec ...

  • Graco 1050A - page 22

    Technica l Data 22 312877P T e c hnical Data Maximum fluid wo rking p ressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 psi (0.8 6 MP a, 8.6 bar ) Air pressure o perating range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-125 psi (0.14-0.86 MP a , 1.4-8. 6 bar) Fluid displacem ent per cycle ...

  • Graco 1050A - page 23

    Technical Data 312877P 23 * Sound po wer m easured per I SO-9614-2. ** Sound pressure w as tested 3.28 ft (1 m) from equip ment. All trademar ks mentione d in this manual are the prope r ty of th eir respective owners. Fluid T emperature Range * The maxim um temper ature listed is based on the A TEX standard for T4 temperature classification. If yo ...

  • Graco 1050A - page 24

    All written and visual data contained in this document reflects the latest product information available at the time of publica tion. Graco reserves the right to make changes a t any time without notice. Original instructi ons. This manual contains English. MM 312877 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Kore ...

Fabricante Graco Categoría Water Pump

Los documentos del dispositivo Graco 1050A que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Graco
- manuales de instrucciones 1050A
- hojas de producto Graco
- folletos informativos
- o etiquetas energéticas Graco 1050A
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Graco 1050A.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Graco 1050A, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Graco 1050A. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Graco 1050A.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Graco 1050A, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Graco 1050A. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Graco 1050A.

El manual de instrucciones completo de Graco debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Graco 1050A - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Graco 1050A, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Graco 1050A que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Graco 1050A - que deben facilitarnos los primeros pasos durante el uso de Graco 1050A
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Graco 1050A
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Graco 1050A en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Graco 1050A?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Graco 1050A, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Graco 1050A probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)