Manual Honeywell NETAXS-123

76 pages 3.28 mb
Download

Go to site of 76

Summary
  • Honeywell NETAXS-123 - page 1

    May 2010 © 2010 Honeywe ll. All rights reserved. 800-05779, Revision A NetAXS-123 Access Control Unit Inst allation Guide ...

  • Honeywell NETAXS-123 - page 2

    Copyright© 2010 Honeywell. All right s reserve d. All product and brand names are the service ma rks, trademarks, registe red trademarks, or registered service marks of their respec tive owners. Printed in the United S tates of America. Honeywell reserves th e right to change an y inform ation in this document at any time without prior notice. Ord ...

  • Honeywell NETAXS-123 - page 3

    NetAXS-123 Access Control Unit Installation Guide , Document 800-0 5779, Revision A iii C ONTENT S Inst alling the NetAXS-123 Panels 1.0 Introductio n ..................... .............. ................. ................. ................. ................. ................. ................. . 2 1.1 Access Control Overview .................... . ...

  • Honeywell NETAXS-123 - page 4

    iv www.honeywell.com 4.3 RS-485 Connection via PCI-3 .................................... ........................... .......................... 50 4.4 RS-485 Connection via NetAXS-123 ................ ........................... ........................... ........ 51 4.5 RS-485 Connections with Multidrop Panels at Both Ends of the Cable ......... ...

  • Honeywell NETAXS-123 - page 5

    NetAXS-123 Access Control Unit Installation Guide , Document 800-0 5779, Revision A v L IST OF F IGURES Figure 1: NetAXS-123 Compact Enclosure Wi ring and Components ............. .......................... 3 Figure 2: NetAXS-123 Standard Enclosure Panel Wiring and Components ......................... .... 4 Figure 3: NetAXS-123 Add-On Board Wiring ...

  • Honeywell NETAXS-123 - page 6

    vi www.honeywell.com ...

  • Honeywell NETAXS-123 - page 7

    NetAXS-123 Access Control Unit Installation Guide , Document 800-0 5779, Revision A vii L IST OF T ABLES Table 1: Supervised Input Terminal Bl ocks ......................... ........................... ...................... ...... 5 Table 2: Supervised Tamper Terminal Blocks ............ ........................... ........................... .... ...

  • Honeywell NETAXS-123 - page 8

    viii www.honeywell.com ...

  • Honeywell NETAXS-123 - page 9

    NetAXS-123 Access Control Unit Installation Guide , Document 800-05779, Revision A 1 Installing the NetAXS-123 P anels In this chapter ... Introduction 2 Panel Component s and Descriptions 3 Installation 1 1 System Configuration 48 Hardware S pecifications 60 Maintenance 64 T roubleshooting 65 T echnical Support 66 ...

  • Honeywell NETAXS-123 - page 10

    2 www .honeywell .com Installing the NetAXS-123 Panels Introduction 1.0 Intr oduction This document describes how to install the NetAXS-123 Standard Enclosure access control unit and the NetAXS-123 Compact Enclosure acce ss control unit. 1.1 Access Control Overview An access control system protects and preserves an en terprise’ s res ources by pr ...

  • Honeywell NETAXS-123 - page 11

    Installing the NetAXS-123 Panels Panel Components and Descriptions NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 3 2.0 P anel Components and Descriptions Note: This device complies with part 15 of the FCC Ru les. Operation is subjec t t o the following two conditions: (1) This device may not cause harmful in te ...

  • Honeywell NETAXS-123 - page 12

    4 www .honeywell .com Installing the NetAXS-123 Panels Panel Components and Descriptions Figur e 2: NetAXS-123 S tandar d Enclosur e Panel W iring and Compon ents Note: Maintain at least a .25-inch distance between the non-power limited wi ring (1 15 V A C/60 Hz input wiring, power line filter wiring, and battery backup/char ger wiring) and all oth ...

  • Honeywell NETAXS-123 - page 13

    Installing the NetAXS-123 Panels Panel Components and Descriptions NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 5 Figur e 3: NetAXS-123 Add-On Boar d W iring and Components 2.1 Supervised Input Wiring The supervised inputs are located on the following terminal blocks: T able 1: Supervised Input T erminal Bloc ...

  • Honeywell NETAXS-123 - page 14

    6 www .honeywell .com Installing the NetAXS-123 Panels Panel Components and Descriptions T ampers can also be supervised. They are located on the following terminal blocks: T able 2: Supervised T amper T erminal Blocks Door Status (STS) and Request to Exit (REX) for all three doors may be configured for Normally Open or Normally Closed contacts as ...

  • Honeywell NETAXS-123 - page 15

    Installing the NetAXS-123 Panels Panel Components and Descriptions NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 7 Caution: The system has not be en verified for compliance with UL10 76 Burglar Alarm units and systems. 2.2 NetAXS-123 Access Control Unit The NetAXS-123 panel is a one-door access control unit tha ...

  • Honeywell NETAXS-123 - page 16

    8 www .honeywell .com Installing the NetAXS-123 Panels Panel Components and Descriptions 2.2.2 Supported Readers Supported readers incl ude the following: T able 4: Readers Supported by NetAXS-1 23 Series Reader Model Honeywell Part Number OmniProx OP-10 OP10GENE OP10HONE OP-30 OP30GENE OP30HONE OP-40 OP40GENE OP40HONE OP-45 OP45GENE OP45HONE HID P ...

  • Honeywell NETAXS-123 - page 17

    Installing the NetAXS-123 Panels Panel Components and Descriptions NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 9 Note: For NetAXS-123 reader spec ifications, see Hardware Specifications , page 60. 2.2.3 Real-Time Clock Protection The panel R TC is back ed up using a super capa ci tor . The super capacitor wil ...

  • Honeywell NETAXS-123 - page 18

    10 www .honeywell .com Installing the NetAXS-123 Panels Panel Components and Descriptions 2.4 Battery For the NetAXS-123 Standard Enclosure panel, one CASIL CA1270, 12 VDC, 7A-hour sealed lead-acid battery (Honeywell order number 3-000066). The b attery provides standby backup power , depending upon system configu ration and activity . Wh en AC is ...

  • Honeywell NETAXS-123 - page 19

    Installing the NetAXS-123 Panels Installation NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 11 3.0 Installation 3.1 Inst alling the Co mp act Enclosure Panel Perform the following steps to inst all the NetAXS-123 Compact panel: Wa r n i ng : Use a static strap whenever touching the pa nel to ensure protection f ...

  • Honeywell NETAXS-123 - page 20

    12 www .honeywell .com Installing the NetAXS-123 Panels Installation 3. Mount the board onto the back of the panel. 4. Choose the tamper type (standard or of f-the-wall tamper) and wire the tamper . • W iring a sta ndard tamper: ...

  • Honeywell NETAXS-123 - page 21

    Installing the NetAXS-123 Panels Installation NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 13 • W iring an off-the-wall tamper: 5. Set the tamper , using pliers at the four locations indicated below . Wa r n i ng : Do not apply power at this tim e. ...

  • Honeywell NETAXS-123 - page 22

    14 www .honeywell .com Installing the NetAXS-123 Panels Installation 6. Connect the Ethernet cable and the T amper wire, as shown below . 7. Set DIP switch settings for the panel addres s, communication termin ation and biasing. See DIP Switch Settings , page 36. 8. Check all wiring at this ti me. Caution: Improper wiring can cause damage to the Ne ...

  • Honeywell NETAXS-123 - page 23

    Installing the NetAXS-123 Panels Installation NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 15 3.1.2 Inst alling over a Gang Box 1. Review the panel layout, cable runs, and power needs. 2. Mount the back of the panel on the gang box. 3. Pull the wires from the g ang bo x through the knockout holes in the base o ...

  • Honeywell NETAXS-123 - page 24

    16 www .honeywell .com Installing the NetAXS-123 Panels Installation 3.1.3 Inst alling on a Flat Surface 1. Review the panel layout, cable runs, and power needs. 2. Mount the back of the enclosure on the surface, either with drywall screes or threaded wall anchors. 3. Break of f the appropriate plastic wiring tabs, using pl iers. 4. Perform steps 3 ...

  • Honeywell NETAXS-123 - page 25

    Installing the NetAXS-123 Panels Installation NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 17 3.2 Inst alling the S t an dard Enclosure Panel Perform the following steps to install th e NetAXS-123 Standard Enclosu re panel: Wa r n i ng : Use a static strap whenever touching the pa nel to ensure protection from ...

  • Honeywell NETAXS-123 - page 26

    18 www .honeywell .com Installing the NetAXS-123 Panels Installation 3. Install the power supply . a. Fit the power supply screws through the key hol es in the left side of the cabinet, and seat the power supply by pulling down. b. From the outside of the cabin et, tighten the screws to lock the power supply in place. ...

  • Honeywell NETAXS-123 - page 27

    Installing the NetAXS-123 Panels Installation NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 19 c. Inside the cabinet, screw in the two se lf-tap ping screws (supplied in the product bo x) at the top and bottom of the power supply . Wa r n i ng : Thes e screws must be installed to ground the power supply to the ...

  • Honeywell NETAXS-123 - page 28

    20 www .honeywell .com Installing the NetAXS-123 Panels Installation d. Plug the connector that is attached to the blue and brown wires into the power supply . ...

  • Honeywell NETAXS-123 - page 29

    Installing the NetAXS-123 Panels Installation NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 21 4. Select one of the following three poss ible entry points for the power cable: Wa r n i ng : Do not apply power at this time. Be sure the power cable is disconnected from the external power source before following t ...

  • Honeywell NETAXS-123 - page 30

    22 www .honeywell .com Installing the NetAXS-123 Panels Installation 5. Use a pencil to mark the loca tion of the holes on the wall. 6. Screw the NetAXS-123 Controller Board with the four captive screws ...

  • Honeywell NETAXS-123 - page 31

    Installing the NetAXS-123 Panels Installation NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 23 7. Hold the Add-On Board over the Controller Boar d and seat th e board-to -board connector into the Controller Board. Sec ure the Add-On Board on to the Controller Board with the four captive finger screws. For more ...

  • Honeywell NETAXS-123 - page 32

    24 www .honeywell .com Installing the NetAXS-123 Panels Installation 8. Connect the wiring harness, as shown. Wa r n i ng : DO NOT CONNECT the AC pow er or the battery wires yet! 9. Power up the NetAXS-123 Controller Boar d and configure the sy stem. Refer to the NetAXS-123 S tartup Guide (800-05780) for instructions. ...

  • Honeywell NETAXS-123 - page 33

    Installing the NetAXS-123 Panels Installation NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 25 10. Connect the battery . 1 1. Attach the door to the cabinet. 12. Re-connect the green ground wire to the cabinet door . ...

  • Honeywell NETAXS-123 - page 34

    26 www .honeywell .com Installing the NetAXS-123 Panels Installation 3.3 Inst alling th e Add-On Board Wa r n i ng : T o prevent damage to the NXC1 Controller Board, rem o v e po w e r from the NetAXS-123 panel before install ing or removing a NetAXS-123 Add-On Board. 1. On the NetAXS-123 Controller Board, locate the four post s called out in the i ...

  • Honeywell NETAXS-123 - page 35

    Installing the NetAXS-123 Panels Installation NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 27 2. Pick up the Add-On Board and no tice the four posts on the bottom. 3. Seat the Add-On Board posts in to the four post s on the NetAXS- 123 Cont roller Board, aligning the terminal-block edge of the Add-On Board wit ...

  • Honeywell NETAXS-123 - page 36

    28 www .honeywell .com Installing the NetAXS-123 Panels Installation 5. Set the relay jumpers. a. Use the following figure to locate the jumpers. b. See Add-On Board DIP Switch and Jumper Settings , page 40, to set the power source (12VDC power or external power) and the relay contact position (Normally Open or Normally Closed). 6. W ire the door s ...

  • Honeywell NETAXS-123 - page 37

    Installing the NetAXS-123 Panels Installation NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 29 3.4 Wiring the Readers Each reader port supports one or two readers (entry and exit readers) with W iegand output format. The maximum power d raw is 500 mA fo r readers and AUX Power combined. T o fully utilize each r ...

  • Honeywell NETAXS-123 - page 38

    30 www .honeywell .com Installing the NetAXS-123 Panels Installation Ta b l e 5 show s the input/output factory de fault wiring for a one-door config uration on the Controller Board. T able 5: Factory Default Configuration Settings for Door 1 a Readers A and B share the same connection. T ype Purpose W eb Default Name T erminal Block Label Reader A ...

  • Honeywell NETAXS-123 - page 39

    Installing the NetAXS-123 Panels Installation NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 31 Notes : • The Controller Board includ es Inputs 7 and 8 but they are reserved for s ystem use. • The Controller Board also includ es Output 5, a general-purpose output, and Output 6, which is reserved by the syste ...

  • Honeywell NETAXS-123 - page 40

    32 www .honeywell .com Installing the NetAXS-123 Panels Installation Ta b l e 7 lists the factory Add-On Board default settings for a door 3. These mappings should be used for the readers, inputs, and outputs when either a 1- or 2-door Add-On Board is attache d to the board-to-board connector on the controller board. T able 7: Factory Default Confi ...

  • Honeywell NETAXS-123 - page 41

    Installing the NetAXS-123 Panels Installation NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 33 • NetAXS-123 supports a variety of W iegand reader models. Some readers have only one brown wire for LED control; others have two possib le LED control inputs--orange f or the green LED and brown for the re d LED. R ...

  • Honeywell NETAXS-123 - page 42

    34 www .honeywell .com Installing the NetAXS-123 Panels Installation 2. Use the following figure to wire the door stri ke/mag lock according to the power supply used. Be sure to use the S4 suppressor kits as shown below . Notes: • As shown in the illustration above, the Dr y C terminal for the On -Board option should not be connected. Similarly o ...

  • Honeywell NETAXS-123 - page 43

    Installing the NetAXS-123 Panels Installation NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 35 3.6 Setting DIP Switches and Jumpers 3.6.1 Controller Board DIP Switch and Jumper Settings Figure 6 locates the NetAXS-123 DIP switch panel an d the output 1 and output 3 rela y jumpers. Figur e 6: Contr oller Boar d ...

  • Honeywell NETAXS-123 - page 44

    36 www .honeywell .com Installing the NetAXS-123 Panels Installation DIP Switch Settings Use the following DIP switch configur ations to set the panel address. T able 8: NetAXS-123 SW1 DIP Switch Settings S1 S2 S3 S4 S5 S6 S7 a S8 b S9 b S10 Selection ON OFF OFF OFF OFF Address 1 (default) OFF ON OFF OFF OFF Address 2 ON ON OFF OFF OFF Address 3 OF ...

  • Honeywell NETAXS-123 - page 45

    Installing the NetAXS-123 Panels Installation NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 37 O F F O NO NO F F O N Address 22 ON ON ON OFF ON Address 23 OFF OFF OFF ON ON Address 24 ON OFF OFF ON ON Address 25 OFF ON OFF ON ON Address 26 ON ON OFF ON ON Address 27 OFF OFF ON ON ON Address 28 ON OFF ON ON ON A ...

  • Honeywell NETAXS-123 - page 46

    38 www .honeywell .com Installing the NetAXS-123 Panels Installation Note: Address 0 is not a valid setting. b. Both DIP Switch 8 and DIP Switch 9 need to be either ON or OFF to be properly configured. T able 9: NetAXS-123 SW2 DIP Switch Settings S1 a S2 a Selection OFF OFF RS-485_2 termination (EOL) DISABLED ON ON RS-485_2 terminatio n (EOL) ENABL ...

  • Honeywell NETAXS-123 - page 47

    Installing the NetAXS-123 Panels Installation NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 39 Jumper Settings The NetAXS-123 Controller Board provides two jumper sets, one each for output relay 1 and output relay 3. Each relay has two 3-pin jumpers associa ted with it. One jumper select s either exte rnal powe ...

  • Honeywell NETAXS-123 - page 48

    40 www .honeywell .com Installing the NetAXS-123 Panels Installation Note: The power source selected by the jumper setti ngs shown ab ove configur e the power source for the relay . It does not configure the power source for the panel. • Setting the jumpers to configure the relay contact type: 3.6.2 Add-On Board DIP Sw itch and Jumper Settings Fi ...

  • Honeywell NETAXS-123 - page 49

    Installing the NetAXS-123 Panels Installation NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 41 used to select Normally Open (NO) or Normally Closed (NC) relay contacts. There is a total of four 3-pin jumpers (two per relay) on the controller b oard. • Setting the jumpers to configure the power source: • Set ...

  • Honeywell NETAXS-123 - page 50

    42 www .honeywell .com Installing the NetAXS-123 Panels Installation 3.7 Communications 3.7.1 USB Communications The NetAXS-123 Controller Board p rovides a version 2.0 USB port that connects to the web b rowser or to a WIN-P A K host. The following figure identifies the location of the port on the board. Note: USB communication requir es the USB A ...

  • Honeywell NETAXS-123 - page 51

    Installing the NetAXS-123 Panels Installation NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 43 2. Click Install USB Drivers on the product men u to start the USB driver installation wizard. 3. Click Next to display the Ready to Install the Program screen. Note: If confirmation dialo g boxes pop up before or dur ...

  • Honeywell NETAXS-123 - page 52

    44 www .honeywell .com Installing the NetAXS-123 Panels Installation 5. When the installation is comple te, the closing screen appears: 6. Click Finish . 7. Connect the computer to the NetAXS-123 co ntroller with a USB-A to Micro USB-B cable. 8. T urn on the power to the NetAXS-123 controller . For login information, go to https://192.168.2.150. 3. ...

  • Honeywell NETAXS-123 - page 53

    Installing the NetAXS-123 Panels Installation NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 45 DIP switch SW1 positions 8 and 9 are provided for supplying biasing and end-of-line termination for the RS-485 network. The board sh ips with the switches active. For a Multidrop RS-485 Line, you must turn ON both swi ...

  • Honeywell NETAXS-123 - page 54

    46 www .honeywell .com Installing the NetAXS-123 Panels Installation Figur e 10: RS-485 Configuration via NetAXS-12 3 Gateway This configuration supports a total of 31 NetAXS and NetAXS -123 panels per Multidrop line. Reader 4 Reader 3 Reader 4 Reader 1 NetAXS-123 Gateway . . . . . . . . . . . . T erminal Ethernet RS-485 Multidrop Line ...

  • Honeywell NETAXS-123 - page 55

    Installing the NetAXS-123 Panels Installation NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 47 3.7.3 Ethernet TCP/IP Communications Figur e 1 1: Ethernet TCP/IP Configuration This configuration supports a total of 31 NetAXS and NetAXS -123 panels per Multidrop line. Each NetAXS-123 panel has a port for an Ether ...

  • Honeywell NETAXS-123 - page 56

    48 www .honeywell .com Installing the NetAXS-123 Panels System Configuration 4.0 System Configuration This section provides wiring diagrams for each of the NetAXS-123 system co nfigurations. 4.1 Ethernet Connection Figur e 12: Ethernet Connection Note: Y ou should ground each NetAXS-123 S tandard (Metal) Enclosure panel individually with an Earth G ...

  • Honeywell NETAXS-123 - page 57

    Installing the NetAXS-123 Panels System Configuration NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 49 4.2 USB Connection Figur e 13: NetAXS-123 USB Connection Note: The USB connection i s intended to be used for system maintenance and troubleshootin g. Note: Y ou should ground each NetAXS-123 S tandard (Metal) ...

  • Honeywell NETAXS-123 - page 58

    50 www .honeywell .com Installing the NetAXS-123 Panels System Configuration 4.3 RS-485 Connection via PCI-3 This connection supp orts th irty-one NetAXS-123 pane ls for each drop line. No te that PCI-3 units can also be wired in interior , as we ll as in endpoint, positions. See Figure 16 on page 52 and Figure 17 on page 53. Figur e 14: RS-485 Con ...

  • Honeywell NETAXS-123 - page 59

    Installing the NetAXS-123 Panels System Configuration NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 51 4.4 RS-485 Connection via NetAXS-123 This connection supports a total of 31 NetAXS-123 pa nels ( including the Gateway) for each drop li ne. Figur e 15: RS-485 Connection via NetAXS-123 Note: Y ou should groun ...

  • Honeywell NETAXS-123 - page 60

    52 www .honeywell .com Installing the NetAXS-123 Panels System Configuration 4.5 RS-485 Connections with Multidro p Panels at Both Ends of the Cable Y ou can connect Multidrop panels at both ends of an RS-485 cable via either a NetAXS-123 panel or a PCI-3 device. Figur e 16: RS-485 Connection via NetAXS -123 with Multidr o p Panels at Both Ends Not ...

  • Honeywell NETAXS-123 - page 61

    Installing the NetAXS-123 Panels System Configuration NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 53 Figur e 17: RS-485 Connection via PCI-3 with Multidr op Panels at Both Ends Note: Y ou should ground each NetAXS-123 S tandard (Metal) Enclosure panel individually with an Earth Ground. COM Port See RS-485 Cab ...

  • Honeywell NETAXS-123 - page 62

    54 www .honeywell .com Installing the NetAXS-123 Panels System Configuration 4.6 M-56K Dial-up Modem, RS-4 85 Connection via Hub (PCI-3) This configuration supports 3 1 NetAXS-123 panels for each drop line. Figur e 18: M-56K Dial-up Modem, RS-4 85 Connection via Hub Note: Y ou should ground each NetAXS-123 S tandard (Metal) Enclosure panel individu ...

  • Honeywell NETAXS-123 - page 63

    Installing the NetAXS-123 Panels System Configuration NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 55 4.7 Fiber Converter to RS-485 Connection via PCI-3 This connection supp orts 31 NetA XS-123 panels for each drop line. Figur e 19: Fiber Converter to RS-485 Connection via PCI-3 ...

  • Honeywell NETAXS-123 - page 64

    56 www .honeywell .com Installing the NetAXS-123 Panels System Configuration 4.8 Fiber Converter to RS -485 Connection via NetAXS-123 This connection supp orts 31 NetA XS-123 panels for each drop line. Figur e 20: Fiber Converter to RS-485 Connection via NetA XS-123 Note: Y ou should ground each NetAXS-123 S tandard (Metal) Enclosure panel individu ...

  • Honeywell NETAXS-123 - page 65

    Installing the NetAXS-123 Panels System Configuration NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 57 4.9 N-485-PCI-3/NetAXS -123 Access Controller Pa nel Connection Det ail Figur e 21: N-485-PCI-3/NetAXS-123 Access Controller Panel Connection Detail ...

  • Honeywell NETAXS-123 - page 66

    58 www .honeywell .com Installing the NetAXS-123 Panels System Configuration 4.10 NetAXS-123/NetAXS -123 Access Controller Panel Connection Det ail Figur e 22: NetAXS-123/NetAXS-123 Access Contr oller Panel Connection Detail X DO NOT C ONNECT or GROUND SHIELD Ground only one side of cable shield Shield Ground Shield 485 - 485 Common 485 + 4,000 ft. ...

  • Honeywell NETAXS-123 - page 67

    Installing the NetAXS-123 Panels System Configuration NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 59 4.1 1 Mixed Loops This mixed-loop configur ation supports a combined total of 31 N1000 III, N1000 IV , NetAXS, NetAXS-123, and NS2 panels per Multidrop line. ...

  • Honeywell NETAXS-123 - page 68

    60 www .honeywell .com Installing the NetAXS-123 Panels Hardware Specifications 5.0 Har dware Specifications The specifications in this section apply to both th e Standard Enclosure and Comp act Enclosure panels. 5.1 Relay Cont act s Maximum of six Form-C SPDT relays, 3A (at dry co ntact) or 0.5A (at self-whetted) @ 30VDC (P TC limited in the self- ...

  • Honeywell NETAXS-123 - page 69

    Installing the NetAXS-123 Panels Hardware Sp ecificatio ns NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 61 Example : If the total current consumption of your extern al devices exceeds the 450mA maximum current maximum, then use one of the fo llowing system configurations: • Power the panel with an external 1 ...

  • Honeywell NETAXS-123 - page 70

    62 www .honeywell .com Installing the NetAXS-123 Panels Hardware Specifications 5.6 Environment • T emperature: 0C to 49C operating, -55 C to +85C storage. • Humidity: 5% to 85% RHNC. 5.7 Cable Use industry-standard cables that meet the following specifications: T able 10: Reader W i ring Cable Specifications Descri ption A WG Maximum Distance: ...

  • Honeywell NETAXS-123 - page 71

    Installing the NetAXS-123 Panels Basic S tandalone Operation NetAXS-123 Access Control Un it Installation Guide , Document 800-05779, Revision A 63 6.0 Basic Standalone Operation 6.1 Card Read / Door Lock Operation 1. Present a card to a reader . 2. The reader sends the card number to a reader input on the panel. 3. The panel searches its data base ...

  • Honeywell NETAXS-123 - page 72

    64 www .honeywell .com Installing the NetAXS-123 Panels Maintenance 7.0 Maintenance Perform the following maintenanc e on the NetAXS-123 enclosure: • Change the backup battery ever y two to two-and-a-half years. • Oil the lock once per year . • Use the following procedure to change the 1A, 250V , Bussan type GMA fuse in the fuse terminal bloc ...

  • Honeywell NETAXS-123 - page 73

    Installing the NetAXS-123 Panels T roubleshooti ng NetAXS-123 Access Control Unit Installation Guide , Document 800-05779, Revision A 65 8.0 T r oubleshooting Note: The NetAXS-123 EOL network is AC -coupled. There is no res istance diff erence between the RS-485 positive and negative terminals if the EOL network is on or off (SW1, switches 8 and 9) ...

  • Honeywell NETAXS-123 - page 74

    66 www .honeywell .com Installing the NetAXS-123 Panels T echnical Support 9.0 T echnical Support 9.1 Normal Support Hours Monday through Friday , 7:00 a.m. to 7:00 p.m. Central Standard T ime (CST), except company holidays: (8 00) 323-4576. 9.2 We b For technical assistance please vi sit http://www .hon eywellaccess.com ...

  • Honeywell NETAXS-123 - page 75

    Installing the NetAXS-123 Panels T echnical Support NetAXS-123 Access Control Unit Installation Guide , Document 800-05779, Revision A 67 This p age is left blank for printing purposes. ...

  • Honeywell NETAXS-123 - page 76

    Honeywell Access Systems 135 W . F orest Hill A venue Oak Creek, WI 53154 United States 800-323-4576 414-766-1798 F ax www .honeywellaccess.com Specifications subject to change without notice. © Honeyw ell. All r ights reser ved. Document 800-05799, Revision A ...

Manufacturer Honeywell Category Network Hardware

Documents that we receive from a manufacturer of a Honeywell NETAXS-123 can be divided into several groups. They are, among others:
- Honeywell technical drawings
- NETAXS-123 manuals
- Honeywell product data sheets
- information booklets
- or energy labels Honeywell NETAXS-123
All of them are important, but the most important information from the point of view of use of the device are in the user manual Honeywell NETAXS-123.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Honeywell NETAXS-123, service manual, brief instructions and user manuals Honeywell NETAXS-123. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Honeywell NETAXS-123.

Similar manuals

A complete manual for the device Honeywell NETAXS-123, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Honeywell NETAXS-123 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Honeywell NETAXS-123.

A complete Honeywell manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Honeywell NETAXS-123 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Honeywell NETAXS-123, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Honeywell NETAXS-123, that we can find in the current document
3. Tips how to use the basic functions of the device Honeywell NETAXS-123 - which should help us in our first steps of using Honeywell NETAXS-123
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Honeywell NETAXS-123
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Honeywell NETAXS-123 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Honeywell NETAXS-123?

Use the form below

If you did not solve your problem by using a manual Honeywell NETAXS-123, ask a question using the form below. If a user had a similar problem with Honeywell NETAXS-123 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)