    omega.com e-mail: info@omega.com Fo r la te st p ro du ct m an ua ls : omegamanual.info U ser ’ s Guide A 2 4 0 0 S e r i e s R ad i o M od e m M od u le Shop online at MADE IN ...

  • Omega A2400 - page 2

    Servicing Nor th America: U.S.A.: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: U.S.A. and Canada: Sa ...

  • Omega A2400 - page 3

    A2400 USERS MANUAL REVISED: 4/17/95 OMEGA ENGINEERING ONE OMEGA DRIVE P. O. BOX 4047 STAMFORD, CT 06907 PHONE: 1-800-DAS-IEEE FAX: 203-359-7990 e-mail: das@omega.com www.omega.com The information in this publication has been carefully checked and is believed to be accurate; however, no responsibility is assumed for possible inaccuracies or omission ...

  • Omega A2400 - page 4

    TABLE OF CONTENTS CHAPTER 1 Getting Started Quick Hook-Up 1-3 Default Mode 1-4 CHAPTER 2 Functional Description Block Diagram 2-1 CHAPTER 3 Communications RS-485 3-2 Multi-party Connection 3-3 RS-485 Multidrop System 3-4 CHAPTER 4 Command Set Table of Commands 4-6 User Commands 4-6 Error Messages 4-13 CHAPTER 5 Setup Information and Command Command ...

  • Omega A2400 - page 5

    Chapter 1 Getting Started Introduction This manual describes the function and application of the Radio Modem Interface Module (A2400). The A2400 provides an intelligent interface between radio modems available from many manufacturers and devices designed to operate on a bi-directional RS-485 serial bus. Although the A2400 has been designed specific ...

  • Omega A2400 - page 6

    Getting Started 1 -2 A2400 is to control the slave transmitter to allow multiple slave sites. Figure 1.1 System Overview. Leased Lines This manual has been written with emphasis on radio modems. However, the A2400’s may be used just as effectively with leased telephone lines. Typically, leased lines do not have dial-up capability and some means o ...

  • Omega A2400 - page 7

    Getting Started 1 -3 Getting Started To get your A2400 up and running for an initial check-out, connect the unit to a power supply and terminal as shown in Figure 1.2. The power supply can be any dc source from 10 to 30 volts, capable of 1 Watt of power. The terminal can be any RS-232 dumb terminal set for 300 baud. A computer configured as a termi ...

  • Omega A2400 - page 8

    Getting Started 1 -4 This message is terminated with a carriage return. If the response message cannot be obtained, re-check all the wiring, making sure that the proper power is on the A2400 connector and that the DEFAULT* line is shorted to the GND pin. The terminal must be set to 300 baud. If, after several attempts, the response message does not ...

  • Omega A2400 - page 9

    Getting Started 1 -5 values (NULL, CR, $, #, {, }). A dummy address must be included in every command for proper responses. Setup information in an A2400 may be changed at will with the SetUp (SU) command. Baud rates and parity setups may be changed without affecting the Default values of 300 baud and no parity. When the DEFAULT* pin is released, t ...

  • Omega A2400 - page 10

    Chapter 2 Functional Description Block Diagram The A2400 is an RS-232/RS-485 converter specifically designed to inter- face D series RS-485 modules to radio modems. To this end the A2400 provides three functions: 1) Perform the RS-232 to RS-485 electrical conversion. 2) Control the data direction of the RS-485 bus. 3) Create hand-shaking signals to ...

  • Omega A2400 - page 11

    Functional Description 2-2 EEPROM MICRO- PRCESSOR +5 5.6K DO0/RTS RX TX CTS RTS +5V UART RX TX DEFAULT Figure 2.1 A2400 Block Diagram. ...

  • Omega A2400 - page 12

    Functional Description 2-3 Pinout 1) TRANSMIT This is the RS-232 Transmit output from the A2400. This pin is normally connected to the Receive input of a modem. This output is also used to connect to a terminal or computer to configure the A2400 2) RECEIVE This is the RS-232 Receive input of the A2400. This pin is normally connected to the Data Out ...

  • Omega A2400 - page 13

    Functional Description 2-4 bus. This bus connects to multidrop RS-485 devices such as D series modules. 8) (G)DATA- This is the negative polarity of the differential RS-485 bus. 9) (R)V+ A2400 power connection. The A2400 operates on 10 to 30 volts dc. 10) (B)GND This is the ground connection common to all circuits. The A2400 does not have isolation ...

  • Omega A2400 - page 14

    Functional Description 2-5 reaching the RS-485 bus. The first operation performed on the modem data is to check for noise and framing errors. If either condition exists, the bad character is re-formatted as a null character (ASCII $00). Since the null is not a legal character for use as an address in the modules, transmitting a null is preferable t ...

  • Omega A2400 - page 15

    Functional Description 2-6 addressed command and it responds back with information on the bus. The A2400 receives this information and places it in a buffer that can hold up to 96 characters. The parity of received characters is ignored. As soon as a character is received, the A2400 starts a timing sequence to control the modem transmitter. Three u ...

  • Omega A2400 - page 16

    Functional Description 2-7 T1 As soon as the A2400 detects a character in the RS-485 receive buffer, time delay T1 is activated. This is a dead time to allow the host to prepare for the receipt of a message. This is particularly important when a simplex connec- tion is used, where the send and receive data is transmitted on the same frequency. Duri ...

  • Omega A2400 - page 17

    Chapter 3 Communications Introduction The A2400 modules have been carefully designed to be easy to interface to all radio modems and many leased-line modems. All communications to and from the modules are performed with printable ASCII characters. This allows the information to be processed with string functions common to most high- level languages ...

  • Omega A2400 - page 18

    Communication 3-2 improper command prompt or address is transmitted. The table below lists the timeout specification for each command assuming that delay times T1, T2, T3 = 0: Table 3.1 Response Timeout Specifications. Mnemonic Timeout DO, OC, CC, RD, REA, RID, RLP, RS, RSP, RSU, ≤ 10 ms RT1, RT2, RT3, WE EA, ID, LP, RID, RR, SP, SU, T1, T2, T3 ? ...

  • Omega A2400 - page 19

    Communication 3-3 ...

  • Omega A2400 - page 20

    Communication 3-4 RS-485 Multidrop System Figure 3.1 illustrates the wiring required for multiple-module RS-485 system. Notice that every module has a direct connection to the A2400. Any number of modules may be unplugged without affecting the remaining modules. Each module must be setup with a unique address and the addresses can be in any order. ...

  • Omega A2400 - page 21

    Communication 3-5 becomes an important consideration. The GND wire is used both as a power connection and the common reference for the transmission line receivers in the modules. Voltage drops in the GND leads appear as a common-mode voltage to the receivers. The receivers are rated for a maximum of -7V. of common-mode voltage. For reliable operati ...

  • Omega A2400 - page 22

    Chapter 4 A2400 Command Set The A2400 operates with a simple command/response protocol to control all module functions. A command must be transmitted to the A2400 by the host computer or terminal before the A2400 will respond with useful data. A module can never initiate a communications sequence. A list of available commands and a sample format fo ...

  • Omega A2400 - page 23

    Command Set 4-2 All commands must be terminated by a carriage return character (ASCII $0D). In all command examples in this text the carriage return is either implied or denoted by the symbol ‘CR’. Data Structure Many commands require additional data values to complete the command definition as shown in the example commands in Table 4.1. The pa ...

  • Omega A2400 - page 24

    Command Set 4-3 A command/response sequence is not complete until a valid response is received. The host may not initiate a new command until the response from a previous command is complete. Failure to observe this rule will result in communications collisions. A valid response can be in one of three forms: 1) a normal response indicated by a ‘ ...

  • Omega A2400 - page 25

    Command Set 4-4 interprets a command, it looks for the two extra characters and assumes that it is a checksum. If the checksum is not present, the module will perform the command normally. If the two extra characters are present, the module will calculate the checksum for the message. If the calculated checksum does not agree with the transmitted c ...

  • Omega A2400 - page 26

    Command Set 4-5 Example: Append a checksum to the command $1WE Characters: $ 1 W E ASCII hex values: 24 31 57 45 Sum (hex addition) 24 + 31 + 57 + 45 = F1 The checksum is F1 (hex). Append the characters F and 1 to the end of the message: $1WEF1 Example: Verify the checksum of a module response *1WEF7 The checksum is the two characters preceding the ...

  • Omega A2400 - page 27

    Command Set 4-6 Each A2400 user command is described in detail following Table 4.1. All of the commands are listed in alphabetical order according to command nomenclature. Table 4.1 A2400 Command Set Command and Definition Typical Typical Command Response Message Message ($ prompt) DO Digital Output $1DO01 * RD Read Data $1RD *+99999.99 REA Read Ex ...

  • Omega A2400 - page 28

    Command Set 4-7 Command Descriptions All the commands may be used with normal addressing or Extended Addressing unless otherwise noted. Commands that are exclusive to the Extended Address mode are noted near the right hand margin. For example: Closed Channel (CC) (Extended) Closed Channel (CC) (Extended) The Close Channel (CC) command is an Extende ...

  • Omega A2400 - page 29

    Command Set 4-8 To turn the output off you could use the command: Command: $1DO00 Response: * Command: #1DO00 Response: *1DO004E Digital output 0 shares the connector pin with the Alternate RTS. Bit 3 of byte 4 of the SetUp command is used to configure this pin as either digital output or RTS function. See chapter 5 for details. The digital output ...

  • Omega A2400 - page 30

    Command Set 4-9 Identification (ID) The IDentification command allows the user to write a message into the nonvolatile memory which may be read back at a later time with the Read IDentification (RID) command. It serves only as a convenience to the user and has no affect on the module operation. Any message up to 16 characters long may be stored in ...

  • Omega A2400 - page 31

    Command Set 4-10 Open Channel (OC) (Extended) The Open Channel (CC) command is used to open the communications data channel in Extended Address mode. The open channel will allow serial communications data to flow from the A2400’s RS-232 port to a string of RS- 485 devices. The open communications channel will remain open until a Close Channel (CC ...

  • Omega A2400 - page 32

    Command Set 4-11 In this example the ‘30’ and ‘31’ are the hex ASCII codes for the characters ‘0’ and ‘1’ respectively. The Extended Address is ‘01’. Read Identification (RID) The Read IDentification command reads back the user data stored by the IDentification (ID) command. The ID and RID commands are provided as a convenience ...

  • Omega A2400 - page 33

    Command Set 4-12 Command: #1RR Response: *1RRFF Read Setup (RS or RSU) The read setup command reads back the setup information stored in the A2400’s EEPROM with the SetUp (SU) command. The response to the RS or RSU command is four bytes of information formatted as eight hex characters. The response contains the module’s channel address, baud ra ...

  • Omega A2400 - page 34

    Command Set 4-13 Read Time Delay 1 (RT1) The Read Time 1 command reads back the time value stored in EEPROM by T1 command. Command: $1RT1 Response: *+00100.00 Command: #1RT1 Response: *1RT1+00100.00DC Read Time Delay 2 (RT2) The Read Time 2 command reads back the time value stored in EEPROM by the T2 command. Command: $1RT2 Response: *+00500.00 Com ...

  • Omega A2400 - page 35

    Command Set 4-14 The SetUp command requires an argument of eight hexadecimal digits to describe four bytes of setup information. Command: $1SU31070007 Response: * Command: #1SU31070007 Response: *1SU3107000795 Set Time Delay 1 (T1) T1 is a programmable time delay used to control the RTS output. T1 is used to guarantee a dead time between the comple ...

  • Omega A2400 - page 36

    Command Set 4-15 T2 is specified in units of milliseconds with a range of 0 to 2000ms. The time data must be formatted as a plus sign, five decimal digits, a decimal point, and two additional digits: Command: $1T2+00350.00 (Set T2 to 350 ms.) Response: * Command: #1T2+00350.00 (Set T2 to 350 ms.) Response: *1T2+00350.0092 Set Time Delay 3 (T3) T3 i ...

  • Omega A2400 - page 37

    Command Set 4-16 Short Prompt (SP) The Short Prompt command allows the user to specify a desired short prompt ASCII character. A two character hexadecimal value is used to define the desired ASCII character prompt. Note: Short Prompt command may be sent to the module in either normal addressing or Extended Addressing mode. The user-defined short fo ...

  • Omega A2400 - page 38

    Command Set 4-17 Command: }01WE Response: *01WE27 If a module is write enabled and the execution of a command results in an error message other than WRITE PROTECTED, the module will remain write enabled until a command is successfully completed resulting in an ‘*’ prompt. This allows the user to correct the command error without having to execu ...

  • Omega A2400 - page 39

    Command Set 4-18 COMMAND ERROR This error occurs when a command is not recognized by the module. Often this error results when a command is sent with lowercase letters. All valid commands use uppercase characters. PARITY ERROR A parity error can only occur if the module is setup with parity on. Usually a parity error results from a bit error caused ...

  • Omega A2400 - page 40

    Chapter 5 Setup Information/SetUp Command The A2400 features a wide choice of user configurable options which gives them the flexibility to operate on virtually any radio or leased-line modem. The user options include a choice of baud rate, parity, address, and many other parameters. The particular choice of options for a module is referred to as t ...

  • Omega A2400 - page 41

    SetUp Command 5-2 A typical SetUp command would look like: $1SU31070102 Notice that each byte is represented by its two-character ASCII equivalent. In this example, byte 1 is described by the ASCII characters ‘31’ which is the equivalent of binary 0011 0001 (31 hex). The operand of a SU command must contain exactly 8 hex (0-F) characters. Any d ...

  • Omega A2400 - page 42

    SetUp Command 5-3 to communicate with a module with an unknown address is with the Default Mode. The most significant bit of byte 1 (bit 7) must be set to ‘0’. In addition, there are six ASCII codes that are illegal for use as an address. These codes are $00, $0D, $24, $23, $7B, $7D which are ASCII codes for the characters NUL, CR, $, #, {, and ...

  • Omega A2400 - page 43

    SetUp Command 5-4 Byte 2 Byte 2 is used to configure some of the characteristics of the communica- tions channel; linefeeds, parity, and baud rate. Linefeeds The most significant bit of byte 2 (bit 7) controls linefeed generation by the module. This option can be useful when using the module with a dumb terminal. All responses from the modules are ...

  • Omega A2400 - page 44

    SetUp Command 5-5 changed, a module reset must occur. A reset is performed by sending a Remote Reset (RR) command or powering down. This extra level of write protection is necessary to ensure that communications to the module is not accidentally lost. This is very important when changing the baud rate of an RS-232C string. For more information on c ...

  • Omega A2400 - page 45

    SetUp Command 5-6 Command: $1RR Response: * Up to this point all communications have been sent at 300 baud. The module will not respond to any further communications at 300 baud because it is now running at 9600 baud. At this point the host computer or terminal must be set to 9600 baud to continue operation. If the module does not respond to the ne ...

  • Omega A2400 - page 46

    SetUp Command 5-7 Byte 3 This byte contains determines which addressing mode will be used. The default value for this byte is ‘00’. Normal addressing The normal addressing mode refers to the D series protocol of using a single ASCII character for a channel address. There are up to 124 possible addresses in this mode. Extended addressing The ext ...

  • Omega A2400 - page 47

    Chapter 6 Delay Time Programming Each A2400 contains user-programmable delays to properly sequence the transmission of data from a remote radio modem to a host computer. The delays are required to sequence an external transmit enable signal required by most radio modems. The external transmit enable signal most often used is the RS-232 Request to S ...

  • Omega A2400 - page 48

    Delay Time Programming 6-2 Figure 6.1 Programmable delay times. As described in figure 6.1 the communications sequence assumes a host computer communicating with a module on the RS-485 bus through the A2400. In an idle condition, when no data is present on the communications lines, the A2400 turns its RS-485 transceiver to receive mode and monitors ...

  • Omega A2400 - page 49

    Delay Time Programming 6-3 the data over the RS-485 bus. This data is normally command data being sent to a module on the bus. When the RS-232 command data is complete, the A2400 immediately turns its RS-485 transceiver back to receive mode and monitors the RS-485 bus. In normal operation the A2400 looks for a D series response prompt character, ei ...

  • Omega A2400 - page 50

    Delay Time Programming 6-4 Command: $1T3+00050.00 (set T3 to 50 ms.) Response: * Time may be set to 1 ms. resolution. The T1, T2, T3 commands are write-protected and must be preceded by a Write Enable (WE) command. The delay times are stored in nonvolatile memory. The delay times are inactive in Default Mode. The delay times stored in the A2400 may ...

  • Omega A2400 - page 51

    Chapter 7 Power Supply A2400 modules may be powered with an unregulated +10 to +30Vdc. Power-supply ripple must be limited to 5V peak-to-peak, and the instanta- neous ripple voltage must be maintained between the 10 and 30 volt limits at all times. All power supply specifications are referred to the module connector; the effects of line voltage dro ...

  • Omega A2400 - page 52

    Chapter 8 Troubleshooting Symptom: RS-232 Module is not responding to commands 1 Using a voltmeter, measure the power supply voltage at the +Vs and GND terminals to verify the power supply voltage is between +10 and +30Vdc. 2 Verify using an ohmmeter that there are no breaks in the communica- tions data lines. 3 Connect the module to the host compu ...

  • Omega A2400 - page 53

    Chapter 9 Extended Addressing The A2400 may be configured to a special command format called Extended Addressing. This mode uses a different prompt, either ‘{‘ or ‘}’ to distinguish it from the regular command syntax. The major difference in syntax for the Extended Addressing mode is that it uses a two-character address. A typical command i ...

  • Omega A2400 - page 54

    Extended Addressing 9-2 Figure 7.1 Typical system overview. ...

  • Omega A2400 - page 55

    Extended Addressing 9-3 When the system is initially powered up, the A2400’s are set to the Close Channel condition. This means that no data received by the radio modems will pass to the RS-485 bus at either site. In order to communicate to the modules, one of the A2400’s must be set to the Open Channel condition: Command: {01OC Response: * Thi ...

  • Omega A2400 - page 56

    Extended Addressing 9-4 Figure 7.1 shows a very simple system but the same addressing methodmay be used to construct very large systems. Each RS-485 string may handle up to 122 addresses, and up to 14884 A2400’s may have unique addresses. Structured Addressing Even for a relatively small system, it can be advantageous to employ a hierarchical add ...

  • Omega A2400 - page 57

    Extended Addressing 9-5 All commands that are available with single-byte addressing may be accessed with Extended Addressing, and vice-versa; the only exceptions being the OC and CC commands, which can be used only with Extended Addressing. OC and CC Command Formats Once an A2400 has been configured correctly in Extended Address mode, the only comm ...

  • Omega A2400 - page 58

    Extended Addressing 9-6 This command will close the channel at A2400 #01 and open the channel at A2400 #02. This is the quickest method of opening and closing A2400 channels. It also offers the least amount of data security. A2400 #01 was closed solely upon detecting the ‘{‘ character. There is no confirmation that A2400 #01 is closed. If A2400 ...

  • Omega A2400 - page 59

    Extended Addressing 9-7 To explicitly close the channel of A2400 #01: Command: {01CC Response: * The response message is a confirmation that the channel has been closed. A higher level of confirmation can be obtained with the long form: Command: }01CC Response: *01CC11 (‘11’ is the checksum) The response confirms that channel ‘01’ has been ...

  • Omega A2400 - page 60

    Chapter 10 Transparent Mode The A2400 is an RS-232/RS-485 converter designed to provide interface virtually any product to a radio and leased telephone line modems. In normal operation the A2400 is configured to work on the D series protocol, but it may be configured to a special communications mode called the transparent mode. When used in the tra ...

  • Omega A2400 - page 61

    Transparent Mode 10-2 The following examples 1 through 4 illustrate the application of the A2400 in the extended mode of operation. The A2400 in transparent mode allows equipment from various sources to be added to a network of D series modules. However the following rules must apply: 1. half duplex communications. 2. 10-bit data format. 3. The equ ...

  • Omega A2400 - page 62

    Transparent Mode 10-3 Example 2. A2400 networking several RS-232 devices to a host com- puter. Figure 10.2 A2400 networking several RS-232 devices to a host computer. ...

  • Omega A2400 - page 63

    Transparent Mode 10-4 Example 3. A2400 interfacing a device with a string of modules. Figure 10.3 A2400 interfacing a laboratory instrument with modules. ...

  • Omega A2400 - page 64

    Transparent Mode 10-5 Example 4. A2400 interfacing several instruments with a string of modules. ...

  • Omega A2400 - page 65

    Transparent Mode 10-6 Figure 10.5 Adding secondary control using A2400 modules. ...

  • Omega A2400 - page 66

    Transparent Mode 10-7 Figure 10.5 shows an application where the user was able to add a back-up or secondary control supervision using the A2400 modules. The original installation of the flow computers and PLC’s were controlled by the control station using Modbus protocol with RS-485. The user was able to use A2400 modules on the RS232 ports of t ...

  • Omega A2400 - page 67

    WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers r ...

  • Omega A2400 - page 68

    Where Do I Find Ever ything I Need for Pr ocess Measurement and Contr ol? OM EGA…Of Course! Shop online at omega.com TEMPERA TURE 䡺 ⻬ Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies 䡺 ⻬ Wire: Thermocouple, RTD & Thermistor 䡺 ⻬ Calibrators & Ice Point References 䡺 ⻬ Recorders, Controllers & ...

Manufacturer Omega Category Modem

Documents that we receive from a manufacturer of a Omega A2400 can be divided into several groups. They are, among others:
- Omega technical drawings
- A2400 manuals
- Omega product data sheets
- information booklets
- or energy labels Omega A2400
All of them are important, but the most important information from the point of view of use of the device are in the user manual Omega A2400.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Omega A2400, service manual, brief instructions and user manuals Omega A2400. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Omega A2400.

Similar manuals

A complete manual for the device Omega A2400, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Omega A2400 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Omega A2400.

A complete Omega manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Omega A2400 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Omega A2400, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Omega A2400, that we can find in the current document
3. Tips how to use the basic functions of the device Omega A2400 - which should help us in our first steps of using Omega A2400
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Omega A2400
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Omega A2400 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Omega A2400?

Use the form below

If you did not solve your problem by using a manual Omega A2400, ask a question using the form below. If a user had a similar problem with Omega A2400 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)