Manual Omega Engineering OMA-VM520-DCP

12 pages 0.48 mb
Download

Go to site of 12

Summary
  • Omega Engineering OMA-VM520-DCP - page 1

    M4548-0607 omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info U ser ’ s Guide MADE IN Shop online at Manual and Installati on Instructions Four Zone T emperature Monitor and Alarm Models: OMA-VM520 OMA-VM520-DCP ...

  • Omega Engineering OMA-VM520-DCP - page 2

    2 23 WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s custom ...

  • Omega Engineering OMA-VM520-DCP - page 3

    http://{Device IP Address}/ltx_conf.html Click on the “Server Properties” button. Enter the Subnet Mask and/or Gateway Address and click “Update Set- tings” Be sure to enter the correct Subnet Mask and Ga teway Address f or the ne t- work the OMA-V520-DCP is on. If the status web page does not di splay /load correctly (DCP units) Verify tha ...

  • Omega Engineering OMA-VM520-DCP - page 4

    4 General purpose, dry contact input Wiring Diagram Alarm Relay Output Plug in Thermocouple Terminals 1234 K + K + K + K + Sensor 1 Sensor 2 Sensor 3 Sensor 4 K + K + K + K + K type thermocouples with integrated spade connectors 8 W atch the display and no te any messages present. If the Four Zone Tempera ture Monitor and Alarm does not answer the ...

  • Omega Engineering OMA-VM520-DCP - page 5

    Temperature Monitor and Alarm will repeat the wa rning message. This warning message can be repeated up to 2 times by changing the pro- gramm ed value. See the Programming Repeat Warning Messages sec- tion. If the correct PIN number is not ente red the Four Zone Temperature Moni- tor and Alarm will call the next pr ogram med contact te lephone numb ...

  • Omega Engineering OMA-VM520-DCP - page 6

    A ccessing the Four Zone Temp erat ure Monitor over the phone 1 From another phone line call the Four Zo ne Temperature Monitor and Alarm. The device will pick up after the progra m med num ber of rings (Def ault is 1). 2 To access all funct ions, enter the 4-digit "Full Access" PIN. (Fa ctory default is 0000). To access only the "Ac ...

  • Omega Engineering OMA-VM520-DCP - page 7

    18 Sensor Reading A fter Callouts If the Four Zone Temperature Monitor has called all programmed telephone numbers and not made contac t it will wa it 20 minutes before attempting to callout again. Peri odically, the time before callouts resume will be display ed. 1: 510 > 2: 200 3: 4: CALL- OUTS IN 17:25 7 Programming Sensor Parameters 1. Acce ...

  • Omega Engineering OMA-VM520-DCP - page 8

    ming this sensor and return to step 1.b j) You w ill hear “ Enter number then press pound” k) Enter the value then press # . ► Use * to program a negative number (i.e. *20 = -20º ) ► Acceptable range is -999 to 999 l) You w ill hear the value you just entered (i.e. 50º ) m) Proceed to step 4.a 4. Programming the callout delay time a) You ...

  • Omega Engineering OMA-VM520-DCP - page 9

    16 1: ok 2: ok 3: n/c 4: n/c Sensor Present Sensor Present Sensor Not Detected Sensor Not Detected Start Up W hen starting up, the Four Zone Temperature Monitor checks each temperature sensor input to verify that a sensor is connected. If a sensor is connected and has a reading within range, “ok” will be printed next to that sensors label. If a ...

  • Omega Engineering OMA-VM520-DCP - page 10

    10 Acces sing the Program Menu From the Main Menu, press 3 ► The "Full Access" PIN will be reques ted if the " Acknowledge Only " PIN w as entered init ially. If the corr ect "Full Access" PIN is not entered, the Four Zone Temperature Monitor and Alarm w ill hang up. Programming Contact T elephone/Pager Numbers The F ...

  • Omega Engineering OMA-VM520-DCP - page 11

    Changing the Callout Delay Time W hen a refr igerator o r freezer ’s temp erature is out of r ange the Fo ur Zone Temperature Monitor and Al arm will wait this progra mm able amount of tim e before making telephone alert calls. (Default 2 m inutes) 1 From the Progr am Menu, p ress * 2 You w ill hear "Callout Ti me Delay is 2 minutes" 3 ...

  • Omega Engineering OMA-VM520-DCP - page 12

    12 other device. See the Frequently Asked Questions section for details. 1 From the Progr am Menu, p ress 4 to set the number of rings 2 You w ill hear the program med num ber of rings 3 You will hear “Press one to change.” 4 Press 1 to make a change or 2 to return to the Program Menu 5 You w ill hear “ Enter number then press pound” 6 Ente ...

Manufacturer Omega Engineering Category Smoke Alarm

Documents that we receive from a manufacturer of a Omega Engineering OMA-VM520-DCP can be divided into several groups. They are, among others:
- Omega Engineering technical drawings
- OMA-VM520-DCP manuals
- Omega Engineering product data sheets
- information booklets
- or energy labels Omega Engineering OMA-VM520-DCP
All of them are important, but the most important information from the point of view of use of the device are in the user manual Omega Engineering OMA-VM520-DCP.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Omega Engineering OMA-VM520-DCP, service manual, brief instructions and user manuals Omega Engineering OMA-VM520-DCP. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Omega Engineering OMA-VM520-DCP.

A complete manual for the device Omega Engineering OMA-VM520-DCP, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Omega Engineering OMA-VM520-DCP by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Omega Engineering OMA-VM520-DCP.

A complete Omega Engineering manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Omega Engineering OMA-VM520-DCP - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Omega Engineering OMA-VM520-DCP, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Omega Engineering OMA-VM520-DCP, that we can find in the current document
3. Tips how to use the basic functions of the device Omega Engineering OMA-VM520-DCP - which should help us in our first steps of using Omega Engineering OMA-VM520-DCP
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Omega Engineering OMA-VM520-DCP
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Omega Engineering OMA-VM520-DCP in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Omega Engineering OMA-VM520-DCP?

Use the form below

If you did not solve your problem by using a manual Omega Engineering OMA-VM520-DCP, ask a question using the form below. If a user had a similar problem with Omega Engineering OMA-VM520-DCP it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)