Manual ZyXEL Communications 3356P

30 pages 0.08 mb
Download

Go to site of 30

Summary
  • ZyXEL Communications 3356P - page 1

    Comet 3356P User ’ s Manual Version 1.0 ZyXEL A CCESSING THE INTERNET AND INTRANET ...

  • ZyXEL Communications 3356P - page 2

    ii Limited Warranty ZyXEL warrants to the original end user (purchaser) that this product is free from any defects in materials or workm anship for a period of up to two (2) years from the date of purchase. During the warranty period, and upon proof of purchase, should the product have indications of failure due to faulty workmanship and/or materia ...

  • ZyXEL Communications 3356P - page 3

    iii Changes or modifications not expressly approved by the party responsible for compliance could void the user ’ s authority to operate the equipment. Shielded RS-232 cables are required to be used to ensure compliance with FCC Part 15, and it is the responsibility of the user to provide and use shielded RS-232 cables. FCC Requirements This equi ...

  • ZyXEL Communications 3356P - page 4

    iv Outside North America, you can dial +886-3-5783942 EXT 252 between 8:00AM and 5:00PM Taiwan time (GMT +8:00). • Fax : ZyXEL in North America: (714) 693-8811 or Taiwan: +886-3-5782439. • E-mail : • Sales inquiries : sales@zyxel.com in North Am erica. sales@zyxel.com.tw outside North America. • Technical support : support@zyxel.com in Nort ...

  • ZyXEL Communications 3356P - page 5

    v Table of Contents Limited Warranty ii FCC Part 15 Information ii FCC Requirements iii Contacting ZyXEL iii 1 Introduction 1 Unpacking Your Modem 1 Hardware Overview 1 Required Equipment 1 2 Installation 3 Windows 95 3 Windows 3.1 & Windows for Workgroups 3 DOS 3 Windows NT 4.0 4 3 Basic Modem Operation 5 Understanding AT Commands 5 Using the ...

  • ZyXEL Communications 3356P - page 6

    vi Storing Phone Numbers 9 Dialing Stored Phone Numbers 10 Saving Settings and User Profiles 10 Default Modem Settings for PC’s 10 4 AT Command Set Summaries 13 Basic AT Command Set 13 Extended AT& Command Set 15 Extended AT Command Set 16 Extended AT% Command Set 16 Extended AT- Command Set 17 5 Status Registers & Result Codes 19 Result ...

  • ZyXEL Communications 3356P - page 7

    Introduction 1 1 Introduction Congratulations on the purchase of your Comet 3356P Type II PCMCIA card, one of ZyXEL's premier high-performance products. The Com et is world renown for its ability to maintain ultra high speeds and clear, quality connections while communicating around the globe. Unpacking Your Modem Before you proceed, check all ...

  • ZyXEL Communications 3356P - page 8

    2 Introduction ...

  • ZyXEL Communications 3356P - page 9

    Installation 3 2 Installation This chapter describes installation for Windows 95, Windows 3.1, Windows for Workgroups, and DOS. You can jump directly to the installation procedure for your particular environment. Windows 95 1. Insert the Comet into a free PCMCIA slot. 2. Power on your computer and start Windows 95. 3. Windows 95 will display the Ne ...

  • ZyXEL Communications 3356P - page 10

    4 Installation 2. Power on your computer. 3. If you hear an alert sound skip to step 5. If not continue. 4. Use a PCMCIA utility to set your COM port and IRQ information. A PCMCIA utility should have been included with your computer. If not contact your dealer. 5. Install the FAX/MODEM application program that came with your Com et. 6. Connect the ...

  • ZyXEL Communications 3356P - page 11

    Basic Modem Operation 5 3 Basic Modem Operation This chapter covers the basic commands and techniques involved in m odem operation. In many cases, this is the only information you will need in order to get your Com et up and running with communication software, and to start m aking connections with your Comet. Understanding AT Commands The Comet co ...

  • ZyXEL Communications 3356P - page 12

    6 Basic Modem Operation The next window sets the COM port settings. The settings used for the Comet should be as follows: Bits per second: 115200 Data bits: 8 Parity: None Stop bits: 1 Flow Control: Hardware Click “ OK ” when finished. After you have done this, save your new connection by selecting “ Save ” from the “ File ” menu and cl ...

  • ZyXEL Communications 3356P - page 13

    Basic Modem Operation 7 Pausing During Dialing: ATDT 9 ,, 555 1212 Dialing Without Waiting for Dial Tone: AT X0 D, 555 1212 Originating a call using an Answer Tone: ATDT 555 1212,,,,,, R Redialing the Last Number Called: ATD L Waiting for Five Seconds of Silence: ATDT 800 555 1212 @ 123456,1 714 555 1212 Transferring a Call (using flash hook): ATDT ...

  • ZyXEL Communications 3356P - page 14

    8 Basic Modem Operation • Multiple AT commands can be com bined into one line. For example, AT&D2 and AT&K0 can be combined into one line AT&D2&K0. The Comet processes comm ands from left to right. The AT comm and that appears to the right might over-write the comm and to the left if they are trying to accomplish tasks or set mode ...

  • ZyXEL Communications 3356P - page 15

    Basic Modem Operation 9 Modem Result Codes When you execute or try to execute an AT command, your m odem sends a result code to let you know whether the command was executed. An OK result code m eans the AT command you sent was executed. If you receive an ERROR code, it m eans the command was invalid. The Comet also provides result codes that show: ...

  • ZyXEL Communications 3356P - page 16

    10 Basic Modem Operation The ‘ s ’ is a number from 0 to 3 that represents the location in m emory that the phone number is to be stored, and the ‘ n ’ is the phone num ber itself. Example: To store the number ‘ 1-714-555-1212 ’ in mem ory location ‘ 2 ’ , type: AT&Z2=17145551212<Enter> You can store up to 4 telephone numb ...

  • ZyXEL Communications 3356P - page 17

    Basic Modem Operation 11 AT Command Description %C1 Use both V.42bis and MNP 5 data compression ...

  • ZyXEL Communications 3356P - page 18

    12 Basic Modem Operation ...

  • ZyXEL Communications 3356P - page 19

    AT Command Set Sum maries 13 4 AT Command Set Summaries Basic AT Command Set Co mman d Options Function & Descriptio n A/ Re-execute the last command string <any key> Terminate the current connection attempt when entered in handshaking state All the following commands requ ire an “AT” prefix A Go off-hook and attempt to establish a co ...

  • ZyXEL Communications 3356P - page 20

    14 AT Command Set Sum maries Co mman d Options Function & Descriptio n M2 Speaker always on M3 Speaker off during dialing and on until carrier present Nn Select negotiate handshake N0 When originating or answering, handshake only at the communication rate specified by S37 register and “ATBn” and no f allback N1 * When originating or answeri ...

  • ZyXEL Communications 3356P - page 21

    AT Command Set Sum maries 15 Co mman d Options Function & Descriptio n Z0 Reset and recall user profile 0. Either Z0 or Z1 restores the same single profile. * Manufacturer default Extended AT& Command Set Co mman d Options Function & Descriptio n &Cn Data carrier detect option &C0 State of carrier from remote modem is ignored. D ...

  • ZyXEL Communications 3356P - page 22

    16 AT Command Set Sum maries Co mman d Options Function & Descriptio n &W Store active configuration into the modem’ s NVRAM &Zn=x Store telephone number n=0 to 3 x=<string> see also the dial modifier in ”ATDn” command The maximum number of digits per string is 40. * Manufacturer default Extended AT Command Set Co mman d Op ...

  • ZyXEL Communications 3356P - page 23

    AT Command Set Sum maries 17 Co mman d Options Function & Description %Cn Data compression control %C0 No data com pression %C1 * V.42bis/MNP 5 data compression enabled. * Manufacturer default Extended AT- Command Set Co mman d Options Function & Description -Cn Data calling tone options -C0 * Disable data calling tone -C1 Enable data calli ...

  • ZyXEL Communications 3356P - page 24

    18 AT Command Set Sum maries ...

  • ZyXEL Communications 3356P - page 25

    Status Registers & Result Codes 19 5 Status Registers & Result Codes Register Dec. Function & Descriptio n Default S0= 0 - 255 Set the number of the rings required before the m odem automatically answers a call. Set “S0=0” to disable auto- answer mode. 000 S1= 0 - 255 Count the incoming rings and store the value to this register. Th ...

  • ZyXEL Communications 3356P - page 26

    20 Status Registers & Result Codes Register Dec. Function & Descriptio n Default 0, 2 Hang up. 1, 3 Fall back to an async connection. 4, 6 Attempt MNP mode. If MNP fails, hang up. 5, 7 Attempt MNP mode. If MNP fails, fallback to async connection.. S37= Desired DCE speed (line speed). 000 0 Maximum modem speed. 2 Attempt 1200/75 bps connecti ...

  • ZyXEL Communications 3356P - page 27

    Status Registers & Result Codes 21 Register Dec. Function & Descriptio n Default S36=0 or 2 and S48= 128 Don’t use S36=1 or 3, and S48=7 LAPM or async S36=1 or 3, and S48=128 Async S36=4 or 6, and S48=7 LAPM, MNP or hang up S36=4 or 6, and S48=128 MNP or hang up S36=5 or 7, and S48=7 LAPM, MNP or async S36=5 or 7, and S48=128 MNP or hang ...

  • ZyXEL Communications 3356P - page 28

    22 Status Registers & Result Codes ATV0 ATV1 X0 X1 X2 X3 X4 X7 58 CONNECT 28800 EC * # # # # 59 CONNECT 31200 EC * # # # # 60 CONNECT 33600 EC * # # # # 70 CONNECT 32000 EC * # # # # 71 CONNECT 34000 EC * # # # # 72 CONNECT 36000 EC * # # # # 73 CONNECT 38000 EC * # # # # 74 CONNECT 40000 EC * # # # # 75 CONNECT 42000 EC * # # # # 76 CONNECT 44 ...

  • ZyXEL Communications 3356P - page 29

    Status Registers & Result Codes 23 ATV0 ATV1 W0 W1 W2 W2V0 28 CONNECT 38400 EC * 99 40 CONNECT 300 99 40 CONNECT 300 EC * 99 55 CONNECT 21600 9 55 CONNECT 21600 EC * 9 56 CONNECT 24000 9 56 CONNECT 24000 EC * 9 57 CONNECT 26400 9 57 CONNECT 26400 EC * 9 58 CONNECT 28800 9 58 CONNECT 28800 EC * 9 59 CONNECT 31200 9 59 CONNECT 31200 EC* 9 60 CON ...

  • ZyXEL Communications 3356P - page 30

    24 Status Registers & Result Codes MNP4 MNP 4 error c ontrol only NoEC No error control and data control protocols ...

Manufacturer ZyXEL Communications Category Modem

Documents that we receive from a manufacturer of a ZyXEL Communications 3356P can be divided into several groups. They are, among others:
- ZyXEL Communications technical drawings
- 3356P manuals
- ZyXEL Communications product data sheets
- information booklets
- or energy labels ZyXEL Communications 3356P
All of them are important, but the most important information from the point of view of use of the device are in the user manual ZyXEL Communications 3356P.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals ZyXEL Communications 3356P, service manual, brief instructions and user manuals ZyXEL Communications 3356P. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product ZyXEL Communications 3356P.

A complete manual for the device ZyXEL Communications 3356P, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use ZyXEL Communications 3356P by users. Manuals are usually written by a technical writer, but in a language understandable to all users of ZyXEL Communications 3356P.

A complete ZyXEL Communications manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual ZyXEL Communications 3356P - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the ZyXEL Communications 3356P, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the ZyXEL Communications 3356P, that we can find in the current document
3. Tips how to use the basic functions of the device ZyXEL Communications 3356P - which should help us in our first steps of using ZyXEL Communications 3356P
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with ZyXEL Communications 3356P
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of ZyXEL Communications 3356P in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning ZyXEL Communications 3356P?

Use the form below

If you did not solve your problem by using a manual ZyXEL Communications 3356P, ask a question using the form below. If a user had a similar problem with ZyXEL Communications 3356P it is likely that he will want to share the way to solve it.

Copy the text from the picture