    Installation Manual 1550 UNIVERSAL BEER DISPENSER (R-404A REFRIGERANT) PRINTED IN U.S.A IMI CORNELIUS INC; 1998–99  IMI CORNELIUS INC g One Cornelius Place g Anoka, MN 55303-6234 T elephone (800) 238-3600 Facsimile (612) 422-3246 Part No. 569000246 August 1 1, 1998 Revised: June 1 1, 1999 Control Code A THIS DOCUMENT CONT AINS IMPOR T ANT INFO ...

  • Cornelius 1550 - page 2

    i 569000246 T ABLE OF CONTENTS Page SAFETY INFORMA TION 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RECOGNIZE SAFETY INFORMA TION 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UNDERST AND SIGNAL WORDS 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cornelius 1550 - page 3

    ii 569000246 T ABLE OF CONTENTS (cont ’ d) Page SERVICE AND MAINTENANCE 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PREP ARING UNIT FOR SHIPPING, RELOCA TING, OR ST ORING 15 . . . . . . . . . . ADJUSTMENTS 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cornelius 1550 - page 4

    1 569000246 SAFETY INFORMA TION Recognize Safety Information This is the safety-alert symbol. When you see this symbol on our machine or in this manual, be alert to the potentially of personal injury . Follow recommended precautions and safe operating practices. DANGER Understand Signal Words A signal word - DANGER, W ARNING, OR CAUTION is used wit ...

  • Cornelius 1550 - page 5

    ...

  • Cornelius 1550 - page 6

    2 569000246 THIS P AGE LEFT BLANK INTENTIONALL Y ...

  • Cornelius 1550 - page 7

    3 569000246 GENERAL INFORMA TION IMPORT ANT : T o the user of this manual – This manual is a guide for installing, operating, and main- taining this equipment. Refer to the T able of Contents for page location for detailed information per- taining to questions that arise during installation, operation, service, or maintenance of this equip- ment. ...

  • Cornelius 1550 - page 8

    4 569000246 T able 1. Design Data (cont ’ d) Electrical Requirements: Operating V oltage See Unit Nameplate Current Draw See Unit Nameplate THEOR Y OF OPERA TION ( see Figure 2 ) A CO 2 cylinder delivers carbon dioxide (CO 2 ) gas through adjustable CO 2 regulators to the beer kegs. When dispensing valves are opened, CO 2 gas pressure exerted upo ...

  • Cornelius 1550 - page 9

    5 569000246 CO 2 GAS CHECK V A L VE (2) BEER KEG (2) CO 2 CYLINDER LINE LEGEND BEER CO 2 PRIMAR Y CO 2 REGULA T OR BEER KEG SECONDARY CO 2 REGULA T OR (2) CO 2 SHUT OFF V A L VE (2) BEER KEG T APPER (2) 1 2 1550 UNIVERSAL BEER DISPENSER DISPENSING F AUCET (2) COIL NO. 1 COIL NO. 2 NO. 2 NO. 1 SEE NOTE 2 SEE NOTE 1 SYRUP T AN K CO 2 QUICK DISCONNECT ...

  • Cornelius 1550 - page 10

    ...

  • Cornelius 1550 - page 11

    6 569000246 THIS P AGE LEFT BLANK INTENTIONALL Y ...

  • Cornelius 1550 - page 12

    7 569000246 INST ALLA TION This section covers unpacking and inspection, selecting location, installing Unit, preparing for operation, and operation. UNP ACKING AND INSPECTION NOTE: The Unit was thoroughly inspected before leaving the factory and the carrier has accepted and signed for it. Any damage or irregularities should be noted at the time of ...

  • Cornelius 1550 - page 13

    8 569000246 2. The Unit must be installed near a properly grounded electrical outlet with proper electrical require- ments.The electrical circuit must be properly fused (slow-blow type fuse) or the circuit must be connected through an equivalent HACR circuit breaker .The electrical outlet must be accessible for ease of connecting and disconnecting ...

  • Cornelius 1550 - page 14

    9 569000246 6. Make sure the main power switch (1 15 V AC, 60 Hz Unit), located on back side of the Unit, is in the “ OFF ” (down) position. 7. Plug Unit power cord into electrical outlet. If Unit is 1 15 V AC, 60 Hz, place main power switch on back side of the Unit in “ ON ” position. 8. The compressor , condenser fan motor, and the agitat ...

  • Cornelius 1550 - page 15

    10 569000246 3. Open the CO 2 cylinder shutof f valve slightly to allow the primary CO 2 regulator to fill with gas, then open the valve fully to back-seat the valve. Back-seating the valve prevents leakage around the valve shaft. 4. Adjust the primary CO 2 regulator by loosening the regulator adjusting screw lock nut, then turn the adjust- ing scr ...

  • Cornelius 1550 - page 16

    569000246 11 OPERA T OR ’ S INSTRUCTIONS This section covers operating controls, pre-operation check, Unit operation, and maintenance procedures that may be performed by the Operator . IMPORTANT : Only qualified Personnel should service internal components of the Unit. PROPER BEER ST ORAGE Beer is a perishable product that can be materially chang ...

  • Cornelius 1550 - page 17

    569000246 12 BEER F AUCET (2) UNIT POWER SWITCH (1 15 V AC, 60 HZ UNIT ONL Y) DRIP TRA Y/CUP REST FIGURE 3. 1550 UNIVERSAL BEER DISPENSER OPERA TING CLEARANCES Check area in front, back, sides, and above the Unit for obstructions. These areas must be kept clear at all times. Listed below are the minimum clearances that must be maintained. A. Cleara ...

  • Cornelius 1550 - page 18

    569000246 13 An excessive accumulation of dust, lint, and grease on the condenser coil will restrict air flow through the coil which will decrease cooling efficiency of the Unit. The Unit condenser coil should be periodically cleaned to maintain cooling ef ficiency of the Unit. Contact a qualified Service Person to clean the Unit condenser coil. CH ...

  • Cornelius 1550 - page 19

    ...

  • Cornelius 1550 - page 20

    569000246 14 THIS P AGE LEFT BLANK INTENTIONALL Y ...

  • Cornelius 1550 - page 21

    569000246 15 SER VICE AND MAINTENANCE This section describes the service and maintenance procedures to be performed on the Unit. IMPORTANT : Only qualified Personnel should service the Unit internal components or electrical wiring. W ARNING: Disconnect electrical power from the Unit to prevent personnel injury before attempting any internal mainten ...

  • Cornelius 1550 - page 22

    569000246 16 UNIT BEER INLET LINES (2) POWER CORD T OP COVER BEER F AUCET (2) CUP REST DRIP TRA Y AIR INT AK E RET AINING SCREW (4) ACCESS GRILLE (4) DRIP TRA Y DRAIN HOSE W A TER T ANK OVERFLOW TUBE W A TER T ANK DRAIN HOSE PLUG COVER RET AINING SCREW (4) V A L VE TRIM P ANEL DRIP TRA Y DRAIN HOSE UNIT POWER SWITCH (1 15 V AC UNIT ONL Y) FIGURE 4. ...

  • Cornelius 1550 - page 23

    569000246 17 BEER INLET LINES (2) ELECTRICAL CONTROL BOX POWER CORD RET AINING SCREW TERMINAL BLOCK CONDENSER COIL UNIT POWER SWITCH (1 15 V AC UNIT ONL Y ) COMPRESSOR CONDENSER F AN MOTOR ACCESS GRILLE FIGURE 5. P ARTS IDENTIFICA TION ...

  • Cornelius 1550 - page 24

    569000246 18 Adjusting Beer Kegs Secondary CO 2 Regulators. Beer kegs secondary CO 2 regulators pressures adjustments require calculations of each beer system total beer system pressure. T otal beer system pressure, required to push beer from keg to faucet, is the result of comput- ing length of beer line of a certain size, vertical line lift, and ...

  • Cornelius 1550 - page 25

    569000246 19 2. Remove four screws securing air intake grille on the Unit front panel, then remove the grille. 3. V acuum or use a soft brush to clean the condenser coil. If available, use low-pressure compressed air . 4. Install air intake grille on the Unit and secure with four screws. 5. Plug Unit power cord into electrical outlet. CHECKING ICE ...

  • Cornelius 1550 - page 26

    569000246 20 8. Using a fiber brush, carefully clean mineral deposit build-up from the agitator motor shaft and the ice bank sensing bulb. 9. Rinse all parts and flush water tank with clean water . 10. Install plug in end of the water tank drain hose, then place drain hose back inside the Unit. 1 1. Place end of the Unit water tank overflow tube in ...

  • Cornelius 1550 - page 27

    569000246 21 5. Connect tank containing detergent solution into the beer system. 6. Place waste container under applicable beer faucet. 7. Activate the beer faucet to permit detergent solution to purge beer out of the line, coil, and the beer faucet. Continue to dispense until all beer has been purged from the beer system and only detergent solutio ...

  • Cornelius 1550 - page 28

    569000246 22 W ARNING: CO 2 displaces oxygen. Strict attention must be observed in the prevention of CO 2 (carbon dioxide) gas leaks in the entire CO 2 and soft drink system. If a CO 2 gas leak is suspected, particularly in a small area, immediately ventilate the contaminated area before attempting to repair the leak. Personnel exposed to high conc ...

  • Cornelius 1550 - page 29

    569000246 23 CLEANING CO 2 GAS CHECK V AL VE (see Figures 2 and 7) CO 2 gas check valves must be inspected and serviced at least once a year under normal conditions and after any servicing or disruption of the CO 2 system. AL WA YS REPLACE QUAD RING SEALS EACH TIME CHECK V AL VES ARE SER VICED. ...

  • Cornelius 1550 - page 30

    569000246 24 FIGURE 8. WIRING DIAGRAM ...

  • Cornelius 1550 - page 31

    25 569000246 TROUBLESHOOTING IMPORTANT : Only qualified Personnel should service internal components or electrical wiring. W ARNING: If repairs are to be made to the beer system, close shutoff valve in applicable beer inlet line, then relieve system pressure before proceeding. If repairs are to be made to the CO 2 system, shut off CO 2 supply , shu ...

  • Cornelius 1550 - page 32

    26 569000246 T rouble Remedy Probable Cause DISPENSED BEER FLOW RA TE T OO HIGH. A. Beer faucet not properly adjusted for beer flow rate. A. Adjust dispensed beer flow rate as instructed. OFF-TASTE BEER (SOUR AND UNP ALA T ABLE). A. Beer system needs to be cleaned and sanitized. A. Clean and sanitize beer system as instructed. B. Beer spoilage (sec ...

  • Cornelius 1550 - page 33

    27 569000246 T rouble Probable Cause Remedy TROUBLESHOOTING COOLING UNIT REFRIGERA TION SYSTEM COMPRESSOR DOES NOT OPERA TE. A. Glycol (coolant) sufficiently cooled. A. Refrigeration not called for . B. Cooling Unit POWER switch in ‘‘ OFF ’’ (down) position. B. Place Cooling Unit POWER switch in ‘‘ ON ’’ (up) position. C. No power s ...

  • Cornelius 1550 - page 34

    28 569000246 T rouble Remedy Probable Cause REFRIGERA TION COMPRESSOR NOT OPERA TING A. Refrigeration system overheated. Clogged condenser coil air intake filter . A. Clean air filter as instructed. B. Refrigeration system overheated. Condenser fan motor not operating. B. Replace condenser fan motor . C. Glycol tank temperature control sensor inope ...

  • Cornelius 1550 - page 35

    29 569000246 IMI CORNELIUS INC . O NE C ORNELIUS P LACE A NOKA, MN . 55303 – 6234 T ELEPHONE ( 800) 238 – 3600 F ACSIMILE (612) 422 – 3232 W ARRANTY IMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workman- ship under normal use and service. For a copy of the warranty applicable to your Cornelius ...

  • Cornelius 1550 - page 36

    IMI CORNELIUS INC. CORPORA TE HEADQUARTERS: One Cornelius Place Anoka, Minnesota 55303-6234 (612) 421-6120 (800) 238-3600 301 137000 ...

Manufacturer Cornelius Category Beverage Dispenser

Documents that we receive from a manufacturer of a Cornelius 1550 can be divided into several groups. They are, among others:
- Cornelius technical drawings
- 1550 manuals
- Cornelius product data sheets
- information booklets
- or energy labels Cornelius 1550
All of them are important, but the most important information from the point of view of use of the device are in the user manual Cornelius 1550.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Cornelius 1550, service manual, brief instructions and user manuals Cornelius 1550. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Cornelius 1550.

Similar manuals

A complete manual for the device Cornelius 1550, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Cornelius 1550 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Cornelius 1550.

A complete Cornelius manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Cornelius 1550 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Cornelius 1550, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Cornelius 1550, that we can find in the current document
3. Tips how to use the basic functions of the device Cornelius 1550 - which should help us in our first steps of using Cornelius 1550
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Cornelius 1550
5. FAQ - Frequently Asked Questions