Manual Patton electronic 1001MC

288 pages 10.4 mb
Download

Go to site of 288

Summary
  • Patton electronic 1001MC - page 1

    Model 1001MC NetLink™ SNMP Management Card Operations Guide Sales Office: +1 (301) 975-1000 T echnical Support: +1 (301) 975-1007 E-mail: support@patton.com WWW : www .patton.com Document Number: 022021U Rev . F Part Number: 07M1001MC Revised: May 19, 2008 ...

  • Patton electronic 1001MC - page 2

    Patton Electronics Company , Inc. 7622 Rickenbacker Drive Gaithersburg, MD 20879 USA tel: +1 (301) 975-1000 fax: +1 (301) 869-9293 support: +1 (301) 975-1007 url: www .patton.com e-mail: support@patton.com Copyright Statement Copyright © 2008, P atton Electronics Company . All rights reserved. T rademark Statement The terms N etLink , KiloModem , ...

  • Patton electronic 1001MC - page 3

    3 Contents About this guide .....................................................................................................................................................6 Audience ................................................................................................................................................................. ...

  • Patton electronic 1001MC - page 4

    4 Model 1001MC Operations Guide Contents Using the Download page to upgrade 1094ARC software .....................................................................................87 6 Model 1095RC management ......................................................................................................................... 89 Introduction ..... ...

  • Patton electronic 1001MC - page 5

    5 Model 1001MC Operations Guide Contents Download ............................................................................................................................................................249 System Log ................................................................................................................................. ...

  • Patton electronic 1001MC - page 6

    6 About this guide This guide describes installing and operating a P atton Electronics 1001MC N etLink™ SNMP Management Card. This section describes the following: • Who should use this guide (see “ Audience ” ) • Ho w this document is organized (see “S tructure ” ) • T ypographical conventions and terms used in this guide (see “T ...

  • Patton electronic 1001MC - page 7

    About this guide Model 1001MC Operations Guide 7 T ypographical conventions used in this document This section describes the typographical conventions and terms used in this guide. General conventions The procedures described in this manual use the follo wing text conventions: T able 1. T ext conventions Convention Meaning Garamond blue type Indica ...

  • Patton electronic 1001MC - page 8

    Additional References 8 Model 1001MC Operations Guide About this guide Mouse conventions The following conventions ar e used when describing mouse actions: Additional References The P atton Electronics website (www .patton.com) pro vides 1001MC and N etLink modem application notes, which includes F AQ, startup notes, and test setups. RFCs U se a we ...

  • Patton electronic 1001MC - page 9

    About this guide Model 1001MC Operations Guide 9 Technical support Service All warranty and non-warranty repairs must be returned fr eight prepaid and insured to P atton Electronics. All returns must have a R eturn Materials A uthorization number on the outside of the shipping container . This number may be obtained from P atton Electronics T echni ...

  • Patton electronic 1001MC - page 10

    10 Chapter 1 Introduction Chapter contents Introduction ..........................................................................................................................................................11 Model 1001MC management overview ........................................................................................................ ...

  • Patton electronic 1001MC - page 11

    Introduction 11 Model 1001MC Operations Guide 1 • Introduction Introduction The M odel 1001MC N etLink™ SNMP Management Car d (see figure 1 ) enables an SNMP workstation to configure and monitor multiple P atton N etLink cards racks and their connected standalone units. Figure 1. Model 1001MC NetLink Management Card The management card has th ...

  • Patton electronic 1001MC - page 12

    Introduction 12 Model 1001MC Operations Guide 1 • Introduction - M odel 3088R C G.SHDSL V .35 - M34 - M odel 3088R C G.SHDSL X.21 - DB15 - M odel 3088R C G.SHDSL E1 - Dual BNC & RJ-45 - M odel 3088R C G.SHDSL E thernet BR - RJ-45 Note Y our specific model of 1001MC may not suppor t all of the models listed above. The 1001MC front and rear ca ...

  • Patton electronic 1001MC - page 13

    Introduction 13 Model 1001MC Operations Guide 1 • Introduction Figure 3. Model 1001R14/16 Rack Chassis with power supply ...

  • Patton electronic 1001MC - page 14

    Model 1001MC management overview 14 Model 1001MC Operations Guide 1 • Introduction Model 1001MC management overview The M odel 1001MC uses a 10Base-T E thernet port to connect to a local LAN (or to any location in the world via the Internet). M anagement can be performed using any SNMP station or web browser with the internal HTTP/HTML management ...

  • Patton electronic 1001MC - page 15

    15 Chapter 2 Hardware installation Chapter contents Introduction ..........................................................................................................................................................17 Before you install… .......................................................................................................... ...

  • Patton electronic 1001MC - page 16

    16 Model 1001MC Operations Guide 2 • Hardware installation Installing the Ethernet cable ............................................................................................................................32 Connecting a 10Base-T hub to the 1001MC ............................................................................................ ...

  • Patton electronic 1001MC - page 17

    Introduction 17 Model 1001MC Operations Guide 2 • Hardware installation Introduction M odel 1001MC installation consists of the following: • Installing the front and r ear cards into the rack chassis (see section “I nstalling the M odel 1001MC into the rack chassis ” on page 18) • Configuring and installing the N etLink modem cards (see ...

  • Patton electronic 1001MC - page 18

    Installing the Model 1001MC into the rack chassis 18 Model 1001MC Operations Guide 2 • Hardware installation Figure 5. Rack chassis slot layout (rear view) Installing the Model 1001MC into the rack chassis The M odel 1001MC consists of a front rack card and a r ear input/output (I/O) card (see figur e 2 on page 12). The two cards meet inside the ...

  • Patton electronic 1001MC - page 19

    Installing NetLink modem cards 19 Model 1001MC Operations Guide 2 • Hardware installation 3. Slide the front rack car d into the front chassis slot 14 (see figure 6 ) until it meets the r ear card r eceptacle. When that happens, push the front card gently but firmly into the car d-edge receptacle of the r ear card, it should click into place. F ...

  • Patton electronic 1001MC - page 20

    Installing NetLink modem cards 20 Model 1001MC Operations Guide 2 • Hardware installation 100-ohm resistor . This is done by configuring a jumper on the modem ’ s rear I/O card. R efer to the installation manual that came with the rack card for mor e information on this jumper setting. Setting the 1092ARC system address The manual that was shi ...

  • Patton electronic 1001MC - page 21

    Installing NetLink modem cards 21 Model 1001MC Operations Guide 2 • Hardware installation from the pow er supplies) and increment the numbers by one as you go fr om left to right. Setting the addresses in this manner will make configuration easier as you start using the web page management. An example of this is shown belo w . 1 - 2 - 3 - 4 - 5 ...

  • Patton electronic 1001MC - page 22

    Installing NetLink modem cards 22 Model 1001MC Operations Guide 2 • Hardware installation Hardware setup for a Model 1094ARC The following must be done to configure y our M odel 1094AR C hardwar e for use with the M odel 1001MC network management station: • Connect frame ground to signal ground (see section “Configuring frame ground ” ) ? ...

  • Patton electronic 1001MC - page 23

    Installing NetLink modem cards 23 Model 1001MC Operations Guide 2 • Hardware installation address 1 to address 13. The 1001MC will then begin polling rack #2 on the daisy chain por t starting from address 14. The daisy chained racks are set up in the same manner with 13 addresses being av ailable in a redundant system and 15 addresses being avail ...

  • Patton electronic 1001MC - page 24

    Installing NetLink modem cards 24 Model 1001MC Operations Guide 2 • Hardware installation Hardware setup for a Model 1095RC The following must be done to configure y our M odel 1095R C hardwar e for use with the M odel 1001MC net- work management station: • Connect frame ground to signal ground (see section “Configuring frame ground ” ) ? ...

  • Patton electronic 1001MC - page 25

    Installing NetLink modem cards 25 Model 1001MC Operations Guide 2 • Hardware installation U sing this information, the M odel 1001MC will poll the specified address range in each rack. Thus, in a single power supply system, the addr ess range for rack #1 (the rack with the 1001MC installed) will be from address 1 to address 15 Note The 1001MC is ...

  • Patton electronic 1001MC - page 26

    Installing NetLink modem cards 26 Model 1001MC Operations Guide 2 • Hardware installation T able 7 shows the bit setting to configure the addr ess. T able 8 shows examples of address settings. Hardware setup for a Model 2701RC The following must be done to configure y our M odel 2701R C hardwar e for use with the M odel 1001MC net- work managem ...

  • Patton electronic 1001MC - page 27

    Installing NetLink modem cards 27 Model 1001MC Operations Guide 2 • Hardware installation Setting the 2701RC system address The manual that was shipped with your N etLink-E1 unit specifies switch S3 for the card address in the N etLink System. Each car d in the chassis is given a unique address thr ough the setting of switch S3. Note S tandalone ...

  • Patton electronic 1001MC - page 28

    Installing NetLink modem cards 28 Model 1001MC Operations Guide 2 • Hardware installation 1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 - 11 - 12 - 13 - NMS - PS2 - PS1 F igure 7 sho ws the bit setting to configure the address. T able 9 shows examples of address settings. Figure 7. Bit setting to configure the address Hardware setup for a Model 2707RC ...

  • Patton electronic 1001MC - page 29

    Installing NetLink modem cards 29 Model 1001MC Operations Guide 2 • Hardware installation Hardware setup for a Model 2710RC The following must be done to configure y our M odel 2710R C hardwar e for use with the M odel 1001MC net- work management station: • Connect frame ground to signal ground (see section “Configuring frame ground ” ) W ...

  • Patton electronic 1001MC - page 30

    Installing NetLink modem cards 30 Model 1001MC Operations Guide 2 • Hardware installation Note S tandalone units use the address of the rack card that they ar e con- nected to. P olling ov erview . The Model 1001MC sends “ poll” messages along the internal bus looking for cards installed in the system. Once a card is found it is placed “ on ...

  • Patton electronic 1001MC - page 31

    Installing the power supplies 31 Model 1001MC Operations Guide 2 • Hardware installation F igure 7 sho ws the bit setting to configure the address. T able 9 shows examples of address settings. Figure 8. Bit setting to configure the address Installing the power supplies Refer to the installation manual that came with the po wer supply (or suppli ...

  • Patton electronic 1001MC - page 32

    Connecting the cables 32 Model 1001MC Operations Guide 2 • Hardware installation Connecting the cables Installing 1001MC rear I/O car d cables takes place in the following order: 1. Installing the 10B ase-T Ethernet cable onto the 10B ase-T port (see figure 9 ) (see “Installing the E thernet cable ” on page 32). 2. Installing the cable onto ...

  • Patton electronic 1001MC - page 33

    Connecting the cables 33 Model 1001MC Operations Guide 2 • Hardware installation Connecting a 10Base-T hub to the 1001MC The Ethernet 10B ase-T port on the rear of the 1001MC connects directly to a 10B ase-T hub or repeater using RJ-45 unshielded twisted-pair cable that is wired straight-through (see figur e 11 ). Note Cable lengths should not e ...

  • Patton electronic 1001MC - page 34

    LED indicators 34 Model 1001MC Operations Guide 2 • Hardware installation Installing the RS-232 configuration/daisy-chain port cable The DB-25 connector is a DTE-configured RS-232 port that is used to set up your IP address, subnet mask, and default configuration. After the system is set up, the configuration port can be used to connect to a ...

  • Patton electronic 1001MC - page 35

    Where to go next 35 Model 1001MC Operations Guide 2 • Hardware installation Ethernet LED indicators The Ethernet LEDs conv ey transmit and receive data activity as well as the status of the link (see table 11 ). Power LED indicator The power LED sho ws the power status of the M odel 1001MC (see table 12 ). Heartbeat LED indicator Fault LED indica ...

  • Patton electronic 1001MC - page 36

    36 Chapter 3 Getting star ted Chapter contents Introduction ..........................................................................................................................................................37 Booting the Model 1001MC ............................................................................................................ ...

  • Patton electronic 1001MC - page 37

    Introduction 37 Model 1001MC Operations Guide 3 • Getting started Introduction T o complete this section you will need the following: • a VT -100 terminal or terminal emulator • a null-modem cable • an IP address for your box • a subnet mask for your box • the IP address of the default gateway for your LAN Booting the Model 1001MC Note ...

  • Patton electronic 1001MC - page 38

    Booting the Model 1001MC 38 Model 1001MC Operations Guide 3 • Getting started 5. After pressing the b key three times the system will display the following: Timer Started May 11 1999 14:44:24 Timer installed Clock installed Trying the console ---Ethernet Hardware--- Address: 00.a0.ba.00.01.71 ---Current IP settings--- IP:192.168.200.1 Mask:255.25 ...

  • Patton electronic 1001MC - page 39

    Installing the Model 1001MC RS-232 daisy-chain port cable 39 Model 1001MC Operations Guide 3 • Getting started Note T o RESET to factor y configuration the user must type e three times anytime during the boot sequence upon power-up . The console will display the following messages: Are you sure you want to erase current configuration (y/n)?y If ...

  • Patton electronic 1001MC - page 40

    Installing the Model 1001MC RS-232 daisy-chain port cable 40 Model 1001MC Operations Guide 3 • Getting started Figure 15. Configuring a daisy-chain network Setting the address range for your NetLink modems The M odel 1001MC polls the system looking for N etLink modems. If the address of the N etLink modem is not configured or does not match the ...

  • Patton electronic 1001MC - page 41

    Introduction to the internal HTTP/HTML management pages 41 Model 1001MC Operations Guide 3 • Getting started The 1001MC will then begin polling rack #2 on the daisy chain port starting from address 16. in a redundant power supply system, the addr ess range for rack #1 (the rack with the 1001MC installed) will be from address 1 to address 13. The ...

  • Patton electronic 1001MC - page 42

    Saving HTTP/HTML object changes 42 Model 1001MC Operations Guide 3 • Getting started HTTP/HTML and SNMP object format In this document, we shall describe the v ariables found on each of the internal HTTP/HTML pages. This description will include brief definitions of the P atton Enterprise MIB or SNMP MIB II object identifiers wherever applicabl ...

  • Patton electronic 1001MC - page 43

    Saving HTTP/HTML object changes 43 Model 1001MC Operations Guide 3 • Getting started Figure 18. 1001MC command map ...

  • Patton electronic 1001MC - page 44

    Saving HTTP/HTML object changes 44 Model 1001MC Operations Guide 3 • Getting started After logging in, the system displays the HOME page (see figure 19 ). Figure 19. HOME page Home The HOME page displays a quick overview of the system including; error and warning indications, software information, box names, number of modems installed, and so on ...

  • Patton electronic 1001MC - page 45

    Saving HTTP/HTML object changes 45 Model 1001MC Operations Guide 3 • Getting started Configure Cards Clicking on the Configure Cards hyperlink displays the System Level Infor mation page. This page is the starting point for the configuration and management of your P atton NetLink modems. This page enables you to quickly identify potential prob ...

  • Patton electronic 1001MC - page 46

    Where to go next… 46 Model 1001MC Operations Guide 3 • Getting started Where to go next… Refer to the follo wing chapters as appropriate to manage the modem rack cards installed in your M odel 1001 rack chassis: • Chapter 4, “M odel 1092AR C management ” on page 47 • Chapter 5, “M odel 1094AR C management ” on page 67 • Chapter ...

  • Patton electronic 1001MC - page 47

    47 Chapter 4 Model 1092ARC management Chapter contents Introduction ..........................................................................................................................................................49 NetLink-NMS description ..................................................................................................... ...

  • Patton electronic 1001MC - page 48

    48 Model 1001MC Operations Guide 4 • Model 1092ARC management HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL) ................................................................62 SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL) ...................................................................62 Software Rev (softVersioniDSL/remotesoftver ...

  • Patton electronic 1001MC - page 49

    Introduction 49 Model 1001MC Operations Guide 4 • Model 1092ARC management Introduction This chapter describes managing a M odel 1092AR C N etLink iDSL modem using the Model 1001MC N etLink-NMS internal HTTP/HTML web engine and a standard web bro wser . This chapter is meant to be used in addition to the manual that came with your unit. NetLink-N ...

  • Patton electronic 1001MC - page 50

    Configuration and management 50 Model 1001MC Operations Guide 4 • Model 1092ARC management Displaying the Modem Information page The Modem Information page (see figure 20 ) displays the car ds installed in the system and a quick view of any errors or warnings associated with your modems. Figure 20. Modem Information page for the Model 1092ARC S ...

  • Patton electronic 1001MC - page 51

    Configuration and management 51 Model 1001MC Operations Guide 4 • Model 1092ARC management Figure 21. W eb page navigation to Modem Infor mation page ...

  • Patton electronic 1001MC - page 52

    Configuration and management 52 Model 1001MC Operations Guide 4 • Model 1092ARC management Displaying the Model 1092 Configuration Slot page The Model 1092 Configuration Slot page (see figure 22 ) enables you to make configuration changes to the M odel 1092A and the remote CPE bo x. When the page displays, the unit is set to the onLine state ...

  • Patton electronic 1001MC - page 53

    Configuration and management 53 Model 1001MC Operations Guide 4 • Model 1092ARC management Figure 23. W eb page navigation to Model 1092 Configuration Slot page Making configuration changes to your 1092ARC NetLink modem Do use the follo wing to make configuration changes to your N etLink modem. Note Y ou must be logged in as super user to perf ...

  • Patton electronic 1001MC - page 54

    Configuration and management 54 Model 1001MC Operations Guide 4 • Model 1092ARC management Displaying the Model 1092 Configuration—Next Configuration page The Model 1092 Configuration—Next Configuration page (see figure 24 ) enables you to make configuration changes to the M odel 1092A and the remote CPE bo x. When the page displays, th ...

  • Patton electronic 1001MC - page 55

    Configuration and management 55 Model 1001MC Operations Guide 4 • Model 1092ARC management Figure 25. W eb page navigation to Model 1092 Configuration—Next Configuration page ...

  • Patton electronic 1001MC - page 56

    Configuration and management 56 Model 1001MC Operations Guide 4 • Model 1092ARC management Displaying the Slot Configuration page The Slot Configuration page (see figure 26 ) is used to set slot-specific information related to the system and ho w the system treats that slot in the case of errors or warnings. Figure 26. Slot Configuration pag ...

  • Patton electronic 1001MC - page 57

    Modem Information page MIB variables description 57 Model 1001MC Operations Guide 4 • Model 1092ARC management Figure 27. W eb page navigation to Slot Configuration page F or more information about items on the Slot Configuration page, see “Slot Configuration page MIB variables description ” on page 65. Modem Information page MIB variables ...

  • Patton electronic 1001MC - page 58

    Modem Information page MIB variables description 58 Model 1001MC Operations Guide 4 • Model 1092ARC management Note Setting the Rack P rotection Mode to normal(0) will enable the rack to receive new configurations through the global configuration command. Submit button After you have defined the number of po wer supplies installed in the rack ...

  • Patton electronic 1001MC - page 59

    Modem Information page MIB variables description 59 Model 1001MC Operations Guide 4 • Model 1092ARC management • testM ode(3) W arnings (warningCount) This field displays the warnings that are associated with each modem installed in the system. When warnings are present, this field will be highlighted in y ellow and the number of warnings wil ...

  • Patton electronic 1001MC - page 60

    Modem Information page MIB variables description 60 Model 1001MC Operations Guide 4 • Model 1092ARC management rack card will then update the M odel 1001MC. For this r eason this information will not be available until after the link is made between the two modems. Protected Note F or Model 1095R C and Model 2701R C. Y ou can protect individual r ...

  • Patton electronic 1001MC - page 61

    Model 1092 Configuration Slot page MIB variables description 61 Model 1001MC Operations Guide 4 • Model 1092ARC management Model 1092 Configuration Slot page MIB variables description This section describes the MIB variables that are available on the Model 1092 Configuration Slot page. Model 1092A Model 1092 Configuration Slot (nmsSlotID) Disp ...

  • Patton electronic 1001MC - page 62

    Model 1092 Configuration Slot page MIB variables description 62 Model 1001MC Operations Guide 4 • Model 1092ARC management configuration space. If this is not done, the N etLink-iDSL will not recognize the configuration changes that were made. Model 1092 Configuration Slot page Configuration Status table description The Configur ation Status ...

  • Patton electronic 1001MC - page 63

    Model 1092 Configuration—Next Configuration page MIB variables description 63 Model 1001MC Operations Guide 4 • Model 1092ARC management Software Rev (softV ersioniDSL/remotesoftversioniDSL) These read-only MIB variables display the curr ent version of code that is running in the N etLink-iDSL modems. Check the Do wnload page to see if the Mode ...

  • Patton electronic 1001MC - page 64

    Model 1092 Configuration—Next Configuration page MIB variables description 64 Model 1001MC Operations Guide 4 • Model 1092ARC management At startup, all of the fields will be highlighted in yello w , signifying that they are not verified parameters. As the N etLink-iDSL sets up the parameters, the highlighting disappears, signifying that the ...

  • Patton electronic 1001MC - page 65

    Slot Configuration page MIB variables description 65 Model 1001MC Operations Guide 4 • Model 1092ARC management Submit Quer y button After making configuration changes, select the Back link, then select onLine , and finally , select Submit Query . This will submit all the configuration information to the M odel 1001MC. After this, the informat ...

  • Patton electronic 1001MC - page 66

    Slot Configuration page MIB variables description 66 Model 1001MC Operations Guide 4 • Model 1092ARC management Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-v olatile flash within the M odel 1001MC. Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-v olatile ...

  • Patton electronic 1001MC - page 67

    67 Chapter 5 Model 1094ARC management Chapter contents Introduction ..........................................................................................................................................................69 NetLink-NMS description ..................................................................................................... ...

  • Patton electronic 1001MC - page 68

    68 Model 1001MC Operations Guide 5 • Model 1094ARC management TM From DTE (dteTM1094/remotedteTM1094) ...................................................................................83 HW Test Mode (testModeInd1094/remotetestModeInd1094) .................................................................83 SW Test Mode (testModeSet1094/remotetes ...

  • Patton electronic 1001MC - page 69

    Introduction 69 Model 1001MC Operations Guide 5 • Model 1094ARC management Introduction This chapter describes managing a M odel 1094AR C N etLink HDSL modem using the Model 1001MC N etLink-NMS internal HTTP/HTML web engine and a standard web bro wser . This chapter is meant to be used in addition to the manual that came with your unit. NetLink-N ...

  • Patton electronic 1001MC - page 70

    Configuration and management 70 Model 1001MC Operations Guide 5 • Model 1094ARC management Displaying the Modem Information page The Modem Information page (see figure 28 ) displays the car ds installed in the system and a quick view of any errors or warnings associated with your modems. Figure 28. Modem Information page for the Model 1094ARC S ...

  • Patton electronic 1001MC - page 71

    Configuration and management 71 Model 1001MC Operations Guide 5 • Model 1094ARC management Figure 29. W eb page navigation to Modem Infor mation page ...

  • Patton electronic 1001MC - page 72

    Configuration and management 72 Model 1001MC Operations Guide 5 • Model 1094ARC management Displaying the Model 1094 Configuration Slot page The Model 1094 Configuration Slot page (see figure 30 ) enables you to make configuration changes to the M odel 1094A and the remote CPE bo x. When the page displays, the unit is set to the onLine state ...

  • Patton electronic 1001MC - page 73

    Configuration and management 73 Model 1001MC Operations Guide 5 • Model 1094ARC management Figure 31. W eb page navigation to Model 1094 Configuration Slot page Making configuration changes to your 1094ARC NetLink modem Do use the follo wing to make configuration changes to your N etLink modem. Note Y ou must be logged in as super user to perf ...

  • Patton electronic 1001MC - page 74

    Configuration and management 74 Model 1001MC Operations Guide 5 • Model 1094ARC management Displaying the Model 1094 Configuration—Next Configuration page The Model 1094 Configuration—Next Configuration page (see figure 32 ) enables you to make configuration changes to the M odel 1094A and the remote CPE bo x. When the page displays, th ...

  • Patton electronic 1001MC - page 75

    Configuration and management 75 Model 1001MC Operations Guide 5 • Model 1094ARC management Figure 33. W eb page navigation to Model 1094 Configuration—Next Configuration page ...

  • Patton electronic 1001MC - page 76

    Configuration and management 76 Model 1001MC Operations Guide 5 • Model 1094ARC management Displaying the Slot Configuration page The Slot Configuration page (see figure 34 ) is used to set slot-specific information related to the system and ho w the system treats that slot in the case of errors or warnings. Figure 34. Slot Configuration pag ...

  • Patton electronic 1001MC - page 77

    Configuration and management 77 Model 1001MC Operations Guide 5 • Model 1094ARC management Figure 35. W eb page navigation to Slot Configuration page F or more information about items on the Slot Configuration page, see “Slot Configuration page MIB variables description ” on page 86. Displaying the Download page The Download page (see fig ...

  • Patton electronic 1001MC - page 78

    Modem Information page MIB variables description 78 Model 1001MC Operations Guide 5 • Model 1094ARC management S tarting from the HOME page, to access the Download page for the 1094ARC, click on the Download link. F igure 37 sho ws the web page navigation requir ed to get to this area of the system. Figure 37. W eb page navigation to Download pag ...

  • Patton electronic 1001MC - page 79

    Modem Information page MIB variables description 79 Model 1001MC Operations Guide 5 • Model 1094ARC management Note Setting the Rack P rotection Mode to normal(0) will enable the rack to receive new configurations through the global configuration command. Submit button After you have defined the number of po wer supplies installed in the rack ...

  • Patton electronic 1001MC - page 80

    Modem Information page MIB variables description 80 Model 1001MC Operations Guide 5 • Model 1094ARC management • testM ode(3) W arnings (warningCount) This field displays the warnings that are associated with each modem installed in the system. When warnings are present, this field will be highlighted in y ellow and the number of warnings wil ...

  • Patton electronic 1001MC - page 81

    Model 1094 Configuration Slot page MIB variables description 81 Model 1001MC Operations Guide 5 • Model 1094ARC management rack card will then update the M odel 1001MC. For this r eason this information will not be available until after the link is made between the two modems. Protected Y ou can protect individual rack cards from being globally c ...

  • Patton electronic 1001MC - page 82

    Model 1094 Configuration Slot page MIB variables description 82 Model 1001MC Operations Guide 5 • Model 1094ARC management Line Status (lineStatus1094) Displays the status of the line. There are thr ee possible values that can be displayed: • startup(1) • dataM ode(2) • testM ode(3) When the line status is dataM ode(2), the units are linked ...

  • Patton electronic 1001MC - page 83

    Model 1094 Configuration Slot page MIB variables description 83 Model 1001MC Operations Guide 5 • Model 1094ARC management the N etLink-HDSL modem will update the configuration in the M odel 1001MC with its last set of stored parameters. As these fields are updated in the M odel 1001MC, the yello w highlighting will disappear , signi- fying tha ...

  • Patton electronic 1001MC - page 84

    Model 1094 Configuration—Next Configuration page MIB variables description 84 Model 1001MC Operations Guide 5 • Model 1094ARC management Model 1094 Configuration—Next Configuration page MIB variables description The Model 1094 Configuration—Next Configuration page enables you to update the configuration of the 1094AR C NetLink-HDSL mod ...

  • Patton electronic 1001MC - page 85

    Model 1094 Configuration—Next Configuration page MIB variables description 85 Model 1001MC Operations Guide 5 • Model 1094ARC management Remote Software Rev (remotesoftversion1094) These read-only MIB variable displays the curr ent version of code that is running in the N etLink-HDSL Cus- tomer P remise modem. Y ou can update the software in th ...

  • Patton electronic 1001MC - page 86

    Slot Configuration page MIB variables description 86 Model 1001MC Operations Guide 5 • Model 1094ARC management in volatile RAM until you place the I nput Mode to onLine(0). This will tell the 1001MC to copy all of the configuration information into the N etLink-HDSL configuration space. Clear Changes Once configuration changes have been made ...

  • Patton electronic 1001MC - page 87

    Using the Download page to upgrade 1094ARC software 87 Model 1001MC Operations Guide 5 • Model 1094ARC management Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-v olatile flash within the M odel 1001MC. Alarm Information Clear Slot Alarms (resetStatus) Selecting this push button erases the alarms (er ...

  • Patton electronic 1001MC - page 88

    Using the Download page to upgrade 1094ARC software 88 Model 1001MC Operations Guide 5 • Model 1094ARC management 4. Click on the Download 1094ARC Software button (see figur e 38 ). Figure 38. Download 1094ARC software button Note Do not install the unit into the rack until you hav e selected the soft- ware that you want to do wnload. 5. Select ...

  • Patton electronic 1001MC - page 89

    89 Chapter 6 Model 1095RC management Chapter contents Introduction ..........................................................................................................................................................92 NetLink-NMS description ...................................................................................................... ...

  • Patton electronic 1001MC - page 90

    90 Model 1001MC Operations Guide 6 • Model 1095RC management Input Mode (mode1095) ..............................................................................................................................106 Model 1095 Configuration Slot page Configuration Status table description ................................................106 Model Cod ...

  • Patton electronic 1001MC - page 91

    91 Model 1001MC Operations Guide 6 • Model 1095RC management Protecting Model 1001 racks and Model 1095RC modems from global modification ..................................113 Protecting a Model 1001 rack from global configuration ........................................................................114 Protecting a Model 1095RC rack card from ...

  • Patton electronic 1001MC - page 92

    Introduction 92 Model 1001MC Operations Guide 6 • Model 1095RC management Introduction This chapter describes managing a M odel 1095R C N etLink mDSL modem using the Model 1001MC N etLink-NMS internal HTTP/HTML web engine and a standard web bro wser . This chapter is meant to be used in addition to the manual that came with your unit. NetLink-NMS ...

  • Patton electronic 1001MC - page 93

    Configuration and management 93 Model 1001MC Operations Guide 6 • Model 1095RC management Displaying the Global Configuration Menu page The Global Configuration Menu page (see figure 40 ) is where y ou can create templates that can globally config- ure the M odel 1095R C. With this capability , you can globally configure some or all Model 10 ...

  • Patton electronic 1001MC - page 94

    Configuration and management 94 Model 1001MC Operations Guide 6 • Model 1095RC management Displaying the Modem Information page The Modem Information page (see figure 42 ) displays the car ds installed in the system and a quick view of any errors or warnings associated with your modems. Figure 42. Modem Information page for the Model 1095RC S ta ...

  • Patton electronic 1001MC - page 95

    Configuration and management 95 Model 1001MC Operations Guide 6 • Model 1095RC management Displaying the Model 1095 Configuration Slot page The Model 1095 Configuration Slot page (see figure 44 ) enables you to make configuration changes to the M odel 1095R C and the remote CP E box. When the page displays, the unit is set to the onLine state ...

  • Patton electronic 1001MC - page 96

    Configuration and management 96 Model 1001MC Operations Guide 6 • Model 1095RC management Figure 45. W eb page navigation to Model 1095 Configuration Slot page Making configuration changes to your 1095RC NetLink modem Do use the follo wing to make configuration changes to your N etLink modem. Note Y ou must be logged in as super user to perfor ...

  • Patton electronic 1001MC - page 97

    Configuration and management 97 Model 1001MC Operations Guide 6 • Model 1095RC management Displaying the Model 1095 Configuration—Next Configuration page The Model 1095 Configuration—Next Configuration page (see figure 46 ) enables you to make configuration changes to the M odel 1095R C and the remote CP E box. When the page displays, t ...

  • Patton electronic 1001MC - page 98

    Configuration and management 98 Model 1001MC Operations Guide 6 • Model 1095RC management Figure 47. W eb page navigation to Model 1095 Configuration—Next Configuration page ...

  • Patton electronic 1001MC - page 99

    Configuration and management 99 Model 1001MC Operations Guide 6 • Model 1095RC management Displaying the Slot Configuration page The Slot Configuration page (see figure 48 ) is used to set slot-specific information related to the system and ho w the system treats that slot in the case of errors or warnings. Figure 48. Slot Configuration page ...

  • Patton electronic 1001MC - page 100

    Configuration and management 100 Model 1001MC Operations Guide 6 • Model 1095RC management Figure 49. W eb page navigation to Slot Configuration page F or more information about items on the Slot Configuration page, see “Slot Configuration page MIB variables description ” on page 110. Displaying the Download page The Download page (see fi ...

  • Patton electronic 1001MC - page 101

    Modem Information page MIB variables description 101 Model 1001MC Operations Guide 6 • Model 1095RC management S tarting from the HOME page, to access the Download page for the 1095RC, click on the Download link. F igure 51 sho ws the web page navigation requir ed to get to this area of the system. Figure 51. W eb page navigation to Download page ...

  • Patton electronic 1001MC - page 102

    Modem Information page MIB variables description 102 Model 1001MC Operations Guide 6 • Model 1095RC management Note Setting the Rack P rotection Mode to normal(0) will enable the rack to receive new configurations through the global configuration command. Submit button After you have defined the number of po wer supplies installed in the rack ...

  • Patton electronic 1001MC - page 103

    Modem Information page MIB variables description 103 Model 1001MC Operations Guide 6 • Model 1095RC management • testM ode(3) W arnings (warningCount) This field displays the warnings that are associated with each modem installed in the system. When warnings are present, this field will be highlighted in y ellow and the number of warnings wil ...

  • Patton electronic 1001MC - page 104

    Model 1095 Configuration Slot page MIB variables description 104 Model 1001MC Operations Guide 6 • Model 1095RC management rack card will then update the M odel 1001MC. For this r eason this information will not be available until after the link is made between the two modems. Protected Y ou can protect individual rack cards from being globally c ...

  • Patton electronic 1001MC - page 105

    Model 1095 Configuration Slot page MIB variables description 105 Model 1001MC Operations Guide 6 • Model 1095RC management Line Status (lineStatus1095) Displays the status of the line. There are thr ee possible values that can be displayed: • startup(1) • dataM ode(2) • testM ode(3) When the line status is dataM ode(2), the units are linked ...

  • Patton electronic 1001MC - page 106

    Model 1095 Configuration Slot page MIB variables description 106 Model 1001MC Operations Guide 6 • Model 1095RC management Input Mode (mode1095) The following settings are av ailable: • onLine(0) • superVisoryMode1) T o make configuration changes to the NetLink-mDSL modems, you must first set this bit to superVisoryMode1). When the Input M ...

  • Patton electronic 1001MC - page 107

    Model 1095 Configuration—Next Configuration page MIB variables description 107 Model 1001MC Operations Guide 6 • Model 1095RC management TM From DTE (dteTM1095/remotedteTM1095) These MIB variables define whether you would like the modems to accept test mode requests fr om the DTE that is connected. In normal applications this should be set to ...

  • Patton electronic 1001MC - page 108

    Model 1095 Configuration—Next Configuration page MIB variables description 108 Model 1001MC Operations Guide 6 • Model 1095RC management The following sections describes the MIB variables that ar e available on the Model 1095 Configuration—Next Configuration page. Card Address (nmsSlotID) Displays the address of the selected N etLink-mDSL m ...

  • Patton electronic 1001MC - page 109

    Model 1095 Configuration—Next Configuration page MIB variables description 109 Model 1001MC Operations Guide 6 • Model 1095RC management Next Configuration table This table shows the configurable MIB variables for the set of units. There are column for the local and remote units. In some cases a single variable applies to both the local and r ...

  • Patton electronic 1001MC - page 110

    Slot Configuration page MIB variables description 110 Model 1001MC Operations Guide 6 • Model 1095RC management T est Mode (testModeSet1095/remotetestModeSet1095) These variables allow y ou to place the N etLink-mDSL rack card into test modes. F or more information on the test modes, please see the N etLink-mDSL T est Modes section belo w . Submi ...

  • Patton electronic 1001MC - page 111

    Using the Download page to upgrade 1095RC software 111 Model 1001MC Operations Guide 6 • Model 1095RC management useful for hardwar e identification. The string can be up to 10 bytes long and can be changed or reset within this page. Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-v olatile flash withi ...

  • Patton electronic 1001MC - page 112

    Using the Download page to upgrade 1095RC software 112 Model 1001MC Operations Guide 6 • Model 1095RC management 4. If you are upgrading M odel 1095R C software, click on the Download 1095RC Software button (see figure 52 ). Otherwise, go to step 8 to download the latest version of the 1095R C Key software. Figure 52. Download 1095RC software bu ...

  • Patton electronic 1001MC - page 113

    Creating and modifying global configuration templates 113 Model 1001MC Operations Guide 6 • Model 1095RC management Creating and modifying global configuration templates M odel 1095R C rack cards can be configur ed globally by templates you cr eate. If you use this capability , you have the option to globally configure some or all M odel 1095R ...

  • Patton electronic 1001MC - page 114

    Creating and modifying global configuration templates 114 Model 1001MC Operations Guide 6 • Model 1095RC management Protecting a Model 1001 rack from global configuration Do the follo wing to protect a M odel 1001 rack: 1. S tarting from the HOME page, click on the Configure Car ds link to display the System Level Infor mation page see figure ...

  • Patton electronic 1001MC - page 115

    Creating and modifying global configuration templates 115 Model 1001MC Operations Guide 6 • Model 1095RC management Figure 55. W eb page navigation to System Level Infor mation page 2. U se the Rack Protection M ode pop-up menu (see figure 54 ) to select protected(1) . Note Setting the Rack P rotection Mode to normal(0) will enable the rack to r ...

  • Patton electronic 1001MC - page 116

    Creating and modifying global configuration templates 116 Model 1001MC Operations Guide 6 • Model 1095RC management Protecting a Model 1095RC rack card from global configuration Do the follo wing to protect a single M odel 1095R C rack card: 1. S tarting from the HOME page, click on the following links: Configure Car ds > View Rack 1 (choose ...

  • Patton electronic 1001MC - page 117

    Creating and modifying global configuration templates 117 Model 1001MC Operations Guide 6 • Model 1095RC management 2. Locate the card addr ess (see figure 56 on page 116) of the M odel 1095R C you want to protect. 3. Set the P rotected pop-up menu (see figure 56 on page 116) to protected(1) . Note Setting the P rotected option to normal(0) wil ...

  • Patton electronic 1001MC - page 118

    Creating and modifying global configuration templates 118 Model 1001MC Operations Guide 6 • Model 1095RC management Notes on clock mode settings The Clock M ode Setting determines the source of timing for the link. M ost applications will use one of the following configurations: • internal-receiveR ecover(0) • external-receiveR ecover(1) The ...

  • Patton electronic 1001MC - page 119

    Creating and modifying global configuration templates 119 Model 1001MC Operations Guide 6 • Model 1095RC management Procedure for creating a template Figure 58. Global Configuration Menu page Note Y ou can create as many as five templates, if you need to delete a tem- plate to make room for another , refer to section “” on page 125). Do the ...

  • Patton electronic 1001MC - page 120

    Creating and modifying global configuration templates 120 Model 1001MC Operations Guide 6 • Model 1095RC management 2. U se the Local DTE Rate pop-up menu to select local DTE rate. Y ou have the following choices: 3. U se the Local Clock Mode (Local-R emote) pop-up menu to select the clock mode. Y ou have the following choices: – internal-recei ...

  • Patton electronic 1001MC - page 121

    Creating and modifying global configuration templates 121 Model 1001MC Operations Guide 6 • Model 1095RC management – normal(3) 9. Configure the Remote F raming M ode pop-up menu using the following choices: – slotted(0) – normal(3) 10. When you have finished setting the configuration, click on the Submit button to save the changes. Note ...

  • Patton electronic 1001MC - page 122

    Creating and modifying global configuration templates 122 Model 1001MC Operations Guide 6 • Model 1095RC management the unit, so it is not necessary to have a G.703/G.704 link available. When using any other type of serial inter- face, make sure that an external clock is pro vided by the DTE equipment or the modems will not link. Notes on clock m ...

  • Patton electronic 1001MC - page 123

    Creating and modifying global configuration templates 123 Model 1001MC Operations Guide 6 • Model 1095RC management Procedure for modifying a template Figure 60. Global Configuration Menu page Do the follo wing to modify a template: 1. Select a template from the Modify Configuration pop-up menu (see figure 58 ), then click the Modify Con- fi ...

  • Patton electronic 1001MC - page 124

    Creating and modifying global configuration templates 124 Model 1001MC Operations Guide 6 • Model 1095RC management 2. U se the Local DTE Rate pop-up menu to select local DTE rate. Y ou have the following choices: 3. U se the Local Clock Mode (Local-R emote) pop-up menu to select the clock mode. Y ou have the following choices: – internal-recei ...

  • Patton electronic 1001MC - page 125

    Creating and modifying global configuration templates 125 Model 1001MC Operations Guide 6 • Model 1095RC management – normal(3) 9. Configure the Remote F raming M ode pop-up menu using the following choices: – slotted(0) – normal(3) 10. When you have finished setting the configuration, click on the Submit button to save the changes. Note ...

  • Patton electronic 1001MC - page 126

    Creating and modifying global configuration templates 126 Model 1001MC Operations Guide 6 • Model 1095RC management • M odel 1095R C rack cards that hav e had the Protected option set to protected(1) will not be configured if a global template is applied (see section “P rotecting a M odel 1095R C rack card from global configuration ” on p ...

  • Patton electronic 1001MC - page 127

    Creating and modifying global configuration templates 127 Model 1001MC Operations Guide 6 • Model 1095RC management Figure 64. W eb page navigation to System Level Infor mation page 2. U se the Apply S ystem Configur ation pop-up menu (see figure 63 ) to select the template you want to apply . 3. Click the Apply Con fi guration button. The tem ...

  • Patton electronic 1001MC - page 128

    Creating and modifying global configuration templates 128 Model 1001MC Operations Guide 6 • Model 1095RC management Configure all Model 1095RC rack cards in one Model 1001 rack Do the follo wing to apply global configuration to all Model 1095R C rack cards installed in one M odel 1001 rack: 1. S tarting from the HOME page, click on the Configu ...

  • Patton electronic 1001MC - page 129

    129 Chapter 7 Model 2701RC management Chapter contents Introduction ........................................................................................................................................................132 NetLink-NMS description ...................................................................................................... ...

  • Patton electronic 1001MC - page 130

    130 Model 1001MC Operations Guide 7 • Model 2701RC management Input Mode (mode2701RC) .........................................................................................................................146 Model 2701 Configuration Slot page Configuration Status table description ................................................146 Configurati ...

  • Patton electronic 1001MC - page 131

    131 Model 1001MC Operations Guide 7 • Model 2701RC management Config Type (configType) ............................................................................................................................153 Test Mode from DTE (testModeDTE) .................................................................................................... ...

  • Patton electronic 1001MC - page 132

    Introduction 132 Model 1001MC Operations Guide 7 • Model 2701RC management Introduction This chapter describes managing a M odel 2701R C N etLink-G.703/G.704 network termination unit (NTU) using the M odel 1001MC N etLink-NMS internal HTTP/HTML web engine and a standard web bro wser . This chapter is meant to be used in addition to the manual tha ...

  • Patton electronic 1001MC - page 133

    Configuration and management 133 Model 1001MC Operations Guide 7 • Model 2701RC management Displaying the Modem Information page The Modem Information page (see figure 66 ) displays the car ds installed in the system and a quick view of any errors or warnings associated with your modems. Figure 66. Modem Information page for the Model 2701RC S t ...

  • Patton electronic 1001MC - page 134

    Configuration and management 134 Model 1001MC Operations Guide 7 • Model 2701RC management Figure 67. W eb page navigation to Modem Infor mation page ...

  • Patton electronic 1001MC - page 135

    Configuration and management 135 Model 1001MC Operations Guide 7 • Model 2701RC management Displaying the Model 2701RC Configuration Slot page The Model 2701RC Configuration Slot page (see figure 68 ) enables you to make configuration changes to the M odel 2701R C and the remote NTU. When the page displays, the unit is set to the onLine state ...

  • Patton electronic 1001MC - page 136

    Configuration and management 136 Model 1001MC Operations Guide 7 • Model 2701RC management Figure 69. W eb page navigation to Model 2701RC Configuration Slot page Making configuration changes to your 2701RC NetLink NTU Do use the follo wing to make configuration changes to your N etLink NTU. Note Y ou must be logged in as super user to perform ...

  • Patton electronic 1001MC - page 137

    Configuration and management 137 Model 1001MC Operations Guide 7 • Model 2701RC management Displaying the Model 2701 Configuration page The Model 2701 Configuration page (see figure 70 ) enables you to make configuration changes to the M odel 2701R C and the remote CPE box. Figure 70. Model 2701 Configuration page S tarting from the HOME pag ...

  • Patton electronic 1001MC - page 138

    Configuration and management 138 Model 1001MC Operations Guide 7 • Model 2701RC management Figure 71. W eb page navigation to Model 2701 Configuration page ...

  • Patton electronic 1001MC - page 139

    Configuration and management 139 Model 1001MC Operations Guide 7 • Model 2701RC management Displaying the Slot Configuration Page The Slot Configuration Page (see figure 72 ) is used to set slot-specific information related to the system and how the system treats that slot in the case of err ors or warnings. Figure 72. Slot Configuration Pag ...

  • Patton electronic 1001MC - page 140

    Modem Information Rack X page MIB variables description 140 Model 1001MC Operations Guide 7 • Model 2701RC management Figure 73. W eb page navigation to Slot Configuration Page F or more information about items on the Slot Configuration page, see “Slot Configuration page MIB variables description ” on page 153. Modem Information Rack X pag ...

  • Patton electronic 1001MC - page 141

    Modem Information Rack X page MIB variables description 141 Model 1001MC Operations Guide 7 • Model 2701RC management Note Setting the Rack P rotection Mode to normal(0) will enable the rack to receive new configurations through the global configuration command. Submit button After you have defined the number of po wer supplies installed in th ...

  • Patton electronic 1001MC - page 142

    Modem Information Rack X page MIB variables description 142 Model 1001MC Operations Guide 7 • Model 2701RC management • testM ode(3) W arnings (warningCount) This field displays the warnings that are associated with each modem installed in the system. When warnings are present, this field will be highlighted in y ellow and the number of warni ...

  • Patton electronic 1001MC - page 143

    Model 2701RC Configuration Slot X page MIB variables description 143 Model 1001MC Operations Guide 7 • Model 2701RC management Protected (disableGlobalConfig) Y ou can protect individual rack cards from being globally configured by setting the pop-up menu fr om nor- mal(0) to protected(1) . After you have set the protection option, if you ar e ...

  • Patton electronic 1001MC - page 144

    Model 2701RC Configuration Slot X page MIB variables description 144 Model 1001MC Operations Guide 7 • Model 2701RC management Line Status (lineStatus) Displays the status of the line. There are thr ee possible values that can be displayed: • linedown(1) • dataM ode(2)—When the line status is dataMode(2), the units ar e linked-up and ready ...

  • Patton electronic 1001MC - page 145

    Model 2701RC Configuration Slot X page MIB variables description 145 Model 1001MC Operations Guide 7 • Model 2701RC management AIS (aisAlarm) Displays the number of times an Alarm I ndication Signal on the E1 line is detected. This should be set when an unframed all ones code is received at RPOSI and RNEGI. This number is accumulating in the 1001 ...

  • Patton electronic 1001MC - page 146

    Model 2701RC Configuration Slot X page MIB variables description 146 Model 1001MC Operations Guide 7 • Model 2701RC management CRC4 Error Alarm Threshold (crc4Threshold) The valid setting for the threshold is 0 to 255. B y setting a threshold, the CR C4 Alarm counter will not issue the error/warning, Syslog, and SNMP T rap message unless the accu ...

  • Patton electronic 1001MC - page 147

    Model 2701RC Configuration Slot X page MIB variables description 147 Model 1001MC Operations Guide 7 • Model 2701RC management Line Format (lineFormat) The following status variables can be display ed: • unframe-G703(0)—Sets the line format to G.703 unframed • frame-G704(1)—Sets the line format to framed G.704 Clock Mode (clockMode2701RC) ...

  • Patton electronic 1001MC - page 148

    Model 2701RC Configuration Slot X page MIB variables description 148 Model 1001MC Operations Guide 7 • Model 2701RC management • lal(4) • lalWithpat(5) • lalWithpate(6) • rdl-v54(7) • rdl-v54W ithpat(8) • rdl-v54W ithpate(9) • rdl-csu(10) • rdl-csuW ithpat(11) • rdl-csuW ithpate(12) • rdl-r emote(13) SW T est Mode (testModeSet ...

  • Patton electronic 1001MC - page 149

    Model 2701 Configuration page MIB variables description 149 Model 1001MC Operations Guide 7 • Model 2701RC management period, the unit will automatically time out and return to normal data mode. The timeout does not apply for loops selected via the front panel switches. RDL type (rdlT ype) This displays the selected remote loopback type that will ...

  • Patton electronic 1001MC - page 150

    Model 2701 Configuration page MIB variables description 150 Model 1001MC Operations Guide 7 • Model 2701RC management Configuration T ype (configT ype) This displays if the 2701R C is using the DIP switch control or software control for its configuration. Channel Assignment (dsoEnableCh1…dsoEnableCh31) If the 2701R C is operating in G.704 ch ...

  • Patton electronic 1001MC - page 151

    Model 2701 Configuration page MIB variables description 151 Model 1001MC Operations Guide 7 • Model 2701RC management CRC4 Framing (crc) This variable is used to enable or disable CR C-4 framing. The following options ar e available: • disable(0) • enable(1) Note This setting should be the same as the G.703/G.704 network. CAS Multiframing (ca ...

  • Patton electronic 1001MC - page 152

    Model 2701 Configuration page MIB variables description 152 Model 1001MC Operations Guide 7 • Model 2701RC management • rdl-csuW ithpate(12) • rdl-r emote(13) Software T est Mode (testModeSet2701RC) This is used to invoke test modes through the NMS. A vailable options are: • off(1)-N o test mode in process • pat(2)—P attern generator (5 ...

  • Patton electronic 1001MC - page 153

    Slot Configuration page MIB variables description 153 Model 1001MC Operations Guide 7 • Model 2701RC management RDL T ype (rdlT ype) This displays the selected remote loopback type that will be used when initiating a remote loopback. A vailable options are: • csu(1) • v54(2) Config T ype (configT ype) The following options are av ailable: ? ...

  • Patton electronic 1001MC - page 154

    Slot Configuration page MIB variables description 154 Model 1001MC Operations Guide 7 • Model 2701RC management Remote User Id (remoteUserID) U ser supplied string that defines the Customer P remise box at the far end of the link. The string is stored in non- volatile flash within the CP unit. If the unit is mo ved, the U ser ID will move to th ...

  • Patton electronic 1001MC - page 155

    Creating and modifying global configuration templates 155 Model 1001MC Operations Guide 7 • Model 2701RC management Creating and modifying global configuration templates M odel 2701R C rack cards can be configur ed globally by templates you cr eate. If you use this capability , you have the option to globally configure some or all M odel 2701R ...

  • Patton electronic 1001MC - page 156

    Creating and modifying global configuration templates 156 Model 1001MC Operations Guide 7 • Model 2701RC management 1. S tarting from the HOME page, click on the Configure Cards link to display the System Level Information page see figure 74 . Figure 74. System Level Information page 2. U se the Rack Protection Mode pop-up menu (see figure 74 ...

  • Patton electronic 1001MC - page 157

    Creating and modifying global configuration templates 157 Model 1001MC Operations Guide 7 • Model 2701RC management 3. Click the Apply Pr otection button. The rack is now protected. Protecting a selected Model 2701RC rack card fr om global configuration Do the follo wing to protect a single M odel 2701R C rack card: 1. S tarting from the HOME pa ...

  • Patton electronic 1001MC - page 158

    Creating and modifying global configuration templates 158 Model 1001MC Operations Guide 7 • Model 2701RC management Creating a template This section describes how to create a global configuration template. Figure 76. Global Configuration Menu page Note Y ou can create as many as five templates, if you need to delete a tem- plate to make room f ...

  • Patton electronic 1001MC - page 159

    Creating and modifying global configuration templates 159 Model 1001MC Operations Guide 7 • Model 2701RC management The first table is the Channel Assignment section for activating the DS0 time slots you need (see figure 77 ). The two options for each channel are: – Active(0) – Inactive(1) Figure 77. Channel Assignment table ...

  • Patton electronic 1001MC - page 160

    Creating and modifying global configuration templates 160 Model 1001MC Operations Guide 7 • Model 2701RC management The second part is the Unit Configuration section (see figure 78 ) for the configuration of the E1 link parame- ters. There are 16 configurable parameters. What follo ws is a description of them with the available options for ea ...

  • Patton electronic 1001MC - page 161

    Creating and modifying global configuration templates 161 Model 1001MC Operations Guide 7 • Model 2701RC management - qrss(0)—Quasi-random-signal-source - five11(1)—The 511-bit length pseudo-random test pattern - two047(2)—The 2047-bit length pseudo-random test pattern • Loop T imeout, determines the length of the in-band loop test. If t ...

  • Patton electronic 1001MC - page 162

    Creating and modifying global configuration templates 162 Model 1001MC Operations Guide 7 • Model 2701RC management • Tx Clock T iming, this selects the source of the DTE T ransmit Clock signal. Note that Clock M ode above is for the transmitted E1 signal. - external(0)—U se only when the Clock M ode is set to external-CLK(2). - internal(1)? ...

  • Patton electronic 1001MC - page 163

    Creating and modifying global configuration templates 163 Model 1001MC Operations Guide 7 • Model 2701RC management Modifying a template This section describes how to modify a global configuration template. Figure 79. Global Configuration Menu page Do the follo wing to modify a template: 1. Select a template from the Modify Configuration pop-u ...

  • Patton electronic 1001MC - page 164

    Creating and modifying global configuration templates 164 Model 1001MC Operations Guide 7 • Model 2701RC management Figure 80. Model 2701RC Global Configuration page 2. Change the parameters requiring modification (see figure 80 ). When you have finished changing the con- figuration, click on the Submit button to save the changes. Refer to s ...

  • Patton electronic 1001MC - page 165

    Creating and modifying global configuration templates 165 Model 1001MC Operations Guide 7 • Model 2701RC management The template can be applied to: • All 2701R C NTUs in ALL M odel 1001 racks • All 2701R C NTUs in just ONE M odel 1001 rack T o configure all Model 2701RC rack cards in all Model 1001 racks Complete the following steps. 1. S ta ...

  • Patton electronic 1001MC - page 166

    Creating and modifying global configuration templates 166 Model 1001MC Operations Guide 7 • Model 2701RC management T o configure all Model 2701RC rack cards in just one Model 1001 rack Complete the following steps: 1. S tarting from the HOME page, click on the Configure Cards link to display the S ystem Level Information page see figure 82 . ...

  • Patton electronic 1001MC - page 167

    167 Chapter 8 Model 2707RC management Chapter contents Introduction ........................................................................................................................................................169 NetLink-NMS description ...................................................................................................... ...

  • Patton electronic 1001MC - page 168

    168 Model 1001MC Operations Guide 8 • Model 2707RC management Line Coding (lineCoding2707RC) ..........................................................................................................182 Line Build Out (lineBuildOut) ...............................................................................................................182 ...

  • Patton electronic 1001MC - page 169

    Introduction 169 Model 1001MC Operations Guide 8 • Model 2707RC management Introduction This chapter describes managing a M odel 2707R C N etLink-G.703 network termination unit (NTU) using the M odel 1001MC N etLink-NMS internal HTTP/HTML web engine and a standard web bro wser . This chapter is meant to be used in addition to the manual that came ...

  • Patton electronic 1001MC - page 170

    Configuration and management 170 Model 1001MC Operations Guide 8 • Model 2707RC management Displaying the Modem Information page The Modem Information page (see figure 83 ) displays the car ds installed in the system and a quick view of any errors or warnings associated with your modems. Figure 83. Modem Information page for the Model 2707RC S t ...

  • Patton electronic 1001MC - page 171

    Configuration and management 171 Model 1001MC Operations Guide 8 • Model 2707RC management Figure 84. W eb page navigation to Modem Infor mation page ...

  • Patton electronic 1001MC - page 172

    Configuration and management 172 Model 1001MC Operations Guide 8 • Model 2707RC management Displaying the Model 2707RC Configuration Slot page The Model 2707RC Configuration Slot page (see figure 85 ) enables you to make configuration changes to the M odel 2707R C and the remote NTU. When the page displays, the unit is set to the onLine state ...

  • Patton electronic 1001MC - page 173

    Configuration and management 173 Model 1001MC Operations Guide 8 • Model 2707RC management Figure 86. W eb page navigation to Model 2707RC Configuration Slot page Making configuration changes to your 2707RC NetLink NTU Do use the follo wing to make configuration changes to your N etLink NTU. Note Y ou must be logged in as super user to perform ...

  • Patton electronic 1001MC - page 174

    Configuration and management 174 Model 1001MC Operations Guide 8 • Model 2707RC management Displaying the Model 2707RC Configuration—Configuration page The Model 2707RC Configuration—Configuration page (see figure 87 ) enables you to make configuration changes to the M odel 2707R C and the remote CP E box. When the page displays, the un ...

  • Patton electronic 1001MC - page 175

    Configuration and management 175 Model 1001MC Operations Guide 8 • Model 2707RC management Figure 88. W eb page navigation to Model 2707RC Configuration—Next Configuration page ...

  • Patton electronic 1001MC - page 176

    Configuration and management 176 Model 1001MC Operations Guide 8 • Model 2707RC management Displaying the Slot Configuration page The Slot Configuration page (see figure 89 ) is used to set slot-specific information related to the system and ho w the system treats that slot in the case of errors or warnings. Figure 89. Slot Configuration pag ...

  • Patton electronic 1001MC - page 177

    Modem Information page MIB variables description 177 Model 1001MC Operations Guide 8 • Model 2707RC management Figure 90. W eb page navigation to Slot Configuration page F or more information about items on the Slot Configuration page, see “Slot Configuration page MIB variables description ” on page 185. Modem Information page MIB variable ...

  • Patton electronic 1001MC - page 178

    Modem Information page MIB variables description 178 Model 1001MC Operations Guide 8 • Model 2707RC management Submit button After you have defined the number of po wer supplies installed in the rack and the rack protection mode, click on the Submit button to save the changes. Power Supply 1 Status Displays the current status of po wer supply 1 ...

  • Patton electronic 1001MC - page 179

    Modem Information page MIB variables description 179 Model 1001MC Operations Guide 8 • Model 2707RC management W arnings (warningCount) This field displays the warnings that are associated with each modem installed in the system. When warnings are present, this field will be highlighted in y ellow and the number of warnings will be listed. F or ...

  • Patton electronic 1001MC - page 180

    Modem Information page MIB variables description 180 Model 1001MC Operations Guide 8 • Model 2707RC management rack card will then update the M odel 1001MC. For this r eason this information will not be available until after the link is made between the two modems. Note This feature is not supported by M odel 270XR C network termina- tion units ( ...

  • Patton electronic 1001MC - page 181

    Model 2707RC Configuration Slot page MIB variables description 181 Model 1001MC Operations Guide 8 • Model 2707RC management Model 2707RC Configuration Slot page MIB variables description This section describes the MIB variables that are available on the Model 2707RC Configuration Slot page. Model 2707RC Configuration Slot (nmsSlotID) Displays ...

  • Patton electronic 1001MC - page 182

    Model 2707RC Configuration Slot page MIB variables description 182 Model 1001MC Operations Guide 8 • Model 2707RC management Configuration Status (configStatus2707RC) Displays the configuration status of the rack car d. The following status can be displayed: • N egotiating(0)—The 1001MC is receiving the rack car d’ s configuration for t ...

  • Patton electronic 1001MC - page 183

    Model 2707RC Configuration—Configuration page MIB variables description 183 Model 1001MC Operations Guide 8 • Model 2707RC management Loop T ime Out (loopT o) This displays the amount of time that the unit responding to a Remote Loop command will r emain in test mode when the RL test mode is invoked. If the unit is not taken out of test mode by ...

  • Patton electronic 1001MC - page 184

    Model 2707RC Configuration—Configuration page MIB variables description 184 Model 1001MC Operations Guide 8 • Model 2707RC management Unit Configuration table This table shows the configurable MIB variables for the 2707R C card. After changes are made, select the Sub- mit Query button at the bottom of the table and then place the Input M ode ...

  • Patton electronic 1001MC - page 185

    Slot Configuration page MIB variables description 185 Model 1001MC Operations Guide 8 • Model 2707RC management Loop Timeout (loopT o) This selects the amount of time that the unit will remain in test mode when the remote test mode is inv oked. If the responding unit is not taken out of test mode within this time period, the unit will automatical ...

  • Patton electronic 1001MC - page 186

    Slot Configuration page MIB variables description 186 Model 1001MC Operations Guide 8 • Model 2707RC management Remote User Id (remoteUserID) This feature is not supported by the M odel 2707R C NTU. Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-v olatile flash within the M odel 1001MC. Remote Circuit ...

  • Patton electronic 1001MC - page 187

    187 Chapter 9 Model 3088RC management Chapter contents Introduction ........................................................................................................................................................190 NetLink-NMS description ...................................................................................................... ...

  • Patton electronic 1001MC - page 188

    188 Model 1001MC Operations Guide 9 • Model 3088RC management Input Mode (mode3088RC) .........................................................................................................................204 Model 3088RC Configuration Slot page Configuration Status table description ..........................................204 Configuration S ...

  • Patton electronic 1001MC - page 189

    189 Model 1001MC Operations Guide 9 • Model 3088RC management Card Lost Indication (cardLostIndication) ..............................................................................................210 Line Down Indication (lineDownIndication) ..........................................................................................210 Creating a ...

  • Patton electronic 1001MC - page 190

    Introduction 190 Model 1001MC Operations Guide 9 • Model 3088RC management Introduction This chapter describes managing a M odel 3088R C N etLink-G.SHDSL network termination unit (NTU) using the M odel 1001MC N etLink-NMS internal HTTP/HTML web engine and a standard web bro wser . This chapter is meant to be used in addition to the manual that ca ...

  • Patton electronic 1001MC - page 191

    Configuration and management 191 Model 1001MC Operations Guide 9 • Model 3088RC management Displaying the Modem Information page The Modem Information page (see figure 91 ) displays the car ds installed in the system and a quick view of any errors or warnings associated with your modems. Figure 91. Modem Information page for the Model 3088RC S t ...

  • Patton electronic 1001MC - page 192

    Configuration and management 192 Model 1001MC Operations Guide 9 • Model 3088RC management Figure 92. W eb page navigation to Modem Infor mation page ...

  • Patton electronic 1001MC - page 193

    Configuration and management 193 Model 1001MC Operations Guide 9 • Model 3088RC management Displaying the Model 3088RC Configuration Slot page The Model 3088RC Configuration Slot page (see figure 93 ) enables you to make configuration changes to the M odel 3088R C and the remote NTU. When the page displays, the unit is set to the onLine state ...

  • Patton electronic 1001MC - page 194

    Configuration and management 194 Model 1001MC Operations Guide 9 • Model 3088RC management Figure 94. W eb page navigation to Model 3088RC Configuration Slot page Making configuration changes to your 3088RC NetLink NTU Do use the follo wing to make configuration changes to your N etLink NTU. Note Y ou must be logged in as super user to perform ...

  • Patton electronic 1001MC - page 195

    Configuration and management 195 Model 1001MC Operations Guide 9 • Model 3088RC management Displaying the Model 3088RC Configuration page The Model 3088RC Configuration page (see figure 95 ) enables you to make configuration changes to the M odel 3088R C and the remote CP E box. Figure 95. Model 3088RC Configuration page S tarting from the H ...

  • Patton electronic 1001MC - page 196

    Configuration and management 196 Model 1001MC Operations Guide 9 • Model 3088RC management Figure 96. W eb page navigation to Model 3088RC Configuration page ...

  • Patton electronic 1001MC - page 197

    Configuration and management 197 Model 1001MC Operations Guide 9 • Model 3088RC management Displaying the Slot Configuration Page The Slot Configuration Page (see figure 97 ) is used to set slot-specific information related to the system and how the system treats that slot in the case of err ors or warnings. Figure 97. Slot Configuration Pag ...

  • Patton electronic 1001MC - page 198

    Modem Information Rack X page MIB variables description 198 Model 1001MC Operations Guide 9 • Model 3088RC management Figure 98. W eb page navigation to Slot Configuration Page F or more information about items on the Slot Configuration page, see “Slot Configuration page MIB variables description ” on page 209. Modem Information Rack X pag ...

  • Patton electronic 1001MC - page 199

    Modem Information Rack X page MIB variables description 199 Model 1001MC Operations Guide 9 • Model 3088RC management Note Setting the Rack P rotection Mode to normal(0) will enable the rack to receive new configurations through the global configuration command. Submit button After you have defined the number of po wer supplies installed in th ...

  • Patton electronic 1001MC - page 200

    Modem Information Rack X page MIB variables description 200 Model 1001MC Operations Guide 9 • Model 3088RC management • testM ode(3) W arnings (warningCount) This field displays the warnings that are associated with each modem installed in the system. When warnings are present, this field will be highlighted in y ellow and the number of warni ...

  • Patton electronic 1001MC - page 201

    Model 3088RC Configuration Slot X page MIB variables description 201 Model 1001MC Operations Guide 9 • Model 3088RC management Protected (disableGlobalConfig) Y ou can protect individual rack cards from being globally configured by setting the pop-up menu fr om nor- mal(0) to protected(1) . After you have set the protection option, if you ar e ...

  • Patton electronic 1001MC - page 202

    Model 3088RC Configuration Slot X page MIB variables description 202 Model 1001MC Operations Guide 9 • Model 3088RC management Line Status (lineStatus) Displays the status of the line. There are thr ee possible values that can be displayed: • linedown(1) • dataM ode(2)—When the line status is dataMode(2), the units ar e linked-up and ready ...

  • Patton electronic 1001MC - page 203

    Model 3088RC Configuration Slot X page MIB variables description 203 Model 1001MC Operations Guide 9 • Model 3088RC management AIS (aisAlarm) Displays the number of times an Alarm I ndication Signal on the E1 line is detected. This should be set when an unframed all ones code is received at RPOSI and RNEGI. This number is accumulating in the 1001 ...

  • Patton electronic 1001MC - page 204

    Model 3088RC Configuration Slot X page MIB variables description 204 Model 1001MC Operations Guide 9 • Model 3088RC management CRC4 Error Alarm Threshold (crc4Threshold) The valid setting for the threshold is 0 to 255. B y setting a threshold, the CR C4 Alarm counter will not issue the error/warning, Syslog, and SNMP T rap message unless the accu ...

  • Patton electronic 1001MC - page 205

    Model 3088RC Configuration Slot X page MIB variables description 205 Model 1001MC Operations Guide 9 • Model 3088RC management DTE Rate (dteRate3088RC) This variable displays the DTE rate for the link. This is the Nx64 kbps data rate selected by the number of acti- vated channels. Clock Mode (clockMode3088RC) This variable defines the clock mode ...

  • Patton electronic 1001MC - page 206

    Model 3088RC Configuration page MIB variables description 206 Model 1001MC Operations Guide 9 • Model 3088RC management Response to T est Mode (responseT oT estMode3088RC) This variable allows or disallo ws test modes to be initiated front both the front panel or from the r emote unit. • enable(0) • disable(1) Software V ersion (softV ersion3 ...

  • Patton electronic 1001MC - page 207

    Model 3088RC Configuration page MIB variables description 207 Model 1001MC Operations Guide 9 • Model 3088RC management Configuration T ype (configT ype) This displays if the 3088R C is using the DIP switch control or software control for its configuration. Unit Configuration table This table shows the configurable MIB variables for the set ...

  • Patton electronic 1001MC - page 208

    Model 3088RC Configuration page MIB variables description 208 Model 1001MC Operations Guide 9 • Model 3088RC management Tx Clock Timing (txClock) The following options are av ailable: • external(0)—serial transmit data coming from the DTE is clocked in using the DTE pro vided external clock • internal(1)—serial transmit data coming from t ...

  • Patton electronic 1001MC - page 209

    Slot Configuration page MIB variables description 209 Model 1001MC Operations Guide 9 • Model 3088RC management Software T est Mode (testModeSet3088RC) This is used to invoke test modes through the NMS. A vailable options are: • lal(4)—Local loopback test • rdl(7)—R emote loopback test from V54 RDL Response(v54Loop) The following options ...

  • Patton electronic 1001MC - page 210

    Slot Configuration page MIB variables description 210 Model 1001MC Operations Guide 9 • Model 3088RC management Remote User Id (remoteUserID) U ser supplied string that defines the Customer P remise box at the far end of the link. The string is stored in non- volatile flash within the CP unit. If the unit is mo ved, the U ser ID will move to th ...

  • Patton electronic 1001MC - page 211

    Creating and modifying global configuration templates 211 Model 1001MC Operations Guide 9 • Model 3088RC management Creating and modifying global configuration templates M odel 3088R C rack cards can be configur ed globally by templates you cr eate. If you use this capability , you have the option to globally configure some or all M odel 3088R ...

  • Patton electronic 1001MC - page 212

    Creating and modifying global configuration templates 212 Model 1001MC Operations Guide 9 • Model 3088RC management 1. S tarting from the HOME page, click on the Configure Cards link to display the System Level Information page see figure 99 . Figure 99. System Level Information page 2. U se the Rack Protection Mode pop-up menu (see figure 99 ...

  • Patton electronic 1001MC - page 213

    Creating and modifying global configuration templates 213 Model 1001MC Operations Guide 9 • Model 3088RC management 3. Click the Apply Pr otection button. The rack is now protected. Protecting a selected Model 3088RC rack card fr om global configuration Do the follo wing to protect a single M odel 3088R C rack card: 1. S tarting from the HOME pa ...

  • Patton electronic 1001MC - page 214

    Creating and modifying global configuration templates 214 Model 1001MC Operations Guide 9 • Model 3088RC management Creating a template This section describes how to create a global configuration template. Figure 100. Global Configuration Menu page Note Y ou can create as many as five templates, if you need to delete a tem- plate to make room ...

  • Patton electronic 1001MC - page 215

    Creating and modifying global configuration templates 215 Model 1001MC Operations Guide 9 • Model 3088RC management F igure 101 is the Unit Configuration section (see figure 101 ) for the configuring E1 link parameters. There are 16 configurable parameters. What follo ws is a description of them with the available options for each. Figure 101 ...

  • Patton electronic 1001MC - page 216

    Creating and modifying global configuration templates 216 Model 1001MC Operations Guide 9 • Model 3088RC management • SW T est M ode (testM odeSet3088R C) This displays any test mode invoked through the NMS. S ee next configuration for information about invoking test modes through the NMS. This option will be highlighted in blue if the unit is ...

  • Patton electronic 1001MC - page 217

    Creating and modifying global configuration templates 217 Model 1001MC Operations Guide 9 • Model 3088RC management 1. Select a template from the Modify Configuration pop-up menu (see figure 102 ), then click the Modify Configuration button. 2. Change the parameters requiring modification (see figure 103 ). When you have finished changing t ...

  • Patton electronic 1001MC - page 218

    Creating and modifying global configuration templates 218 Model 1001MC Operations Guide 9 • Model 3088RC management Figure 103. System Level Information page—System Over view section 2. U se the Apply 3088RC System Configuration pop-up menu (see figure 103 ) to select the template you want to apply . 3. Click the Apply Configuration button. ...

  • Patton electronic 1001MC - page 219

    Creating and modifying global configuration templates 219 Model 1001MC Operations Guide 9 • Model 3088RC management T o configure all Model 3088RC rack cards in just one Model 1001 rack Complete the following steps: 1. S tarting from the HOME page, click on the Configure Cards link to display the S ystem Level Information page see figure 104 . ...

  • Patton electronic 1001MC - page 220

    220 Chapter 10 HTTP/HTML web page reference Chapter contents Introduction ........................................................................................................................................................224 Login .................................................................................................................. ...

  • Patton electronic 1001MC - page 221

    221 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Total Slots Available (totalConfigSlots) ...................................................................................................236 Total Cards Installed (totalActiveSlots) ............................................................................................... ...

  • Patton electronic 1001MC - page 222

    222 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Card Identification Information ....................................................................................................................243 Local User Id (localUserID) .................................................................................................... ...

  • Patton electronic 1001MC - page 223

    223 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Unix Facility ...........................................................................................................................................255 Maintenance ............................................................................................................... ...

  • Patton electronic 1001MC - page 224

    Introduction 224 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Introduction This section describes how to navigate the internal HTTP/HTML web pages on the M odel 1001MC. The diagram below sho ws how all of the web pages ar e linked together . F ollowing figure 105 , there is a brief description of each page. Figure 105. 1001MC ...

  • Patton electronic 1001MC - page 225

    Introduction 225 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference • monitor —The monitor level password enables you to view statistics, but it will not let you make any config- uration changes. T o log into the system at the monitor level, type monitor , all lower case, for the username and password. Note The superuser and mon ...

  • Patton electronic 1001MC - page 226

    Introduction 226 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference The Hard Reset button forces the 1001MC to perform a reset. This will not reset the individual cards in the rack only the 1001MC. If you would like to perform a hardwar e reset on the individual car ds, refer to the Slot Configuration page. See section “HOME” on ...

  • Patton electronic 1001MC - page 227

    Introduction 227 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference F rom this page, you can select a View Rack hyperlink that will display the Modem Information Page for the selected rack. Modem Information Page The Modem Information Page consists of a table that displays top level information about the cards installed in the select ...

  • Patton electronic 1001MC - page 228

    HOME 228 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Syslog—Modify The Syslog—Modify web page allows y ou to setup the configuration for the Syslog messaging system. Y ou can set variables such as the IP address of a S yslog Daemon and priority levels for each of the messaging facilities (see section “System Log—M odi ...

  • Patton electronic 1001MC - page 229

    HOME 229 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Box Name (boxName) This variable displays a user defined string that repr esents the name of the box. This variable can be changed by the user in the System I nfo web page. Box Contact (boxContact) This variable displays a user defined string that repr esents the contact f ...

  • Patton electronic 1001MC - page 230

    HOME 230 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference through the Configure Car ds web page for the system, or the Slot Configuration page for the individual modems. Y ou can view the System Log page to examine the source of the warnings. Figure 111. Immediate actions Immediate Actions There are sev eral immediate actions whi ...

  • Patton electronic 1001MC - page 231

    About 1001MC 231 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Figure 112. About 1001MC About 1001MC The About 1001MC link displays system information and the following P atton Electronics Company contact information: P atton Electronics Co. 7622 Rickenbacker Drive Gaithersburg, Maryland 20879, U.S.A. Phone: +1 (301) 975-1000 F ...

  • Patton electronic 1001MC - page 232

    About 1001MC 232 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Figure 113. System Level Information page ...

  • Patton electronic 1001MC - page 233

    Import Export 233 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Import Expor t The Import/Export function enables you to make a backup (or expor t ) copy of your M odel 1001MC’ s configura- tion parameters. By exporting the configurations, the saved files can quickly be loaded, or imported , into a replace- ment M odel 1001 ...

  • Patton electronic 1001MC - page 234

    Import Export 234 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference T o expor t the flash configuration, click on the Export Flash link on the Impor t/Expor t main page. The Model 1001MC will display text configuration information resembling that shown in figure 115 . Figure 115. T ypical access ser ver flash memor y configura ...

  • Patton electronic 1001MC - page 235

    System Level Information 235 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Import Configuration T o impor t a configuration file into the access server , type the complete path and filename for the configuration file you wish to load or click on the Browse… button to select the desired file, then click on the Submit Que ...

  • Patton electronic 1001MC - page 236

    System Level Information 236 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Apply System T est Mode If you are going to be running in system test mode, select one of the follo wing test patterns from the pop-up menu, then click the Apply T est Mode button. Note The M odel 2707R C operates only in the local loopback lal(4) mode. ? ...

  • Patton electronic 1001MC - page 237

    System Level Information 237 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Rack X Enable (rackXEnable) This is where you can enable or disable a rack for use by the system. Y ou will almost always want to have the rack enabled, but it can be useful to disable a rack if: • Y our system configuration has fe wer rack cards than ...

  • Patton electronic 1001MC - page 238

    System Level Information 238 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Apply T est Mode If you are going to be running in test mode, select one of the follo wing test patterns from the pop-up menu, then click the Apply T est Mode button. • off(0) • five11(2)—511 is the pattern that is used when the pattern generator a ...

  • Patton electronic 1001MC - page 239

    Modem Information Rack X 239 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Modem Information Rack X The Modem Information Rack X page displays an ov ervie w of the N etLink rack that is being managed. This page will display statistical information, such as errors and warnings on a per-card basis, and identification information, ...

  • Patton electronic 1001MC - page 240

    Modem Information Rack X 240 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Rack Protection Mode If you want to protect all M odel 1095RC, 2701R C, and 2707R C rack cards installed in the current rack from being globally configured, select protected(1) from the pop-up menu, then click the Submit button. For mor e information abo ...

  • Patton electronic 1001MC - page 241

    Modem Information Rack X 241 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Line Status The line status column on each View Rack page shows the curr ent line status of each card. Keep in mind that the more car ds the 1001MC is managing, the longer it will take for the line status field to update. Displays the status of the line. ...

  • Patton electronic 1001MC - page 242

    Modem Information Rack X 242 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Remote Model Code (remoteModelCode) This column displays the model code of the N etLink modem at the far end of the link. Protected Y ou can protect individual rack cards from being globally configured by setting the pop-up menu fr om nor- mal(0) to prot ...

  • Patton electronic 1001MC - page 243

    Slot Configuration 243 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Slot Configuration The Slot Configuration page (see figure 118 ) enables you to make slot specific configuration changes that ar e not product specific. The following sections describe each variable. Figure 118. Slot Configuration Page Card Address (nmsS ...

  • Patton electronic 1001MC - page 244

    Slot Configuration 244 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference T o configure the local user ID, type the ID into the Local User ID text box, then click the Submit button {located next to the Remote User ID text box) to save the changes. Note After submitting the card identification information, you must click on the Reco ...

  • Patton electronic 1001MC - page 245

    Slot Configuration 245 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference T o configure the remote circuit ID, type the ID into the Remote Circuit ID text box, then click the Submit but- ton {located next to the Remote Circuit ID text box) to save the changes. Note After submitting the card identification information, you must clic ...

  • Patton electronic 1001MC - page 246

    System Information 246 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference System Information The System Information page (see figure 119 ) displays the current setting for the system. This page allows you to setup parameters defining password protection and the networ k address. A description of each variable follo ws figure 119 . ...

  • Patton electronic 1001MC - page 247

    System Information 247 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Modifying the IP addressing IP Address (boxIpAddress) This parameter defines the IP address of the box. T ype the address into the text box, then, if y ou have no other IP addressing entries to make, click the Submit button. IP Mask (boxIpMask) This parameter ...

  • Patton electronic 1001MC - page 248

    System Information 248 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Note After submitting the new superuser password, you must click on the Record Current Con fi guration button located on the HOME page to store the configuration changes into memory (see “HOME” on page 228 for more information). User Password (boxSnmpMoni ...

  • Patton electronic 1001MC - page 249

    Download 249 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference W eb Background Enabled (boxBackgroundFlag) The M odel 1001MC contains a background image that can be used while viewing the web pages. Y ou can choose to enable or disable the background image, then click on the S ubmit button to apply the change. The two options are: ? ...

  • Patton electronic 1001MC - page 250

    Download 250 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference • 1001MC with access to the LAN. Note F or help, type help at the FTP prompt for a list of the commands. 1. At the C:> DOS prompt on the PC, type the following: ftp <IP ADDRESS> where <IP ADDRESS> is the IP address of the 1001MC. The 1001MC will respond ...

  • Patton electronic 1001MC - page 251

    System Log 251 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Figure 121. System Log System Log The System Log page (see figur e 121 ) displays an overview of the system logging functions. The system log is a messaging system that stores information about the system as it is running. The following hyperlinks are avail- able for ...

  • Patton electronic 1001MC - page 252

    System Log—Modify 252 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Figure 122. System Log—Modify System Log—Modify The System Log—Modify page (see figure 122 ) allows y ou to modify the system log parameters. Y ou can choose which messages will be sent to the available message logging functions. Daemons Syslog Daemon I ...

  • Patton electronic 1001MC - page 253

    System Log—Modify 253 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference SNMP T rap Daemon IP Address (syslogTrapIP) SNMP traps are generated for line down , line up , car d lost , pow er supply 1 fail , and power supply 2 fail events. The specific trap numbers are as follows: The T rap IP address is assigned on the S ystem Log pa ...

  • Patton electronic 1001MC - page 254

    System Log—Modify 254 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Note After submitting the change, you must click on the Record Current Con fi guration button located on the HOME page to store the config- uration changes into memory (see “HOME” on page 228 for more information). Min Priority for Flash Storage S pecify ...

  • Patton electronic 1001MC - page 255

    System Log—Modify 255 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference uration changes into memory (see “HOME” on page 228 for more information). Unix Facility S pecify the minimum priority for a message that will be sent to Flash storage. The following options are available: • disable(0) • user(1) • mail(2) • daemon( ...

  • Patton electronic 1001MC - page 256

    System Log—Volatile Memory 256 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Maintenance Maintain Flash Storage (syslogFlashClear) This variable is used to notify you about the status of the flash storage area. The following options are available: • syslogFlashOK(0) • syslogFlashF ull(1)—If the flash storage area is fu ...

  • Patton electronic 1001MC - page 257

    System Log—Non-Volatile Memory 257 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference System Log—Non-V olatile Memory The System Log—V olatile Memor y page (see figure 124 ) contains a log of messages that have been sent to the flash storage are using the Min P riority for Flash S torage variable in the Syslog Modify page. Me ...

  • Patton electronic 1001MC - page 258

    SNMP 258 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference SNMP The SNMP Support Page (see figure 125 ) is where you can do wnload the MIBs used by the 1001MC. Y ou will need the MIBs if you will be using an SNMP N etwork Management Station and a standar d SNMP software package or MIB walking tool to manage your P atton NetLink S y ...

  • Patton electronic 1001MC - page 259

    System Config 259 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference System Config M odel 1095R C, 2701R C, and 2707RC rack car ds can be configured globally by templates you create. If you use this capability , you have the option to globally configur e some or all Model 1095R C, 2701R C, and 2707R C modems in multiple racks, or ...

  • Patton electronic 1001MC - page 260

    System Config 260 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Protecting a Model 1001 rack from global configuration Do the follo wing to protect a M odel 1001 rack: 1. S tarting from the HOME page, click on the Configure Car ds link to display the System Level Infor mation page see figure 126 . F igure 127 on page 261 show ...

  • Patton electronic 1001MC - page 261

    System Config 261 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Figure 127. W eb page navigation to System Level Infor mation page 2. U se the Rack Protection M ode pop-up menu (see figure 126 ) to select protected(1) . Note Setting the Rack P rotection Mode to normal(0) will enable the rack to receive new configurations throu ...

  • Patton electronic 1001MC - page 262

    System Config 262 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Protecting a Model 1095RC rack card from global configuration Do the follo wing to protect a single M odel 1095R C rack card: 1. S tarting from the HOME page, click on the following links: Configure Car ds > View Rack 1 (choose the rack you want to protect, in ...

  • Patton electronic 1001MC - page 263

    System Config 263 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference 2. Locate the card addr ess (see figure 128 on page 262) of the M odel 1095R C you want to protect. 3. Set the P rotected pop-up menu (see figure 128 on page 262) to protected(1) . Note Setting the P rotected option to normal(0) will enable the Model 1095R C to re ...

  • Patton electronic 1001MC - page 264

    System Config 264 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Notes on clock mode settings The Clock M ode Setting determines the source of timing for the link. M ost applications will use one of the following configurations: • internal-receiveR ecover(0) • external-receiveR ecover(1) There are special situations which wo ...

  • Patton electronic 1001MC - page 265

    System Config 265 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Procedure for creating a template Figure 130. Global Configuration Menu page Note Y ou can create as many as five templates, if you need to delete a tem- plate to make room for another , refer to section “” on page 271). Do the follo wing to create a template: ...

  • Patton electronic 1001MC - page 266

    System Config 266 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference 2. U se the Local DTE Rate pop-up menu to select local DTE rate. Y ou have the following choices: 3. U se the Local Clock Mode (Local-R emote) pop-up menu to select the clock mode. Y ou have the following choices: – internal-receiveR ecover(0) – external-receive ...

  • Patton electronic 1001MC - page 267

    System Config 267 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference – normal(3) 9. Configure the Remote F raming M ode pop-up menu using the following choices: – slotted(0) – normal(3) 10. When you have finished setting the configuration, click on the Submit button to save the changes. Note If you receiv e an invalid confi ...

  • Patton electronic 1001MC - page 268

    System Config 268 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference the unit, so it is not necessary to have a G.703/G.704 link available. When using any other type of serial inter- face, make sure that an external clock is pro vided by the DTE equipment or the modems will not link. Notes on clock mode settings The Clock M ode Setti ...

  • Patton electronic 1001MC - page 269

    System Config 269 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Procedure for modifying a template Figure 132. Global Configuration Menu page Do the follo wing to modify a template: 1. Select a template from the Modify Configuration pop-up menu (see figure 130 ), then click the Modify Con fi guration button. The Model 1095 G ...

  • Patton electronic 1001MC - page 270

    System Config 270 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference 2. U se the Local DTE Rate pop-up menu to select local DTE rate. Y ou have the following choices: 3. U se the Local Clock Mode (Local-R emote) pop-up menu to select the clock mode. Y ou have the following choices: – internal-receiveR ecover(0) – external-receive ...

  • Patton electronic 1001MC - page 271

    System Config 271 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference – normal(3) 9. Configure the Remote F raming M ode pop-up menu using the following choices: – slotted(0) – normal(3) 10. When you have finished setting the configuration, click on the Submit button to save the changes. Note If you receiv e an invalid confi ...

  • Patton electronic 1001MC - page 272

    System Config 272 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference • M odel 1095R C rack cards that hav e had the Protected option set to protected(1) will not be configured if a global template is applied (see section “P rotecting a M odel 1095R C rack card from global configuration ” on page 262 for more information. Sele ...

  • Patton electronic 1001MC - page 273

    System Config 273 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Figure 136. W eb page navigation to System Level Infor mation page 2. U se the Apply S ystem Configur ation pop-up menu (see figure 135 ) to select the template you want to apply . 3. Click the Apply Con fi guration button. The template has been applied. ...

  • Patton electronic 1001MC - page 274

    System Config 274 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Configure all Model 1095RC rack cards in one Model 1001 rack Do the follo wing to apply global configuration to all Model 1095R C rack cards installed in one M odel 1001 rack: 1. S tarting from the HOME page, click on the Configure Car ds link to display the Syst ...

  • Patton electronic 1001MC - page 275

    Help 275 Model 1001MC Operations Guide 10 • HTTP/HTML web page reference Help The Help Menu page (see figure 138 ) pro vides hyperlinks to help pages located within the 1001MC. Applica- tions notes are also available on the M odel 1001MC CD-ROM or b y contacting P atton Electronics T echnical S upport. Figure 138. Global Configuration Menu page ...

  • Patton electronic 1001MC - page 276

    276 Chapter 11 T roubleshooting and maintenance Chapter contents Introduction ........................................................................................................................................................277 Troubleshooting the 1001MC rack card ............................................................................... ...

  • Patton electronic 1001MC - page 277

    Introduction 277 Model 1001MC Operations Guide 11 • Troubleshooting and maintenance Introduction This chapter describes troubleshooting and fault analysis that can be performed by the operator . This section contains the following sections to help you tr oubleshoot the 1001MC rack card and N etLink rack cards: • T roubleshooting the 100MC rack ...

  • Patton electronic 1001MC - page 278

    Troubleshooting network malfunctions 278 Model 1001MC Operations Guide 11 • Troubleshooting and maintenance T roubleshooting network malfunctions U sing the M odel 1001MC to troubleshoot a network problem generally inv olves the following steps: 1. Receiving notification that there is a pr oblem. 2. V erifying that the problem exists. 3. Checkin ...

  • Patton electronic 1001MC - page 279

    Troubleshooting network malfunctions 279 Model 1001MC Operations Guide 11 • Troubleshooting and maintenance 3. If no T op Level racks are sho wing warnings or errors, go to section “U sing the System Log to check for net- work problems ” on page 282 to review the System Log: Non-V olatile Memor y page for information on what may have caused t ...

  • Patton electronic 1001MC - page 280

    Troubleshooting network malfunctions 280 Model 1001MC Operations Guide 11 • Troubleshooting and maintenance Figure 141. System Level Information page displaying warnings and errors ...

  • Patton electronic 1001MC - page 281

    Troubleshooting network malfunctions 281 Model 1001MC Operations Guide 11 • Troubleshooting and maintenance 4. Make a note of which rack car ds or power supplies ar e showing errors or warnings (see figur e 142 ). Then go to section “U sing the System Log to check for network pr oblems ” on page 282 t o r eview the System Log: Non-V olatile ...

  • Patton electronic 1001MC - page 282

    1001MC test mode diagnostics 282 Model 1001MC Operations Guide 11 • Troubleshooting and maintenance Using the System Log to check for network problems The System Log (see figure 143 ) is a messaging system that stor es information about the system as it is running. Do the follo wing to display the System Log: Non-V olatile Memor y page for help ...

  • Patton electronic 1001MC - page 283

    1001MC test mode diagnostics 283 Model 1001MC Operations Guide 11 • Troubleshooting and maintenance bits match the agreed aupon pseudo-random pattern, then the N etLink modems and the communication link are functioning properly . • five11er (511 with errors)—After successfully concluding a five11 test, use the five11er test (which ran- dom ...

  • Patton electronic 1001MC - page 284

    Maintenance 284 Model 1001MC Operations Guide 11 • Troubleshooting and maintenance • rdlW ith511er (remote loopback with 511 and errors)—This test functions the same way as the r dlWith511 test, but it adds a 511 pattern from the BER generator that includes errors to verify that the modems can detect the errors. Note Refer to table 17 to see ...

  • Patton electronic 1001MC - page 285

    Maintenance 285 Model 1001MC Operations Guide 11 • Troubleshooting and maintenance 2. Disconnect from the malfunctioning M odel 1001MC and label the 10Base-T Ethernet cable and RS-232 configuration/daisy-chain cable (if installed). 3. Loosen the captive fasteners located on the front car d until it is not longer attached to the rack chassis, whe ...

  • Patton electronic 1001MC - page 286

    286 Chapter 12 Contacting Patton for assistance Chapter contents Introduction ........................................................................................................................................................287 Contact information ................................................................................................ ...

  • Patton electronic 1001MC - page 287

    Introduction 287 Model 1001MC Operations Guide 12 • Contacting Patton for assistance Introduction This chapter contains the following information: • “Contact information ”—describes how to contact P atton technical suppor t for assistance. • “W arranty Service and Returned Mer chandise Authorizations (RMAs)”—contains information a ...

  • Patton electronic 1001MC - page 288

    Warranty Service and Returned Merchandise Authorizations (RMAs) 288 Model 1001MC Operations Guide 12 • Contacting Patton for assistance Return for credit policy • Less than 30 days: N o Charge. Y our credit will be issued upon receipt and inspection of the equipment. • 30 to 120 days: W e will add a 20% restocking charge (crediting your accou ...

Manufacturer Patton electronic Category Card Game

Documents that we receive from a manufacturer of a Patton electronic 1001MC can be divided into several groups. They are, among others:
- Patton electronic technical drawings
- 1001MC manuals
- Patton electronic product data sheets
- information booklets
- or energy labels Patton electronic 1001MC
All of them are important, but the most important information from the point of view of use of the device are in the user manual Patton electronic 1001MC.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Patton electronic 1001MC, service manual, brief instructions and user manuals Patton electronic 1001MC. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Patton electronic 1001MC.

A complete manual for the device Patton electronic 1001MC, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Patton electronic 1001MC by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Patton electronic 1001MC.

A complete Patton electronic manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Patton electronic 1001MC - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Patton electronic 1001MC, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Patton electronic 1001MC, that we can find in the current document
3. Tips how to use the basic functions of the device Patton electronic 1001MC - which should help us in our first steps of using Patton electronic 1001MC
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Patton electronic 1001MC
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Patton electronic 1001MC in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Patton electronic 1001MC?

Use the form below

If you did not solve your problem by using a manual Patton electronic 1001MC, ask a question using the form below. If a user had a similar problem with Patton electronic 1001MC it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)