Black Box AC444A - page 1
JUNE 2000 AC444A AC444AE AC445A-TX AC446A-RX FiberPath CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mail order: Black Box Corporation , 1000 Park Drive, Lawrence, PA 15055-1018 Web site: w ...
-
Black Box AC444A - page 2
1 FIBERPATH FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been test ...
-
Black Box AC444A - page 3
2 FIBERPATH NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY STATEMENT INSTRUCCIONES DE SEGURIDAD 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura. 3. Todas las advertencias en el ap ...
-
Black Box AC444A - page 4
3 FIBERPATH 10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u otros aparatos (incluyendo amplificadores) que producen calor . 11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique ...
-
Black Box AC444A - page 5
4 FIBERPATH TRADEMARKS Any trademarks mentioned in this manual are acknowledged to be the property of the trademark owners. ...
-
Black Box AC444A - page 6
5 FIBERPATH CONTENTS 1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2. Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.2 What the Package Includes . . . . . . . . . . . . . 8 3. Installation . . . . . . . . . . . . . . . . . . ...
-
Black Box AC444A - page 7
6 FIBERPATH 1. Specifications Certification — For FiberPath: FCC Class A, Subpart B of Part 155 compliance; For the power supply: UL ® , CSA listed Input/Output Voltage — 1 volt pp (user-adjustable at receiver) Input/Output Impedance — 75 ohms Signal/Noise Ratio (per RS-250) — 52 dB minimum Differential Gain (per RS-250) — 2% typical Dif ...
-
Black Box AC444A - page 8
7 FIBERPATH Operating Power (per unit) — All units except AC444AE: 12V ±10% D @ 100 ma max.; FiberPath comes with two 115-VAC-to-12-VDC plug-in wall adapters which can be used to supply all operating power; AC444AE: (2) power supplies (receiver and transmitter) that are 220 to 230 volts with special international plugs, 50 Hz, 9 VDC @ 500 mA Ope ...
-
Black Box AC444A - page 9
8 FIBERPATH 2. Intr oduction 2.1 General The FiberPath is a high-quality, cost-effective fiberoptic video transmission system designed to transmit color and black-and-white signals over distances of more than a mile. The system is easy to install and is designed for long, trouble-free operation in most indoor or outdoor protected environments. The ...
-
Black Box AC444A - page 10
9 FIBERPATH • (2) 12-VDC Power Supplies • This User Manual For the AC444AE, your package includes: • (1) FiberPath Transmitter • (1) FiberPath Receiver • (2) 220-to-230-Volt, 9-VDC Power Supplies • This User Manual For the AC445A-TX, your package includes: • (1) FiberPath Transmitter • This User Manual For the AC446A-RX, your packag ...
-
Black Box AC444A - page 11
10 FIBERPATH 3. Installation Figure 3-1 on page 12 may provide assistance during installation. Follow these steps: 1. Mount the FiberPath Transmitter at the camera or source of video to be transmitted. Use the mounting tabs on the housing or the enclosed self-adhesive mounting pad. 2. Connect one of the plug-in power supplies to the input connector ...
-
Black Box AC444A - page 12
11 FIBERPATH 4. Mount the FiberPath Receiver at the monitor or device where the video will be received. Use the mounting tabs on the housing or the enclosed self-adhesive mounting pad. 5. Connect the remaining plug-in power supply to the FiberPath Receiver’s input connector. If you plan to use an external power source, make sure it provides regul ...
-
Black Box AC444A - page 13
12 FIBERPATH Figure 3-1. Installation of the FiberPath Fiberoptic Transmission System. DC Common +12VDC ± 10% CCTV Camera or other Video Source Video Monitor or Other Receiver Coaxial Cable Coaxial Cable Transmitter 12 VDC 12 VDC ST Type Optical ST Type Optical Level Adjust Power Adapter Power Adapter Receiver 62.5 µ Fiberoptic Cable ...
-
Black Box AC444A - page 14
13 FIBERPATH 4. T r oubleshooting If your FiberPath transmission system does not immediately operate, follow this checklist: 1. Is the correct operating power present and connected to the proper pins on the power connector? If so, the red PWR LED should glow. 2. If you’re using an external power source, does it matter that the signal and power gr ...
-
Black Box AC444A - page 15
14 FIBERPATH If all of the troubleshooting items on the checklist are correct and the system still will not operate correctly, call Black Box Technical Support at 724-746-5500. ...
-
Black Box AC444A - page 16
1000 Park Drive • Lawrence, PA 15055-1018 • 724-746-5500 • Fax 724-746-0746 © Copyright 2000. Black Box Corporation. All rights reserved. ...
Do you have a question concerning Black Box AC444A?
Use the form below
If you did not solve your problem by using a manual Black Box AC444A, ask a question using the form below. If a user had a similar problem with Black Box AC444A it is likely that he will want to share the way to solve it.