Manual Oregon Scientific BAR888

14 pages 0.44 mb
Download

Go to site of 14

Summary
  • Oregon Scientific BAR888 - page 1

    1 GB WEATHER FORECAST MULTI-CHANNEL IN-OUT THERMOMETER WITH CABLE FREE SENSOR AND RADIO CONTROLLED CLOCK MODEL: BAR888 USER’S MANUAL INTRODUCTION Congratulations on your purchase of the BAR888 Weather Fore- cast Multi-Channel In-Out Thermometer with 433MHz cable free sensor and radio-controlled calendar clock. The basic package comes with a main ...

  • Oregon Scientific BAR888 - page 2

    2 GB FIVE-LINE DISPLAY Facilitates easy reading of weather forecast, remote and indoors temperatures and calendar clock CHANNEL BUTTON Selects among different channels MEMORY BUTTON Recalls the maximum or minimum temperature of individual channels ALARM ( ) ON/OFF BUTTON Enables or disables the alarms ALARM/ 24hr OFF BUTTON Sets the time for the al ...

  • Oregon Scientific BAR888 - page 3

    3 GB LCD Displays the current temperature monitored by the remote unit LED INDICATOR Flashes when the remote unit transmits a reading °C/°F SLIDE SWITCH Selects between Centigrade (°C) and Fahrenheit (°F) CHANNEL SLIDE SWITCH Designates the remote unit Channel 1, Channel 2 or Channel 3 RESET BUTTON Returns all settings to default values; press ...

  • Oregon Scientific BAR888 - page 4

    4 GB 4. Insert the batteries strictly according to the polarities shown therein. 5. Replace the battery compartment door and secure its screws. 6. Using a blunt styles such as a paper clip, press RESET. Note: To avoid malfunction, alway press reset after battery replacement. Replace the batteries when the low-battery indicator of the particu- lar c ...

  • Oregon Scientific BAR888 - page 5

    5 GB 3. Replace the battery compartment door. Replace the batteries when the low-battery indicator of the indoors temperature lights up. (Repeat the steps described in section “BEFORE YOU BEGIN”) LOW BATTERY WARNING When it is time to replace batteries, the respective low-battery indicator will show up when the respective channel is selected. T ...

  • Oregon Scientific BAR888 - page 6

    6 GB THE RESET BUTTON This button is only used when the unit is operating in an unfavorable way or malfunctioning. Use a blunt stylus to hold down the button. All settings will return to their default values. GETTING STARTED Once batteries are in place for the remote units, they will start transmitting temperature readings at 30-second intervals. T ...

  • Oregon Scientific BAR888 - page 7

    7 GB HOW TO READ THE KINETIC WAVE DISPLAY The kinetic wave display shows the signal receiving status of the main unit. There are three possible forms: The unit is in searching mode. Temperature readings are securely registered. No signals. MAXIMUM AND MINIMUM TEMPERATURES The maximum and minimum recorded indoor temperatures and those of each channe ...

  • Oregon Scientific BAR888 - page 8

    8 GB WEATHER FORECAST FUNCTION Your BAR888 detects barometric pressure changes and the LCD displays the illustrated weather symbols which indicates the weather forecast for 12 to 24 hours ahead, for an area with a radius of about 30-50 km. Important: 1. The accuracy of weather forecasting when using pressure trend alone is about 70 to 75 percent an ...

  • Oregon Scientific BAR888 - page 9

    9 GB When the reception is complete, the radio reception signal will stop blinking. The strength of the reception for the last full hour will be indicated. For better reception, place the clock away from metal objects and electrical appliances to minimize interference. If you wish to disable the auto-reception feature, press the ( ) button for thre ...

  • Oregon Scientific BAR888 - page 10

    10 GB HOW TO SET THE CLOCK MANUALLY To set the clock manually, hold MODE/SET for three seconds. The display will return to MODE 1, with the hour digits blinking. Use ( ) or ( ) to select the hour. Press and hold to increase or decrease the value rapidly. Press MODE/SET to confirm. The minute digits will blink. Repeat the same procedure to set the m ...

  • Oregon Scientific BAR888 - page 11

    11 GB TIME ZONE AND OFFSET TABLE SPECIFICATIONS Temperature Measurement Main unit Indoor Temperature measurement Displayed IN temperature range : -9.9°C to +70.0°C (14.2°F to 158.0°F) Proposed operating range : -5.0°C to +50.0°C (23.0°F to 122.0°F) Temperature resolution : 0.1°C (0.2°F) HOW TO STOP AN ALARM To stop an alarm, you can use e ...

  • Oregon Scientific BAR888 - page 12

    12 GB Remote Temperature measurement Displayed OUT temperature range : -50.0°C to +70.0°C (-58.0°F to 158.0°F) Proposed operating range : -5.0°C to +50.0°C (23.0°F to 122.0°F) Temperature resolution : 0.1°C (0.2°F) Remote unit Displayed range : -50.0°C to +70.0°C (-58.0°F to 158.0°F) Proposed operating range : -20.0°C to +60.0°C (-4 ...

  • Oregon Scientific BAR888 - page 13

    13 GB instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful inter- ference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to ...

  • Oregon Scientific BAR888 - page 14

    14 GB MODEL: BAR888 WEA THER FORECAST MUL TI-CHANNEL IN-OUT THERMOMETER WITH CABLE FREE SENSOR AND RADIO CONTR OLLED CLOCK Instruction Manual **** Mode D'emploi **** Bedienungsanleitung **** Manuale di Istruzioni **** Instrucciones de Funcionamiento ...

Manufacturer Oregon Scientific Category Thermometer

Documents that we receive from a manufacturer of a Oregon Scientific BAR888 can be divided into several groups. They are, among others:
- Oregon Scientific technical drawings
- BAR888 manuals
- Oregon Scientific product data sheets
- information booklets
- or energy labels Oregon Scientific BAR888
All of them are important, but the most important information from the point of view of use of the device are in the user manual Oregon Scientific BAR888.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Oregon Scientific BAR888, service manual, brief instructions and user manuals Oregon Scientific BAR888. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Oregon Scientific BAR888.

A complete manual for the device Oregon Scientific BAR888, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Oregon Scientific BAR888 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Oregon Scientific BAR888.

A complete Oregon Scientific manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Oregon Scientific BAR888 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Oregon Scientific BAR888, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Oregon Scientific BAR888, that we can find in the current document
3. Tips how to use the basic functions of the device Oregon Scientific BAR888 - which should help us in our first steps of using Oregon Scientific BAR888
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Oregon Scientific BAR888
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Oregon Scientific BAR888 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Oregon Scientific BAR888?

Use the form below

If you did not solve your problem by using a manual Oregon Scientific BAR888, ask a question using the form below. If a user had a similar problem with Oregon Scientific BAR888 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)