Manual Hobart & PEQ SERIES

12 pages 0.94 mb
Download

Go to site of 12

Summary
  • Hobart & PEQ SERIES - page 1

    QE, EQE, QEH, & PEQ SERIES ROLL-IN, ROLL-THROUGH FOOD ST ORAGE CABINETS AND PROOFERS 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 937 332-3000 www.hobartcorp.com FORM 18529 Rev. E (Jan. 2000) N S T R U C T I O N S I ...

  • Hobart & PEQ SERIES - page 2

    – 2 – QE Series Roll-In Food Storage Cabinets ...

  • Hobart & PEQ SERIES - page 3

    – 3 – © HOBART CORPORATION, 1992 Installation, Operation, and Care of QE, EQE, QEH, & PEQ SERIES ROLL-IN FOOD ST ORAGE CABINETS & PROOFERS SA VE THESE INSTRUCTIONS GENERAL The QE and EQE Series Roll-in Food Storage Cabinets are available as medium temperature (38 ° F) or frozen food (0 ° F) storage cabinets. The QEH Series is availab ...

  • Hobart & PEQ SERIES - page 4

    – 4 – Door(s) and hinges can be removed, as follows: 1. Lift up and remove the front trim panel (Fig. 2). 2 . Remove the screws which secure the trim rail cover (Fig. 2), unplug the door switch lead wires and remove the screws which secure the trim rail (Fig. 2). Carefully lay the trim rail on top of the cabinet — avoid damaging or kinking th ...

  • Hobart & PEQ SERIES - page 5

    – 5 – On pass thru models, the recessed floor dimension allows 2 1 / 4 " clearance at both front and rear and 1 / 2 " on both sides. On a front opening cabinet, the recessed floor dimension allows 2 1 / 4 " clearance at the front, 1 1 / 2 " clearance at the rear, and 1 / 2 " on both sides (Fig. 5). The plug for the heat ...

  • Hobart & PEQ SERIES - page 6

    – 6 – PLUMBING CONNECTIONS (PEQ Series Proofer only) WARNING : PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITARY, SAFETY, AND PLUMBING CODES. Make sure the water supply has proper hardness and pH. The recommended water hardness range is 4 – 6 grains per gallon. The recommended pH range is 6.5 to 8.0. Consult your local water company a ...

  • Hobart & PEQ SERIES - page 7

    – 7 – OPERA TION CONTROLS (Refrigeration) TEMPERATURE CONTROL — The temperature control is set at the factory, but local conditions may necessitate slight adjustment. To adjust the temperature control, lift up and remove the front trim panel (see Fig. 2) and turn the control knob (Fig. 9 or 10) a small amount at a time. Turning the control kn ...

  • Hobart & PEQ SERIES - page 8

    – 8 – CONTROLS — Proofer and Thaw Proofer (Figs. 12 & 13) On-Off Switch Turns the Proofer Control On or Off. The On-Off switch is not a disconnect switch — ALWAYS DISCONNECT POWER AT THE SOURCE TO SERVICE THE CABINET . ON OFF TEMP normally displays the Set-Point Temperature. To adjust the Set-Point Temperature, press and hold SET while ...

  • Hobart & PEQ SERIES - page 9

    – 9 – CONTROLS — Thaw Proofer (Fig. 13) Thaw Proofer TEMP SET VI EW • F SET % HUM TIMER SET START ▲ ▼ • SET T H A W PR OOF AUTO M ATI C • • • MO D E ON OFF Fig. 13 Press MO D E and ▲ or ▼ to select Proof, Set Thaw, or Automatic mode. The mode lights indicate control function : M ANUAL P ROOF mode allows you to set Temperatur ...

  • Hobart & PEQ SERIES - page 10

    – 10 – REMOTE CONTROL — Proofer and Thaw Proofer (When Equipped) Connect Remote Control 'Phone Jack' to Terminal on Electrical Box on Top of Unit Fig. 14 The Remote Control is used in conjunction with either Proofer Controls or Thaw Proofer Controls described on pages 8 – 9. The MODE key is used only on Thaw Proofer models. CONTRO ...

  • Hobart & PEQ SERIES - page 11

    – 11 – MAINTENANCE CLEANING Cabinet Clean the inside of the cabinet and the doors weekly with a warm water solution of mild household liquid dishwashing detergent (such as Palmolive green or Ivory). Do not use anything containing grit, abrasive materials, bleach or harsh chemicals. Be cautious with new or improved formulas; use only after being ...

  • Hobart & PEQ SERIES - page 12

    – 12 – FORM 18529 Rev. E (Jan. 2000) PRINTED IN U.S.A. — NOTES — ...

Manufacturer Hobart Category Mixer

Documents that we receive from a manufacturer of a Hobart & PEQ SERIES can be divided into several groups. They are, among others:
- Hobart technical drawings
- & PEQ SERIES manuals
- Hobart product data sheets
- information booklets
- or energy labels Hobart & PEQ SERIES
All of them are important, but the most important information from the point of view of use of the device are in the user manual Hobart & PEQ SERIES.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Hobart & PEQ SERIES, service manual, brief instructions and user manuals Hobart & PEQ SERIES. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Hobart & PEQ SERIES.

Similar manuals

A complete manual for the device Hobart & PEQ SERIES, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Hobart & PEQ SERIES by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Hobart & PEQ SERIES.

A complete Hobart manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Hobart & PEQ SERIES - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Hobart & PEQ SERIES, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Hobart & PEQ SERIES, that we can find in the current document
3. Tips how to use the basic functions of the device Hobart & PEQ SERIES - which should help us in our first steps of using Hobart & PEQ SERIES
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Hobart & PEQ SERIES
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Hobart & PEQ SERIES in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Hobart & PEQ SERIES?

Use the form below

If you did not solve your problem by using a manual Hobart & PEQ SERIES, ask a question using the form below. If a user had a similar problem with Hobart & PEQ SERIES it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)