Manual ResMed RPS II

16 pages 1.02 mb
Download

Go to site of 16

Summary
  • ResMed RPS II - page 1

    Respiratory Care Solutions P o w er Station II BA TTERY P ACK User Guide English ...

  • ResMed RPS II - page 2

    P o w er Station II BA TTERY P ACK / AKKUP ACK / BA TTERIE / ALIMENT A TORE A BA TTERIA / BA TERÍA / BA TERIA / ACCU / BA TTERIP ACK / BA TTERIP AKKE / BA TTERIP AKKE / AKKU / ΜΠΑ ΤΑΡΙΑ / 电池包 / 電池包 2 1 2 3 8 4 5 6 7 9 B 1 2 3 C 1 2 3 4 5 6 7 a DC plug / Gleichstromstecker / F iche CC / Spinotto DC / Enchufe de C C / Ficha CC / ...

  • ResMed RPS II - page 3

    3 2 1 4 D * 3 4 5 2 1 6 E * 1 2 3b 3a * * Example device illustration only / Abbildung eines Beispielgerätes / Exemple d’appar eil / Illustrazione dell’apparecchio a solo titolo di esempio / Ilustración del dispositivo proporcionada a modo de ejemplo únicamente / Ilustração de dispositiv o apenas para exemplo / Uitsluitend voorbeeldillustr ...

  • ResMed RPS II - page 4

    i P o w er Station II DC output v oltage & DC cables 24V 26V DC Cable Par t Number VP AP ™ III ST -A  24959 VP AP ™ III ST -A with Quic kNav  24959 VP AP ™ Auto 25  24960 VP AP ™ S, VP AP ™ ST  24960 VP AP ™ IV , VP AP ™ IV S T  24960 S8 ™ Auto 25  24960 S9 ™ Series  24961 Stellar ™  24959 (24981 for ...

  • ResMed RPS II - page 5

    ii Svenska Obs! • Vissa utrustningar finns inte i alla delar a v världen. • För inf ormation om batteriernas körtider hän visas till Produktkompatibilitetslista för bat terier/ utrustningar på www .resmed.com. Dansk Bemærkninger: • Det er ikke alle apparater , der kan fås i alle lande. • Der er oplysninger om bat teriers driftstid ...

  • ResMed RPS II - page 6

    English 1 Intended use The R esMed P ower Station II (RPS II) is an external lithium-ion bat ter y that provides pow er when mains pow er is unav ailable. Please read the entire guide before using the RPS II. R ef er to the device user guides for intended patients, uses and contraindications associated with CP AP , bilev el and ventilation therap y ...

  • ResMed RPS II - page 7

    2 Set ting up CA UTION • Ensure the RPS II and the device are turned off before set ting up. • When the RPS II is plugged to the mains power supply , ensure all cables are properly connected. Charging the bat tery Ref er to illustration C . 1. At t ac h the pow er supply unit adapter to the DC plug and connect into the bat ter y DC input/output ...

  • ResMed RPS II - page 8

    English 3 2. Plug the bat ter y coupler cables into eac h of the bat ter y DC input/output ports. The bat ter y coupler cables are marked with ‘1’ (primar y) and ‘2’ (reser ve) labels. 3. a. When c harging t wo bat teries, at tach the po wer supply unit adapter to the DC plug and connect the adapter to the the bat ter y coupler . b. When po ...

  • ResMed RPS II - page 9

    4 Using humidifi ers When a device integrated with the HumidAire 2i ™ or H4i ™ humidifi er is not connected to the mains pow er supply , the humidifi er will only operate in passive unheated mode despite the warm-up message appearing on the de vice. When the device is connected to the mains pow er supply , it will return to activ e heated mo ...

  • ResMed RPS II - page 10

    English 5 T r oubleshooting If there is a problem, tr y the follo wing suggestions. If the problem cannot be solved, contact your equipment supplier or ResMed. Do not at tempt to open the bat ter y . Problem/P ossible cause Solution Device is not running P ower connections are disr upted. Chec k all cables and connect them as described in Set ting ...

  • ResMed RPS II - page 11

    6 T ec hnical specifications Bat ter y tec hnology Lithium ion Capacity < 1 0 0 Wh (97 Wh) UN classification UN3481 (lithium-ion bat teries pack ed with equipment) P ower supply Input range 1 00–240V , 50–60Hz, 1 .0-1 .5A Nominal for aircraf t use 1 1 0V , 40 0Hz Bat ter y output voltage (24V / 26V) ± 0.5V , 90W continuous P ower supply u ...

  • ResMed RPS II - page 12

    English 7 Symbols The f ollowing symbols ma y appear on the device or pac kaging: At tention, consult accompanying documents; Read instructions bef ore use; Drip proof; No protection; Class II equipment; European RoHS; Batc h Code; Serial number; Catalogue number; 8 Maximum humidity; T emperature limitation (storage and transport); Charging; Bat te ...

  • ResMed RPS II - page 13

    8 • Make sure to periodically recharge the bat tery due to effects of self- disc harging. • As the battery ages, the available capacity decreases. When the remaining battery capacity is get ting low, do not rely on the RPS II as the primary supply . • Ensure the internal battery of an y connected device is k ept c harged up to provide bac kup ...

  • ResMed RPS II - page 14

    English 9 Limited w arr anty ResMed Ltd (hereafter ’ResMed’) warrants that your ResMed product shall be free from defects in material and workmanship from the date of purchase for the period specified below. Product W arranty period • Mask systems (including mask frame, cushion, headgear and tubing)—e xcluding single-use de vices • Acces ...

  • ResMed RPS II - page 15

    10 This w arranty gives y ou specific legal rights, and you ma y also hav e other rights whic h vary from region to region. For further inf ormation on your w arranty rights, contact your local R esMed dealer or ResMed of fice. ...

  • ResMed RPS II - page 16

    Global leaders in sleep and respiratory medicine www .resmed.com 248527/2 20 1 2-07 P ow er Station II USER ROW MUL TI Respiratory Care Solutions Manufacturer: ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia. Distributed by: ResMed Corp 9001 Spectrum Center Boulevard San Diego CA 92123 USA. ResMed (UK) Ltd 96 Milton Park Abing ...

Manufacturer ResMed Category Marine Instruments

Documents that we receive from a manufacturer of a ResMed RPS II can be divided into several groups. They are, among others:
- ResMed technical drawings
- RPS II manuals
- ResMed product data sheets
- information booklets
- or energy labels ResMed RPS II
All of them are important, but the most important information from the point of view of use of the device are in the user manual ResMed RPS II.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals ResMed RPS II, service manual, brief instructions and user manuals ResMed RPS II. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product ResMed RPS II.

A complete manual for the device ResMed RPS II, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use ResMed RPS II by users. Manuals are usually written by a technical writer, but in a language understandable to all users of ResMed RPS II.

A complete ResMed manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual ResMed RPS II - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the ResMed RPS II, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the ResMed RPS II, that we can find in the current document
3. Tips how to use the basic functions of the device ResMed RPS II - which should help us in our first steps of using ResMed RPS II
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with ResMed RPS II
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of ResMed RPS II in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning ResMed RPS II?

Use the form below

If you did not solve your problem by using a manual ResMed RPS II, ask a question using the form below. If a user had a similar problem with ResMed RPS II it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)