    USER'S GUIDE JY992D53201C This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX and FX 0N , 485 communication adapters. It should be read and understood before attempt- ing to install or use these units. Further information can be found in the FX PROGRAMMING MANUAL, ...

  • Mitsubishi Electronics FX-485ADP - page 2

    1 INTRODUCTION ①⑥ LINK SG SDB SDA RDB RDA FG 24+ 24G 〈 FX-485ADP 〉 MITSUBISHI FX-485ADP ① Direct mounting hole ② Power LED · · · ③ R D L E D ······· ④ S D L E D ······· ⑤ Terminal screws (M3 (0.12)) ⑥ Extension cable ⑦ Terminal cover ⑧ Groove for mounting DIN rail (DIN rail width : 35 (1.38)) ⑨ Hook for mo ...

  • Mitsubishi Electronics FX-485ADP - page 3

    Station No.15 ↑ FX series PC Max. 16 stations including A series PCs (total extension distance 500m) (2) Computer and PC by 1 : n configuration In this case, the number of link stations is 16 PCs at maximum for one computer, including the FX series PCs and A series PCs. Such system of data exchange with plural PCs with one computer is called the ...

  • Mitsubishi Electronics FX-485ADP - page 4

    For setting up the system, the 485ADP can be connected to the following PCs. PC series FX 0N FX , FX 2C PC version Ver. 1.20 or later Ver. 3.30 or later Remarks Exclusive protocol format 1 and format 4 are supported. Exclusive protocol format 1 and format 4 are supported. FX 0N -485ADP FX-485ADP As for exclusive protocol formats (1, 4) , see the 48 ...

  • Mitsubishi Electronics FX-485ADP - page 5

    *1 R is the terminating resistance. Connect the terminating resistance (330 Ω ) between terminals SDA and SDB , and terminals RDA and RDB . For details see section 2.3. *2 Connect terminal FG to earth terminal of the PC main body grounded with resistance of 100 Ω or less. However, as for the computer link unit of the A series PC, see the manual ...

  • Mitsubishi Electronics FX-485ADP - page 6

    *1 R is the terminating resistance. Connect the terminating resistance (110 Ω ) between terminals RDA and RDB . For details see section 2.3. *2 Connect terminal FG to earth terminal of the PC main body grounded with resistance of 100 Ω or less. However, as for the computer link unit of the A series PC, see the manual of the computer link unit. ...

  • Mitsubishi Electronics FX-485ADP - page 7

    Classification of terminating resistances In this product, two sets of terminal end resistances (330 Ω ✕ 2, 110 Ω ✕ 1) are packaged, and the terminating resistances to be connected differ as shown below depending on the circuit being used. ● When communicating with the RS-422 circuit, connect the resistances of “330 Ω 1/4W ” as the ...

  • Mitsubishi Electronics FX-485ADP - page 8

    FX 0N FX, FX 2C The communication format of the PC is set using special D8120. Operating ambient temperature Humidity no condensation Shock resistance Noise immunity Dielectric withstand voltage Insulation resistance Ground Operating ambience 3 Environmental specifications Vibration resistance 0 to 55°C, storage temperature -20 to 70°C 35 to 85% ...

  • Mitsubishi Electronics FX-485ADP - page 9

    X0000 ~ X0177 Y0000 ~ Y0177 M0000 ~ M0511 S0000 ~ S0127 M0000 ~ M8254 TS000 ~ TS063 CS000 ~ CS031 CS235 ~ CS254 TN000 ~ TN063 CN000 ~ CN031 CN235 ~ CN254 D0000 ~ D0255 D1000 ~ D2499 D8000 ~ D8255 ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) X,Y,M,S T,C , D 4 Symbol ASCII code Command Function Objective device symbol Number of processing poin ...

  • Mitsubishi Electronics FX-485ADP - page 10

    In case of trouble, check the following points, and remedy according to the troubleshooting guide in the 485PC- IF manual. (1) Power LED Lit Otherwise (2) As for SD LED, RD LED, check and remedy according to the troubleshooting guide in the 485PC-IF manual. 5 DIAGNOSTICS : The extension cable is normally connected to the PC. : The extension cable i ...

  • Mitsubishi Electronics FX-485ADP - page 11

    Prior to start of operation, follow the procedure below. As for detail of procedure, see the 485PC-IF manual. 6 Determine system configuration Setting of transfer specification (D8120) Setting of station number (D8120) Setting of time-out check time (D8129) (1) (2) (3) Specification of data length Specification of parity Specification of stop bit S ...

  • Mitsubishi Electronics FX-485ADP - page 12

    Guidelines for the safety of the user and protection of the FX-485ADP, FX 0N -485ADP communication adapter JY992D53201C Effective AUG. 1997 Specifications are subject to change without notice. HEAD OFFICE : MITSUBISHI DENKI BLDG MARUNOUCH TOKYO 100 TELEX : J24532 CABLE MELCO TOKYO HIMEJI WORKS : 840, CHIYODA CHO, HIMEJI, JAPAN ● This manual has b ...

Manufacturer Mitsubishi Electronics Category Computer Accessories

Documents that we receive from a manufacturer of a Mitsubishi Electronics FX-485ADP can be divided into several groups. They are, among others:
- Mitsubishi Electronics technical drawings
- FX-485ADP manuals
- Mitsubishi Electronics product data sheets
- information booklets
- or energy labels Mitsubishi Electronics FX-485ADP
All of them are important, but the most important information from the point of view of use of the device are in the user manual Mitsubishi Electronics FX-485ADP.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Mitsubishi Electronics FX-485ADP, service manual, brief instructions and user manuals Mitsubishi Electronics FX-485ADP. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Mitsubishi Electronics FX-485ADP.

A complete manual for the device Mitsubishi Electronics FX-485ADP, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Mitsubishi Electronics FX-485ADP by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Mitsubishi Electronics FX-485ADP.

A complete Mitsubishi Electronics manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Mitsubishi Electronics FX-485ADP - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Mitsubishi Electronics FX-485ADP, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Mitsubishi Electronics FX-485ADP, that we can find in the current document
3. Tips how to use the basic functions of the device Mitsubishi Electronics FX-485ADP - which should help us in our first steps of using Mitsubishi Electronics FX-485ADP
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Mitsubishi Electronics FX-485ADP
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Mitsubishi Electronics FX-485ADP in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Mitsubishi Electronics FX-485ADP?

Use the form below

If you did not solve your problem by using a manual Mitsubishi Electronics FX-485ADP, ask a question using the form below. If a user had a similar problem with Mitsubishi Electronics FX-485ADP it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)