Manual Fluke 110

18 pages 0.45 mb
Download

Go to site of 18

Summary
  • Fluke 110 - page 1

    ® Models 110, 111 & 112 True RMS Multimeters Users Manual November 2000 (Englis h), Rev 1 7/01 © 2000-2001 Fluke Corporati on. All ri ghts reserved. Print ed in USA ...

  • Fluke 110 - page 2

    Limit ed War rant y and Limita tion of Lia bili ty Each Fluk e pro duct is w arrante d to be fr ee from defects in materi al and workmans hip un der nor mal use and servic e. Th e warran ty peri od is th ree year s and begins on the da te of ship ment. P arts, pro duct repai rs, and s ervices are warra nted f or 90 days. This wa rranty extends o nl ...

  • Fluke 110 - page 3

    i Table of Content s Titl e Page Read Befor e Using the Met er: War ni ngs and Prec aut ions .................................................... ii Con tacting F luke ............................................................................................................... .... 1 "Warn ing" an d "Cau tion" S tatemen ts.... ...

  • Fluke 110 - page 4

    Models 110, 1 11 & 112 Users M anual ii Read Before Using the Meter: Warnings and Precautions To avoi d possi ble electric shock or personal i njury, foll ow these guidelines : • Use the Meter only as specified in this manual o r the p rotection p rovided by the M eter migh t be i mpaired. • Do n ot use th e Mete r or test leads if they ap ...

  • Fluke 110 - page 5

    1 Models 110, 111 & 112 True RMS Mult i m et ers The Fluke Model 110 , Model 111 , and Model 112 are battery- powered, true-RMS multi m et ers (hereafte r " t he Meter") wi t h a 6000-count dis play and a bar graph. This manual applies t o all three models . All fi gures show the Model 112. The Meter meas ures or tests the followi ng: ...

  • Fluke 110 - page 6

    Models 110, 111 & 112 Users M anual 2 Battery Saver ("Sleep Mode") The Meter autom at ically ent ers "Sleep m ode" and blanks t he display i f the Meter is not used for 20 m i nut es. To dis abl e t he Sleep mode, hol d down t he Hz button whil e t urni ng t he Meter on. The Sleep mode is always dis abled in the MI N MAX AV ...

  • Fluke 110 - page 7

    True RMS Multimeters Displ ay 3 Display 8 7 7 6 4 5 3 2 1 13 14 15 9 10 11 12 aej02f.eps No. Symbol Meaning 1 s Meter is se t to contin uity function . 2 Diode test . 3 O Negative readi ngs . 4 Y Unsafe v ol t age. Voltage ≥ 30 V , or voltage ov erload conditi on (OL). 5 Display HOLD i s enabled. Dis pl ay freezes pres ent reading. In MIN M AX AV ...

  • Fluke 110 - page 8

    Models 110, 111 & 112 Users M anual 4 MIN MAX AVG Recording M ode The MIN MA X A VG recording m ode c apt ures the mi ni m um and maximum input values , and calc ul at es a running average of al l readings. When a new hi gh or l ow i s detected, t he Meter beeps. Put the M et er in the desired m eas urement func tion and range. ⇒ Press MIN MA ...

  • Fluke 110 - page 9

    True RMS Multimeters Manual Ranging and Auto Ranging 5 Manual Ranging and Auto Ranging The Meter has bot h Manual Range and Auto Range m odes . ⇒ In the Aut o Range mode, the Met er select s the range with t he best res ol ut i on. ⇒ In the Manual Range m ode, you override A ut o Range and select the range yoursel f . When you turn the M eter o ...

  • Fluke 110 - page 10

    Models 110, 111 & 112 Users M anual 6 Making Basic Measurements The figures on t he f ollowing pages s how how to make bas i c measurement s. When connect i ng t he t est leads t o the circ ui t or device, c onnect the comm on ( COM ) test lead bef ore connecti ng t he live lead; when removing t he t est leads , remove the li v e lead before re ...

  • Fluke 110 - page 11

    True RMS Multimeters Making Basic Measurements 7 Measuring Resistance aej04f.eps Measuring Capacitance aej05f.eps Testing for Continuit y aej06f.eps Note The continui t y funct ion works bes t as a fas t , convenient method to c heck for opens and shorts . For m ax imum accurac y in making res istanc e m eas urements, use the Meter’ s resistance ...

  • Fluke 110 - page 12

    Models 110, 111 & 112 Users M anual 8 Testing Diodes Forward Bias Single Beep Reverse Bias Good Diode Good Diode Shorted and Bad Diode Open Bad Diode aej07f.eps Measuring AC or DC Current (Models 111 and 112) Warning To avoid personal injury or damage to the Meter: • Never attempt to make an i n-ci rcuit current measure- ment when the open-ci ...

  • Fluke 110 - page 13

    True RMS Multimeters Using the Bar Graph 9 Measuring Frequency Warning To avoid electrical shock, di sregard the bar graph for frequencies > 500 Hz. I f the frequency of the m easured signal is > 500 Hz, the bar graph is unspecified. The Meter meas ures the frequency of a signal by counting t he number of ti m es the signal c rosses a t rigge ...

  • Fluke 110 - page 14

    Models 110, 111 & 112 Users M anual 10 Testing the Fuse (Models 111 and 112) Warning To avoid electrical shock or injury, rem o ve the test leads and any input signals before replacing the fuse. Test fus e as shown below. Ω <.5 OK OK aej12f.eps Replacing the Battery and Fuse Warning To avoid shock , injury, or damage t o the Met er: • Re ...

  • Fluke 110 - page 15

    True RMS Multimeters Specifications 11 Specifications Accuracy is s pec if ied f or 1 y ear af t er c alibrat ion, at operat ing t emperatures of 18 ° C to 28 ° C, with relative humidity at 0 % t o 95 %. The accuracy spec if ic at ions t ak e t he f orm of: ± ( [ % of Reading ] + [ Counts ] ) Maximum voltage between any termi nal and earth groun ...

  • Fluke 110 - page 16

    Models 110, 111 & 112 Users M anual 12 Accuracy ± ( [ % of Reading ] + [ Counts ] ) Function Range Resolut i on Model 11 0 Mode l 111 Model 11 2 AC Volts 1,2 -- True RMS (50 Hz to 500 Hz) 6000 mV 3 6.000 V 60.00 V 600.0 V 1 mV 0.001 V 0.01 V 0.1 V 1.0 % + 3 1.0 % + 3 1.0 % + 3 DC Volts 6000 mV 3 6.000 V 60.00 V 600.0 V 1 mV 0.001 V 0.01 V 0.1 ...

  • Fluke 110 - page 17

    True RMS Multimeters Specifications 13 Accuracy ± ( [ % of Reading ] + [ Counts ] ) Function Range Resolut i on Model 11 0 Mode l 111 Model 11 2 DC Amps (Models 111 and 112) 6.000 A 10.00 A continuous or 20 A overload for 30 seconds maximum 0.001 A 0.01 A NA 1.0 % + 3 1.0 % + 3 Hz 6 (V or A input ) 99. 99 Hz 999.9 Hz 9.999 kHz 50.00 kHz 0.01 Hz 0. ...

  • Fluke 110 - page 18

    Models 110, 111 & 112 Users M anual 14 ...

Manufacturer Fluke Category Video Game Keyboard

Documents that we receive from a manufacturer of a Fluke 110 can be divided into several groups. They are, among others:
- Fluke technical drawings
- 110 manuals
- Fluke product data sheets
- information booklets
- or energy labels Fluke 110
All of them are important, but the most important information from the point of view of use of the device are in the user manual Fluke 110.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Fluke 110, service manual, brief instructions and user manuals Fluke 110. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Fluke 110.

Similar manuals

A complete manual for the device Fluke 110, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Fluke 110 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Fluke 110.

A complete Fluke manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Fluke 110 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Fluke 110, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Fluke 110, that we can find in the current document
3. Tips how to use the basic functions of the device Fluke 110 - which should help us in our first steps of using Fluke 110
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Fluke 110
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Fluke 110 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Fluke 110?

Use the form below

If you did not solve your problem by using a manual Fluke 110, ask a question using the form below. If a user had a similar problem with Fluke 110 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)