  • First Alert WX-67 - page 1

    MODEL WX-67 — User’ s Manual Specific Area Message Encoding (S.A.M.E.) Emergency Alert System IMPORT ANT! PLEASE READ ALL INSTRUCTIONS CAREFULL Y BEFORE USING THE UNIT . WX-67 Large Manual 3/12/02 10:25 AM Page 1 ...

  • First Alert WX-67 - page 2

    T ABLE OF CONTENTS IMPORT ANT SAFEGUARDS . . . . . . . . . . . . .1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . .2 CHOOSING A LOCA TION . . . . . . . . . . . . . . .3 INST ALLA TION . . . . . . . . . . . . . . . . . . . . . .4 LOCA TION OF CONTROLS . . . . . . . . . . . . . .6 OPERA TION . . . . . . . . . . . . . . . . . . . . . . . .7 NOT ...

  • First Alert WX-67 - page 3

    Important Safeguards When using electrical appliances, basic safety precautions should always be followed, including the following: DANGER! The Manufacturer does not r epresent this unit to be water- proof. T o reduce the risk of fire, electrical shock, or damage to the unit, do not expose this unit to rain or moisture. DANGER! This product has the ...

  • First Alert WX-67 - page 4

    Introduction Congratulations on your purchase of the First Alert ® Specific Ar ea Message Encode (S.A.M.E.) Emer gency Alert Radio – WX67. This product is designed to exacting standar ds, which provide r eliabili- ty , long life and outstanding performance. This product embraces the advanced technology to r eceive digi- tally encoded weather , e ...

  • First Alert WX-67 - page 5

    Display Backlight: Allows you to read the LCD display in low light situations. When powered fr om an AC adapter or 12V DC source, the backlight will stay on continuously . During a power failure, to r eserve power fr om backup battery , the backlight will stay on for about 10 seconds every time you press a key . Remote Alert Capability: Allows you ...

  • First Alert WX-67 - page 6

    Installation Installing/r eplacing the receiver batter y The Emergency Alert Radio can use either a 9 volt alkaline or a Nickel Cadmium (Ni-Cd) rechar geable battery as its backup power sour ce. Use the slide switch at the back of the unit to select the type of battery installed. Select “Non-rechar geable” (NB) when an alkaline battery is insta ...

  • First Alert WX-67 - page 7

    Connecting the power USING ST ANDARD 120V AC OUTLET Plug the AC adapter cord into the 12V DC input jack on the back of the unit. Then plug the adapter into the wall outlet. Once plugged in, the internal battery charger will automatically char ge the battery if a r echar geable battery is installed, and the “Rechar geable” (RB) setting is select ...

  • First Alert WX-67 - page 8

    1. Battery Selection Switch 2. DC Power Jack 3. Remote Alert Jack 4. Alert Audio Out Jack 5. External Antenna Jack/Connector 6. Integrated T elescopic Antenna 7. YELLOW Color Indicator (W atch) 8. RED Color Indicator (W arning) 9. GREEN Color Indicator (Statement) 10. ALERT ON/OFF Switch 11. Function Knob 12. Liquid Crystal Display (LCD) 13. Emer g ...

  • First Alert WX-67 - page 9

    Operation 1. Battery Selection Switch – Select “Non-rechar geable” (NB) or “Rechar geable” (RB) for power backup. 2. DC Power Jack – Connect AC Adapter or 12V DC from car cigar ette adapter (not included). 3. Remote Alert Jack – T wo-wire terminal block pr ovides contact closure to activate external devices. 4. Alert Audio Out Jack ? ...

  • First Alert WX-67 - page 10

    PROGRAMMING THE RADIO After the radio is properly installed and power ed up, you can: • Select Correct Channel • Select Location Code • Select V oice or T one Alert Mode • Set the digital clock • Select Single or Multiple FIPS location codes, and enter the codes • Press “PROGRAM” button to switch the unit into pr ogram mode. By pres ...

  • First Alert WX-67 - page 11

    9 Alert Description T able: The table below shows what the LCD readout displays on your WX-67 Emer gency Alert Radio when r eceiving weather emer gency signals from NOAA. In addition, depending on your prior selection, an alert tone will sound and/or a voice broadcast will be hear d fr om the radio. W eather/Alert Code WX-67 Display Broadcast Will ...

  • First Alert WX-67 - page 12

    TO REVIEW THE OVERLAPPING ALERT MESSAGES: The Emergency Alert Radio can stor e up to 10 alert messages in its memory in a First in First Out (FIFO) basis. If the radio receives a new alert message when the memory is full and the previous alerts are still in ef fect, it will delete the oldest alert, then save, display and sound the new incoming aler ...

  • First Alert WX-67 - page 13

    E) SETTING the CLOCK- - Press “ENTER” button while “SETTING CLOCK” is displayed in the program mode. - Press “>”, “<” to point to either “hour” or “minute” digits and use the “Function (Scroll) Knob” to change the values. Press “ENTER” to accept changes. - Press the r ed “STOP ALERT TONE” button to return t ...

  • First Alert WX-67 - page 14

    WX 67 Specifications FREQUENCY COVERAGE – WEA THER CHANNELS Channel 1............................... 162.400 MHz Channel 2............................... 162.425 MHz Channel 3............................... 162.450 MHz Channel 4............................... 162.475 MHz Channel 5............................... 162.500 MHz Channel 6.............. ...

  • First Alert WX-67 - page 15

    NOTES WX-67 Large Manual 3/12/02 10:25 AM Page 15 ...

  • First Alert WX-67 - page 16

    90-Day Limited W arranty Sima Products Corp. (“Company”) warrants that if the accompanying product pr oves to be defective to the original purchaser in material or workmanship within 90 days fr om the original retail pur chase, the Company will, at the Company’ s option, either repair or r eplace same without char ge (but no cash refund will ...

Manufacturer First Alert Category Medical Alarms

Documents that we receive from a manufacturer of a First Alert WX-67 can be divided into several groups. They are, among others:
- First Alert technical drawings
- WX-67 manuals
- First Alert product data sheets
- information booklets
- or energy labels First Alert WX-67
All of them are important, but the most important information from the point of view of use of the device are in the user manual First Alert WX-67.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals First Alert WX-67, service manual, brief instructions and user manuals First Alert WX-67. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product First Alert WX-67.

A complete manual for the device First Alert WX-67, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use First Alert WX-67 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of First Alert WX-67.

A complete First Alert manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual First Alert WX-67 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the First Alert WX-67, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the First Alert WX-67, that we can find in the current document
3. Tips how to use the basic functions of the device First Alert WX-67 - which should help us in our first steps of using First Alert WX-67
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with First Alert WX-67
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of First Alert WX-67 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning First Alert WX-67?

Use the form below

If you did not solve your problem by using a manual First Alert WX-67, ask a question using the form below. If a user had a similar problem with First Alert WX-67 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)