Manual Barco DP100

22 pages 2.28 mb
Download

Go to site of 22

Summary
  • Barco DP100 - page 1

    Co oling liquid r efur bishme nt Installation manual For XLM, DP90 and DP100 R59770032/01 07/12/2006 ...

  • Barco DP100 - page 2

    Barco nv Eve nts Noordl aan 5, B-8520 Kuurne Phone: +32 56.36.89.70 Fax: +32 56.36.88.24 E-mail: sales.events@barco.com Visit us at the web: www.barco.com P r i n t e di nB e l g i u m ...

  • Barco DP100 - page 3

    1. Liquid C ooling Circ uit 1. LIQUID COOLING CIRCUIT Overview • Safety • Introduction • Diagnostics 1.1 Safety W ARNING : Hazardous pr oduct: Blue a ntifree ze dilu ted 1,2 et hanedio l (1/3 eth anediol – 2/3 Demi water). Not for household use. Keep out of reach of children. Harmful by oral intake. A void exposure to pregnant women. A void ...

  • Barco DP100 - page 4

    1. Liqui d Cooling Ci rcuit Parts of the liquid cooling circui t A B C H G F I K J D E Image 1-1 A DMD - Peltier cooling block. B Manometer . C Pressure vessel. D Outlet cooling circuit E Inlet cooling circuit F V ane GP u m p . H Cooling block light pipe entrance. I Flow switch. J Heat exchanger . H Transparent tube for visual check. 2 R59770032 C ...

  • Barco DP100 - page 5

    1. Liquid C ooling Circ uit Block d iagram o f the coo ling circu it Engine Pump Vane Outlet Inlet Expansion Vat Manometer Heat Exchanger Light Pipe entry Pressure relief valve (3 Bar) Vane Outlet Inlet Waterflow Sensor to SMPS Control Image 1-2 Block diagr am cooling circuit Order info li quid cooling Order numbe r Description R395198K Complete li ...

  • Barco DP100 - page 6

    1. Liqui d Cooling Ci rcuit T o oh i g ha m b i e n tt e m p e r a t u r e An Error or warning message “Ambient temp high” is displayed on the local LCD pa nel or touch panel. See manual of the projector for accessing error messages. Possible cause Solution Ambient temperature of the projector is too high. Measure the ambient temperature nearby ...

  • Barco DP100 - page 7

    1. Liquid C ooling Circ uit Possible cause Solution Defect pump. When the projector is running, you don’t feel any vibrations when touching the pump Drain the liquid cooling circuit, replace the pump, fill and pressurize the liquid cooling circuit. T i p: It’ s not ne cessary to drain the cooling circuit of the light processor . Bypass this par ...

  • Barco DP100 - page 8

    1. Liqui d Cooling Ci rcuit 6 R59770032 COOLING LIQU ID REFURBISHMENT 07/12/2006 ...

  • Barco DP100 - page 9

    2. Servicing the liquid cooling circ uit 2. SER VICING T HE LIQUID COOLING CIRCUIT W ARNING : All procedures in this chapter may on ly be performed by “qualifie d service technicians” . Definition of “qualified service tech nicians” or ”qualif ied technicians”: Persons having appropriate technica l training and experience ne cessary to ...

  • Barco DP100 - page 10

    2. Servicing the liquid coo ling circuit 2.1 Preparation for cooling liquid replacement What has to be done 1. Switch off the projector . 2. Remove the lamp unit to access the cooling liquid in- and outlet. 3. If excluding the light processor is required w hile handling the co oling circuit procedures, disconnect the circuit at the flow switch (a). ...

  • Barco DP100 - page 11

    2. Servicing t he liquid coolin g circuit OUT Image 2-3 Drain complete circui t 2. Close the valve. 3. Fill the syringe with air . Press in the valve of the male fitting when extracting air . Image 2-4 4. Couple the air filled syringe to the inlet of the cooling circuit and force air into the circuit via the syringe. L iquid will be expelled from t ...

  • Barco DP100 - page 12

    2. Servicing the liquid coo ling circuit 2.3 Filling the liq uid cooling circu it This procedure can only be used to fill an e mpty (drained) coo ling circuit. Necessary t ools • 60 cm of plastic tube with male valved fitting. • 60 cm of plastic tube with fe male valved fitting. • Syringe connected with short tube with male valved fitting. ? ...

  • Barco DP100 - page 13

    2. Servicing t he liquid coolin g circuit ab c d e f M F Image 2-7 4. Couple the filled syringe to the inlet of the cooling circuit and press the cooling liquid inside the circuit. Caution: Position the empty bottle above the liquid circuit (on top of projector). OUT a b Image 2-8 Filling cooling liq uid circuit 5. Disconnect the syringe from the c ...

  • Barco DP100 - page 14

    2. Servicing the liquid coo ling circuit 2.4 Refreshing the liquid cooling circuit Over time the cool ing liquid may show d eterioration and hen ce less effective cooling ch aracteristics. T o m ain- tain sound cooling properties, we advise ANNUAL replac ement of the cooling liquid. Necessary t ools • 2 x 60 cm of plastic tube with male valved fi ...

  • Barco DP100 - page 15

    2. Servicing t he liquid coolin g circuit OUT IN Image 2- 10 Refresh cooling circ uit 5. Switch on the projector . After projector boot-up procedure, the in ternal pump will automatically start sucking-up the fresh liquid Note: Make sure that the end of the plastic tube remains immersed in the bottle with fresh cooling liquid. 6. Switch off the pro ...

  • Barco DP100 - page 16

    2. Servicing the liquid coo ling circuit b ac d M F F M Image 2-1 1 Caution: It’s important that there is no air i nside the tube. The pump is not self priming and hence i s only capable of sucking through small volumes of air. 3. Push the male valved fitting of the filled tube into the inlet of the cooling circuit. Make sure that the inlet of th ...

  • Barco DP100 - page 17

    2. Servicing t he liquid coolin g circuit 7. Uncouple the two plastic tubes. Note: Make sure that both ends of the plastic tubes in the bottle remains immersed until the plastic tubes are uncouple from the li quid c ooli ng cir cuit . Tip : Sometimes a little cooling liquid will be spilled. Wrap a small cloth around the valved fitting while uncoupl ...

  • Barco DP100 - page 18

    2. Servicing the liquid coo ling circuit ab c d e f M F Image 2- 13 2. Couple the syringe to the inlet of the cooling circuit and press t he cooling liquid inside the circuit until the manom eter indicates 1 bar pressure. Ensure that no air bubbles are injected into the circuit. Caution: Maximum 1 bar of pressure is allowed on the liquid cooling ci ...

  • Barco DP100 - page 19

    2. Servicing t he liquid coolin g circuit Check within 24 hours whether th e pressure has stabilized close to 1 bar . If not, search for leak age. 2.7 Calibrating the liquid cooling circuit T o check if the pressure vessel is correctly calibrated you m ay connect the syringe with the cooling c ircuit and measu re the a mount of liqui d that i s aut ...

  • Barco DP100 - page 20

    2. Servicing the liquid coo ling circuit ab c d e f M F Image 2- 16 3. Fill the pressure vessel with liquid as follows: a) Couple the syringe with the inlet of the cooling circuit. b) Increase the pressure by pushing in the piston of the syringe (maximum 1 bar indi cated on the m anometer). c) While pressing, expel air from the pressure vessel. d) ...

  • Barco DP100 - page 21

    2. Servicing t he liquid coolin g circuit 4. Now that the pressure vessel is liquid filled you have to increase the pressure to 1 bar by pushing in the piston of the syringe. Then immediately extract 75 ml back into the syringe by doing the following: a) T aking note of the liquid level already in the syringe, release the plunger . b) Now fill the ...

  • Barco DP100 - page 22

    2. Servicing the liquid coo ling circuit The air hose fitting of the air pump mu st be of the Shrader valve type (A) to match with the pressure vessel, so the Presta valve type (B) has to be removed. Futhermore, the pin (C) inside the Shrader valve has to be removed as well. A B A A B C C Check within 24 hours whether th e pressure has stabilized c ...

Manufacturer Barco Category Fan

Documents that we receive from a manufacturer of a Barco DP100 can be divided into several groups. They are, among others:
- Barco technical drawings
- DP100 manuals
- Barco product data sheets
- information booklets
- or energy labels Barco DP100
All of them are important, but the most important information from the point of view of use of the device are in the user manual Barco DP100.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Barco DP100, service manual, brief instructions and user manuals Barco DP100. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Barco DP100.

Similar manuals

A complete manual for the device Barco DP100, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Barco DP100 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Barco DP100.

A complete Barco manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Barco DP100 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Barco DP100, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Barco DP100, that we can find in the current document
3. Tips how to use the basic functions of the device Barco DP100 - which should help us in our first steps of using Barco DP100
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Barco DP100
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Barco DP100 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Barco DP100?

Use the form below

If you did not solve your problem by using a manual Barco DP100, ask a question using the form below. If a user had a similar problem with Barco DP100 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)