    4140 S.W . 28TH W A Y • FT . LAUDERDALE, FL 33312 TEL 954.584.4446 • F AX 954.584.5556 TOLL-FREE: (866) 584-5504 OWNER’S MANUAL THIS MANUAL CONT AINS IMPORT ANT INFORMATION REGARDING SAFETY , OPERA TION, MAINTENANCE AND STORAGE OF THIS PRODUCT . TO A VOID POSSIBLE INJURY OR PROPER TY DAMAGE, PLEASE READ THIS INSTRUCTION MANUAL CAREFULL Y BEFO ...

  • Vector VEC049C - page 2

    IMPORT ANT SAFETY INFORMA TION To ensure reliable ser vice, your power inverter must be installed and used properly . Please read the installation and operating instructions thoroughly prior to installation and use. Pay particular attention to the W ARNING and CAUTION statements in this manual. The CAUTION statements advise against certain conditio ...

  • Vector VEC049C - page 3

    CONTENTS 1.0 INTRODUCTION 1.0 Basic T our of Inver ter . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.1 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.2 Back Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.2 Maxx SST Safety Features . . . . . . . . . . . . . . . . . . . ...

  • Vector VEC049C - page 4

    1.0 INTRODUCTION Y our new V ector MAXX SST inver ter is one in a series of the most advanced DC to AC inverters available. With proper care and appropriate usage, it will provide years of dependable ser vice in your car , truck, RV or boat. The MAXX SST supplies continuous power and peak watts, in the form of three plug-in outlets ready to deliver ...

  • Vector VEC049C - page 5

    FIGURE 1 – FRONT P ANEL FIGURE 2 – BACK P ANEL 5 1 3 2 1 3 4 2 5 1) THREE NORTH AMERICAN ST ANDARD OUTLETS 2) GREEN LED SHOWS UNIT IS OPERA TING 3) RED LED SHOWS UNIT IS SHUT DOWN 4) ON/OFF SWITCH 4 1.2 MAXX SST SAFETY FEA TURES BUIL T -IN AUTOMA TIC SAFETY FEA TURES INCLUDE: •O verload and over-temperature shutdown activated if AC output exc ...

  • Vector VEC049C - page 6

    MAXX SST™ inverters are ideal for powering: • TV/VCR combinations • Refrigerator/freezers • Lights • Radio receivers/transceivers •H eavy duty power tools & chargers • Stereo systems • Small microwave ovens •H ousehold appliances • Computers and peripheral equipment •D ry and/or wet-and-dr y vacuums • Sump pumps, motors ...

  • Vector VEC049C - page 7

    2.0 INVERTER APPLICA TIONS Aside from issues of supplying power to higher wattage appliances, inverters must be supplied with a constant source of high current 12VDC from a bank of batteries. At full watt load, the DC input requirements are up to 15 amps at 12VDC. Read and comply with the following applications, and your inverter will give you year ...

  • Vector VEC049C - page 8

    3.0 THEOR Y OF OPERA TION MAXX SST™ inverters change 12VDC into 110/120V AC RMS, electrical power . This is accomplished in two steps. (See FIGURE 4 ). The first stage raises the 12VDC input to 145VDC. The advanced design of the DC-to-DC first stage uses high-frequency conversion techniques that replace bulky and heavy transformers found in older ...

  • Vector VEC049C - page 9

    NOTE: Because of wave-shape differences, using standard digital or analog voltmeters may not correctly read the inverter output voltage. Unless a true RMS voltmeter such as a "Fluke 87" , "Fluke 8060A" , "Beckman 4410" or "T riplet 4200" is used, the reading will be from 2 to 20 volts low . 4.0 OPERA TION NOT ...

  • Vector VEC049C - page 10

    APPLIANCE AMPS@ W A TTS@ 110/120V AC 110/120V AC COMPUTER AND MONITOR 4 440 PORT ABLE V ACUUM 4.6 506 8-CUP COFFEE MAKER 5.5 605 ELECTRIC TRIMMER 5.5 605 1/2" HAMMER-DRILL 5.5 605 RECIPROCA TING SA W 6 660 V ACUUM CLEANER 7.2 792 1-1/8" ROT ARY HAMMER 7.8 858 1/6 H.P . SUBMERSIBLE SUMP PUMP 8 880 COMP ACT MICROW A VE OVEN 8.5 935 10" ...

  • Vector VEC049C - page 11

    Inductive loads, such as TVs and stereos, require more current to operate than do resistive loads with the same wattage rating. Induction motors, as well as some TVs, may require two to six times their rated wattage to start up. Because the MAXX SST™ inverters have a peak watt power rating, many such appliances and tools may be safely operated. T ...

  • Vector VEC049C - page 12

    Figure 6 – Batter y Operating Time For example, as shown in FIGURE 6 , using a 400 amp hour batter y (batteries), if the average power usage will be 1000 watts, the operating time will be about 150 minutes. A larger capacity batter y will deliver more operating time between recharges. NOTE: The manufacturer recommends conser vative estimates when ...

  • Vector VEC049C - page 13

    5.0 INST ALLA TION MAXX SST™ inverters will provide you with various watts of continuous, electrical power (See Models Specification Chart Page 18) when powered by a 12VDC source such as is found in a vehicle or multiple batter y configuration as shown in FIGURE 7 . This manual does not describe all of the possible types of batter y , batter y ch ...

  • Vector VEC049C - page 14

    In all marine applications, DO NOT install the inverter below or near the waterline, and keep the inverter away from moisture and water . Use ONL Y non-corrosive marine fasteners and fittings for installation. Only con- nect the inverter’ s DC input to existing wiring (which must be approved for marine use) rated specified gauge, cable and length ...

  • Vector VEC049C - page 15

    5.4 QUICK OPERA TIONAL CHECKOUT OR EMERGENCY USE YOU WILL NEED: • One heavy-duty jumper cable set with specified A WD wire rating (See Page 18) • One fully-charged automobile batter y • A common, slip joint pliers for loosening and tightening terminal nuts TEST PROCEDURE: 1. Remove the plastic terminal covers and terminal nuts. 2. Identify th ...

  • Vector VEC049C - page 16

    PRELIMINARY INST ALLA TION NOTES: The inverter has four slots in its mounting bracket that allow the unit to be fastened against a bulkhead, floor , wall or other flat sur face. Ideally , the mounting surface should be cool to the touch. It is more electrically efficient to use longer AC wiring than DC wiring, so install the inverter as close as po ...

  • Vector VEC049C - page 17

    9. Crimp or clamp on a heavy-duty , batter y-connection terminal to the other end of the negative (–) and positive (+) cable. Connect the negative (–) bat- ter y terminal cable to the negative (–) batter y terminal connector . 10. Ensure the inverter power switch is in the off position ( see FIGURE 1 ). 11. Connect the ring terminal end of th ...

  • Vector VEC049C - page 18

    18 Maximum Continuous Power 1000 W atts 1200 W atts 1500 W atts 2000 W atts 2500 W att Surge Capacity (Peak Power) 2000 W atts 2400 W atts 3000 W atts 4000 W atts 5000 W atts No Load Current Draw (switch on) 0.6 amps 1.3 amps 1.3 amps 1.3 amps 1.8 amps Max. Efficiency Approximately 90% 90% 90% 90% 90% Input V oltage 10.5–15.5VDC 10.5–15.5VDC 10 ...

  • Vector VEC049C - page 19

    7.0 SER VICE & P ARTS For ser vice on the inverters, contact the T echnical Support Depar tment at: VECTOR MANUF ACTURING, L TD 4140 S.W . 28th W ay • Ft. Lauderdale, Florida 33312 T el. (954) 584-4446 • Fax (954) 584-5556 • T oll-free: (866) 584-5504 8.0 TROUBLESHOOTING 8.1 COMMON PROBLEMS: POWER TOOLS AND MICROW A VE OVENS WON’T ST AR ...

  • Vector VEC049C - page 20

    8.2 TROUBLESHOOTING GUIDE TROUBLE/ INDICA TION POSSIBLE CAUSE SUGGESTED REMEDY No AC output – DC input below Recharge or replace red LED lit 10 volts batter y No AC output – Excessive appliance Reduce load-wait for red LED lit load-thermal shutdown inverter to cool. T urn off Low batter y alarm Bad connection T ighten all DC sounds continuously ...

  • Vector VEC049C - page 21

    10. W ARRANTY VECTOR 2 YEAR LIMITED W ARRANTY PROGRAM This limited warranty program is the only one that applies to this product, and it sets forth all the responsibilities of V ector Manufacturing, Ltd., regarding this product. There is no other warranty other than those described herein. This V ector Manufacturing, Ltd. product is warranted, to t ...

Manufacturer Vector Category Dehumidifier

Documents that we receive from a manufacturer of a Vector VEC049C can be divided into several groups. They are, among others:
- Vector technical drawings
- VEC049C manuals
- Vector product data sheets
- information booklets
- or energy labels Vector VEC049C
All of them are important, but the most important information from the point of view of use of the device are in the user manual Vector VEC049C.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Vector VEC049C, service manual, brief instructions and user manuals Vector VEC049C. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Vector VEC049C.

A complete manual for the device Vector VEC049C, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Vector VEC049C by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Vector VEC049C.

A complete Vector manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Vector VEC049C - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Vector VEC049C, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Vector VEC049C, that we can find in the current document
3. Tips how to use the basic functions of the device Vector VEC049C - which should help us in our first steps of using Vector VEC049C
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Vector VEC049C