Manual Emerson 16C26S-010

16 pages 0.4 mb
Download

Go to site of 16

Summary
  • Emerson 16C26S-010 - page 1

    UST Universal Slim Twin Model Number 16C26S-010 OWNERS MANUAL • Installation • Operation • Basic UST Service Guide • T echnical Repair Guide • Repair Parts Part No. 37-6070A Replaces 846-2027 Rev B 0015 Electronic Air Cleaner Printed In U.S.A. UL Listed CSA Certified by White-Rodgers Please read and familiarize yourself with the contents ...

  • Emerson 16C26S-010 - page 2

    2 RULES FOR SAFE INST ALLA TION AND OPERA TION Please read instructions before installing and using the Electronic Air Cleaner. This will help you obtain the full benefit from the Electronic Air Cleaner you have selected. WARNING ! ELECTROCUTION HAZARD Shut off power at fuse panel before servicing. Failure to do so could result in serious personal ...

  • Emerson 16C26S-010 - page 3

    3 HOW THE AIR CLEANER WORKS Dirt particles flowing through the ducts (Figure 1) first enters the pre-filters (A) where large particles (hair, lint, etc.) are trapped. Smaller particles (smoke, dust, pollen, etc.) pass through these pre-filters and enter the ionizing section (B). Here each tiny particle receives a positive electrical charge. These c ...

  • Emerson 16C26S-010 - page 4

    4 PREINST ALLA TION facing the power door. Air flow direction must agree with arrow embossed on end of collecting cells. After installing the cell sections, install pre-filters in cabi- net tracks on the right. This will again place the pre-filters on the air entering side (on the same side as ionizing wires). LOCATING THE AIR FILTER Your electroni ...

  • Emerson 16C26S-010 - page 5

    5 TYPICAL MOUNTING POSITIONS BASEMENT FURNACE (LOWBOY) (Figure 6) Cleaner is mounted hori- zontally in return plenum, just above furnace. COUNTERFLOW FURNACE (Figure 7) Cleaner is mounted horizon- tally in return duct or plenum, just above furnace. HIGHBOY FURNACE (Figure 8) Side installation. Cleaner is mounted vertically, where return air enters ...

  • Emerson 16C26S-010 - page 6

    6 INST ALLA TION REMOVE OLD FILTER AND DISCARD (Figure 12) NOTE: This filter may be mounted in the furnace compart- ment. CLEAN BLOWER COMPARTMENT It is suggested that the furnace blower compartment, blower and blower housing be cleaned to ensure clean air circulation. INSTALLATION The following is a typical installation of the air cleaner on a “ ...

  • Emerson 16C26S-010 - page 7

    7 WIRING INSTRUCTIONS 7. With the cabinet installed, the air cleaner can now be wired to electrical input source. WARNING ! Installation of this unit must comply with local electric codes or other applicable codes. Review and understand local codes prior to in- stallation. Failure to do so could result in serious personal injury or death. 8. The ai ...

  • Emerson 16C26S-010 - page 8

    8 An alternate method for controlling the air cleaner operation is to install an F859-0381 Air Flow Switch/ Harness Kit (available separately) that switches power to the air cleaner when airflow is detected. NOTE: The air cleaner should not be operating un- less the furnace blower is on. 11. With the cabinet Installed, reinstall pre-filter(s) and c ...

  • Emerson 16C26S-010 - page 9

    9 3. Release the latch on top of power pack and pull the power pack straight away from cabinet at the top. Then lift pack out of ledge at bottom edge of cabinet. Set power pack aside. 4. Remove the cell(s) and pre-filter(s) from cabinet. Using a solution of warm water and low sudsing detergent, soak cell(s) and pre-filter(s) for 20 to 30 minutes. N ...

  • Emerson 16C26S-010 - page 10

    10 SERVICE INDICA TION SER VICE CHECKS ON/OFF switch “ON” Unit functioning Normally Blower ON Operating Light ON ON/OFF switch “ON” 1. Power is not being supplied to air cleaner . Blower ON A. Check fuse or circuit breaker . Operating Light OFF B. Ensure power pack is properly installed and latched. 2. Collecting cell shorted - T urn power ...

  • Emerson 16C26S-010 - page 11

    11 TECHNICAL REP AIR GUIDE All voltage measurements indicated can be made with a high voltage D.C. probe and a general purpose volt ohm meter. For example: Simpson 260 or equivalent. NOTE: All tests to be performed with the Ozone Reduc- tion Jumper intact. NOTE: When servicing the power pack components, all wiring must be routed to factory specific ...

  • Emerson 16C26S-010 - page 12

    12 POWER SUPPLY CHECKOUT PROCEDURE 1. Turn power switch to the “OFF” position and remove the power pack from cabinet. 2. Place power pack on a well insulated workbench. Connect meter negative (-) lead to the sheet metal chassis and the high voltage probe to high voltage contact on back cover of power pack. Connect AC power to power pack using a ...

  • Emerson 16C26S-010 - page 13

    13 NOTES ...

  • Emerson 16C26S-010 - page 14

    14 REP AIR P AR TS ...

  • Emerson 16C26S-010 - page 15

    15 ITEM NO. DESCRIPTION P ART NUMBER 16C28S-010 1 Cabinet N/A 2 Pre-Filter • F825-0337 3 Collecting Cell • F81 1-0321 4 Junction Box Cover F838-0072 5 * Screw #6 x 3/8 ------ 6 Connector , Female F818-0053 7 Power Pack Assembly F858-0921 8 Cell Handle F832-0039 9 Ionizing Wire F843-0500 10 Light F844-0131 1 1 Switch F876-0202 12 Power Pack, Cab ...

  • Emerson 16C26S-010 - page 16

    White-Rodgers Division, Emerson Electric Co. 9797 Reavis Road, St. Louis, MO 63 123-5398 314-577-1300 • FAX 314-577-1517 www.white-rodgers.com Controlling America’s Indoor Comfort NOTICE T O CONSUMERS White-Rodgers Electronic Air Cleaner Dear Consumer; White-Rodgers would like to thank you for purchasing a White-Rodgers Electronic Air Cleaner o ...

Manufacturer Emerson Category Air Cleaner

Documents that we receive from a manufacturer of a Emerson 16C26S-010 can be divided into several groups. They are, among others:
- Emerson technical drawings
- 16C26S-010 manuals
- Emerson product data sheets
- information booklets
- or energy labels Emerson 16C26S-010
All of them are important, but the most important information from the point of view of use of the device are in the user manual Emerson 16C26S-010.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Emerson 16C26S-010, service manual, brief instructions and user manuals Emerson 16C26S-010. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Emerson 16C26S-010.

Similar manuals

A complete manual for the device Emerson 16C26S-010, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Emerson 16C26S-010 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Emerson 16C26S-010.

A complete Emerson manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Emerson 16C26S-010 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Emerson 16C26S-010, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Emerson 16C26S-010, that we can find in the current document
3. Tips how to use the basic functions of the device Emerson 16C26S-010 - which should help us in our first steps of using Emerson 16C26S-010
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Emerson 16C26S-010
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Emerson 16C26S-010 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Emerson 16C26S-010?

Use the form below

If you did not solve your problem by using a manual Emerson 16C26S-010, ask a question using the form below. If a user had a similar problem with Emerson 16C26S-010 it is likely that he will want to share the way to solve it.

Copy the text from the picture