Manual Graco 312776F

99 pages 4.53 mb
Download

Go to site of 99

Summary
  • Graco 312776F - page 1

    Operat ion ProMix ® 2KS Plural Compon ent Proportioner 312776F EN Manual system for proportiona l mixing of plural component coatings . For professional use only. Approved for use in explosive at mospheres (e xcept t he EasyK ey). TI1250 4a Important Safety Instructions Read all warning s and ins tructio ns in thi s manu al. Save these instruc tio ...

  • Graco 312776F - page 2

    2 312776F Contents Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Equipment Approvals . . . . . . . . . . . . . . . . . . . . . . . 3 System Configuration and Pa rt Numbers . . . . . . . 4 Configur ator Key . . . . . . . . . . . . . . . . . . . . . . . . . 4 Standard Features . . . . . . . . . . . . . . . . . . . . . . . 5 ...

  • Graco 312776F - page 3

    Relate d Manual s 312776F 3 Related Ma nuals Component Manuals in English Equipment Approv als Equipm ent app rovals appear o n the fol lowin g labels which a re att ached to th e Fluid Statio n and Eas yKey ™ . See F IG . 1 on page 4 for label lo cation s. Manual Description 312775 ProMi x 2KS Manu al Syste m Inst allation 312777 ProMix 2KS Manu ...

  • Graco 312776F - page 4

    System Configu ration and Part Numb ers 4 312776F System Configura tion and Part Numbers Conf igurat or Key The configured part nu mber for your equipment is printed on the equipment ident ification labels. See F IG . 1 for location of the identification labels. The part number includes one digit from each of the following six categories, depending ...

  • Graco 312776F - page 5

    System Con figuration and Part Number s 312776F 5 Standard Featu res Hazardous Lo cation Approval Models u sing a G 3000, G3 000HR, or i ntrinsi cally safe Co riolis me ter for b oth A a nd B meter s are a pproved for installati on in a Hazardo us Location - Class I, D iv I, Group D, T3 or Zone I Group IIA T3. Maximum Working Pressure Maximum worki ...

  • Graco 312776F - page 6

    Acce ssori es 6 312776F Accessories NOTE : This is n ot a co mplete li st of ava ilable ac cesso - ries and kits . Refer to the Graco webs ite for more i nfor- mation abo ut acces sories a vailable fo r use wit h this product . Accessor y Gun Flus h Box Gun Inse rt Se lecti on 15V354 T hird Pu rge Val ve Kit 15V536 S olven t Flow Sw itch Kit 15V213 ...

  • Graco 312776F - page 7

    Warn ings 312776F 7 Warnings The foll owing war nings are for the setup, us e, ground ing, ma intena nce, and r epair o f this equ ipment . The ex clama- tion poin t sym bol alerts you to a general warning and the hazard sy mbols refer to p rocedur e-specif ic ris ks. Whe n these sy mbols a ppear in the bod y of th is ma nual, re fer back to thes e ...

  • Graco 312776F - page 8

    Warnings 8 312776F SKIN INJEC TION HAZARD High-pres sure flui d from gun, hose leaks, or ruptured com ponent s will pierce sk in. This may look like just a cut, bu t it is a s erious i njury th at can resu lt in a mputation . Get immediate surgical treatment. • Tighten all fluid con nections before o perating the equ ipment . • Do not point g u ...

  • Graco 312776F - page 9

    Importa nt Two-Compon ent Materi al Informa tion 312776F 9 Important Two-Compon ent Material Infor m ation Isocyanate Conditions Material Self-ignition Keep Compo nents A and B Separate Moisture Sensitivity o f Isocyanates Isocy anates ( ISO) are catalys ts used i n two c omponent coatin gs. ISO wi ll reac t with moist ure (such a s humidi ty) to f ...

  • Graco 312776F - page 10

    Glossary of Terms 10 312776F Glossary of Terms Advanced Web Interf ace (AW I) - T his allo ws re mote ProMix backup and r estore, c onfig uration, l oggin g, and software update options. Air Chop - the p rocess of mixi ng air a nd sol vent together during th e flush c ycle to help clean t he lin es and reduce so lvent usage . Air Chop Time - d urat ...

  • Graco 312776F - page 11

    Glossa ry of Terms 312776F 11 First Purge Sour ce - sourc e of the media use d in the first pu rge cycle. Us er sett able to ai r purge valve, s ol- vent pu rge valv e, or 3rd purge v alve Firs t Purg e Tim e - duratio n of the first pu rge cycl e. User settable from 0-9 99 secon ds. Flow Control Resolution - a set tabl e value t hat a llows the fl ...

  • Graco 312776F - page 12

    Glossary of Terms 12 312776F Overdose (A, B, C) Alar m - when either the resin (A), or catal yst (B), or reduce r (C) co mponen t dispens es too much mate rial an d the system canno t compens ate for the additi onal m aterial . Potlife Time - the amount of time bef ore a mate rial becomes unsprayab le. Potlife Volume - the amoun t of material th at ...

  • Graco 312776F - page 13

    Overview 312776F 13 Overview Usage The Graco ProMix 2KS is an electronic two- compone nt paint propo rtioner . It can blend most two- compone nt solv ent and water borne epo xy, po lyurethane , and ac id-ca talyzed paints. It is not for use with “quick -settin g” paints (those with a potl ife of les s than 15 minute s). • Can proport ion at r ...

  • Graco 312776F - page 14

    Overvi ew 14 312776F Flow Meters (M A, MB, MS) Three optiona l flow meters are avai lable from Gr aco: • G3000 is a gen eral purpo se gea r meter typically used in flow r anges of 7 5-380 0 cc/min. (0.02– 1.0 gal/min .), pr essure s up to 4000 p si (28 MP a, 276 ba r), and vis cosi- ties of 20 –3000 centip oise. T he K-fac tor is appr oximate ...

  • Graco 312776F - page 15

    Overview 312776F 15 F IG . 2. Manual System, shown with G3000 Meters, Color/Ca talyst Change, One Gun Flush Box, and Accessor y Solvent F low Met er TI12504 a EK BC ST ACV CCM MS MA MB FM GFB BCV FO PS ...

  • Graco 312776F - page 16

    Overvi ew 16 312776F Key: MA Comp onent A Me ter DVA Compone nt A Dose Valve RVA Component A S ampling V alve SVA Component A S hutoff Valve MB Comp onent B Me ter DVB Compone nt B Dose Valve RVB Component B S ampling V alve SVB Component B S hutoff Valve MS So lvent Meter (accessory) SPV Solvent Purge Valve APV Air Purge Va lve SM Static Mixer FI ...

  • Graco 312776F - page 17

    Booth Contro l 312776F 17 Booth Control Used by t he operato r for da ily p ainting fu nctions includ- ing: chan ging rec ipes, s ignalli ng job co mplete , read- ing/clea ring al arms, an d placin g the sys tem in St andby, Mix, or Purge m ode. It is typical ly mounte d inside the booth or near the p ainter. Table 2: Booth Control Key and Indicato ...

  • Graco 312776F - page 18

    EasyKey Dis play and Keypad 18 312776F EasyKey Display and Key pad Display Shows gr aphical and text i nformati on relat ed to setup and spray ope rations . Back ligh t will turn o ff after 10 minutes without any key pr ess. Pr ess any k ey to tur n back on. NOTE : Pressi ng a key to turn on the di splay ba ck lig ht will also p erform the functi o ...

  • Graco 312776F - page 19

    EasyKe y Disp lay an d Keyp ad 312776F 19 AC Power Switch Turns sy stem AC power on o r off. I/S Power Power c ircuit to Fl uid St ation. Audible Alarm Alerts the us er when an alarm occurs. Av ailable settin gs for selec ting whi ch alarms will ca use an audible alarm are exp lained in Configur e Screen 1 , page 2 9. Clear the audib le ala rm by p ...

  • Graco 312776F - page 20

    Run M ode Screens 20 312776F Run Mode Screens NOTE: See F IG . 9 f or a map o f the Run screen s. Detailed s creen descripti ons fo llow. Splash Screen At power up, the Graco log o and softwa re revisio n will display for appr oximate ly 5 secon ds, follo wed by the Status S creen ( see page 22). The Spla sh screen wil l also mome ntari ly displa y ...

  • Graco 312776F - page 21

    Run Mode Screens 312776F 21 F IG . 9. Ru n Scre ens Map TI127 83a Press the S etup key to enter Setup mode. ...

  • Graco 312776F - page 22

    Run M ode Screens 22 312776F Status Screen •U s e t h e U p or Down keys to scroll throu gh the Run sc reen s. • Press the Setup key to ent er the Setup s creens from the S tatus sc reen. • The other key s have no functio n in th is Status screen . Key to F IG . 10: Active Recipe: s hows the ac tive re cipe. NOTE: At power up the sy stem defa ...

  • Graco 312776F - page 23

    Run Mode Screens 312776F 23 Totals Screen This scre en show s the job totals, fi ll tot als, gra nd totals, and job nu mber. Us e the tab s to reset job totals (Jo b Complete), reset solvent total s (Rst Solvent), or go to Level Con trol Scre en , page 24. The job totals ge nerally refer t o materia l dispen sed while in Mix mode . Thi s is like ly ...

  • Graco 312776F - page 24

    Run M ode Screens 24 312776F Alarms Sc reens Two scree ns show the las t 10 alarms. Us e the Up or Down keys to scroll betwee n the two screen s. See Tab le 10 on pa ge 80 fo r a lis t of alarm codes. Level Control Screen This sc reen sho ws the c urren t volu me for each flui d. Adjust t he cur rent vo lumes on this screen, or use t he tab to go t ...

  • Graco 312776F - page 25

    Setup Mod e 312776F 25 Setup Mode Press the Setup key to ente r Setup m ode. NOTE: See F IG . 17 for a map o f the Se tup scr eens. Deta iled sc reen d e scri ptions fo llow. F IG . 17. S etup Screen s Map To acces s Advanced Setup Screens , pa ge 34 and Recipe Setup Scr eens , page 38. To ac cess System Configu ration Scree ns , page 28. TI1278 4a ...

  • Graco 312776F - page 26

    Setup Mo de 26 312776F Password Screen If a pass word has been acti vated (see Configure Scree n 1 , page 29), the P assword s creen will appea r. You must enter the pass word to access the Set Up Home Screen . Enter ing the wron g pass word retur ns the display to the Stat us Scr een . NOTE: If you forge t the pa ssword, you can reset the password ...

  • Graco 312776F - page 27

    Setup Mod e 312776F 27 Table 4: Component Software Vers ions Component Disp lay (may vary from examples shown) De scription EK (E asyKey) 3.01.0 01 EasyK ey softwa re ver sion. FP (Fl uid Plat e) 3.01.0 01 Fluid Plate software versio n. BC (Boo th Control ) -.- Booth Con trol not i nstalle d, not de tected, or not op erational. 1.XX Booth Con trol ...

  • Graco 312776F - page 28

    Setup Mo de 28 312776F System Configurati on Screens NOTE: See F IG . 21 fo r a map of th e System Configura- tion Screen s . Detail ed scr een desc riptions fo llow. NOTE: Each screen dis plays the current scr een numbe r and the t otal nu mber of s creens in the gr oup. F IG . 21. System Configuration and Option Scree ns Map TI12785 a ...

  • Graco 312776F - page 29

    Setup Mod e 312776F 29 Configure Screen 1 Language Defines th e languag e of the screen text. Sel ect Engl ish (default ), Spani sh, Frenc h, Germ an, Italian , Dutch, J ap- anese (Kanji), Korean, Chines e (Simp lified) , and Cu s- tom. NOTE : Refer to do cument 313 386 for instruct ions on using the Custom La nguage feature to modify th e screen s ...

  • Graco 312776F - page 30

    Setup Mo de 30 312776F Configure Screen 3 1K/2K/3K Set this value to indicate the syst em performanc e level designat ion. S electing a val ue othe r than the installe d system level will r esult in restr icte d functio nality . Run Mode NOTE : If an A utoke y is i nstall ed, ad dition al sele ction s of Semi-A utomatic and Au tomatic a re avai lab ...

  • Graco 312776F - page 31

    Setup Mod e 312776F 31 DD Setup Mode Selecti ng “DD ” in the Do se Si ze field make s the Dynamic Dosing s etup mo de field a ppear. S elect On to enable DD s etup mode , or Off t o disa ble. See p age 49 for further informa tion. Configure Screen 5 Speci al Outputs Use of S pecial O utput s on Manua l syste ms requ ires instal lation of a Disc ...

  • Graco 312776F - page 32

    Setup Mo de 32 312776F Option Screen s NOTE: See F IG . 21 on page 28 for a ma p of the Option Scree ns . Detai led scr een desc ription s foll ow. NOTE: Each scr een disp lays the cu rren t scree n num ber and the tota l numb er of scr eens in th e group. Option Screen 1 Flush Volume Check This fiel d only appears if Solv ent Monit or is s et to ? ...

  • Graco 312776F - page 33

    Setup Mod e 312776F 33 Option Screen 2 Auto Dump If the auto d ump fea ture is being u sed, set to “Solven t Push ” or “Mix Fill Push”. On ce the auto dum p is enabled, t he gun f lush box is enabl ed and the potlif e alarm is a ctive fo r 2 minut es, the sy stem wil l automati - cally flush or push out the old material base d on the sele c ...

  • Graco 312776F - page 34

    Setup Mo de 34 312776F Advanced Setup Screens NOTE: See F IG . 32 for a map of th e Advanced Setup Scree ns . Detai led scr een desc ription s foll ow. F IG . 32. Ad vanced S etup S creens M ap TI12786 a Adva nced S etup scr een s 2 , 3, 4, an d 5 appear dependin g on select io ns ma de in Op tio n screen s 1 and 2. ...

  • Graco 312776F - page 35

    Setup Mod e 312776F 35 NOTE: Each scr een disp lays the curren t scree n num ber and the tota l numb er of scr eens in th e group. Th e total number o f scree ns in a gr oup and th e fiel ds disp layed on each s creen m ay vary d epending o n sel ections made in th e System Config uration Screens an d Option Scre ens . Advanced Se tup Screen 1 Gun ...

  • Graco 312776F - page 36

    Setup Mo de 36 312776F Advanced Se tup Screen 3 This sc reen appe ars o nly if Fl ush an d Fill Inpu t is set to “Globa l” in Op tion Screen 1 , page 32. If Number of Guns is set to “2” in Configure Screen 4 , page 30 , a Gun 2 colum n will ap pear in t his s creen. Firs t Purg e Tim e Enter the fi rst purge time (0 to 999 se conds). Total ...

  • Graco 312776F - page 37

    Setup Mod e 312776F 37 Advanced Se tup Screen 5 This sc reen appe ars o nly if Fl ush and F ill Inpu t is set to “Globa l” in Op tion Screen 1 , page 32 a nd Spe cial Ou t- puts is set to 1, 2, 3, or 4 in Configure Screen 5 , page 31. The I/O board has four pr ogramma ble outputs . On-Purge Dela y time at t he st art of the purge cyc le be fore ...

  • Graco 312776F - page 38

    Setup Mo de 38 312776F Recipe Setup Screens NOTE: See F IG . 38 for a map of the Re cipe sc reens. D etailed s creen d escriptio ns follo w. F IG . 38: Re cipe Scr eens Map TI1278 7a Recipe 0 Screens Recipe screens 3, 4, 5, 6, and 7 appear depending on selections made in Option screens 1 and 2 ...

  • Graco 312776F - page 39

    Setup Mod e 312776F 39 NOTE: Each scr een disp lays the curren t scree n num ber and the tota l numb er of scr eens in th e group. Th e total number o f scree ns in a gr oup and th e fiel ds disp layed on each s creen m ay vary d epending o n sel ections made in th e System Config uration Screens an d Option Scre ens . Recipe Setup S creen 1 Ratio ...

  • Graco 312776F - page 40

    Setup Mo de 40 312776F Recipe Setup S creen 3 This sc reen appe ars o nly if Fl ush an d Fill Inpu t is set to “Rec ipe” in Option Screen 1 , page 32. First Purge Sour ce Select “Air,” “Solv ent,” or “3rd Flush Valv e” (av ailab le only if 3 rd Flu sh Valv e is set to “On” i n Configure Scree n 3 on pa ge 30). Chop Type Select ? ...

  • Graco 312776F - page 41

    Setup Mod e 312776F 41 Recipe Setup S creen 5 This screen a ppears onl y if K-factor Inp ut is se t to “Rec- ipe” in Option Screen 1 , page 32. K-factor A Meter Enter the k-fac tor (cc/pulse) for flow me ter A. This is the amount of m aterial that pass es through t he flow meter per puls e (elec trical pulse s ignal). K-factor B Meter Enter the ...

  • Graco 312776F - page 42

    Setup Mo de 42 312776F Recipe Setup S creen 7 This sc reen appe ars o nly if Fl ush an d Fill Inpu t is set to “Rec ipe ” in O ption Scr een 1 , page 32 and Special Out - puts is se t to 1, 2, 3, 4, or “3 + GFB on #4” in Configure Scree n 5 , page 31. The I/ O board has fo ur program ma- ble output s. NOTE: If the Spe cial Ou tputs is set t ...

  • Graco 312776F - page 43

    Setup Mod e 312776F 43 Recipe 0 Screens NOTE: See F IG . 38 on p age 38 for a m ap of the Re cipe 0 screens . Detai led screen desc ription s follow. Reci pe 0 is t ypica lly use d: • in multiple colo r systems to purge out mat erial l ines without loading a new c olor • at the end of a s hift to pr event ha rdening of cata- lyzed m aterial . N ...

  • Graco 312776F - page 44

    Setup Mo de 44 312776F Recipe 0 S c reen 3 This sc reen only appe ars if S olvent Mo nitor is set to “Met er” in Configure Screen 5 , page 31 a nd Flush V ol- ume Check i s set to “On” in Op tion Screen 1 , pa ge 3 2 or 3rd F lush Valve is set to “On” i n Configure Screen 3 on page 30. Minimum Flush Volume This fiel d only appears if Fl ...

  • Graco 312776F - page 45

    Setup Mod e 312776F 45 Calibration Screen Use this screen to calibra te a meter. Set to “A Meter,” “B Meter,” or “Solvent Meter” (available if Solvent Monitor in Configure Screen 5 , page 31, is set to “Meter”). • Start - start calibr ation • Abort - sto p cali brati on • Purge - purge sampl ing va lves af ter ca libr ation Se ...

  • Graco 312776F - page 46

    System Operat ion 46 312776F System Oper ation Operation Mo des Mix System mixes a nd dis pense s mate rial. Standby Stop s the s ystem. Purge Purges the sys tem, us ing air and so lvent. Sequential Dosi ng Components A and B dispe nse sequ entially in the ne c- essary v olumes t o attain the mix ratio. Dynamic Dosing In typica l operati on (ratio ...

  • Graco 312776F - page 47

    System Operatio n 312776F 47 5. The com ponents a re pre-mi xed in th e integ rator, then un iformly bl ended in the stat ic mi xer (SM) . NOTE: To control output from the sta tic mixe r to the gun, inst all an option al fluid pressu re regul ator. 6. Components A and B are al ternatel y fed into the integrat or as lo ng as the g un is trigger ed. ...

  • Graco 312776F - page 48

    System Operat ion 48 312776F General Operating Cycle, Dynami c Dosing Over view Dynamic Dosing p rovides on -demand proportion ing, elimina ting the need for an integr ator and t herefore min- imizin g undes ired ma terial co ntact. T his feat ure is e spe- cially useful w ith sh ear-sens itive and waterbor ne materials . A rest ricto r inje cts co ...

  • Graco 312776F - page 49

    System Operatio n 312776F 49 Select a Component B Restrict or Size Install t he 15U95 5 Inje ction Ki t in the flu id man ifold as explain ed in the P roMix 2KS Insta llation m anual. Us e the char ts prov ided in th at manu al to sel ect an app ropri- ate rest rictor size ba sed on the desi red flow a nd mix ratio. Turn On Dynamic Dos ing 1. On th ...

  • Graco 312776F - page 50

    System Operat ion 50 312776F Balancing A/B Pressure If compone nt B press ure is too hi gh, it will p ush the com - ponent A s tream asi de durin g B injec tion. The v alve will not ope n long eno ugh, ca using a H igh Ratio a larm. If componen t B pressu re is too low , it will no t be injected in suffic ient volume. T he valv e will s tay open to ...

  • Graco 312776F - page 51

    System Operatio n 312776F 51 Mix Manifold Valve Setting s To open dose or p urge va lves, tur n hex nu t (E) coun ter- clockwi se . To close, t urn clockwi se. See Table 7 and F IG . 59. Table 6: Dynamic Dosing Troubleshooting Guide (for complete system tro ubleshooting, see Table 11 beginning on page 81) Warning /Alarm Messa ge Solution B Pres sur ...

  • Graco 312776F - page 52

    System Operat ion 52 312776F Air F low Swi tch ( AFS) Fu ncti on Air or Air-assis ted Guns The ai r flow s witch ( AFS) de tects ai r flow t o the gun an d signals the Pro Mix con troller whe n the gu n is trigge red. The AFS functions with the fl ow meters to ensure that system compo nents are funct ionin g correct ly. For examp le, if a flow mete ...

  • Graco 312776F - page 53

    System Operatio n 312776F 53 Start Up 1. Go thro ugh the Pr e-Operat ion Che cklist in Table 8 . 2. Turn the AC Pow er Switch ON (I = ON, 0 = OFF) .  Graco logo , softwa re revis ion, and “ Establi shing Comm unicatio n” wi ll dis play, followed by S tatus screen. See pa ge 20.  At power up the s ystem def aults to Re cipe 61, which i s n ...

  • Graco 312776F - page 54

    System Operat ion 54 312776F 6. Adjust com ponent A and B fluid suppl ies as needed for you r applicati on. Use l ow- est press ure po ssible . 7. D o not exce ed th e maxim um rate d work- ing pres sure show n on the system identi fication label or the lowes t rated c ompone nt in the s ystem. 8. Open the fluid suppl y valves to the syste m. 9. Ad ...

  • Graco 312776F - page 55

    System Operatio n 312776F 55 Shutdown Overnight Shutdown 1. Leave the power on. 2. Run Recip e 0 to purg e solvent th rough me ters and gun. Service Shutdown 1. Follow Pressur e Relief P rocedure on page 55. 2. Close ma in air s hutoff val ve on air supply line an d on ProMix . 3. Shut off P roMix 2KS po wer (0 positio n). F IG . 64 . 4. If serv ic ...

  • Graco 312776F - page 56

    System Operat ion 56 312776F Systems w ith Color Change and without Dump Valves NOTE: This proc edure re lieves pressu re throu gh the samp ling va lve. 1. Comple te all st eps under Single Co lor Sy stems , page 55. 2. Close the A si de shu toff va lve (S VA), F IG . 6 7. Open the A si de sam pling valve ( RVA). 3. Direct t he A side sampli ng tub ...

  • Graco 312776F - page 57

    System Operatio n 312776F 57 F IG . 65. Fluid Solenoids TI1265 2b GFB 1 GFB 2 Dump Valve A Purge Val ve B Solenoi d Purge Valve A Solenoid Dose Valve B Solenoid Dose Valve A Solenoid Optional Solenoid Locations 1 Dose A Dose B Purge B Dump A 3rd Purge Dump B GFB 2 GFB 1 Power Fiber Optic CAN CAN J1 J13 J12 J3 J9 J14 J15 J8 3rd Purge Va lve Solenoid ...

  • Graco 312776F - page 58

    System Operat ion 58 312776F F IG . 66: Color Change Solenoids TI1282 6a Soleno id Iden tificatio n Label Solen oid Iden tificat ion Label Solvent Sol enoid Override s Color Colo r Cataly st F IG . 67. Wall Mount Fluid Station Key: MA Compone nt A Met er DVA Componen t A Dose Valve RVA Componen t A Sampling Va lve SVA Component A Shutoff Val ve MB ...

  • Graco 312776F - page 59

    System Operatio n 312776F 59 Purging There ar e 4 purgi ng proce dures in th is ma nual: • Purgin g Mixed Material (below) • Purging Using Recipe 0 (page 60 ) • Purging F luid Supply Syst em (pag e 60) • Purging S ampling Valves a nd Tubes (page 62) Use the c riteria li sted in e ach pro cedure t o determi ne which proc edure to use. Purgin ...

  • Graco 312776F - page 60

    System Operat ion 60 312776F Purging Using Recipe 0 Reci pe 0 is t ypica lly use d: • in multiple colo r systems to purge out mat erial l ines without loading a new co lor • at the end of a s hift to pr event ha rdening o f cata- lyzed m aterial . To setup Rec ipe 0, go to Advan ced Se tup. Sele ct the Recipe ta b and chan ge the R ecipe to 0 . ...

  • Graco 312776F - page 61

    System Operatio n 312776F 61 3. Adjust t he solve nt fluid s upply pressur e. Use the lowest po ssib le pres sure to avoid splas hing. 4. R emove t he Flui d Stati on cover to ac cess the sol e- noid val ves. Se e F IG . 65. 5. Purge as follows : • Single co lor/sing le cataly st systems: Purge componen t A si de. Pres s the man ual ov erride on ...

  • Graco 312776F - page 62

    System Operat ion 62 312776F Purging Sampling V alves and Tubes Fol low th is pr oced ure af ter me ter cali brati on. 1. Press the Standb y ke y on th e Boot h Control. 2. See F IG . 67. Close both fluid shuto ff valves and samp ling va lves . 3. Route th e sampli ng tube s into a g rounded wa ste containe r. 4. On a single color sys tem, at tach ...

  • Graco 312776F - page 63

    System Operatio n 312776F 63 Solvent Push Fe ature The Solve nt Push fe ature ena bles the user to s ave some mix ed materia l by pus hing it ou t to the g un with solvent . The q uantity sa ved is 50% o f the potl ife vol ume entered i n Advanced Setup Screen 1 on page 35. If there ar e 2 guns, the sm aller po tlife vol ume i s used. Solvent Push ...

  • Graco 312776F - page 64

    System Operat ion 64 312776F Mix Fill Push Featu re The Mix F ill Push feature en ables the user to prevent potlife ex piration o f mater ial by mix ing and fl owing new material th rough the Gun F lush B ox. Mix Fi ll Push requ ires an access ory G un Flush B ox for each gun th at will us e this fea ture. Order Graco P art No. 15V826 F un Flush B ...

  • Graco 312776F - page 65

    Meter Ca libr ation 312776F 65 Meter Ca libration Calibrate t he meter: • The first tim e the syst em is o perated. • Wheneve r new mate rials a re used in the system, especia lly if the mate rials hav e visco sitie s that d iffer sign ifica ntly. • At least onc e per mo nth as par t of regu lar mai nte- nance . • Whenever a flow meter is s ...

  • Graco 312776F - page 66

    Meter Cal ibration 66 312776F 8. Dispens e compone nt A, B, or Solvent i nto beaker . a. To avoid s plashi ng, slowly o pen sa mpling valves . b. For mo re accu rate cal ibratio n, adju st the valve to dispen se at a f low rate s imilar to y our prod uc- tion spray fl ow rate. c. D ispen se a mi nimum of 250 cc ; make sure enough mate rial is dispe ...

  • Graco 312776F - page 67

    Color Change 312776F 67 Color Change Color Change Procedures Multiple Color Sy stems 1. Shut off ai r to the g un. 2. Place th e gun in the gun fl ush bo x if used , and clos e the lid. 3. Switch to Standb y mode at the Boo th Control . 4. Use the sc roll keys, or , to sele ct the new colo r. Pres s Enter to begin the color change seque nce. 5. If ...

  • Graco 312776F - page 68

    Color Ch ange 68 312776F Color Purge/Dump • This sequenc e flu shes out the color wi th solve nt, from the col or valve to the Du mp A valve . • The color chan ge solv ent valve an d the Dum p A valve o pen duri ng the P urge Time . • The color chan ge solv ent valve c loses wh en the Pur ge Time expi res. Color Fill • This sequenc e fills ...

  • Graco 312776F - page 69

    Color Change 312776F 69 NOTE : For manua l systems , the D igital I/O signals i den- tified in the color ch arts on the followi ng pages re present internal states. Table 9: Color Change Chart Refere nce Starti ng Recipe Ending Recipe Change Type Dump A Exiting Fill Refer to Fig. X Y Ch ange Ye s NA F IG . 71 X Y Change No NA F IG . 72 0Y F i l l Y ...

  • Graco 312776F - page 70

    Color Ch ange 70 312776F F IG . 71: P roMix 2K S Recipe Change Cha rt #1 X to Y Color/Catalyst/(Reducer) Purge from X, Fill from Y --> Stack V alves Solvent A If a component is not changing, that time segment is skipped Dump A Flush out old color and fill with new color Component A Solvent B Dump B Flush out old catalyst and fill with new cataly ...

  • Graco 312776F - page 71

    Color Change 312776F 71 F IG . 72: Pr oMix 2KS Recipe Change Chart #2 X to Y Color/Catalyst/(Reducer) Purge from X, Fill from Y --> Stack V alves Solvent A If a component is not changing, that time segment is skipped Dump A Flush out old color and fill with new color Component A Solvent B Dump B Flush out old catalyst and fill with new catalyst ...

  • Graco 312776F - page 72

    Color Ch ange 72 312776F F IG . 73: ProMix 2K S Recipe Fill Chart #3 0 to Y Color/Catalyst/(Reducer) No Purge, Fill from Y --> Stack V alves Solvent A Only active components are filled Dump A Push out solvent and fill with new color Component A Solvent B Dump B Push out solvent and fill with new catalyst Component B Separate Gun 1 and Gun 2 No P ...

  • Graco 312776F - page 73

    Color Change 312776F 73 F IG . 74: Pr oMix 2KS Rec ipe Fill Chart #4 0 to Y Color/Catalyst/(Reducer) No Purge, Fill from Y --> Stack V alves Solvent A Only active components are filled Dump A Push out solvent and fill with new color Component A Solvent B Dump B Push out solvent and fill with new catalyst Component B Separate Gun 1 and Gun 2 No P ...

  • Graco 312776F - page 74

    Color Ch ange 74 312776F F IG . 75: ProMix 2K S Recipe Fill Chart #5 0 to Y Color/Catalyst/(Reducer) No Purge, Fill from Y --> Stack V alves Solvent A Only active components are filled Dump A Push out solvent and fill with new color Component A Solvent B Dump B Push out solvent and fill with new catalyst Component B Separate Gun 1 and Gun 2 No P ...

  • Graco 312776F - page 75

    Color Change 312776F 75 F IG . 76: Pr oMix 2KS Rec ipe Fill Chart #6 0 to Y Color/Catalyst/(Reducer) No Purge, Fill from Y --> Stack V alves Solvent A Only active components are filled Dump A Push out solvent and fill with new color Component A Solvent B Dump B Push out solvent and fill with new catalyst Component B Separate Gun 1 and Gun 2 No P ...

  • Graco 312776F - page 76

    Color Ch ange 76 312776F F IG . 77: P roMix 2K S Recipe Purge Ch art #7 X to 0 Color/Catalyst/(Reducer) Purge from 0, No Fill --> Stack V alves Solvent A Every recipe 0 entry will flush all components Dump A Flush out old color Component A Solvent B Dump B Flush out old catalyst Component B Separate Gun 1 and Gun 2 Purge from 0 --> Purge V al ...

  • Graco 312776F - page 77

    Color Change 312776F 77 F IG . 78: Pr oMix 2KS Rec ipe Purge Chart #8 X to 0 Color/Catalyst/(Reducer) Purge from X, Fill from Y --> Stack V alves Solvent A Every recipe 0 entry will flush all components Dump A Flush out old color Component A Solvent B Dump B Flush out old catalyst Component B Separate Gun 1 and Gun 2 Purge from 0 --> Purge V ...

  • Graco 312776F - page 78

    Color Ch ange 78 312776F F IG . 79: P roMix 2K S Recipe Purge Ch art #9 0 to 0 Color/Catalyst/(Reducer) Purge from 0, No Fill --> Stack V alves Solvent A Every recipe 0 entry will flush all components Dump A Flush out old color Component A Solvent B Dump B Flush out old catalyst Component B Separate Gun 1 and Gun 2 Purge from 0 --> Purge V al ...

  • Graco 312776F - page 79

    Color Change 312776F 79 F IG . 80: ProMix 2KS Recip e Purge Cha rt #10 0 t o 0 Color/Catalyst/(Reducer) Purge from 0, No Fill --> Stack V alves Solvent A Every recipe 0 entry will flush all components Dump A Flush out old color Component A Solvent B Dump B Flush out old catalyst Component B Separate Gun 1 and Gun 2 Purge from 0 --> Purge V al ...

  • Graco 312776F - page 80

    Alarms and Warnings 80 312776F Alarms and Warnings NOTE: Do not use the fl uid in the line t hat was di s- pensed of f rati o as it ma y not cu re prope rly. System Alarms System alarms alert you of a proble m and h elp prev ent off-ratio s praying. If an ala rm occur s, opera tion stops and t he foll owing occu rs: • A red LED ill uminates stead ...

  • Graco 312776F - page 81

    Alarm Tro ubleshoo ting 312776F 81 Alarm Troubleshoot ing Table 11. Alarm Troubleshooting E-1: COMM ERROR Cause Solution No power to the EasyKey . Connect power to Eas yKey. No power to Flu id Statio n. The in trinsically s afe pow er cable be tween the EasyK ey and Fluid St ation is not c on- nected. Verify th at the c able is corre ctly co nnecte ...

  • Graco 312776F - page 82

    Alarm Tro ubleshoo ting 82 312776F E-3: RATIO HIGH ALARM Sequ ential Dosin g Sy stem The mix r atio is higher th an the set toleranc e on the pr evious dose cy cle. Dynamic Dosing System The mix r atio is higher th an the set toleranc e for an A to B compon ent volum e com parison . Cause Solution There is too little restr iction i n the system . ? ...

  • Graco 312776F - page 83

    Alarm Tro ubleshoo ting 312776F 83 E-4: RATIO LOW ALARM Sequ ential Dosin g Sy stem The mix r atio is lowe r than the set to lerance on the pr evious d ose cycl e. Dynamic Dosing System The mix ratio i s lower than the set to lerance for a n A to B c omponent v olume compa rison. Cause Solution There is too much restri ction in the sy stem. • Che ...

  • Graco 312776F - page 84

    Alarm Tro ubleshoo ting 84 312776F E-5: OVERDOSE A/B DOS E TOO SHORT ALARM and E-6: OVERDOSE B/A DOS E TOO SHORT ALARM E-5: the A dose ov ershoo ts and , when comb ined with B, is too large for the m ix chamb er capa city. E-6: the B dose oversh oots a nd forces an A si de dose tha t, when c ombin ed with B, is too large for the mix chamb er capaci ...

  • Graco 312776F - page 85

    Alarm Tro ubleshoo ting 312776F 85 E-7: DOSE TIME A ALARM and E-8: DOSE TIME B ALARM E-7: gun trigger input is active (AFS or Integrati on) and fe wer than 3 1 A me ter puls es were d etected du ring the dose time sele cted. E-8: gun trigger input is active (AFS or Integrati on) and fe wer than 3 1 B me ter puls es were d etected du ring the dose t ...

  • Graco 312776F - page 86

    Alarm Tro ubleshoo ting 86 312776F E-9: Not u sed E-10: REMOTE S TOP ALARM Cause Solution Automatio n has requ ested th at the system ab ort all ope r- ations. Abort o peration s. Troubl eshoo t automatio n system . E-11: PURGE VO LUM E ALAR M Cause Solution ProMix 2KS solv ent flow switch i s not ac tivated wh ile purging . Verify th at the g un i ...

  • Graco 312776F - page 87

    Alarm Tro ubleshoo ting 312776F 87 E-12: CAN COMM E RROR ALARM Cause Solution Communic ation b etween the C olor Change M odule and the Fluid S tation is inter rupted. • V erify tha t all cables are conne cted se curely and that the Color Chang e and Boot h Control power LED s turn on . If the power LED does not turn on, the pr ob- lem is pr obab ...

  • Graco 312776F - page 88

    Alarm Tro ubleshoo ting 88 312776F E-13: HIGH FLOW ALARM or E-14: LOW FLOW ALARM (may also be set as Warnings) Cause Solution Fluid sy stem is produci ng too m uch or t oo litt le flow . Troub lesh oot flui d system fo r rest rict ions, lea ks, exhaus ted flu id suppl y, incor rect setti ngs, et c. Increas e or de crease flow rate , as requ ired . ...

  • Graco 312776F - page 89

    Alarm Tro ubleshoo ting 312776F 89 E-19: I/O ALARM Cause Solution The Mix and Pur ge digital inputs are on at t he same time. E nsure th at only o ne inpu t is on at a time. At least 1 sec delay i s requi red when switc hing from Mix to P urge or vice ve rsa. NOTE: The I/O alarm inc orpora tes seve ral sub -alarm s relating to intern al data issues ...

  • Graco 312776F - page 90

    Alarm Tro ubleshoo ting 90 312776F E-20: PURGE INITIA TE ALARM Cause Solution System detects a tomizing air to th e gun when p urge is sele cted . Shut off g un air. For sys tems w ith a gun fl ush b ox, gun is not in th e box when purg e is selec ted. Place gun in gun flush box. Veri fy that gun flu sh box is operati ng properly. For sys tems w it ...

  • Graco 312776F - page 91

    Alarm Tro ubleshoo ting 312776F 91 E-25: AUTO DUMP COMP LETE ALARM Cause Solution A potlife ala rm is active for more than 2 minu tes, the gun flush bo x is enabled and gu n is in the gun flush b ox, and an auto dum p flus h sequen ce is c omplet e. Be sur e to spra y all m ixed mate rial bef ore potli fe expir es. E-26: COLOR/CATALYS T PURGE ALARM ...

  • Graco 312776F - page 92

    Schema tic Diagram s 92 312776F Schematic Diagrams System Pneumat ic Schematic 3/8 AIR FIL TER MANU AL DRAIN 5 MICRON W ALL MOUNT ONLY FLUSH AIR TO FL UID INLET 1/4 TUBE TO MANIFOLD 1/4 TUBE 4-W A Y SOLENOID 12 VDC PURGE A VA LV E DUMP A VA LV E (OPTIONAL) 4-W A Y SOLENOID 12 VDC 3-W A Y SOLENOID 12 VDC 3-W A Y SOLENOID 12 VDC MANIFOLD AIR EXHAUST ...

  • Graco 312776F - page 93

    Schema tic Dia grams 312776F 93 System Electrical Schem atic NOTE: The el ectrica l schem atic illus trate s all pos sible w iring expa nsion s in a P roMix 2 KS sys tem. So me co mpo- nents sh own are no t incl uded with all s ystems. Non-Hazardous Area BARRIER BOARD OPERA TOR INTERF ACE 1 2 L1 N 85-250 VAC GND N L1 85-250 V AC 1 2 3 J5 +12VDC I/S ...

  • Graco 312776F - page 94

    Schema tic Diagram s 94 312776F System Electrical Schema tic NOTE: The el ectrica l schem atic illus trate s all pos sible w iring expa nsion s in a P roMix 2 KS sys tem. So me co mpo- nents sh own ar e not in cluded wi th all s ystems. Hazardous Area HAZARDOUS AREA +12VDC I/S COM SHIELD J10 1 2 3 1 2 3 4 5 6 J3 PWR (RED) COM (BLACK) SIG (WHITE) SH ...

  • Graco 312776F - page 95

    Schema tic Dia grams 312776F 95 EasyKey Electrical Sche matic J9 4 3 2 1 GREEN/BLACK/WHITE 22 A WG RED/BLACK/WHITE 22 A WG BLACK 18 A WG RED 18 AWG - + ALARM - - + DC OK POWER SUPPL Y COMMON 24 VDC+ BARRIER BOARD J4-3 J4-2 J4-1 J1-5 J1-4 J1-3 J1-2 J1-1 TERMINAL BLOCKS POWER ROCKER SWITCH L L N N 24 VDC+ OUTPUT HIGH VOL TAGE IN J4 24 VDC+ IN J1 GND ...

  • Graco 312776F - page 96

    Meter Perf ormance Da ta (G3000 on A and B) 96 312776F Meter Perf ormance Data (G3000 on A and B) 0 500 1000 1500 2000 2500 3000 3500 3800 1:1 2:1 3:1 4:1 5:1 6:1 7:1 8:1 9:1 10:1 11:1 12:1 13:1 14:1 15:1 16:1 17:1 18:1 19:1 20:1 21:1 22:1 23:1 24:1 25:1 26:1 27:1 28:1 29:1 30:1 Ratio Flow Rate (cc/mi n) 50cc D ose 25cc Do se 10cc D ose NOTE: Maxi ...

  • Graco 312776F - page 97

    Meter Perform ance Data (G3000 on A, Coriolis on B) 312776F 97 Meter Performance Data (G 3000 on A, Coriolis on B) 0 500 1000 1500 2000 2500 3000 3500 3800 1:1 2:1 3:1 4:1 5:1 6:1 7:1 8:1 9:1 10:1 11:1 12:1 13:1 14:1 15:1 16:1 17:1 18:1 19:1 20:1 21:1 22:1 23:1 24:1 25:1 26:1 27:1 28:1 29:1 30:1 Ratio Flow Rate (cc/min) 50cc Do se 25cc D ose 10cc D ...

  • Graco 312776F - page 98

    Technic al Data 98 312776F Technical Da ta * Dep endent on pro gramm ed K-facto r and appli catio n. The maxi mum allowab le flow meter pulse freq uency is 425 Hz (pulses /sec) . For more detailed i nformati on on vis cosities, flow r ates, or m ixing rati os, cons ult your Graco di s- tributor. See indi vidua l compon ent man uals for additi onal ...

  • Graco 312776F - page 99

    All written and visual data contained in this document reflects the latest product information available at the time of publica tion. Graco rese rves the right t o make changes at any time without notice. Graco H eadquarte rs: Minnea polis International O ffices: Bel gium, Chin a, Japan, Korea GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNE ...

Manufacturer Graco Category Webcam

Documents that we receive from a manufacturer of a Graco 312776F can be divided into several groups. They are, among others:
- Graco technical drawings
- 312776F manuals
- Graco product data sheets
- information booklets
- or energy labels Graco 312776F
All of them are important, but the most important information from the point of view of use of the device are in the user manual Graco 312776F.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Graco 312776F, service manual, brief instructions and user manuals Graco 312776F. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Graco 312776F.

Similar manuals

A complete manual for the device Graco 312776F, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Graco 312776F by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Graco 312776F.

A complete Graco manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Graco 312776F - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Graco 312776F, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Graco 312776F, that we can find in the current document
3. Tips how to use the basic functions of the device Graco 312776F - which should help us in our first steps of using Graco 312776F
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Graco 312776F
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Graco 312776F in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Graco 312776F?

Use the form below

If you did not solve your problem by using a manual Graco 312776F, ask a question using the form below. If a user had a similar problem with Graco 312776F it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)