    PRODUCT DA T A ® U.S. Registered Trademark Copyright © 1997 Honeywell Inc. • All Rights Reserved D896 Automatic V ent Damper GENERAL D896 Automatic V ent Dampers are used with atmospheric type, gas-fired equipment to reduce home heating losses b y closing off the vent betw een heat cycles. FEA TURES • 4-wire plug receptac le. • Includes wir ...

  • Honeywell D896 - page 2

    D896 A UT OMA TIC VENT D AMPER 68-0186 2 ORDERING INFORMA TION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distr ibutor , ref er to the TRADELINE® Catalog or price sheets for complete ordering number . If you ha ve additional questions, need further information, or would like to comment on our product ...

  • Honeywell D896 - page 3

    D896 A UT OMA TIC VENT D AMPER 68-0186 3 NO TE: A minimum of a 30 V A transf or mer must be used when D896 is installed with S86/S8600/S8610/ S8620. Electrical Connections: F our-wire plug receptacle. Thermostat Anticipator Setting: 0.13A. Operating Times: Appro ximate Damper Opening Time: 30 seconds. Appro ximate Damper Closing Time: 30 seconds. T ...

  • Honeywell D896 - page 4

    D896 A UT OMA TIC VENT D AMPER 68-0186 4 IMPORT ANT 1. The atmospheric draft hood outlet area must be smaller or equal to the inlet area of the damper assembly . 2. If a second gas valv e needs to be installed, refer to the gas valv e manufacturer instructions f or the procedure. 3. Using a dual automatic valv e combination gas control or two separ ...

  • Honeywell D896 - page 5

    D896 A UT OMA TIC VENT D AMPER 68-0186 5 Fig. 3. Installing D896 V ent Damper . IMPORT ANT Ne ver mount the vent damper with the motor actuator abov e or below the vent. Do not install the damper blade plug if the v ent damper is installed on a system with a continuous or standing pilot. The hole provides the minimum v ent area required by code f o ...

  • Honeywell D896 - page 6

    D896 A UT OMA TIC VENT D AMPER 68-0186 6 Fig. 5. D896 with co ver off. Honeywell D892/D896 Wires Honeywell D80B Wires Johnson Q35 Wires EFFIKAL RVG Wires Yellow Orange Green 1 Orange Blue and Red White 2 Blue Black Red 3 Black Yellow Black 4 NORM SERV SERVICE SWITCH HARNESS CABLE CONNECTOR IGNITION GAS PWR LED CALL FOR HEA T LED S3 SWITCH RELA Y 1K ...

  • Honeywell D896 - page 7

    D896 A UT OMA TIC VENT D AMPER 68-0186 7 MV MV/PV PV GND (BURNER) 24V GND 24V SPARK S8600F, H, M; S8610F,H POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. REMOVE PLUG ONLY IF USING VENT DAMPER. FUSE BLOWS ON STARTUP WHEN PLUG IS REMOVED; THEN MODULE OPERATES ONLY WHEN VENT DAMPER IS CONNECTED. 1 1 M11375 SENSE TH-W VENT ...

  • Honeywell D896 - page 8

    D896 A UT OMA TIC VENT D AMPER 68-0186 8 Fig. 10. Snap-Tite™ Bo x Connector release. Checkout Heating 1. Tu rn on the po wer supply . 2. If using a thermostat, set the heat anticipator at 0.13A. 3. Set the thermostat or controller to 10 ° F (6 ° C) above the room temperature to call f or heat. 4. Check that the D896 CALL FOR HEA T and IGNITION ...

  • Honeywell D896 - page 9

    D896 A UT OMA TIC VENT D AMPER 68-0186 9 Thermostat Setting Symptom Possible Cause Action Set thermostat 10°F above room temperature to call for heat. No response from D896. Incorrect wiring or blown fuse. • Check the circuit breaker or fuse and, if necessary, reset or replace. • Check the transformer and limit control. • Check for 24 Vac ac ...

  • Honeywell D896 - page 10

    D896 A UT OMA TIC VENT D AMPER 68-0186 10 ANSI ST ANDARDS EXHIBIT A Procedure For Saf ety Inspection of an Existing Appliance Installation The f ollowing procedure is intended as a guide to aid in determining that an appliance is proper ly installed and is in a safe condition f or continuing use. This procedure is predicated on central furnace, boi ...

  • Honeywell D896 - page 11

    D896 A UT OMA TIC VENT D AMPER 68-0186 11 EXHIBIT B Procedure f or Installing Electrically Operated Automatic Vent Damper De vices on Existing Appliances This procedure is intended as a guide to aid in safely installing an electrically operated or mechanically actuated automatic vent damper de vice on an existing appliance . This procedure is based ...

  • Honeywell D896 - page 12

    D896 A UT OMA TIC VENT D AMPER 68-0186 12 Honeywell Europe S.A. 3 Avenue du Bourget B-1140 Brussels Belgium Honeywell Asia Pacific Inc. Room 3213-3225 Sun Hung Kai Centre No. 30 Harbour Road Wanchai Hong Kong Home and Building Control Honeywell Limited-Honeywell Limitée 155 Gordon Baker Road North York, Ontario M2H 2C9 Honeywell Latin American Div ...

Manufacturer Honeywell Category Ventilation Hood

Documents that we receive from a manufacturer of a Honeywell D896 can be divided into several groups. They are, among others:
- Honeywell technical drawings
- D896 manuals
- Honeywell product data sheets
- information booklets
- or energy labels Honeywell D896
All of them are important, but the most important information from the point of view of use of the device are in the user manual Honeywell D896.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Honeywell D896, service manual, brief instructions and user manuals Honeywell D896. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Honeywell D896.

Similar manuals

A complete manual for the device Honeywell D896, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Honeywell D896 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Honeywell D896.

A complete Honeywell manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Honeywell D896 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Honeywell D896, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Honeywell D896, that we can find in the current document
3. Tips how to use the basic functions of the device Honeywell D896 - which should help us in our first steps of using Honeywell D896
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Honeywell D896
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Honeywell D896 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Honeywell D896?

Use the form below

If you did not solve your problem by using a manual Honeywell D896, ask a question using the form below. If a user had a similar problem with Honeywell D896 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)