Manual Jet Tools J150ECA

24 pages 0.32 mb
Download

Go to site of 24

Summary
  • Jet Tools J150ECA - page 1

    PORT ABLE FORCED AIR HEA TERS OWNER’S MANUAL J100ECA 100,000 BTU/Hr 100 SIDE PV 002 J150ECA 150,000 BTU/Hr 150 SIDE PV 004 IMPORTANT Read and understand this manual before assembling, starting or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference. ...

  • Jet Tools J150ECA - page 2

    2 Safety Information ......................................................................... 3 Product Identification .................................................................... 4 Unpacking ...................................................................................... 5 Assembly .................................................. ...

  • Jet Tools J150ECA - page 3

    3 SAFETY INFORMA TION ! W ARNINGS IMPORTANT: Read this Owner’s Manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning. • Use only kerosene or No. 1 fuel oil to avoid ris ...

  • Jet Tools J150ECA - page 4

    4 PRODUCT IDENTIFICA TION Lower Shell Hot Air Outlet Figure 1 - 100,000 BTU/Hr Model Fuel Cap Side Cover Power Cord Fuel Tank Fan Guard Upper Shell Fuel Cap Fan Guard Figure 2 - 150,000 BTU/Hr Model Hot Air Outlet Lower Shell Power Cord Air Filter End Cover Upper Shell Fuel Tank ...

  • Jet Tools J150ECA - page 5

    5 UNP ACKING 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check items for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater. ASSEMBL Y These models are furnished with wheels and handles. Wheels, handles, and the mounting hardware are found in the shipping car ...

  • Jet Tools J150ECA - page 6

    6 THEOR Y OF OPERA TION The Fuel System: The air pump forces air through the air line. The air is then pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fi ne mist of fuel is sprayed into the combustion chamber. The Air System: The motor turns the fan. The fan pushes air into and around the combustion chamber. Th ...

  • Jet Tools J150ECA - page 7

    7 VENTILA TION OPERA TION ! W ARNING Follow the minimum fresh, outside air ventilation require- ments. If proper fresh, outside air ventilation is not provided, carbon monoxide poisoning can occur. Provide proper fresh, outside air ventilation before running heater. Provide a fresh air opening of at least three square feet (2800 square cm) for each ...

  • Jet Tools J150ECA - page 8

    8 ST ORAGE 1. Drain fuel tank. Note: Locate drain plug on underside of fuel tank. Remove drain plug to drain all fuel. Be sure all fuel is removed. 2. Replace drain plug. 3. Add one gallon (4 liters) of clean kerosene to fuel tank. 4. Attach fuel cap. 5. Move heater forwards and backwards to stir fuel. 6. Remove drain plug and drain fuel tank. Be s ...

  • Jet Tools J150ECA - page 9

    9 TROUBLE- SHOOTING ! W ARNING Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur. Heater burns, but creates puffs of smoke. Heater will not burn steady. Heater burns with odor. Heater smokes continuously. OBSERVED FAULT POSSIBLE CAUSE REMEDY A) Water in fuel B) Wrong fuel Wrong pump pressure ...

  • Jet Tools J150ECA - page 10

    10 150 SHELL REMOVAL EA/EB Euro PFA/P 054 SER VICE PROCEDURES ! W ARNING Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur. Upper Shell Removal 1. Remove screws along each side of heater using 5/16" nut-driver. These screws attach upper and lower shells together. 2. Lift upper shell off ...

  • Jet Tools J150ECA - page 11

    11 Fuel Filter (100,000 BTU/Hr Model) 1. Remove side cover screws using 5/16" nut-driver. 2. Remove side cover. 3. Pull upper fuel line off fuel fi lter neck. 4. Carefully pry bushing, lower fuel line, and fuel fi lter out of fuel tank. 5. Wash fuel fi lter with clean fuel and replace in tank. 6. Attach upper fuel line to fuel fi lter neck ...

  • Jet Tools J150ECA - page 12

    12 Spark Plug 1. Remove upper shell (see page 10). 2. Remove fan (see page 17). 3. Remove spark plug wire from spark plug. 4. Remove spark plug from burner head using 13/16" open-end wrench. 5. Clean and regap spark plug electrodes as follows: .055" (1.4 mm) = 100,000 BTU/Hr model .075" (1.9 mm) = 150,000 BTU/Hr model 6. Install spar ...

  • Jet Tools J150ECA - page 13

    13 125 PRESSURE ADJUSTMENT Plu g Air Output, Air Intake, and Lint Filters 1. Remove upper shell (see page 10). 2. Remove fi lter end cover screws using 5/16" nut- driver. 3. Remove fi lter end cover. 4. Replace air output and lint fi lters. 5. Wash or replace air intake fi lter (see Preventative Maintenance Schedule, page 8). 6. Replace ? ...

  • Jet Tools J150ECA - page 14

    14 Nozzle (100,000 BTU/Hr Model) 1. Remove upper shell (see page 10). 2. Remove fan (see page 17). 3. Remove fuel and air line hoses from burner head. 4. Remove spark plug wire from spark plug. 5. Remove spark plug from burner head using 13/16" open-end wrench. 6. Remove three screws using 5/16" nut-driver and remove burner head from comb ...

  • Jet Tools J150ECA - page 15

    15 Nozzle (150,000 BTU/Hr Model) 1. Remove upper shell (see page 10). 2. Remove fan (see page 17). 3. Remove spark plug wire from spark plug. 4. Remove spark plug from burner head using 13/16" open-end wrench. 5. Loosen fl are nut using 3/4" open-end wrench. Push fuel tube down. 6. Remove air line hose from burner head. 7. Remove three s ...

  • Jet Tools J150ECA - page 16

    16 Pump Rotor (Procedure if rotor is binding) 1. Remove upper shell (see page 10). 2. Remove fi lter end cover screws using 5/16" nut- driver. 3. Remove fi lter end cover and air fi lters. 4. Remove pump plate screws using 5/16" nut- driver. 5. Remove pump plate. 6. Remove rotor, insert, and blades. 7. Check for debris in pump. If debr ...

  • Jet Tools J150ECA - page 17

    17 Fan IMPORTANT: Remove fan from motor shaft before removing motor from heater. The weight of the motor resting on the fan could damage the fan pitch. 1. Remove upper shell (see page 10). 2. Use 1/8" Allen wrench to loosen setscrew which holds fan to motor shaft. 3. Slip fan off motor shaft. 4. Clean fan using a soft cloth moistened with kero ...

  • Jet Tools J150ECA - page 18

    18 WIRING DIAGRAM ACCESSOR Y Output Rating (BTU/Hr) 100,000 150,000 Fuel Use Only Kerosene or No. 1 Fuel Oil Fuel Tank Capacity (U.S. Gal./Liters) 9/34 13.5/51 Fuel Consumption (Gal. Per Hr./Liters Per Hr.) .74/2.8 1.10/4.16 Electric Requirements 120 volt/60 hertz 120 volt/60 hertz Amperage (Normal Run) 4.5 4.5 Hot Air Output (CFM/CMM) 480/13.6 648 ...

  • Jet Tools J150ECA - page 19

    19 ASSEMBLY, EURO PFA/PV 018A 1 2 3 4 5 6 7 WHEELS AND HANDLES FOR 100,000 AND 150,000 BTU/Hr MODELS KEY PART PART 100,000 150,000 NO. NUMBER DESCRIPTION QTY. QTY. 1 HA2203 Handles 2 — HA2205 Handles — 2 2 M12345-33 Screw, #10-24 x 1 3/4" 8 8 3 M12342-3 Wheel Support Frame 1 — M12831-3 Wheel Support Frame — 1 4 NTC-3C Nut Torque, #10-2 ...

  • Jet Tools J150ECA - page 20

    20 PFA/P 010 MOTOR & PUMP 100 EAI/EBI ILLUSTRA TED P ARTS BREAKDOWN 100,000 BTU/Hr Model 13-1 13-2 13-3 13-4 13-5 13-6 13-7 13-8 13-9 13-10 13-11 13-12 13-13 13-15 13-16 13-17 13-18 13-14 Motor and Pump Assembly BURNER HEAD 100 EAI/EBI PFA/P 022 8-2 8-6 8-5 8-4 8-3 8-1 Burner Head Assembly 8-7 1 2 3 8 9 10 11 12 13 14 15 16 17 19 20 25 28 27 29 ...

  • Jet Tools J150ECA - page 21

    21 P ARTS LIST 100,000 BTU/Hr Model This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 098511-30 Upper Shell 1 2 M15823-27 Screw, #10-16 x 1 ...

  • Jet Tools J150ECA - page 22

    22 BURNER HEAD 150 EAI/EBI PFA/P 028 ILLUSTRA TED P ARTS BREAKDOWN 150,000 BTU/Hr Model 22-1 22-2 22-3 22-4 22-5 22-6 22-7 22-8 22-9 22-10 22-11 22-12 22-13 22-14 22-15 22-16 22-17 22-18 8-7 8-6 8-5 8-4 8-3 8-2 8-1 Burner Head Assembly PFA/P 013 MOTOR & PUMP 150 EAI/EBI Motor and Pump Assembly 8-8 1 2 3 8 9 4 5 7 10 14 15 18 19 20 22 16 17 23 2 ...

  • Jet Tools J150ECA - page 23

    23 This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. P ARTS LIST 150,000 BTU/Hr Model KEY PART PART NO. NUMBER DESCRIPTION QTY. KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 098511-50 U ...

  • Jet Tools J150ECA - page 24

    24 Printed in U.S.A. 099661-01 Rev. B 8/91 W ARRANTY AND REP AIR SERVICE Contact the Spares and Service Division of: Ludlow Road, Knighton, Powys LD7 1LP Telephone: Knighton (0547) 528534 Telex: 35323 ...

Manufacturer Jet Tools Category Electric Heater

Documents that we receive from a manufacturer of a Jet Tools J150ECA can be divided into several groups. They are, among others:
- Jet Tools technical drawings
- J150ECA manuals
- Jet Tools product data sheets
- information booklets
- or energy labels Jet Tools J150ECA
All of them are important, but the most important information from the point of view of use of the device are in the user manual Jet Tools J150ECA.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Jet Tools J150ECA, service manual, brief instructions and user manuals Jet Tools J150ECA. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Jet Tools J150ECA.

A complete manual for the device Jet Tools J150ECA, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Jet Tools J150ECA by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Jet Tools J150ECA.

A complete Jet Tools manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Jet Tools J150ECA - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Jet Tools J150ECA, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Jet Tools J150ECA, that we can find in the current document
3. Tips how to use the basic functions of the device Jet Tools J150ECA - which should help us in our first steps of using Jet Tools J150ECA
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Jet Tools J150ECA
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Jet Tools J150ECA in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Jet Tools J150ECA?

Use the form below

If you did not solve your problem by using a manual Jet Tools J150ECA, ask a question using the form below. If a user had a similar problem with Jet Tools J150ECA it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)