  • Oregon Scientific AWS888N - page 1

    1 EN T ABLE OF CONTENTS About this guide ......................................................... 2 Product overview ....................................................... 2 Main unit ............................................................... 2 Remote unit .......................................................... 4 Getting started ......... ...

  • Oregon Scientific AWS888N - page 2

    EN 2 ABOUT THIS GUIDE Congratulations on your selection of the World’ s first Colour Weather Station (A WS888N) from Oregon Scientific TM . This powerful device bundles animated weather forecasting, barometric pressure monitoring, indoor / outdoor wireless temperature and humidity readings, time / date keeping, and dual alarm features into a sing ...

  • Oregon Scientific AWS888N - page 3

    3 EN FRONT VIEW 1. Colour display 2. / - Increase / decrease setting 3. ENTER - select option BACK VIEW / BA TTER Y COMP ARTMENT 1. RESET 2. SEARCH 1 2 3 1 2 AWS888N_En_R2 8/16/04, 4:28 PM 3 ...

  • Oregon Scientific AWS888N - page 4

    EN 4 REMOTE UNIT (RTGR328N) This sensor works as an RF clock receiver for this main unit but does not work with previous models. If you want to purchase additional remote sensors, select a model that does not include the RF function such as: • THGR228N / THGR238N (3-channel sensor) • THGR328N (5-channel sensor) NOTE LCD DISPLA Y (HOME MENU) 1. ...

  • Oregon Scientific AWS888N - page 5

    5 EN FRONT 1. LCD display 2. LED status indicator 3. V entilation duct 1 2 3 LCD 1. RF clock reception 2. Channel no. 3. Low battery indicator 4. T ime 5. T emperature ( ° C or ° F) 6. Relative humidity 7. T emperature / Humidity reading 1 2 3 5 6 4 7 AWS888N_En_R2 8/16/04, 4:28 PM 5 ...

  • Oregon Scientific AWS888N - page 6

    EN 6 BACK 1 2 3 4 5 6 7 8 1. W all mount (recess hole) 2. CHANNEL switch 3. RESET 4. ° C/ ° F switch 5. SEARCH button 6. EU/UK radio signal format switch 7. Battery compartment 8. Fold-out stand FOLD-OUT ST AND 1. Fold-out the stand. 2. Lock it into place. AWS888N_En_R2 8/16/04, 4:28 PM 6 ...

  • Oregon Scientific AWS888N - page 7

    7 EN GETTING ST ARTED BA TTERIES Batteries for the remote and main units are supplied with this product. Press the RESET button whenever you change batteries. Insert the batteries in the remote unit before you set up the main unit. Do not use rechargeable batteries. AC ADAPTOR (main unit) When the main unit is plugged into the power socket or batte ...

  • Oregon Scientific AWS888N - page 8

    EN 8 When the remote unit receives the radio-controlled clock signal and is paired up with the main unit, the clock in the main unit will automatically be updated. RADIO SIGNAL REMOTE SENSOR SEARCHING The RADIO SIGNAL FORMA T switch is located inside the battery compartment. Select EU (DCF) or UK (MSF). Press RESET . Reception takes 2 - 10 minutes ...

  • Oregon Scientific AWS888N - page 9

    9 EN MAIN UNIT SENSOR SEARCHING Press and hold SEARCH for 2 seconds to manually activate sensor searching. The search icon will blink until the remote signal is found or the search period times out. Search for channel signal (shown in T emp-Hygro- Pressure mode): Searching for Sensor Sensor found No sensor found Search for RF clock signal (Shown in ...

  • Oregon Scientific AWS888N - page 10

    EN 10 CLOCK SETTING Auto-synchronization should be deactivated before you manually set the clock. T o do this, follow the instructions stated below and turn the RF CLOCK function OFF in CLOCK SETTING mode. 1. From the HOME MENU access the GENERAL SETTING mode. Press / to select CLOCK SETTING, then press ENTER . 2. CLOCK SETTING mode 3. Choose the s ...

  • Oregon Scientific AWS888N - page 11

    11 EN ALARM SETTING When activated, the alarm starts quietly , then gradually becomes louder until it crescendos at 1 minute; it shuts off at two minutes. Alarm 1 Set Hour , Minute, Alarm type and Alarm on or off Alarm 2 Set Hour , Minute, Alarm type and Alarm on or off Return to previous page Exit 1. From the HOME MENU access the GENERAL SETTING m ...

  • Oregon Scientific AWS888N - page 12

    EN 12 WEA THER SETTING MODE In this mode you can adjust various weather calibration settings, such as the unit of temperature and barometric display along with altitude settings for more accurate weather forecasting. 1. From the HOME MENU access the GENERAL SETTING mode. Press / to select weather settings, then ENTER . 2. WEA THER SETTING mode T em ...

  • Oregon Scientific AWS888N - page 13

    13 EN CLOCK-ALARM MODE This is basically a viewing mode where time, date and alarm information is conveniently displayed. In this mode you can turn alarms 1 or 2 ON/OFF . • Current time • Zone time • Calendar • T wo alarm settings TURNING THE ALARM ON/OFF In Clock-Alarm mode you can switch ON/OFF alarm 1 or 2 separately without going into t ...

  • Oregon Scientific AWS888N - page 14

    EN 14 BAROMETER DISPLA Y This product tracks barometric pressure changes over the past 24 hours to provide a weather forecast. Y ou can display current and past readings by pressing the / keys. From the barometer display: THERMO AND HYGRO MEMOR Y T emperature and humidity are stored in the main memory . There are separate memories for the indoor an ...

  • Oregon Scientific AWS888N - page 15

    15 EN When the desired channel has been selected: • MAX: Press and HOLD for 2 seconds. • MIN: Press and HOLD for 2 seconds. CLEAR MIN / MAX RECORDS Press and hold and (simultaneously) for 2 seconds until you hear a beep. CURRENT THERMO-HYGRO DISPLA Y Press CHANNEL to switch between 5 outdoor channels. A current trend corresponding to the select ...

  • Oregon Scientific AWS888N - page 16

    EN 16 SYSTEM SETTINGS • V olume: Adjust system volume levels • Language: Select the display language, English, German, French, Italian or Spanish. • Silence mode: (ON) No sound will be heard in animated display mode or the main menu. • Auto rotation frequency: Adjust rotation speed (normal, fast, slow). • Sleep mode: Program the LCD displ ...

  • Oregon Scientific AWS888N - page 17

    17 EN CLOCK ALARM DISPLA Y MODE This is a display mode that presents the time, date, and alarm one of the following ways: *In Classic display mode, the hourly chime is animated with a cuckoo bird and cuckoo sound. Y ou can set which clock is displayed from the CLOCK SETTNG mode. Access the FORMA T option to toggle between Digital, Analog and Classi ...

  • Oregon Scientific AWS888N - page 18

    EN 18 LOW BA TTER Y DETECTION When battery levels get too low , the icon will appear . Also, when no adaptor is connected, the icon will be displayed. The battery / adaptor status can be seen on: • Clock display • W eather display • Remote thermo-hygro sensor NOTE The main unit will display the channel battery status when the corresponding ch ...

  • Oregon Scientific AWS888N - page 19

    19 EN T emp Shows “LLL” or “HHH” T emperature is out-of-range Set altitude / unit Calendar Unusual date / month Change language TROUBLESHOOTING Check here before contacting our customer service department. Clock Cannot adjust clock Disable auto- synchronization Clock Cannot auto- synch 1. Adjust batteries 2. Press RESET 3. Manually activate ...

  • Oregon Scientific AWS888N - page 20

    EN 20 Power Main unit 4.5V AC adaptor 4 x UM-3 (AA) 1.5V alkaline batteries (back-up) Remote unit 2 x UM-3 (AA) 1.5V alkaline batteries ABOUT OREGON SCIENTIFIC V isit our website ( www .oregonscientific.com) to learn more about Oregon Scientific products such as digital cameras; MP3 players; children's electronic learning products and games; p ...

  • Oregon Scientific AWS888N - page 21

    21 EN © 2004 Oregon Scientific. All rights reserved. CH N EC-DECLARA TION OF CONFORMITY This product contains the approved transmitter module that complies with the essential requirements of Article 3 of the R&TTE 1999 / 5 / EC Directive, if used as intended and the following standards have been applied: Safety of information technology equipm ...

Manufacturer Oregon Scientific Category Radar Detector

Documents that we receive from a manufacturer of a Oregon Scientific AWS888N can be divided into several groups. They are, among others:
- Oregon Scientific technical drawings
- AWS888N manuals
- Oregon Scientific product data sheets
- information booklets
- or energy labels Oregon Scientific AWS888N
All of them are important, but the most important information from the point of view of use of the device are in the user manual Oregon Scientific AWS888N.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Oregon Scientific AWS888N, service manual, brief instructions and user manuals Oregon Scientific AWS888N. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Oregon Scientific AWS888N.

A complete manual for the device Oregon Scientific AWS888N, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Oregon Scientific AWS888N by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Oregon Scientific AWS888N.

A complete Oregon Scientific manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Oregon Scientific AWS888N - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Oregon Scientific AWS888N, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Oregon Scientific AWS888N, that we can find in the current document
3. Tips how to use the basic functions of the device Oregon Scientific AWS888N - which should help us in our first steps of using Oregon Scientific AWS888N
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Oregon Scientific AWS888N
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Oregon Scientific AWS888N in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Oregon Scientific AWS888N?

Use the form below

If you did not solve your problem by using a manual Oregon Scientific AWS888N, ask a question using the form below. If a user had a similar problem with Oregon Scientific AWS888N it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)