Manual Rheem RS47-21BP

40 pages 6.36 mb
Download

Go to site of 40

Summary
  • Rheem RS47-21BP - page 1

    The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations for the proper installation and adjustment of the water heater; and two, for the owner–operator , to explain the features, operation, safety precautions, maintenance and troubleshooting of the water heater . This manual also includes ...

  • Rheem RS47-21BP - page 2

    Safety Information Introduction . . . . . . . . . . . . 3, 4 Safety Precautions . . . . . . . 5, 6 Installation Instructions Location . . . . . . . . . . . . . . . . . 7 Unit Specifications & Parts 7,8 Pre-Installation Review . . . . . 9 System Requirements . . . . . 10 Pitch Requirements . . . . . . . . 1 1 Roof Requirements . . . . 12, 13 Ele ...

  • Rheem RS47-21BP - page 3

    Intr oduction Thank you for purchasing a solar water heating system. It is one of the most effective and trouble-free systems available today . In addition to reducing your water-heating bills, it will help preserve precious natural resources by using free energy from the sun. As with an electric or gas water heater , your new solar water heating s ...

  • Rheem RS47-21BP - page 4

    4 Intr oduction continued... While your system is one of the most efficient available, there are two simple steps you can take to increase your water-heating cost savings. Keep the use of the Backup Heater to a Minimum Y ou can save the most money on your water-heating bills by using the backup heater on your system as little as possible. If the su ...

  • Rheem RS47-21BP - page 5

    Time/T emperatur e Relationship in Scalds T emperature T ime T o Produce a Serious Burn 120°F More than 5 minutes 125°F 1½ to 2 minutes 130°F About 30 seconds 135°F About 10 seconds 140°F Less than 5 seconds 145°F Less than 3 seconds 150°F About 1½ seconds 155°F About 1 second T able courtesy of Shriners Burn Institute The chart shown abo ...

  • Rheem RS47-21BP - page 6

    6 IMPOR T ANT SAFETY INFORMA TION. READ ALL INSTRUCTIONS BEFORE USING . W ARNING! For your safety , the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent pr operty damage, personal injury , or loss of life. Be sure to r ead and understand the entire Use and Car e Manual before attem ...

  • Rheem RS47-21BP - page 7

    Installing the water heater . The location chosen for the water heater must take into consideration the following: Local Installation Regulations This water heater must be installed in accordance with these instructions, local codes, utility codes, utility company requirements or , in the absence of local codes, the latest edition of the National E ...

  • Rheem RS47-21BP - page 8

    Installing the water heater . 8 Solar Collector 3/4” Union Nut 3/4” T/P V alve Fill Fitting Collector Nut 18mm Union Cone 3/4” Check V alve (NOT INCLUDED) Collector Hot Pipe Collector Plug Lag Screw (5/16” x 1 3/4”) (NOT INCLUDED) 3/4” Cold W ater Expansion V alve Collector Clamps 3/4” T ail Plug T empering V alve PR6 Jacket Relief V ...

  • Rheem RS47-21BP - page 9

    9 Pr e-Installation These installation inspection procedur es include; • Review of local building codes for site requirements and specific guidelines for plumbing and electrical installation. • Inspection of installation site. • Completion of the Pre-installation Checklist, including customer ’ s signature. Site Inspection Equipment • Pre ...

  • Rheem RS47-21BP - page 10

    Installing the water heater . 10 The system must face between 135 - 225° (Ideal direction is true South): (Refer to the Figure on the right). Installations outside this range requir e either an additional collector or frame. Site must be shade-free year -round and clear of obstructions. Plumbing/Electrical stub-out • 1' 6" left side fo ...

  • Rheem RS47-21BP - page 11

    11 Pitch Requir ements Correct operation r equires a 15°- 45° pitch (slope). This can be done by using the roof slope itself or a frame CAUTION: DO NOT install on a roof with a pitch beyond 45°. ! Use pitch gauge and compass and complete the following steps. Record the results on the checklist. • Record pitch and compass bearing of proposed in ...

  • Rheem RS47-21BP - page 12

    Installing the water heater . Roof Survey Record the following on the checklist: • The type of roofing material (tile, shingle, tar & gravel, metal, etc.). • The condition of the roof. Note any repair requirements needed prior to installation. • Draw diagram (top view) as shown below , of installation area. Mark location of the system and ...

  • Rheem RS47-21BP - page 13

    13 Conventional Roof Modifications T russ Frame Modifications Allowable Spans for T russes 2” x 4” T op Chord 2” x 6” T op Chord 24” O.C. Kickers Bottom Chord Pitch Roof Material 21” 32” X 2”x4” or 2”x6” 3:12¹ T ile 24” 36” X 2”x4” or 2”x6” 3:12¹ Shake 25” 38” X 2”x4” or 2”x6” 4:12² T ile 28” 42“ ...

  • Rheem RS47-21BP - page 14

    14 Installing the water heater . Review the checklist for installation r equirements. Check the following before beginning installation. Permits Obtain required permits before installation. W ork Force An 80 gallon storage tank weighs up to 242 lbs empty , requiring a crew of two or more to install. Inventory Review Section on Frames, included hard ...

  • Rheem RS47-21BP - page 15

    NOTICE:All wiring must conform to local codes or the latest edition of National Electrical Code ANSI/NFP A 70. W ARNING: Any wiring outside of the house should be rated for the appr opriate weather conditions. If the system is being used as a pre-heater to an existing water heater , the electrical r eview and installation may not be requir ed. A 24 ...

  • Rheem RS47-21BP - page 16

    16 Installing the water heater . T ypical Installation Choose the installation type from the following; 1. As a replacement for an existing water heater (Preferred). 2. As the stand alone source of hot water for new construction or locations without a previous water heater . 3. As a pre-heater to an existing water heater . NOTICE: Using the system ...

  • Rheem RS47-21BP - page 17

    17 Plumbing System Schematic for Replacement of Existing Electric W ater Heater T ank 3/4” 3/4” Plumbing System Schematic for Installation of stand alone W ater Heater V alve Settings: Solar Only = (TWV1-1) + (TWV2-1) + (Pre Heat OFF) Storage Only = (TWV1-2) + (TWV2-2) + (Pre Heat OFF) Solar Pre Heat = (TWV1-1) + (TWV2-2) + (Pre Heat ON) TWV1 = ...

  • Rheem RS47-21BP - page 18

    18 Installing the water heater . T ypes of Roof Installation Installation types are divided into the following: S tandard Installation: The system is mounted to wood or Unistrut runners directly to the roof with no need for pitch or directional changes. Metal / S turdy Tile Installation: The system is mounted directly to the roof with no need for p ...

  • Rheem RS47-21BP - page 19

    Roof Pr eparation Refer to the checklist for necessary roof modifications on page 12. Install supports for Fragile T ile Roof The system may be installed directly on most roof types if the roof is in good condition with adequate drainage. For other types of roofs, do the following: Clear area of roofing material from top of roof to lower edge of ro ...

  • Rheem RS47-21BP - page 20

    20 Installing the water heater . W ood Runner Detail for 16” & 24” On-Center Rafters for S tandard Installation Collector Extrusion Detail for S tandard Installation CAUTION: The Extrusion must slope 1/2” per collector from horizontal (hot pipe side to be higher) for the system to work correctly . ! Metal or Tile Installation 1. Mark tank ...

  • Rheem RS47-21BP - page 21

    21 Collector Extrusion & S trap Installation Detail - T ile Roof CAUTION: S traps must be attached directly onto the rafters or trussed not less than 39” apart and not more than 63" apart. ! CAUTION: The Extrusion must slope 1/2” per collector from horizontal (hot pipe side to be higher) for the system to work correctly . ! Collector E ...

  • Rheem RS47-21BP - page 22

    22 Installing the water heater . Frame Installation continued.... • Drill each runner in center and 6" from runner ends and screw to rafters or trusses with 5/16" x 6" lag screws and washers, • Flash and seal all roof penetrations. 3. Move all pieces of Frame to roof and assemble (refer to Figure below). 4. Attach Frame to runner ...

  • Rheem RS47-21BP - page 23

    23 Collector Installation Collector Union Collector Union Collector Nut Fill Assembly Collector Nut Collector Plug Collector Fitting Installation Detail 1. Set collectors in place, resting lower ends on collector extrusion or frame, 2. Remove plugs from corners of the collectors 3. Connect collectors with collector unions. Do not tighten fully (ref ...

  • Rheem RS47-21BP - page 24

    24 Installing the water heater . S torage T ank Installation CAUTION: Do not damage internal collector absorber with screws. ! Collector Hot Pipe T ank Clamp 1. Spread open (4) four tank clamps (2 for metal or sturdy tile installations) to allow room to clear tank foot, and attach to rear foot of tank. 2. Place the (2) two tank-to-collector spacers ...

  • Rheem RS47-21BP - page 25

    25 6. Level the tank. 7. T ighten the tank system in place. 8. T ighten hot pipe and downpipe connections. 9. Install tee adapter (See figure at right). 10. Install T/P V alve into tee adaptor (See figure at right). 1 1. Install tail plug in right end of tank (See figure at left). 1 1. Continue with plumbing installation as described in section bel ...

  • Rheem RS47-21BP - page 26

    26 Installing the water heater . See Key to S tub - Out Details Below: All plumbing and wiring Stub-Outs to be a minimum of 18" above roof frame. (E) Electrical service (240V , 20-amp required only if using auxiliary electrical backup in tank) (R) 3/4" Relief Line (H) Hot Supply to House (C) 3/4" Cold Supply to Rheem thermosiphon tan ...

  • Rheem RS47-21BP - page 27

    CAUTION: On new construction, Do Not fill storage tank and/or charge the closed loop system until the water heater is ready for use. Cover the collectors until the system is filled and charged. Place a tag on the system if it s not filled and charged. ! Closed Loop Fluid The closed loop must be filled ONL Y with Hartgard solution and potable water ...

  • Rheem RS47-21BP - page 28

    28 Installing the water heater . • Rectify leakage if observed at any of the connections and repeat steps indicated on previous page. • Release the pressure from the closed loop by loosening the PR6 valve from the T est Block. • When the pressure is zero, tighten the PR6 Jacket Relief V alve. • Once again remove the Fill Plug from the Fill ...

  • Rheem RS47-21BP - page 29

    29 Connect S torage T ank to Electrical Supply • Use only a utility supply having a maximum of 240 volt, 1 phase, 60Hz, power supply . W ARNING: T urn off all power to avoid injury . • The water heater must always be connected to the ground in accordance with the local codes. • Connect the branch circuit equipment grounding means and system g ...

  • Rheem RS47-21BP - page 30

    30 Safety Pr ecautions Do turn off power to water heater if it has been subjected to over heating, fire, flood, physical damage. Do Not turn on water heater unless it is filled with water . Do Not turn on water heater if cold water supply shut-off valve is closed. If there is any difficulty in understanding or following the Operating Instructions o ...

  • Rheem RS47-21BP - page 31

    31 If adjustment is necessary… T urn off the power to the water heater . Remove the jacket access panel. Using a small screwdriver , set the thermostat dial pointer to the desired temperature. Replace the jacket access panel. T urn on the power to the water heater . 5 5 8 0 75 7 0 6 5 6 0 5 0 : E W T 1L 2 S-2 0 3 D IFF EC O : 83 8 L 1 1 0 MAY 20 ...

  • Rheem RS47-21BP - page 32

    Anode Rod This water heater is equipped with an anode rod designed to prolong the life of the glass lined tank. The anode rod is slowly consumed, thereby eliminating or minimizing corrosion of the glass lined tank. W ater sometimes contains a high sulfate and/or mineral content and together with cathodic protection process can produce a hydrogen su ...

  • Rheem RS47-21BP - page 33

    Car e and cleaning of the water heater . 33 V acation and Extended Shut-Down NOTICE: Refer to the Hydrogen Gas Caution i n the Operating Instructions. DANGER: Use extreme car e to avoid falling while on a ladder or the r oof. If a roof section does not appear to be solid under foot, do not subject it to any added weight until it is adequately reinf ...

  • Rheem RS47-21BP - page 34

    34 Befor e Y ou Call For Service… T roubleshooting T ips Save time and money! Review the chart on this page first and you may not need to call for service. Problem Possible Causes What T o Do Not enough Hot W ater Solar circuit breaker tripped Reset/replace as necessary or fuse blown Safety Thermostat tripped Reset/replace as necessary . or malfu ...

  • Rheem RS47-21BP - page 35

    35 T roubleshooting T ips Save time and money! Review the chart on this page first and you may not need to call for service. Problem Possible Causes What T o Do No Hot W ater Hot water tempering valve Repair/replace as necessary fouled Pressure imbalance (over 5 psi) Locate and repair cause of imbalance. between hot and cold water lines Fouled pres ...

  • Rheem RS47-21BP - page 36

    Frames Installations using 17.5° “A” Frames This ‘A ’-Frame is not for use in areas susceptible to hurricanes. In areas susceptible to hurricanes or very high winds, a separate set of instructions and a hurricane frame mounting kit is required and available from Rheem. The hurricane frame mounting kit is suitable for with pitch and low pit ...

  • Rheem RS47-21BP - page 37

    Frames continued..... Side Pitch Installations (T ile Roof) Assemble the ‘A ’ Frame kit and loosely bolt the baseplate to one side of the angle frame. For installations on a roof with a pitch greater than 20°, a ‘U’ bracket and small pipe legs should be used on top of the baseplate as shown. Note that the baseplate is positioned towards th ...

  • Rheem RS47-21BP - page 38

    38 Against Pitch Installations (T iled Roof) Assemble the stand and then loosely bolt the baseplate to the frame in position. For installations on a roof with a pitch greater than 20°, a ‘U’ bracket and small pipe legs should be used on top of the baseplate. The frame installation proceeds following the instructions for side pitch installation ...

  • Rheem RS47-21BP - page 39

    39 Frames continued..... V ariations for Shallow Pitch or Flat Deck Roofs On shallow pitch roofs (less than 8°) of metal or fibreboard materials, the frame may be installed without using the pipe legs, provided that the inclination of the solar collector remains greater than 8°. On flat roofs, the assembled frame may be installed without the base ...

  • Rheem RS47-21BP - page 40

    40 IF YOU NEED SER VICE 1. Should you have any questions about your new water heater , or if it requires adjustment, repair , or routine maintenance, it is suggested that you first contact your installer , plumbing contractor or previously agreed upon service agency . In the event the firm has moved, or is unavailable, refer to the telephone direct ...

Manufacturer Rheem Category Swimming Pool Heater

Documents that we receive from a manufacturer of a Rheem RS47-21BP can be divided into several groups. They are, among others:
- Rheem technical drawings
- RS47-21BP manuals
- Rheem product data sheets
- information booklets
- or energy labels Rheem RS47-21BP
All of them are important, but the most important information from the point of view of use of the device are in the user manual Rheem RS47-21BP.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Rheem RS47-21BP, service manual, brief instructions and user manuals Rheem RS47-21BP. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Rheem RS47-21BP.

Similar manuals

A complete manual for the device Rheem RS47-21BP, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Rheem RS47-21BP by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Rheem RS47-21BP.

A complete Rheem manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Rheem RS47-21BP - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Rheem RS47-21BP, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Rheem RS47-21BP, that we can find in the current document
3. Tips how to use the basic functions of the device Rheem RS47-21BP - which should help us in our first steps of using Rheem RS47-21BP
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Rheem RS47-21BP
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Rheem RS47-21BP in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Rheem RS47-21BP?

Use the form below

If you did not solve your problem by using a manual Rheem RS47-21BP, ask a question using the form below. If a user had a similar problem with Rheem RS47-21BP it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)