  • Agilent Technologies 81200 - page 1

    Agilent 81200 The 81200 Data Generator/ Analyzer Platform Configuration Guide Release 2.1 Simplify your verification and characterization process ...

  • Agilent Technologies 81200 - page 2

    The Agilent T echnologies 81200 data generator/analyzer platform The A gilent 81200 is a modular plat- form consisting of front-ends, mod- ules, mainframes and user int erfaces, which can be tailored to your specific test needs. This guide aims t o help you choose the right components. In this context, tw o dif ferent fundamen- tal possibilities in ...

  • Agilent Technologies 81200 - page 3

    3 Product Description Model Number Quantity Generator front-ends Generator front-ends 660MHz, RZ/NRZ, 3.5 Vpp, variable transition times SMA (f). Agilent E4838A Generator front-end 330 MHz, RZ/NRZ, variable transition times SMA (f). Agilent E4842A Generator front-end 660 MHz, RZ/NRZ, single channel, 2.5 Vpp SMA (f). Agilent E4843A Dual generator fr ...

  • Agilent Technologies 81200 - page 4

    4 Expander frames F or more module slots, one or tw o Agilent E4848B expander frames can be connect ed. To do this, a VXI exten- der module (Agilent E4849B Opt 002) is required. The module occupies one of t he ot herwise free slots and is con- nected to a cor responding VXI exten- der t hat is supplied as par t of the expander frame. Note t hat, wh ...

  • Agilent Technologies 81200 - page 5

    STEP 5: Choosing the user inter- face, support options, installation options, and test accessories User Interface The compact choice is the display and entr y panel that mounts onto the front of the mainframe and hinges f or optimum viewing/connector access. It can only be used when connected to the frames A gilent E4840A and Agilent E4849B in the ...

  • Agilent Technologies 81200 - page 6

    6 Controlling instruments with the Agilent 81200 (only for "proprietary systems") The embedded PC of t he frames Agilent E4849B and Agilent E4840A includes a GPIB inter face so that other GPIB instr uments can be con- trolled with the Agilent 81200 plat- form (f igure 6). To do t his, you need to install suitable controller sof tware such ...

  • Agilent Technologies 81200 - page 7

    7 DUT Fixturing F or conv enient and reliable DUT fix- turing for DUT’s wit h up to 192 pins, there is t he A gilent E4839A Test Fixture available. F or details, please consult Agilent E4839A Test Fixture, data sheet, p/n 5968-3580E. Simulation data link for VHDL and V erilog BestLink/81200, a simulation data link is available t o process and tra ...

  • Agilent Technologies 81200 - page 8

    8 Upgrading an existing Agilent 81200 data generator/analyzer platform The A gilent 81200 Dat a Generat or/ Analyzer Platform can be extended or adapted as needed. Front-ends, mod- ules and expander frames can be added at any time. Orders for individ- ual units are supplied wit h t he inst al- lation instr uctions. User software upgrades Revisions ...

  • Agilent Technologies 81200 - page 9

    9 Systems needing more than ten module slots The A gilent E4849B mainframe can be ext ended using the Agilent E4848B expander frame. The maximum con- figuration with one expander is: • Agilent E4849B mainframe • Option 001 display and entr y panel (ormonit or/k eyboard/mouse options) • Option 002 VXI extender module • Agilent E4805A clock m ...

  • Agilent Technologies 81200 - page 10

    I Fax Co v er Sheet A gilent 81200 Conf iguration Guide To : OFC/BVS A gilent T echnologies GmbH, Herrenberger Straße 130, 71034 Böblingen, Ger man y F ax Number : +49 (7031) 464-6532 If y ou ha ve problems wit h t his fax, please cont act: +49 (7031) 464-7 67 4 From: Name: Compan y: T elephone: Email: Sales represent ativ e: Agilent order no. (m ...

  • Agilent Technologies 81200 - page 11

    III Configuration Sheet: E4840A Small Frame Please choose one of t he front- ends: E4837A E4838A E4843A E4844A E4845A E4846A E4847A and writ e t he product number (e.g. E4837A) in the appropriate slot Front-End 4 Front-End 3 Front-End 2 Front-End 1 0 1 2 E4805A E4831A E4841A E4831A E4841A E4831A  Slot ...

  • Agilent Technologies 81200 - page 12

    V Configuration Sheet: Mainframe E4849B as standalone frame 1 23 4 5 6 7 8 9 0 10 11 12 Front-End 1 Fr ont-End 2 Front-End 3 Front-End 4 E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A Please choose one of the front-ends: E4837A, E4838A, ...

  • Agilent Technologies 81200 - page 13

    VII 1 23 4 5 6 7 8 9 0 10 11 12 Front-End 1 Fr ont-End 2 Front-End 3 Front-End 4 E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A Please choose one of the front-ends: E4837A, E4838A, E4843A, E4844A, E4845A, E4846A, E4847 and write the pro ...

  • Agilent Technologies 81200 - page 14

    IX 1 23 4 5 6 7 8 9 0 10 11 12 Front-End 1 Fr ont-End 2 Front-End 3 Front-End 4 E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4831A Please choose one of the front-ends: E4837A, E4838A, E4843A, E4844A, E4845A, E4846A, E4847 and write the prod ...

  • Agilent Technologies 81200 - page 15

    XI 1 23 4 5 6 7 8 9 0 10 11 12 Front-End 1 Fr ont-End 2 Front-End 3 Front-End 4 E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4805A E4831A E4841A E4831A Please choose one of the front-ends: E4837A, E4838A, E4843A, E4844A, E4845A, E4846A, E4847 and write the prod ...

  • Agilent Technologies 81200 - page 16

    Related Literature • Agilent 81200 Data Generator/Analyzer Platform, brochure • Agilent 81200 Data Generator/Analyzer Platform, data sheet specifications • Agilent E487 4A Characterization Software Components, dat a sheet • Agilent E4839A T est Fixture, dat a sheet • BestLink/81200 Simulation Data Link for the Agilent 81200 Data Generator ...

Manufacturer Agilent Technologies Category Laptop

Documents that we receive from a manufacturer of a Agilent Technologies 81200 can be divided into several groups. They are, among others:
- Agilent Technologies technical drawings
- 81200 manuals
- Agilent Technologies product data sheets
- information booklets
- or energy labels Agilent Technologies 81200
All of them are important, but the most important information from the point of view of use of the device are in the user manual Agilent Technologies 81200.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Agilent Technologies 81200, service manual, brief instructions and user manuals Agilent Technologies 81200. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Agilent Technologies 81200.

A complete manual for the device Agilent Technologies 81200, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Agilent Technologies 81200 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Agilent Technologies 81200.

A complete Agilent Technologies manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Agilent Technologies 81200 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Agilent Technologies 81200, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Agilent Technologies 81200, that we can find in the current document
3. Tips how to use the basic functions of the device Agilent Technologies 81200 - which should help us in our first steps of using Agilent Technologies 81200
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Agilent Technologies 81200
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Agilent Technologies 81200 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Agilent Technologies 81200?

Use the form below

If you did not solve your problem by using a manual Agilent Technologies 81200, ask a question using the form below. If a user had a similar problem with Agilent Technologies 81200 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)