  • Raypak 6300 - page 1

    Raypak ® Swimming Pool Heat Pump OWNER’S MANUAL This manual should be maint ained in legible condition and kep t adjacent to the heat pump or in a safe p lace for future use. For additional information call: (800) 260-2758 Manual Ef fective Date: 6/24/2005 De ve lop ed an d p ri nt ed i n U .S .A . Part No. 00-0 2107A 5300 8300 6300 Models The i ...

  • Raypak 6300 - page 2

    i PRODUCT SAFETY SIGNS AND LABE LS This manual, as well as the pool/spa heat pum p itself, contains ANSI-approved product safety signs and labels. Please read these signs and labe ls, as they convey important safety information about hazards that may be potentially present in and around the heat pump. They are classified according to relative serio ...

  • Raypak 6300 - page 3

    ii Swimming Pool Heat Pump OWNER’S MANUAL - Mo dels 5300, 6300, 8300 CONTENTS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 I. Installation Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 II. El ...

  • Raypak 6300 - page 4

    1 Intr oduction This pool heat pump is an electromec hanical machine that incorporates a pressurized refrigerant gas in a sealed sys tem. ONL Y trained and qualified service personnel are authorized to install or service this eq uipment. Without proper training a nd knowledge of such equipment, any attempt to inst all or service the unit could resu ...

  • Raypak 6300 - page 5

    2 Situate the pool heat pump caref ully to minimize installati on costs while providing maximum efficiency of operation, and to allow adequate service access, as follows: • For unrestricted air intake and service access, pos ition each side of the unit at least 1 ft (30 cm) from walls, pipes and other obstructions. • The unit is designed for ou ...

  • Raypak 6300 - page 6

    3 III. W ater Connections The heat pump inlet and outlet connections are NOT interchan geable. They must be connected as instructed below . 1. Connect the heat pump in the return water line between the filter a nd the pool/spa. See page 10, Plumbing Diagrams. 2. Connect the filter outlet to the fitting marked WA T E R I N at the bottom front of the ...

  • Raypak 6300 - page 7

    4 interruption, this solid state devi ce will prevent compressor rest art for approximately 5 minutes. Upon power failure or interruption, a 6 to 8 minute delay will also be initiated. Refrigerant Low Pressur e Control : S tops the compressor if refrigerant suction (low side) pressure falls too low as a result of a malfunc tion, loss of charge or e ...

  • Raypak 6300 - page 8

    5 V . System S tart-Up 1. V erify that th e Power lamp is ON and that the pool/spa pump is running and circulating properly . 2. V erify that the control panel Sp a-Remote-Pool switch is in the Remote (OFF) position; see the figure. 3. T urn the control switch to either Pool or Sp a to turn the system ON and raise the thermostat setting above the c ...

  • Raypak 6300 - page 9

    6 VII. Heat Pump Running T ime 1. Determine the length of pump and heat pump operating time necessary for your particular requirements. Minimum run time should be the required hours to attain proper water filtration. Maximum run time obviously is 24 hours per da y , or as required to reach desired water temperature, and depends on such things as we ...

  • Raypak 6300 - page 10

    7 X. Maintenance NOTE: The heat pump MANUF ACTURER IS NOT RESPONSIBLE for maintenance adjustments. The following maintenance procedures are desi gned to keep your heat pump operating at a high level of reliability . Maintenance must be performed on a pe riodic basis to maintain warranty coverage and prevent system failures and performance degradati ...

  • Raypak 6300 - page 11

    8 • Is water condensing on the evaporator and intern al copper pipes? This is also evidence of heat removal from the air . When the air is c ool with low humidity , condensation may not be evident. • How long has the unit been operating? During in itial pool heating in cold weather , it may require a week to elevate the water temperature to a c ...

  • Raypak 6300 - page 12

    9 C. CONDENSA TION SEE MS EXCESSIVE Heat pumps can produce a large amount of condensation (water ) during operation. If you suspect that the heat pump is leaking: a. Use a pool chemistry test kit to confir m there is no chlorine in the condensation. Or , b. Shut the heat pump OFF and leave the filter pump runn ing to see if the water stops dripping ...

  • Raypak 6300 - page 13

    10 Plumbing Diagrams For systems with pum ps of 2 HP or greate r (ove r 80 gpm ) , an ex te rn al bypass is required. Adjust the bypass valv e to divert a m inimum of 40 gpm through the hea t pu mp. Con nections ar e 2 -inch un ions. Plumb the heat pump af ter the filter and before any chlorinators. Wa t e r I n (from pool or spa) Wa t e r O u t (t ...

Manufacturer Raypak Category Heat Pump

Documents that we receive from a manufacturer of a Raypak 6300 can be divided into several groups. They are, among others:
- Raypak technical drawings
- 6300 manuals
- Raypak product data sheets
- information booklets
- or energy labels Raypak 6300
All of them are important, but the most important information from the point of view of use of the device are in the user manual Raypak 6300.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Raypak 6300, service manual, brief instructions and user manuals Raypak 6300. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Raypak 6300.

Similar manuals

A complete manual for the device Raypak 6300, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Raypak 6300 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Raypak 6300.

A complete Raypak manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Raypak 6300 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Raypak 6300, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Raypak 6300, that we can find in the current document
3. Tips how to use the basic functions of the device Raypak 6300 - which should help us in our first steps of using Raypak 6300
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Raypak 6300
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Raypak 6300 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Raypak 6300?

Use the form below

If you did not solve your problem by using a manual Raypak 6300, ask a question using the form below. If a user had a similar problem with Raypak 6300 it is likely that he will want to share the way to solve it.

Copy the text from the picture