Manual SMC Networks 1000

70 pages 1.09 mb
Download

Go to site of 70

Summary
  • SMC Networks 1000 - page 1

    T igerSwitch 1000 Gigabit Ether net Switch ◆ 6 auto-MDIX 10/10 0/1000B ASE-T ports ◆ T wo slots for hot-swappable 1000B ASE-X GBIC modules ◆ 16 Gbps of agg re gate swit ch bandwidt h ◆ Support for redundant po wer unit ◆ Up to four port trunks per swit ch ◆ Port mirroring for non-i ntrusi ve analysis ◆ QoS support for t wo-le v el pri ...

  • SMC Networks 1000 - page 2

    ...

  • SMC Networks 1000 - page 3

    6 Hughes Irvine, CA 9261 8 Phone: (9 49) 707-24 00 T igerSwitch 1000 Installation Guide From SMC’ s T iger line of feature-rich w o rkgroup LAN solutions October 20 0 1 Pub. #150 200001800A R0 2 ...

  • SMC Networks 1000 - page 4

    Informati on furnished by SMC Networ ks, Inc. (SMC) is believed to be accu rate and r eliable. Ho wever , no re sponsibi lity is assumed b y SMC for its us e, nor fo r any inf ringe ments of patents or oth er right s of thi rd part ies whic h may r esul t from i ts use. No lice nse is gr anted by imp lication or otherwise under any paten t or pat e ...

  • SMC Networks 1000 - page 5

    L IMITED W ARRAN TY Limited Wa rranty Limite d W arranty St atemen t: SMC Networks, Inc. (“SMC”) warrants its prod ucts to be free from defe cts in wor kmanship and materi als, under n ormal us e and service, for the applicable warranty term. All SMC prod ucts carry a standard 90-day limited warra nty fr om the d ate of purc hase from SMC o r i ...

  • SMC Networks 1000 - page 6

    L IMITED W ARRAN TY IN F ACT OR BY OPERA TION OF LA W , ST A TUTORY OR OTHER WISE, INCLUD ING W ARRANTIES OR COND ITION S OF ME RCHANT ABIL ITY AN D FITNE SS FOR A P ARTICUL AR PURPOSE . SMC N EITHER AS SUMES NOR A UTHORIZES ANY OTHER PERSON TO A SSUME FO R IT A NY OTH ER LIA BILITY IN CONN ECTION WITH THE SALE, INST ALLA TION, MA INTENANCE OR USE ...

  • SMC Networks 1000 - page 7

    i C OMPLIANCES FCC - Class A This equip ment gene rates, uses , and can ra diate radio f reque ncy ene rgy and, if n ot instal led and u sed in ac cordan ce wit h the i nstr uctio n manua l, may cause inter fere nce to radio communications. It has been tested and found to comply with the limits for a Class A comp uting device p ursuant to Subp art ...

  • SMC Networks 1000 - page 8

    C OMPLIANCES ii EC Conformance Declaration - Class A SMC contact for these produc ts in Europe is: SMC Netw orks Euro pe, Edificio Con ata II, Calle Fruc tuós Gelaber t 6-8, 2 o , 4 a , 08970 - Sant Joan Despí, Barcelona, Spai n. This in formation techno logy equ ipment complies with th e requirem ents o f the Council Directive 89/336/EE C on the ...

  • SMC Networks 1000 - page 9

    C OMPLIANCES iii T aiwan BSMI Class A Australia AS/NZS 3548 (1995) - Class A SMC cont act for product s in Au stralia is: SMC C omm unica tions Pty. Ltd. Suite 18, 12 T ryon Road , Lin dfie ld NSW 2070 , Phon e: 61-2- 941604 37 Fax: 61-2- 941604 74 ...

  • SMC Networks 1000 - page 10

    C OMPLIANCES iv Safety Compliance W arning: Fiber Optic Port Sa fety Avertissment: Ports pour fibres optiques - sécurité sur le plan optique W arnhinweis: Faser optikanschlüsse - Opt ische Sicher heit Underwrite rs Laboratories Compliance Statement Important! Before maki ng connect ions, ma ke sure yo u have th e correct cord set. Check it (r ea ...

  • SMC Networks 1000 - page 11

    C OMPLIANCES v Wichtige S icherheitshinwe ise (Ger many) 1. Bitte les en Sie di ese Hinwei se sorgfältig d urch. 2. Heben Sie diese Anleitu ng für den späteren Gebrauch auf. 3. V or jedem R einigen ist das Gerät vom Stro mnetz zu trennen. V e rwenden Sie keine F lüssigode r Aerosol reinige r . A m beste n eignet sich ein ang efeuchte tes Tuch ...

  • SMC Networks 1000 - page 12

    C OMPLIANCES vi ...

  • SMC Networks 1000 - page 13

    vii T ABLE OF C ONTENTS Index 7 1 About the TigerSwitch 1000 1-1 Overvie w . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Descript ion of Har dware . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 1000BASE- T Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 GBIC Sl ots . . . . . . . . ...

  • SMC Networks 1000 - page 14

    T ABLE OF C ONTENTS viii Option al Rack-M ounting Equipmen t . . . . . . . . . . . . . . . 3-2 Mounti ng . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Rack Mo unting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Deskto p or Shelf Mounting . . . . . . . . . . . . . . . . . . . . . 3-5 Instal ling ...

  • SMC Networks 1000 - page 15

    T ABLE OF C ONTENTS ix Switch Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-2 Management Featu res . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3 Standard s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3 Complianc es . . . . . . . . . . . . . . . . . . . . . . . ...

  • SMC Networks 1000 - page 16

    T ABLE OF C ONTENTS x ...

  • SMC Networks 1000 - page 17

    1-1 C HAPTER 1 A BOUT THE T IGER S WITCH 1000 Overview The Ti gerSwi tch 10 00 is a h igh-perfo rmance Gigabi t Ethe rnet switc h designed for the network cor e. It provides eight 1000 Mbp s port s that can sig nific antly impr ove th e performa nce of yo ur netw ork’s back bone, and del iver the th roughp ut needed to suppor t a broad r ange of ...

  • SMC Networks 1000 - page 18

    A BOUT THE T IGER S WIT CH 1000 1-2 Figure 1-1. Front and Re ar Panels Desc ripti on of Hardwa re 1000BASE-T Ports These ports are RJ-45 po rts that operate at 10 Mbps, 100 Mb ps and 1000 Mb ps, full and ha lf duplex. The port s can b e conne cted t o other IEEE 802.3ab 1 000BASE-T compliant devi ces up to 100 m (328 ft .) away u sing C ategory 5 t ...

  • SMC Networks 1000 - page 19

    A BOUT THE T IGER S WIT CH 1000 1-3 Status LEDs The LED s, whic h are loc ated on the fr ont pan el for easy viewing, are show n below an d described in the following table. Figure 1-2. Port and System LEDs Port and System Status LEDs LED Condition Status Power On Gre en Switc h is re ceiving power . Off Power off or failur e. RPU On Green Redundan ...

  • SMC Networks 1000 - page 20

    A BOUT THE T IGER S WIT CH 1000 1-4 Network Management Agent The Ti gerSwitc h 1000 includes a built -in net work managem ent agent. The agent offers a va riety of m anageme nt options , includ ing SNMP , RMON and a W e b-based interface. The switch also provides a serial port on the rear p anel for out-o f-band manag ement. This i s an RS-23 2 ser ...

  • SMC Networks 1000 - page 21

    A BOUT THE T IGER S WIT CH 1000 1-5 Spanning Tree Protocol The Ti gerSwi tch 10 00 supp orts AN SI/I EEE 802.1 d Spannin g T ree Prot ocol. This pr otocol adds a level of faul t toleran ce by allowi ng two or more redu ndant c onnecti ons to be created between a pair of LAN segmen ts. Whe n there are multip le physic al paths betwee n segment s, th ...

  • SMC Networks 1000 - page 22

    A BOUT THE T IGER S WIT CH 1000 1-6 Multica st Swit ching Specific multicast traffic c an be assigned to its own VLAN to ensure that it doe s not interfer e with normal network tr affic and to guarant ee real-time delivery by se tting th e required prio rity leve l for th e desig nated V LAN. Th e switc h uses IG MP Snoop ing and IGMP to manag e mu ...

  • SMC Networks 1000 - page 23

    A BOUT THE T IGER S WIT CH 1000 1-7 Features a nd Benefit s Connectivity ◆ 6 10 /100/10 00BASE- T RJ -45 por ts ◆ Two sl ots for opti onal GBIC modu les ◆ Auto- negotiatio n of duplex mode and flow cont rol ◆ IEEE 802.3ab Gigabi t Ethernet compl iance ensur es compatib ility with stan dards-bas ed network card s and switc hes from an y vend ...

  • SMC Networks 1000 - page 24

    A BOUT THE T IGER S WIT CH 1000 1-8 Management ◆ “ At-a -gla nce ” LEDs for easy troubl eshooti ng ◆ Network m anagement ag ent: • Suppor ts Te lnet, SNMP /RMON an d Web-bas ed inte rface • Spanning Tree Pr otocol f or redund ant netw ork conne ctions • VLAN support for 256 groups, port -based or wi th 80 2.1Q VLAN ta gging • Qualit ...

  • SMC Networks 1000 - page 25

    2-1 C HAPTER 2 N ETWORK P LANNING Introduction to Switching A netw ork switch al lows simul taneous t ransmiss ion of mult iple pack ets via no n-crossb ar switching. This me ans that i t can part iti on a networ k more efficient ly than bridges or routers . The s witch h as, there fore, been r ecogni zed as o ne of the mo st imp ortant build ing b ...

  • SMC Networks 1000 - page 26

    N ETWORK P LANNIN G 2-2 Sample Applications The Ti gerSwtich 1000 is desi gned t o conso lidate yo ur net work core pr oviding hi gh-ban dwidth con nection s between wor kgrou p switc hes and ser ver farms. Some typical app licatio ns are de scribe d in this sect ion. Backbone Consolidation The Ti gerSwtic h 1000 can consol idate a switc hed net wo ...

  • SMC Networks 1000 - page 27

    N ETWORK P LANNIN G 2-3 Making VLAN Connections VLANs c an be based on port gr oups, or each data fr ame can be expl icit ly tagg ed to ide ntify th e VLA N grou p it belo ngs to . When using po rt-base d VLANs, po rts can eith er be assign ed to one specifi c group or to all groups. Port-b ased VLANs ar e suitable for small netw orks. A sing le sw ...

  • SMC Networks 1000 - page 28

    N ETWORK P LANNIN G 2-4 Connectivity Rules When a dding hu bs (re peate rs) to your netwo rk, plea se follow the conne ctivit y rules l isted b elow for Et her net an d Fast Eth ern et. However , note that becau se swit ches brea k up the path for connec ted dev ices in to sep arate col lision d omains, you should not includ e the s witch o r conne ...

  • SMC Networks 1000 - page 29

    N ETWORK P LANNIN G 2-5 100 Mbps Fast Ethernet Collision Domain SMC 3-2 Rule for Class II Repeaters SMC 2-1 Rule for Class I Repeaters Maximum 100BASE-TX Network D iameter Using Repeat ers Maximum Fast Ethernet Cable Distance Between any two PCs or other stations in the same 100BASE-TX collision domain, there may be: • up to 3 link segments and ? ...

  • SMC Networks 1000 - page 30

    N ETWORK P LANNIN G 2-6 10 Mbps Ethernet Collision Domain SMC 5-4-3 Rule Maximum Cable Length Application Notes 1. Full-d uplex operation on ly appli es to point-t o-poin t access , such as when a switch is attached to a workstation, server or another switch. 2. For net work app lications that act ually re quire r outing, such as when int erconnec ...

  • SMC Networks 1000 - page 31

    3-1 C HAPTER 3 I NSTALLING THE S WI TCH Selecting a Site TigerS witch 1000 units can be m ounted in a standard 19-inch equi pment rack or on a fl at surface . Be su re to follo w the guidel ines below when choosing a location. ◆ The site should: • be at th e center of all the de vice s you want to li nk and ne ar a power outlet. • be able to ...

  • SMC Networks 1000 - page 32

    I NSTAL LING THE S WIT CH 3-2 Equipment Checklist After unp acking the TigerSwitch 1000, check the con tents to be sure you hav e received all the component s. Then, before beginn ing the i nstallation , be sure you have al l other n ecessary instal lation eq uipmen t. Package Contents ◆ TigerSwit ch 1000 (SM C8606T) uni t ◆ Four adhes ive f oo ...

  • SMC Networks 1000 - page 33

    I NSTAL LING THE S WIT CH 3-3 Mounting A Tiger Switch 1 000 unit can be mo unted in a standa rd 19-in ch equi pment ra ck or on a de sktop or shelf. Mo untin g instruc tions fo r each type of si te follow. Rack Mounting Befo re rack mounting the switch, pay par ticular attentio n to th e following factors: ◆ Temperature: Since the temperatu re wi ...

  • SMC Networks 1000 - page 34

    I NSTAL LING THE S WIT CH 3-4 Figure 3-1. Attac hing th e Bracke ts 2. Mount t he devic e in the rack, us ing four rack-mou nting sc rews (not provided). Figure 3 -2. Instal ling the S witch in a Rack 3. If in stalling a sing le swit ch only, turn to “ Connec ting to a Powe r Source ” at the end of this chapter . ...

  • SMC Networks 1000 - page 35

    I NSTAL LING THE S WIT CH 3-5 4. If insta llin g multip le swit ches , mount th em in the rack, one below the oth er , in any or der . 5. If al so instal ling R PUs, mou nt them in the r ack belo w the other devic es. Desktop or Shelf Mounting 1. Att ach the four adhesi ve feet to the bott om of the fir st switc h. Figure 3-3. Attaching the Adhesiv ...

  • SMC Networks 1000 - page 36

    I NSTAL LING THE S WIT CH 3-6 Installing a GBIC Transceiver The t wo slots on th e switc h front panel are for i nstalli ng opti onal GBIC tran sceive rs. The GBIC slo ts suppor t the foll owing transcei vers: ◆ 1000 BASE- SX ◆ 1000 BASE-LX The 100 0BASE-SX GB IC tran sceive rs provid e one sho rt-wavel ength (850 nm ) Gigabit port th at can be ...

  • SMC Networks 1000 - page 37

    I NSTAL LING THE S WIT CH 3-7 Connecting to a Power Source T o connec t a device to a pow er sour ce: 1. In sert th e power cable pl ug dir ectly in to the receptacle loca ted at the back of the devi ce. Figure 3-4. Powe r Rece ptacle 2. Plug t he othe r end o f the cable in to a gr ounded, 3 -pin so cket. Note: For I nternational use, you may need ...

  • SMC Networks 1000 - page 38

    I NSTAL LING THE S WIT CH 3-8 ...

  • SMC Networks 1000 - page 39

    4-1 C HAPTER 4 M AKIN G N ETWORK C ONNECTIONS Connecting Network Devices The Ti gerSwi tch 10 00 is de signed to connect to IEE E 802.3ab complian t dev ices. For mo st appli c atio ns, the Ti gerS witch 10 00 would be co nnected to oth er switche s in th e network bac kbone. I t may als o be co nnected direct ly to Gig abit Eth ernet net work car ...

  • SMC Networks 1000 - page 40

    M AKING N ETWORK C ONNE CTIONS 4-2 Connecting to 100 0BASE-T Devices The R J-45 port s on t he TigerS witch 100 0 operate at 10 Mbps, 100 Mbps, and 1000 Mb ps, full and half d uplex, wit h suppor t for auto- negot iatio n of spee d, dupl ex mo de and f low cont rol. Y ou ca n connec t any RJ- 45 port on the s witch to any serv er or work station, o ...

  • SMC Networks 1000 - page 41

    M AKING N ETWORK C ONNEC TIO NS 4-3 Note: For 1000 Mbps ope ratio n, all f our wir e pairs in the c able m ust be conn ected . 1000BA SE-T p orts suppo rt the Au to MDI/ MDI-X feature, which means that at any operating speed (10, 100, o r 1000 Mb ps), eit her str aight -throu gh or cr ossove r cables can be us ed to c onnect to any serve r, works t ...

  • SMC Networks 1000 - page 42

    M AKING N ETWORK C ONNE CTIONS 4-4 All the SC-typ e ports operat e at 1000 Mbps with su pport for auto-ne g oti ation of dup lex mode (full /half) and flow co ntrol. Al so note the maximum l ength for 1000BASE-SX and 100 0BASE-LX fiber optic cable d epends o n the c ore siz e and the rati ng of the cable , as shown i n the fo llowing t able. Maximu ...

  • SMC Networks 1000 - page 43

    A-1 A PPENDIX A T ROUBLESHOOTING Diagnosing Switch Indicators Power and Cooling Problems If the pow er indic ator doe s not tur n on whe n the powe r cord is plugged in, you may have a p roblem wi th the power outlet , power cord, or internal power supply. Howeve r , if the un it powers o ff after run ning for a while, check for loo se power c onne ...

  • SMC Networks 1000 - page 44

    T R OUBLESHOOTI NG A-2 on the unit ar e unobst ructed and ru nning pri or to shutdown . If you st ill cann ot iso late the problem, then t he inte rnal power supply may be defe ctive. In this case, co ntact SMC Technical Support fo r assistance. Installation V eri fy that all s ystem comp onents have been pr operly ins talled. If one or m ore compo ...

  • SMC Networks 1000 - page 45

    B-1 A PPENDIX B C ABLES Specificati ons Cable Types and Specifications Cable Type Max. Length Connector 1000BASE-T Cat. 5, 5e 100-ohm UTP 100 m (328 ft) RJ-45 Maximum 1000BASE-SX Gigabit Ethernet Cable Length Fiber Size Fiber Bandwidth Maximum Cable Length 62.5/ 125 micr on 160 MHz /km 2-220 m (7-722 ft) 200 MHz /km 2-275 m (7-902 ft) 50/12 5 micro ...

  • SMC Networks 1000 - page 46

    C ABLES B-2 Twisted-Pair Cable and Pin Assignments Caution: DO NOT plug a ph one jack connec tor into any RJ-4 5 port . Use only t wisted- pair cab les with RJ-45 c onnecto rs that con form with FCC s tandards. The RJ- 45 ports on the switch support 10 00, 100 and 10 Mbps Ethernet o peration, with auto -negotiat ion of flow cont rol. Caution: E a c ...

  • SMC Networks 1000 - page 47

    C ABLE S B-3 Note that for 1000 BASE-T oper ation, all four pairs of wires are used for bot h transmit and receive. Pin MDI Signal Name MDI-X Signal Name 1 Transmit Data plus (TD1+) Transmit Data plus (TD2 +) 2 Receive Data m inus (RD 1-) Receive Data minus (RD2-) 3 Transmit Data plus (TD2+) Transmit Data plus (TD1+) 4 Transmit Data plus (TD3+) Tra ...

  • SMC Networks 1000 - page 48

    C ABLES B-4 1000BASE-T Cable Requirements All Categor y 5 UTP cables that are used for 100BASE-T X connec tions sh ould also work for 1000 BASE-T , providin g that all four wire pairs are connec ted. Howev er , it is rec ommended t hat for all cr itical co nnectio ns, or any new c able ins tallation s, Cate gory 5e (enhance d Cate gory 5 ) cable s ...

  • SMC Networks 1000 - page 49

    C ABLE S B-5 Console Port Pin Assignments T h e D B - 9 s e r i a l p o r t o n t h e s w i t c h ’ s re ar pan el is used to conn ect to the s witch for out-o f-band con sole c onfiguratio n. The on-boar d menu -drive n config uratio n progr am can be ac cessed f rom a ter mina l or a PC r unning a te r minal emul ation pr ogram. Th e pin ass ig ...

  • SMC Networks 1000 - page 50

    C ABLES B-6 Console Port to 9-Pin COM Port on PC Console Port to 25-Pin DTE Port on PC Switch ’ s 9-Pin Seria l Port CCITT Signal PC ’ s 9-Pin COM P ort 1 DCD ----------- DCD ------------ 1 2 RXD <--------- TXD ------------ 3 3 TXD ----------- RXD ----------> 2 4 DTR ----------- DSR ----------> 6 5 SGND ----------- SGND ---------- 5 6 ...

  • SMC Networks 1000 - page 51

    C-1 A PPENDIX C S PECIFICATIONS Physical Characteristics Ports 6 RJ-4 5 ports 2 GBIC slots Network Inter face RJ-45 conne ctor , 100-ohm C ategory 5 or 5e UTP or STP cabl e (using all fou r wire pairs) Buf fer Ar chitectur e 2 Mbyte s per port Aggreg ate B andw idth 16 Gbps Switching Dat abase 12K MA C addr ess en tries LEDs System : Power , RPU, D ...

  • SMC Networks 1000 - page 52

    S PECI FICA TIONS C-2 Humidity Operating : 5% to 95% Power Suppl y Inter nal, auto-rang ing tr ansfor mer: 100 to 240 V AC, 50 t o 60 Hz Redundan t DC input Power Consumption 70 W a tts maximum Heat Di ssipati on 239 BTU/h r maximu m Maximu m Curr ent 0.5A @ 110V AC 0.7A @ 240V AC Switch Features Spanning T ree Protocol Broadcast Stor m Suppr essio ...

  • SMC Networks 1000 - page 53

    S PECIFICATIO NS C-3 Management Features In-Band Management T elnet, W eb-base d HTTP , or SNM P manager Out-of-Band Management RS-2 32 DB-9 consol e port Softwar e Loading TFTP in- band or XModem out- of-band MIB S upport MIB II (RFC 1213), Bri dge MIB (RFC 1493), Ethernet-Like MIB (RFC 1643), RMON MIB (RFC 1 757), SMC ’ s private MI B RMON Supp ...

  • SMC Networks 1000 - page 54

    S PECI FICA TIONS C-4 Compliances CE Mar k Emissions FCC Class A Indust ry Ca nada Class A EN55022 (CISP R 22) Class A VCCI Cl ass A EN 61000- 3-2/3 C-Tick - AS/NZS 3548 (1995) Clas s A Immunity EN 61 000-4 -2/3/4/6 /8/10 /11 Safety CSA/N RTL (UL1950, CSA 22.2.95 0) TUV/GS(EN 60950) Warranty Limited lifetime ...

  • SMC Networks 1000 - page 55

    D-1 A PPENDIX D O RDERING I NFORMATION * Also available in models for Continental Europe and the UK. TigerSwitch 1000 Products and Accessories Product Number Description SMC8606T 6-port Gigabit Ethernet switch with two GBIC slots SMCRPU150W* Redundant Power Unit with cables, supports one device ...

  • SMC Networks 1000 - page 56

    O RDE RIN G I NFOR MATI ON D-2 ...

  • SMC Networks 1000 - page 57

    Glossary-1 G LOSSARY 10BAS E-T IEEE 80 2.3 spe cification for 1 0 Mbps Et hernet over two pair s of Cate gory 3, 4, or 5 UT P cable.. 100BASE-TX IEEE 80 2.3u specifi cation fo r 100 M bps Fast Ethernet ov er two pairs of Categ ory 5 UT P cable. 1000BAS E-T IEEE 80 2.3ab specifi cation fo r Gigab it Ethe rnet over two pairs of Cate gory 5, 5e 100-oh ...

  • SMC Networks 1000 - page 58

    G LOSSA RY Glossary-2 Class I Repeater Fast Ethernet repeater t hat is princip ally use d to connect differen t physic al signalin g systems (e.g., 100BASE- TX, 100BASE -FX) and that h as an int ernal delay s uch t hat only one repeater of th is type can res ide wit hin a sin gle colli sion domain when maximum c able leng ths are us ed. Class II Re ...

  • SMC Networks 1000 - page 59

    G LOSSAR Y Glossary-3 Ethernet A net work com municat ion sy stem develope d and standard ized by DEC, Int el, and Xer ox, using b aseband tr ansmissio n, CSMA/C D acces s, logi cal b us topolo gy, and coaxi al cable. T he suc cessor I EEE 802.3 s tandard provides for integ ration int o the OSI model and exten ds the physical laye r and media with ...

  • SMC Networks 1000 - page 60

    G LOSSA RY Glossary-4 IEEE 802.3u Defines CSMA/CD acce ss method and physical laye r specific ations for 100 BASE-TX Fas t Ethernet . IEEE 802.3x Defin es Ethe rnet frame s tart/st op requ ests and timers used fo r flow c ontrol on full- duplex links. IEEE 802.3z Defines CSMA/CD acce ss method and physical laye r specific ations for 100 0BASE G iga ...

  • SMC Networks 1000 - page 61

    G LOSSAR Y Glossary-5 Local Area Network (LAN) A group of intercon necte d compute r and supp ort de vices. Media Access Control (MAC) A por tion of the net workin g protoc ol that governs access t o th e transm ission medium , faci litati ng the exc hange of data be tween networ k nodes. MIB An acro nym for Ma nageme nt Inf ormat ion Bas e. It is ...

  • SMC Networks 1000 - page 62

    G LOSSA RY Glossary-6 Simple Network M anagement Protocol (SNMP) An app lication protocol offer ing net work manag ement se rvices in the In ternet s uite of p rotocols . Spanning Tree Algorithm (STA) A techn ology t hat che cks your n etwork fo r any loo ps. A loop ca n often occur in complic ated n etwork sy stem s or system s with redundan t lin ...

  • SMC Networks 1000 - page 63

    G LOSSAR Y Glossary-7 Virtual LAN (VLAN) A V irtual LAN is a collecti on of netwo rk nodes t hat sh are the same collis ion domain regardle ss of their physic al location or connecti on point i n the networ k. A VLAN serve s as a logical work group wi th no phy sical barr iers, allo wing use rs to share inf ormation and resour ces as t hough loc at ...

  • SMC Networks 1000 - page 64

    G LOSSA RY Glossary-8 ...

  • SMC Networks 1000 - page 65

    Index-1 Numerics 10 Mbps connectivity rules 2-6 100 Mbps conn ectivit y rule s 2- 5 1000BASE-LX fiber cable lengths 2 -4 1000BASE-SX fiber cable lengths 2 -4 1000BASE-SX connections 4-2 1000BASE-SX ports 1-2 1000BASE-T cable lengths 2-4 A accessories, ordering D -1 address table size C -1 adhesive feet, attaching 3-5 air flow requirements 3-1 appli ...

  • SMC Networks 1000 - page 66

    I NDEX Index-2 I IEEE 802.3x flow control 1-2 IEEE 802.3z devices, conecting to 4-1 IEEE 802.3z Gigabit Ethernet 1-7 indicators, LED 1-3 installation desktop or shelf mounting 3-5 port connections 4-2 power r equire ments 3 -1 problem s A-2 rack mounting 3-3 RPUs in racks 3 -5 site requirements 3 -1 L laser safety iv , 4-3 LED indicators ACT 1-4 Po ...

  • SMC Networks 1000 - page 67

    I NDEX Index-3 routing applications 2-6 RPUs connecting 3-7 installing in a rack 3-5 installing on a desktop 3-5 RS-232 s eria l port 1-4 rubber foot pads, attaching 3-5 S safety compliance iv sample applications 2-2 screws for rack mounting 3-2 serial port 1-4 site selelction 3-1 SNMP agent 1-4 Spanning Tree Protocol 1-5 , 2-3 specifications compl ...

  • SMC Networks 1000 - page 68

    I NDEX Index-4 ...

  • SMC Networks 1000 - page 69

    ...

  • SMC Networks 1000 - page 70

    6 Hughes Irvine, C A 9261 8 Phone: (949 ) 707-2400 FOR TECHNICAL SUPPOR T , CALL: From U.S.A. an d Canada (2 4 hours, 7 days a we ek) (800) SMC-4-YOU; (94 9) 707-2400; (949) 707-2460 (Fax) From Europe (8:00 AM - 5:30 PM UK Greenwich Mean T ime) 44 (0) 1188 7487 40; 44 (0) 1189 74 8741 (Fax) INTERNET E-mail a ddresses: techsupp ort@smc.c om europea ...

Manufacturer SMC Networks Category Switch

Documents that we receive from a manufacturer of a SMC Networks 1000 can be divided into several groups. They are, among others:
- SMC Networks technical drawings
- 1000 manuals
- SMC Networks product data sheets
- information booklets
- or energy labels SMC Networks 1000
All of them are important, but the most important information from the point of view of use of the device are in the user manual SMC Networks 1000.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals SMC Networks 1000, service manual, brief instructions and user manuals SMC Networks 1000. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product SMC Networks 1000.

A complete manual for the device SMC Networks 1000, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use SMC Networks 1000 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of SMC Networks 1000.

A complete SMC Networks manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual SMC Networks 1000 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the SMC Networks 1000, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the SMC Networks 1000, that we can find in the current document
3. Tips how to use the basic functions of the device SMC Networks 1000 - which should help us in our first steps of using SMC Networks 1000
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with SMC Networks 1000
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of SMC Networks 1000 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning SMC Networks 1000?

Use the form below

If you did not solve your problem by using a manual SMC Networks 1000, ask a question using the form below. If a user had a similar problem with SMC Networks 1000 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)