Manual Icom IC-208H

96 pages 3.17 mb
Download

Go to site of 96

Summary
  • Icom IC-208H - page 1

    INSTRUCTION MANUAL i208H VHF/UHF FM TRANSCEIVER This device complies with Part 15 of the FCC rules. Operation is sub- ject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. ...

  • Icom IC-208H - page 2

    i FOREWORD Thank you for purchasing this Icom product. The IC-208H VHF / UHF FM TRANSCEIVER is designed and built with Icom’s state of the art technology and craftsmanship. With proper care, this product should provide you with years of trouble-free operation. We want to take a couple of moments of your time to thank you for making your IC-208H y ...

  • Icom IC-208H - page 3

    R W ARNING RF EXPOSURE! This device emits Radio Frequency (RF) energy . Extreme caution should be observed when operating this device. If you have any questions regarding RF expo- sure and safety standards please refer to the Federal Communica- tions Commission Office of Engineering and T echnology’s report on Evaluating Compliance with FCC Guid ...

  • Icom IC-208H - page 4

    iii T ABLE OF CONTENTS SUPPLIED ACCESSORIES q DC power cable (3 m) ………………………………………1 w Mobile mounting bracket …………………………………1 e Microphone (HM-133)* ……………………………………1 r Fuse (20 A) …………………………………………………1 t Mounting screws, nuts and w ...

  • Icom IC-208H - page 5

    iv 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ■ One-touch PTT function ............................................................... 18 ■ Audio mute function ..................................................................... 18 4 REPEA TER OPERA TION ......................................................... 19–25 ■ General ...................... ...

  • Icom IC-208H - page 6

    I QUICK REFERENCE GUIDE ■ Installation D Installation methods • Single body installation • The supplied mounting bracket (or optional MB-17A) can be used for the main unit installation. • Remote installation • The supplied OPC-600/R SEP ARA TION CABLE can be used for remote installation. • Optional OPC-601/R SEP ARA TION CABLE (7 m; 23 ...

  • Icom IC-208H - page 7

    II QUICK REFERENCE GUIDE D Location Select a location which can support the weight of the trans- ceiver and does not interfere with driving. We recommend the locations shown in the diagram below . NEVER place the transceiver or remote controller where nor- mal operation of the vehicle may be hindered or where it could cause bodily injury . NEVER pl ...

  • Icom IC-208H - page 8

    III QUICK REFERENCE GUIDE D Microphone connection Connect the supplied microphone as illustrated below . D Separation cable connection Using the supplied separation cable (3.5 m; 1 1.5 ft) or the op- tional separation cable (7 m; 23 ft) the controller can be sep- arated from the main unit, doubling as a remote controller . q Detach the controller a ...

  • Icom IC-208H - page 9

    IV QUICK REFERENCE GUIDE D Optional MB-58 installation The optional MB-58 REMOTE CONTROLLER BRACKET is avail- able for separate installation. q Drill 2 or 4 holes where the bracket is to be installed. • Approx. 4 mm ( 1 ⁄ 8 ″ ) when using nuts; approx. 1–2 mm ( 1 ⁄ 16 ″ ) when using self-tapping screws. w Insert the supplied screws, bol ...

  • Icom IC-208H - page 10

    V D Battery connection ☞ R W ARNING NEVER remove the fuse holders from the DC power cable. ☞ NEVER connect the transceiver directly to a 24 V battery . ☞ DO NOT use the cigarette lighter socket for power con- nections. (See p. 5 for details) Attach a rubber grommet when passing the DC power cable through a metal plate to prevent a short circu ...

  • Icom IC-208H - page 11

    VI QUICK REFERENCE GUIDE D Antenna installation • Antenna location T o obtain maximum performance from the transceiver , select a high-quality antenna and mount it in a good location. A non- radial antenna should be used when using a magnetic mount. • Antenna connector The antenna uses a PL-259 connector . • PL-259 CONNECTOR q Slide the coupl ...

  • Icom IC-208H - page 12

    VII QUICK REFERENCE GUIDE ■ Y our fi rst contact Now that you have your IC-208H installed in your car or shack, you are probably excited to get on the air . We would like to take you through a few basic operation steps to make your first “On The Air” an enjoyable experience. 1. T urning ON the transceiver Before powering up your IC-208H, yo ...

  • Icom IC-208H - page 13

    VIII QUICK REFERENCE GUIDE 3. T une the frequency The tuning dial will allow you to dial in the frequency you want to operate. Pages 12 and 13 will instruct you on how to set the tuning speed. Using the HM-133 Y ou can directly enter the frequency with the HM-133 keypad for the main band. [EXAMPLE]: Setting frequency to 145.3625 MHz. Push Push Push ...

  • Icom IC-208H - page 14

    IX QUICK REFERENCE GUIDE ■ Repeater operation 1. Setting duplex Push [BAND] to select the frequency band. Push [LOW•DUP] for 1 sec. once or twice to select minus du- plex or plus duplex. • The USA version has an auto repeater function, therefore, setting duplex is not required. 2. Repeater tone Push [TONE•T -SCAN] several times until “T? ...

  • Icom IC-208H - page 15

    X QUICK REFERENCE GUIDE Quick reference guide ■ Programming memory channels The IC-208H has a total of 512 memory channels (including 10 scan edges and 2 call channels) for storing often used op - erating frequency , repeater settings, etc. 1. Setting a frequency In VFO mode, set the desired operating frequency with re- peater , tone and tuning s ...

  • Icom IC-208H - page 16

    ■ Front panel — controller q SET • LOCK SWITCH [SET • LOCK] ➥ Enters set mode when pushed. (p. 56) ➥ Switches the lock function ON and OFF when pushed for 1 sec. (p. 14) w TUNING DIAL [DIAL] Selects the operating frequency (p. 12), memory channel (p. 26), the setting of the set mode item and the scanning direction (p. 41). e VOLUME CONT ...

  • Icom IC-208H - page 17

    2 1 P ANEL DESCRIPTION 1 y SQUELCH CONTROL [SQL] V aries the squelch level. (p. 15) • The RF attenuator activates and increases the attenuation when rotated clockwise to the center position and further . (p. 16) u MONITOR • DTMF SWITCH [MONI • DTMF] ➥ Push to switch the monitor function ON and OFF . (p. 15) ➥ T urns DTMF memory encoder ON ...

  • Icom IC-208H - page 18

    3 1 P ANEL DESCRIPTION ■ Function display q TRANSMIT INDICA TOR ➥ Appears while transmitting. (p. 17) ➥ Blinks while transmitting with the one-touch PTT func- tion. (p. 18) w DUPLEX INDICA TORS (p. 20) “DUP” appears when plus duplex, “DUP –” appears when minus duplex (repeater) operation is selected. e TONE INDICA TORS ➥ “T” a ...

  • Icom IC-208H - page 19

    4 1 P ANEL DESCRIPTION 1 r NARROW MODE INDICA TOR (p. 65) Appears when the FM/AM narrow mode is selected. Narrow mode is available with USA version only . t AM INDICA TOR (p. 65) Appears when AM mode is selected. y SQUELCH A TTENUA TOR INDICA TOR (p. 16) Appears when the squelch attenuator function is activated. • The attenuator can be switched O ...

  • Icom IC-208H - page 20

    5 1 P ANEL DESCRIPTION ■ Rear Panel q DA T A SOCKET [DA T A] Connects a TNC (T erminal Node Controller), etc. for data communications. • See p. 6 for connection information. w EXTERNAL SPEAKER JACK [SP] Connects an 8 Ω speaker . • Audio output power is more than 2.0 W . e COOLING F AN Rotates while transmitting. Also rotates while receiving ...

  • Icom IC-208H - page 21

    6 1 P ANEL DESCRIPTION 1 D DA T A JACK PIN ASSIGNMENT q DA T A IN Input terminal for data transmit. See p. 63 for details on how to toggle data speed between 1200 (AFSK) and 9600 bps (G3RUH, GMSK). w GND Common ground for DA T A IN, DA T A OUT and AF OUT . e PTT P PTT terminal for packet operation only . Connect ground to transmit data. r DA T A OU ...

  • Icom IC-208H - page 22

    7 1 P ANEL DESCRIPTION ■ Microphone (HM-133*) q VFO/LOCK SWITCH [VFO/LOCK] ➥ Push to select VFO mode. (p. 1 1) ➥ Push for 1 sec. to switch the lock function ON and OFF . (p. 14) w PTT SWITCH ➥ Push and hold to transmit; release to receive. ➥ Switches between transmitting and receiving while the one-touch PTT function is in use. (p. 18) e ...

  • Icom IC-208H - page 23

    8 1 P ANEL DESCRIPTION 1 ■ Microphone keypad KEY FUNCTION SECONDAR Y FUNCTION ( +key) OTHER FUNCTIONS Switches between opening and closing the squelch. (p. 15) Starts and stops scanning. (p. 41) Starts and stops priority watch. (p. 47) Selects high output power . (p. 17) Selects mid. output power . (p. 17) Selects low output power (p. 17) Selects ...

  • Icom IC-208H - page 24

    9 1 P ANEL DESCRIPTION ➥ Cancels frequency entry . (p. 12) ➥ Cancels the scan or priority watch. (pgs. 41, 47) ➥ Exit set mode. (p. 56) ➥ Enters set mode (p. 56) ➥ Advances the set mode selection order after entering set mode. (p. 56) ➥ Sets the keypad for numeral input. (p. 12) ➥ Reverses the set mode selection order after entering s ...

  • Icom IC-208H - page 25

    10 1 P ANEL DESCRIPTION 1 ■ Optional Microphones (HM-1 18N/TN/T AN) q PTT SWITCH Push and hold to transmit; release to receive. w UP/DOWN SWITCHES [UP]/[DN] ➥ Push either switch to change operating frequency , memory channel, set mode setting, etc. (pgs. 12, 26, 56) ➥ Push either switch for 1 sec. to start scanning. (p. 41) e UP/DN LOCK SWITC ...

  • Icom IC-208H - page 26

    11 SETTING A FREQUENCY 2 ■ Preparation D T urning power ON/OFF ➥ Push [PWR] for 1 sec. to turn power ON and OFF . D Operating frequency band selection The IC-208H has 2 m and 70 cm bands for transmission and reception. In addition, extra frequency bands 127, 220, 350, 500 and 900 MHz bands are available for wide-band receiver capability (except ...

  • Icom IC-208H - page 27

    12 2 SETTING A FREQUENCY 2 ■ Using the tuning dial q Rotate [DIAL] to set the frequency . • If VFO mode is not selected, push [V/MHz•SCAN] to select VFO mode. • The frequency changes in the selected tuning steps. (p. 13) w T o change the frequency in 1 MHz (10 MHz for some versions) steps, push [V/MHz•SCAN], then rotate [DIAL]. • Pushin ...

  • Icom IC-208H - page 28

    13 2 SETTING A FREQUENCY ■ T uning step selection [ T uning steps are the minimum frequency change increments when you rotate [DIAL] or push [ Y ]/[ Z ] on the microphone. Independent tuning step for each frequency bands can be set for individual tuning convenience. The following tuning steps are available. • 5 kHz • 10 kHz • 12.5 kHz • 1 ...

  • Icom IC-208H - page 29

    14 2 SETTING A FREQUENCY 2 ■ Lock functions T o prevent accidental frequency changes and unnecessary function access, use the lock function. The transceiver has 2 different lock functions. D Frequency lock This function locks [DIAL] and switches electronically and can be used together with the microphone lock function. ➥ Push [SET•LOCK] for 1 ...

  • Icom IC-208H - page 30

    15 BASIC OPERA TION 3 ■ Receiving q Set the audio level. ➥ Push [MONI•DTMF] to open the squelch. ➥ Rotate [VOL] to adjust the audio level. ➥ Push [MONI•DTMF] to close the squelch. w Set the squelch level. ➥ Rotate [SQL] fully counterclockwise in advance, then ro- tate [SQL] clockwise until the noise just disappears. • When interfere ...

  • Icom IC-208H - page 31

    16 3 BASIC OPERA TION 3 ■ Squelch attenuator The transceiver has an RF attenuator related to the squelch level setting. Approx. 10 dB attenuation is obtained at maxi- mum setting. The squelch attenuator allows you to set a minimum signal level needed to open the squelch. The attenuator function can be deactivated in initial set mode. ➥ Rotate [ ...

  • Icom IC-208H - page 32

    17 3 BASIC OPERA TION ■ T ransmitting ☞ NOTE: T o prevent interference, listen on the channel be- fore transmitting by pushing [MONI•DTMF] on the front panel or [ MONI 1(BANK)] on the microphone. q Select the frequency band. (p. 1 1) w Set the operating frequency . (pgs. 1 1, 12) • Select output power if desired. See section at right for de ...

  • Icom IC-208H - page 33

    ■ One-touch PTT function The PTT switch can be operated as a one-touch PTT switch (each push toggles between transmit/receive). Using this function you can transmit without pushing and holding the PTT switch. T o prevent accidental, continuous transmission with this func- tion, the transceiver has a time-out timer . See p. 62 for de- tails. z Pus ...

  • Icom IC-208H - page 34

    19 REPEA TER OPERA TION 4 Repeaters allow you to extend the operational range of your radio because a repeater has much higher output power than the typical transceiver . Normally , a repeater has independent frequencies for each receiver and transmitter . A subaudible tone may also be required to access a repeater . Reference amateur radio hand bo ...

  • Icom IC-208H - page 35

    20 4 REPEA TER OPERA TION 4 ■ Accessing a repeater q Set the receive frequency (repeater output frequency). (pgs. 1 1, 12) w Push [LOW•DUP] for 1 sec. one or two times, to select minus duplex or plus duplex. • “DUP–” or “DUP” appears to indicate the transmit frequency for minus shift or plus shift, respectively . • When the auto r ...

  • Icom IC-208H - page 36

    21 4 REPEA TER OPERA TION z Set the receive frequency (repeater output fre- quency). (pgs. 1 1, 12) x Push [ DUP – 7(TONE)] to select minus duplex; push [ DUP + 8(TSQL S )] to select plus duplex. c Push [FUNC] then [ DUP – 7(TONE)] to turn ON the subaudible tone encoder according to re- peater requirements. • Refer to p. 22 for the tone frequ ...

  • Icom IC-208H - page 37

    22 4 REPEA TER OPERA TION 4 ■ Subaudible tones [ (Encoder function) D Subaudible tones q Select the frequency band, mode/channel you wish to set the subaudible tones, such as VFO mode or memory/call channel. w Push [SET•LOCK] to enter set mode. e Push [SET•LOCK] or [DUP•MONI] several times until “T” and “rT” appear; or until “T SQ ...

  • Icom IC-208H - page 38

    D DTMF tones ➥ Push [DTMF-S], then push the keys of the de- sired DTMF digits. • The function indicator lights green. • 0–9, A–D, M (E) and #(F) are available. • When “d” is displayed in place of the 100 MHz digit, cancel the DTMF memory encoder in advance. (p. 50) • Push [DTMF-S] again to return the keypad to nor- mal function co ...

  • Icom IC-208H - page 39

    24 4 REPEA TER OPERA TION 4 ■ Offset frequency [ When communicating through a repeater , the transmit fre- quency is shifted from the receive frequency by an amount determined by the offset frequency . Independent offset frequencies can be set for each operating frequency . q Push [BAND] to select the desired frequency band. w Select the desired ...

  • Icom IC-208H - page 40

    ■ Auto repeater (U.S.A. version only) The USA version automatically activates the repeater settings (DUP– or DUP+ and tone encoder ON/OFF) when the operating frequency falls within the general repeater output frequency range and inactivate them when outside of the range. D Setting the auto repeater function ON/OFF q Push [PWR] to turn power OFF ...

  • Icom IC-208H - page 41

    26 5 MEMOR Y OPERA TION 4 5 ■ General description The transceiver has 512 memory channels including 10 scan edge memory channels (5 pairs), and 2 call channels. Each of these channels can be individually programmed with operat- ing frequency (pgs. 1 1, 12), duplex direction (p. 21) and off- set (p. 24), subaudible tone encoder or tone squelch and ...

  • Icom IC-208H - page 42

    27 5 MEMORY OPERA TION ■ Programming a memory channel [EXAMPLE]: Programming 145.870 MHz into memory channel 20 (blank channel) via the controller . Push Rotate for setting frequency , etc. Push . Rotate Push for 1 sec. and continue to push ➠ Beep “ Beep Beep Beep “ “ “ “ “ Beep “ VFO settings, including the s ...

  • Icom IC-208H - page 43

    28 5 MEMORY OPERA TION 5 D Programming a memory channel via the microphone [EXAMPLE]: Programming 145.870 MHz into memory channel 20 (blank channel) via the microphone. Push 10 times Beep “ Beep “ Beep Beep Beep “ “ “ “ “ Push Push then Push then for 1 sec. and continue to push ➠ The microphone can also be used ...

  • Icom IC-208H - page 44

    29 5 MEMORY OPERA TION ■ Copying memory contents This function copies a memory channel’s contents to VFO (or another memory/call channel). This is useful when searching for signals around a memory channel frequency and for re- calling the offset frequency , subaudible tone frequency etc. D Memory/call ➪ VFO q Select the desired memory or call ...

  • Icom IC-208H - page 45

    30 5 MEMORY OPERA TION 5 D Memory/call ➪ memory/call q Select the memory/call channel to be transferred. ➥ Push [M/CALL•PRIO] several times to select memory mode or call channel, then rotate [DIAL] or push [BAND] to select the desired memory or call channel respec- tively . w Push [S.MW•MW] momentarily . •“ ! ” indicator and “-- -- ...

  • Icom IC-208H - page 46

    31 5 MEMORY OPERA TION ■ Programming channel names Each memory channel and the call channel can be pro - grammed with an alphanumeric channel name for easy recognition and can be indicated independently by channel. Names can be a maximum of 6 characters— see the table below for available characters. q Push [S.MW•MW] momentarily . •“ ! ” ...

  • Icom IC-208H - page 47

    32 5 MEMORY OPERA TION 5 Channel names can also be programmed via the mi- crophone. z Push [FUNC] then [ CLR A(MW)] momentarily . •“ ! ” and memory channel number blink. x Push [ Y ]/[ Z ] to select the memory/call channel to be as- signed memory names. c Push [BAND]. • Frequency readouts disappear and a cursor blinks. v Push [ Y ]/[ Z ] to ...

  • Icom IC-208H - page 48

    5 MEMORY OPERA TION 33 D D T o indicate the channel name [ The channel name indication can be set for independent memory channels. q Push [M/CALL•PRIO] to select the memory mode. w Rotate [DIAL] to select the desired memory channel to be indicated the channel name. e Push [SET•LOCK] to enter set mode. r Push [SET•LOCK] or [S.MW•MW] several ...

  • Icom IC-208H - page 49

    5 MEMORY OPERA TION 34 5 ■ Memory clearing Contents of programmed memories can be cleared (blanked), if desired. q Push [V/MHz•SCAN] to select VFO mode. w Push [S.MW•MW] momentarily . •“ ! ” indicator and the memory channel number blink. e Rotate [DIAL] to select the memory channel to be cleared. • Memory channels not yet programmed a ...

  • Icom IC-208H - page 50

    35 5 MEMORY OPERA TION ■ Memory bank selection The IC-208H has a total of 10 banks (A to J) . Regular memory channels, 1 to 500, are assigned into the desired bank for easy memory management. q Push [M/CALL•PRIO] several times to select memory mode, if desired. w Push [BAND] to select memory bank condition. • Bank’ s initial blinks e Rotate ...

  • Icom IC-208H - page 51

    36 5 MEMORY OPERA TION 5 ■ Memory bank setting [ q Push [M/CALL•PRIO] several times to select memory mode, then select the desired memory channel via [DIAL]. w Push [SET•LOCK] to enter set mode. e Push [SET•LOCK] or [S.MW•MW] several times until “BAK” appears. r Rotate [DIAL] to select the desired bank to be set. t Push [V/MHz•SCAN] ...

  • Icom IC-208H - page 52

    37 5 MEMORY OPERA TION ■ T ransferring bank contents [ Contents of programmed memory banks can be cleared or transferred to another bank. INFORMA TION: Even if the memory bank contents are cleared, the memory channel contents still remain pro- grammed. q Select the desired bank contents to be transferred or erased. ➥ Push [M/CALL•PRIO] severa ...

  • Icom IC-208H - page 53

    38 6 CALL CHANNEL OPERA TION 5 6 ■ Call channel selection Call channel is pre-programmed memory channel that can be accessed by simply pushing call channel button. ➥ Push [M/CALL•PRIO] several times to select the call chan- nel mode then push [BAND] to select the desired call channel. • “C1” or “C2” appears instead of memory channel ...

  • Icom IC-208H - page 54

    39 6 CALL CHANNEL OPERA TION ■ Programming a call channel Operating frequency , duplex information, subaudible tone in- formation (tone encoder or tone squelch ON/OFF and its fre- quency) can be programmed into the call channel. q Set the desired frequency in VFO mode. ➥ Push [V/MHz•SCAN] to select VFO mode. ➥ Set the frequency using [DIAL] ...

  • Icom IC-208H - page 55

    40 7 SCAN OPERA TION 6 7 ■ Scan types Scanning searches for signals automatically and makes it easier to locate new stations for contact or listening purposes. There are 3 scan types and 4 resume conditions to suit your operating needs. BAND SCAN (p. 41) Repeatedly scans all frequen- cies over the entire band. Used as the simplest scan without an ...

  • Icom IC-208H - page 56

    41 7 SCAN OPERA TION ■ Scan start/stop D Preparation Scan resume condition (p. 45); program the scan edges (pgs. 42, 43); program 2 or more memory channels (pgs. 27, 28); set skip settings (p. 44), if desired. D Operation q Select VFO mode for full/programmed scan with [V/MHz•SCAN]; or memory mode for memory scan with [M/CALL•PRIO]. • Selec ...

  • Icom IC-208H - page 57

    42 7 SCAN OPERA TION 7 ■ Scan edges programming Scan edges can be programmed in the same manner as memory channels. Scan edges are programmed into scan edges, 1A/1B to 5A/5B, in memory channels. q Set the edge frequency of the desired frequency range in VFO mode: ➥ Set the frequency using [DIAL]. ➥ Set other data (e.g. repeater settings, etc. ...

  • Icom IC-208H - page 58

    43 7 SCAN OPERA TION D Programming scan edges via microphone z Set the desired frequency in VFO mode. ➥ Push [VFO/LOCK] to select VFO mode. ➥ Set the frequency via the keypad or [ Y ]/[ Z ]. x Push [FUNC] then [ CLR A(MW)] momentarily . c Push [ Y ] or [ Z ] to select scan edge channels, 1A, 2A, 3A, 4A or 5A. v Push [FUNC], then push [ CLR A(MW ...

  • Icom IC-208H - page 59

    44 7 SCAN OPERA TION 7 ■ Skip channel setting [ The memory skip function speeds up scanning by checking only those memory channels not set as skip channels. Set skip channels as follows. q Select a memory channel: ➥ Push [M/CALL•PRIO] to select memory mode. ➥ Rotate [DIAL] to select the desired channel to be a skip channel. w Push [SET•LO ...

  • Icom IC-208H - page 60

    45 7 SCAN OPERA TION ■ Scan resume condition [ The scan resume condition can be selected as timer or pause scan. The selected resume condition is also used for priority watch. (p. 47) q Push [SET•LOCK] to enter set mode. w Push [SET•LOCK] or [S.MW•MW] several times until “SCT” or “SCP” appears as shown above. • When “d” is dis ...

  • Icom IC-208H - page 61

    46 8 PRIORITY W A TCH 7 8 ■ Priority watch types Priority watch checks for signals on a VFO frequency every 5 sec. while operating in memory mode. The transceiver has 3 priority watch types to suit your needs. Y ou can also trans- mit on the VFO frequency while the priority watch operates. The watch resumes according to the selected scan resume c ...

  • Icom IC-208H - page 62

    47 8 PRIORITY W A TCH ■ Priority watch operation q Select VFO mode; then, set an operating frequency . w Set the watching channel(s). For memory channel watch: Select the desired memory channel. For memory scan watch: Select memory mode; then, push [V/MHz•SCAN] for 1 sec. to start memory scan. For call channel watch: Select the desired call cha ...

  • Icom IC-208H - page 63

    48 9 DTMF MEMOR Y ENCODER 8 9 ■ Programming a DTMF code DTMF tones are used for autopatching, controlling other equipment, etc. The transceiver has 16 DTMF memory chan- nels (D0–DF) for storage of often-used DTMF codes of up to 24 digits. q Push [MONI•DTMF] for 1 sec. to turn the DTMF encoder ON. • “d” appears in place of 100 MHz digit. ...

  • Icom IC-208H - page 64

    49 9 DTMF MEMORY ENCODER D Programming a DTMF code — via microphone z Push [FUNC] then [ LOW 6(DTMF)] to turn the DTMF encoder ON. • “d” appears in place of 100 MHz digit. x Push [ SET B(D-OFF)] to enter the DTMF memory programming condition. c Push [ Y ] or [ Z ] to select the desired DTMF memory channel. v Push the desired digit keys. • ...

  • Icom IC-208H - page 65

    50 9 DTMF MEMORY ENCODER 9 ■ T ransmitting a DTMF code D Automatic transmission (DTMF memory) q Push [MONI•DTMF] for 1 sec. to turn the DTMF memory encoder ON. • “d” appears in place of 100 MHz digit. w Push [SET•LOCK] to enter DTMF memory programming condition. e Rotate [DIAL] to select the desired DTMF memory chan- nel. r Push [PTT] t ...

  • Icom IC-208H - page 66

    51 9 DTMF MEMORY ENCODER D Manual transmission z Deactivate the DTMF memory encoder by pushing [FUNC] then [ SET B(D-OFF)]. x Push [DTMF-S] to turn the DTMF direct selec- tion ON. • The function indicator (microphone) lights green. c Push one of “0” to “9” and “A” to “F” keys mo- mentarily , then push the desired DTMF keys, 0–9 ...

  • Icom IC-208H - page 67

    52 10 POCKET BEEP AND TONE SQUELCH 9 10 ■ Pocket beep operation This function uses subaudible tones for calling and can be used as a “common pager” to inform you that someone has called while you were away from the transceiver . D W aiting for a call from a speci fi c station q Set the operating frequency . w Push [SET•LOCK] to enter set m ...

  • Icom IC-208H - page 68

    53 10 POCKET BEEP AND TONE SQUELCH z Set the operating frequency . x Program the CTCSS tone frequency or DTCS code in set mode. ➥ Push [ SET B(D-OFF)] to enter set mode. ➥ Push [ SET B(D-OFF)] or [ ENT C(T -OFF)] several times until “CT” for tone squelch or “DT” for DTCS squelch appears. • “T SQL” blinks when tone squelch (“CT? ...

  • Icom IC-208H - page 69

    54 10 POCKET BEEP AND TONE SQUELCH 10 ■ T one/DTCS squelch operation The tone or DTCS squelch opens only when receiving a sig- nal with the same pre-programmed subaudible tone or DTCS code, respectively . q Set the operating frequency . w Program the CTCSS tone frequency or DTCS code in set mode. • See p. 52 for programming details. e Push [TON ...

  • Icom IC-208H - page 70

    55 10 POCKET BEEP AND TONE SQUELCH ■ T one scan By monitoring a signal that is being operated with pocket beep, tone or DTCS squelch function, you can determine the tone frequency or DTCS code necessary to open a squelch. q Set the desired operating frequency or memory channel to be checked for a tone frequency or code. w Push [TONE•T -SCAN] se ...

  • Icom IC-208H - page 71

    56 11 OTHER FUNCTIONS 10 11 ■ Set mode • Set mode operation q Push [SET•LOCK] to enter the set mode. w Push [SET•LOCK] or [S.MW•MW] to select the desired item. e Rotate [DIAL] to select the condition or value. r Push [MONI•DTMF] to exit set mode. • Set mode items z Push [ SET B(D-OFF)] to enter set mode. x Push [ SET B(D-OFF)] or [ EN ...

  • Icom IC-208H - page 72

    57 11 OTHER FUNCTIONS D D Display dimmer Adjust to suit lighting conditions. The levels 1 (dark) to 8 (bright: default) are available. D D Display color The display color can be set to amber (default), yellow or green. D D Mic lock function Sets the supplied HM-133’s (optional for some versions) key lock function from ON and OFF (default). D D Re ...

  • Icom IC-208H - page 73

    58 11 OTHER FUNCTIONS 11 D D DTCS code Sets DTCS code (both encoder and decoder) for DTCS squelch operation. T otal of 104 codes are available. (default: 023) D D DTCS polarity Sets DTCS polarities for transmission and reception from “NN,” “NR,” “RN” and “RR.” (default: NN) D D Offset frequency Sets the duplex offset frequency withi ...

  • Icom IC-208H - page 74

    59 11 OTHER FUNCTIONS D D Scan resume timer Selects scan resume timer from SCT -15 (default), SCT -10, SCT -5 and SCP-2. • SCT -15/10/5 : Scan pauses for 15/10/5 sec., then re- sumes. • SCP-2 : P ause on a signal until signal disap- pears, then resumes 2 sec. after the sig- nal disappears. D D Channel skip setting Sets channel skip setting from ...

  • Icom IC-208H - page 75

    60 11 OTHER FUNCTIONS 11 D D Program scan skip setting Sets the program scan skip setting from ON and OFF for VFO scan operation, such as programmed scan. This item appears when set mode is accessed from VFO mode only . D D Weather alert function T urns weather alert function ON and OFF . D D Memory bank link function Sets the memory bank link func ...

  • Icom IC-208H - page 76

    61 11 OTHER FUNCTIONS ■ Initial set mode The initial set mode is accessed at power ON and al- lows you to set seldom-changed settings. In this way , you can “customize” transceiver operations to suit your preference and operating style. • Initial set mode items D D Entering initial set mode q While pushing [SET•LOCK], push [PWR] for 1 sec ...

  • Icom IC-208H - page 77

    62 11 OTHER FUNCTIONS 11 D D Key-touch beep The key-touch beep can be turned OFF for silent operation. D D Time-out timer T o prevent accidental prolonged transmission, etc., the trans- ceiver has a time-out timer . This function cuts a transmission OFF after 1–30 min. of continuous transmission. This timer can be cancelled. • TOT -OF : The tim ...

  • Icom IC-208H - page 78

    63 11 OTHER FUNCTIONS D D Cooling fan control Selects the cooling fan control condition from Auto and ON. • Auto (A T) : The fan rotates during transmit and for 2 min. after transmission, or when the internal tem- perature of the transceiver exceeds the pre- set value until the temperature drops. • ON (ON) : The fan continuously rotates. D D Da ...

  • Icom IC-208H - page 79

    64 11 OTHER FUNCTIONS 11 D D Active band Selects the frequency selecting condition via [DIAL] or [ Y ]/[ Z ] on the microphone from all (AL) and single (SI). • All (AL) : The operating frequency can be selected continuously . • Single (SI) : The operating frequency can be selected within the current band. Pushing [BAND] for 1 sec. then tuning d ...

  • Icom IC-208H - page 80

    65 11 OTHER FUNCTIONS ■ AM/FM narrow mode The IC-208H has AM mode reception and FM narrow mode is available. T ypically , AM mode is used for the air band (1 18–135.995 MHz). q Select the desired frequency band in VFO mode, or the de- sired memory channel. w Push [BAND] for 1 sec. to select AM/FM narrow mode as desired. • “NAR” (FM narrow ...

  • Icom IC-208H - page 81

    66 11 OTHER FUNCTIONS 11 ■ W eather channel operation (USA version only) D D Weather channel selection q Push [M/CALL•PRIO] several times to select weather channel group. w Rotate [DIAL] to select the desired weather channel. e Push [M/CALL•PRIO] to select memory mode, or push [V/MHz•SCAN] to select VFO mode. D D Weather alert function NOAA ...

  • Icom IC-208H - page 82

    67 11 OTHER FUNCTIONS ■ Microphone keys The supplied HM-133’s (optional for some versions) [F-1] and [F-2] keys memorize the transceiver conditions. The [UP]/[DN] keys of the standard or an optional microphone (other than the HM-133) can be assigned functions like the function keys on the transceiver ’s front panel. D D [UP]/[DN] keys on a mi ...

  • Icom IC-208H - page 83

    68 11 OTHER FUNCTIONS 11 ■ Partial reset If you want to initialize the operating conditions (VFO fre - quency , VFO settings, set mode contents) without clearing the memory contents. ➥ While pushing [V/MHz•SCAN] and [SET•LOCK], push [PWR] for 1 sec. to partially reset. ■ All reset The function display may occasionally display erroneous in ...

  • Icom IC-208H - page 84

    69 11 OTHER FUNCTIONS ■ Data cloning Cloning allows you to quickly and easily transfer the pro - grammed contents from one transceiver to another; or data from a personal computer to a transceiver using the optional CS-208 CLONING SOFTWARE . D Cloning between transceivers q Connect the OPC-474 cloning cable to [SP] jack of the master and sub-tran ...

  • Icom IC-208H - page 85

    70 11 OTHER FUNCTIONS 11 D Cloning using a personal computer Data can be cloned to and from a personal computer (Mi- crosoft ® Windows ® 98/2000/Me/XP) using the optional CS-208 CLONING SOFTWARE and the optional cloning cable OPC-478U (USB type) or OPC-478 (RS-232C type). Consult the CS-208 CLONING SOFTWARE HELP file for details. D Cloning error ...

  • Icom IC-208H - page 86

    71 11 OTHER FUNCTIONS ■ Packet operation D Data speed For packet operation, the transceiver can be set to one of two data speeds: 1200 bps or 9600 bps. q While pushing [SET•LOCK], push [PWR] for 1 sec. to enter initial set mode. w Push [SET•LOCK] or [S.MW•MW] to select the ‘BPS’ item. e Rotate [DIAL] to select the desired data speed. r ...

  • Icom IC-208H - page 87

    72 11 OTHER FUNCTIONS 11 • Read the instructions supplied with your TNC carefully before attempting packet operation with the transceiver . • Pin t AF OUT is for 1200 bps operation only . This pin cannot be used for 9600 bps operation. • Over modulation may degrade signal quality . If you find that many transmissions are failing, re-adjust t ...

  • Icom IC-208H - page 88

    73 11 OTHER FUNCTIONS D 9600 bps high speed packet operation The transceiver supports 2 modes of 9600 bps packet opera- tion: G3RUH and GMSK. q Connect the transceiver and a TNC as illustrated below . w G3RUH mode can handle 16 kinds of modulated wave forms in order to maintain a communication link. e Set transmit delay on the TNC. r Adjust the TNC ...

  • Icom IC-208H - page 89

    74 11 OTHER FUNCTIONS 11 D Adjusting the transmit signal output from the TNC When setting data transmission speed to 9600 bps, the data signal coming from the TNC is applied exclusively to the in- ternal limiter circuitry to automatically maintain band width. NEVER apply data levels from the TNC of over the accept - able level below , otherwise the ...

  • Icom IC-208H - page 90

    75 MAINTENANCE 12 PROBLEM POSSIBLE CAUSE SOLUTION REF . ■ T roubleshooting If your transceiver seems to be malfunctioning, please check the following points before sending it to a service center . Does not turn on. No sound comes from the speaker . Sensitivity is low and only strong signals are audible. No contact possible with another station. R ...

  • Icom IC-208H - page 91

    76 12 MAINTENANCE 12 ■ Fuse replacement If the fuse blows or the transceiver stops functioning, find the source of the problem if possible, and replace the damaged fuse with a new , rated one (FGB 20 A) as shown at right. 20 A fuse PROBLEM POSSIBLE CAUSE SOLUTION REF . Some memory channels cannot be selected via the tuning dial. Scan does not op ...

  • Icom IC-208H - page 92

    77 SPECIFICA TIONS AND OPTIONS 13 ■ Speci fi cations D D GENERAL • Frequency coverage : USA Rx 1 18.000–173.995 MHz* 1 , 230.000–549.995 MHz* 2 , 810.000–999.990 MHz* 3 Tx 144–148 MHz, 440–450 MHz Australia, Asia Rx 1 18.000–173.995 MHz* 1 , 230.000–549.995 MHz* 2 , 810.000–999.990 MHz Tx 144–148 MHz, 430–440 MHz Korea Tx/R ...

  • Icom IC-208H - page 93

    78 13 SPECIFICA TIONS AND OPTIONS 13 ■ Options HM-133 REMOTE - CONTROL MICROPHONE Wired remote control microphone with key backlight. Same as that supplied with the transceiver . HM-1 18T AN/TN DTMF MICROPHONE HM-1 18N HAND MICROPHONE HS-62 FLEXIBLE MOBILE MICROPHONE + HS-15SB SWITCH BOX + OPC-589 ADAPTOR CABLE For all-round mobile operation. OPC ...

  • Icom IC-208H - page 94

    79 MODE ARRANGEMENT 14 Key-touch beep (p. 62) Time-out timer (p. 62) DTMF speed (p. 64) Narrow transmission (p. 64) SET MODE DTMF MEMORY CLONE MODE CALL CHANNEL (p. 38) WEATHER CHANNEL (p. 66) (USA version only) BANK CHANNEL MEMORY MODE (p. 26) VFO mode (p. 11) INITIAL SET MODE Display dimmer (p. 57) Display color (p. 57) Bank link function ‡ (p. ...

  • Icom IC-208H - page 95

    80 14 MODE ARRANGEMENT 14 Auto repeater (p. 62) (USA version only) Auto power off (p. 62) Cooling fan (p. 63) Data speed (p. 63) Squelch delay (p. 63) Microphone sensitivity (p. 63) Squelch attenuator (p. 63) Active band (p. 64) Repeater tone frequency (p. 57) Tone squelch frequency (p. 57) DTCS code (p. 58) DTCS polarity (p. 58) Offset frequency ( ...

  • Icom IC-208H - page 96

    1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003 Japan A-6265D-1EX Printed in Japan © 2003 Icom Inc. ...

Manufacturer Icom Category Marine Radio

Documents that we receive from a manufacturer of a Icom IC-208H can be divided into several groups. They are, among others:
- Icom technical drawings
- IC-208H manuals
- Icom product data sheets
- information booklets
- or energy labels Icom IC-208H
All of them are important, but the most important information from the point of view of use of the device are in the user manual Icom IC-208H.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Icom IC-208H, service manual, brief instructions and user manuals Icom IC-208H. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Icom IC-208H.

Similar manuals

A complete manual for the device Icom IC-208H, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Icom IC-208H by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Icom IC-208H.

A complete Icom manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Icom IC-208H - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Icom IC-208H, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Icom IC-208H, that we can find in the current document
3. Tips how to use the basic functions of the device Icom IC-208H - which should help us in our first steps of using Icom IC-208H
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Icom IC-208H
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Icom IC-208H in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Icom IC-208H?

Use the form below

If you did not solve your problem by using a manual Icom IC-208H, ask a question using the form below. If a user had a similar problem with Icom IC-208H it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)