Manual Kohler 10ERG

52 pages 1.54 mb
Download

Go to site of 52

Summary
  • Kohler 10ERG - page 1

    Commercial Mobile Generator Sets Model: 10ERG 13ERG 15ERG TP-6335 9/04 Installation ...

  • Kohler 10ERG - page 2

    ...

  • Kohler 10ERG - page 3

    T able of Conte nts Safet y Pr ecauti ons and I nstr uct ions I ......................................................... Secti on 1 Int r oducti on 1 ..................................................................... 1.1 Inst all ati on Standar ds 1 .................................................. 1.2 Gener ator Set Speci fi cati ons 1 ...... ...

  • Kohler 10ERG - page 4

    Notes ...

  • Kohler 10ERG - page 5

    Safety Precautions and Instructions I TP-6335 9/04 Safety Precautions and Instructions IMPORT ANT SAFETY INSTRUCTIONS. Electromechanical equipment, including generator sets, transfer switches, switchgear , and accessories, can cause bodily harm and pose life-threatening danger when improperly installed, operated, or maintained. T o prevent accident ...

  • Kohler 10ERG - page 6

    II Safety Precautions and Instructions TP-6335 9/04 Battery short circuits. Explosion can cause severe injury or death. Short circuits can cause bodily injury and/or equipment damage. Disconnect the battery before generator set installation or maintenance. Remove all jewelry before servicing the equipment. Use tools with insulated handles. Remove t ...

  • Kohler 10ERG - page 7

    Safety Precautions and Instructions III TP-6335 9/04 Fuel System Explosive fuel vapors. Can cause severe injury or death. Use extreme care when handling, storing, and using fuels. W ARNING The fuel system. Explosive fuel vapors can cause severe injury or death. V aporized fuels are highly explosive. Use extreme care when handling and storing fuels. ...

  • Kohler 10ERG - page 8

    IV Safety Precautions and Instructions TP-6335 9/04 Welding the generator set. Can cause severe electrical equipment damage. Before welding the generator set perform the following steps: (1) Remove the battery cables, negative ( - - ) lead first. (2) Disconnect all engine electronic control module (ECM) connectors. (3) Disconnect all generator set ...

  • Kohler 10ERG - page 9

    Safety Precautions and Instructions V TP-6335 9/04 Airborne particles. Can cause severe injury or blindness. Wear protective goggles and clothing when using power tools, hand tools, or compressed air . W ARNING Tightening the hardware. Flying projectiles can cause severe injury or death. Loose hardware can cause the hardware or pulley to release fr ...

  • Kohler 10ERG - page 10

    VI Safety Precautions and Instructions TP-6335 9/04 Notes ...

  • Kohler 10ERG - page 11

    1 Introduction TP-6335 9/04 Section 1 Introduction All information in this publication represents data available at the time of print. Kohler Co. reserves the right to change this literature and the products represented without incurring obligation. The safe and successful operation of a mobile power system depends primarily on the installation. Us ...

  • Kohler 10ERG - page 12

    2 Introduction TP-6335 9/04 Notes ...

  • Kohler 10ERG - page 13

    TP-6335 9/04 Location and Mounting 3 Section 2 Location and Mounting 2.1 General Considerations Consider the following items concerning the generator set and Section 2.2 for the proposed location. 1. Select a generator set having adequate capacity to handle the electrical load. 2. Design the fuel system to prevent fuel starvation of the main or gen ...

  • Kohler 10ERG - page 14

    4 Location and Mounting TP-6335 9/04 Notes ...

  • Kohler 10ERG - page 15

    TP-6335 9/04 Cooling System 5 Section 3 Cooling System 3.1 Air Requirements Air flow around the generator set is necessary for adequate cooling. See the current generator set specification sheet for air requirements. The air intake silencer/cleaner provides combustion air to the engine. See Figure 3-1 for allowable intake restriction. The engine/ge ...

  • Kohler 10ERG - page 16

    6 Cooling System TP-6335 9/04 Notes ...

  • Kohler 10ERG - page 17

    7 TP- 6335 9/04 Ex haust S ys tem 7 Secti on 4 E xhau st System Carbon m onoxide. Can cause severe nausea, f ainti ng, or death. The exhaust system must be leakpr oof and routi nely inspected. W ARNING Gener ator set oper ation. Carbon monoxi de can cause severe nausea, fai nting, or deat h. Carbon m onoxide is an odorl ess, color less, t astel ess ...

  • Kohler 10ERG - page 18

    TP- 6335 9/04 8 Ex haus t Sy st em 4.1 P lanni ng Caref ully plan t he gener ator exhaust syst em to ensure a sa fe, q uie t i ns tal l ati o n. V e ri fy th at the in sta ll ati on complies wit h all stat e and local requirement s and applicable artic les of the codes list ed at t he beginning of this m anual. 4.2 Clear ance Requi rem ents Kohler ...

  • Kohler 10ERG - page 19

    TP-6335 9/04 Fuel System 9 Section 5 Fuel System Explosive fuel vapors. Can cause severe injury or death. Use extreme care when handling, storing, and using fuels. W ARNING The fuel system. Explosive fuel vapors can cause severe injury or death. V aporized fuels are highly explosive. Use extreme care when handling and storing fuels. Store fuels in ...

  • Kohler 10ERG - page 20

    TP-6335 9/04 10 Fuel System 5.1.1 Fuel Lines Note: Keep fuel lines away from the exhaust system. Routing fuel lines. T ake care when routing the fuel line from the fuel tank to the generator set. Keep the fuel lines as short as possible but maintain adequate clearance from the exhaust system. Route the fuel lines along the frame or undercarriage— ...

  • Kohler 10ERG - page 21

    TP-6335 9/04 Fuel System 1 1 5.4 Fuel Pump Lift and Fuel Consumption See Figure 5-3 for the fuel pump lift capability . Consult the current generator set specification sheet for the generator set fuel consumption rates. Do not exceed 3 1/2 psi fuel pump pressure to the carburetor . Note: Fuel system alterations may adversely affect emissions levels ...

  • Kohler 10ERG - page 22

    TP-6335 9/04 12 Fuel System Notes ...

  • Kohler 10ERG - page 23

    TP-6335 9/04 Electrical System 13 Section 6 Electrical System Hazardous voltage. Can cause severe injury or death. Operate the generator set only when all guards and electrical enclosures a r ei np l a c e . Moving rotor . W ARNING Electrical backfeed to the utility . Hazardous backfeed voltage can cause severe injury or death. Connect the generato ...

  • Kohler 10ERG - page 24

    14 Electrical System TP-6335 9/04 Note: T ransfer switch. Use a triple-pole, double-throw transfer switch rated for the calculated load of the vehicle to transfer the load from one source to the other . Install a ground-fault circuit interrupter in the wiring system to protect all branch circuits. Note: AC load circuit protection. Protect the AC lo ...

  • Kohler 10ERG - page 25

    TP-6335 9/04 Electrical System 15 6.3 Circuit Protection The AC circuit breaker protects the generator set from extreme overload. The AC circuit breaker trips when it detects a fault in the output circuit. For application and selection information contact an authorized distributor/dealer . After correcting the fault, reset the AC circuit breaker by ...

  • Kohler 10ERG - page 26

    16 Electrical System TP-6335 9/04 6.3.2 Circuit Breaker Installation Note: Wire material. Use stranded copper for all wiring. Use wire gauges and insulation, conductor temperature ratings, sheath stripping, conductor support and protection, conductor terminals and splices, and overcurrent protection (circuit breakers, fuses) that conform to standar ...

  • Kohler 10ERG - page 27

    TP-6335 9/04 Electrical System 17 6.4 ADC 2100 Continuous Power Mode Jumper A jumper on connector P7 on the back of the controller causes the controller to remain powered at all times. Controllers are shipped from the factory with the jumper connected. Disconnecting the jumper causes the controller to automatically power down 48 hours after the gen ...

  • Kohler 10ERG - page 28

    18 Electrical System TP-6335 9/04 6.5 Battery and Connections Sulfuric acid in batteries. Can cause severe injury or death. Use protective goggles and clothes. Battery acid can cause permanent damage to eyes, burn skin, and eat holes in clothing. W ARNING Battery gases. Explosion can cause severe injury or death. Battery gases can cause an explosio ...

  • Kohler 10ERG - page 29

    TP-6335 9/04 Electrical System 19 -- + Battery Positive V ehicle Frame 12-V olt Battery Using the Same Battery as the V ehicle Engine N Battery Negative to V ehicle Frame Ground Strap V ehicle Frame -- + Battery Positive V ehicle Frame 12-V olt Battery Using a Separate Battery for the Generator Set N View A View B Figure 6-6 Battery Connection Deta ...

  • Kohler 10ERG - page 30

    20 Electrical System TP-6335 9/04 Notes ...

  • Kohler 10ERG - page 31

    Ins tallation D rawing 21 TP- 6335 9/04 Sec t ion 7 Inst a llat ion D ra wing ADV-6816A-A Figure 7- 1 Dimens ion Drawing, G asoline F uel Sy st em ...

  • Kohler 10ERG - page 32

    TP- 6335 9/04 22 Ins tallat ion Draw ing ADV-6816B-A Figure 7- 2 Dimens ion Drawing, LP F uel Sy st em ...

  • Kohler 10ERG - page 33

    Ins tallation D rawing 23 TP- 6335 9/04 ADV-6816C-A Figure 7- 3 Dimens ion Drawing, F loor T emplat e ...

  • Kohler 10ERG - page 34

    TP- 6335 9/04 24 Ins tallat ion Draw ing Notes ...

  • Kohler 10ERG - page 35

    TP-6335 9/04 Reconnection/Adjustments 25 Section 8 Reconnection/Adjustments Accidental starting. Can cause severe injury or death. Disconnect the battery cables before working on the generator set. Remove the negative ( - - ) lead first when disconnecting the battery . Reconnect the negative ( - - ) lead last when reconnecting the battery . W ARNIN ...

  • Kohler 10ERG - page 36

    26 Reconnection/Adjustments TP-6335 9/04 8.1 Four-Lead Reconnection The following drawings illustrate the reconnection of four-lead generator sets. In all cases, conform to the National Electrical Code (NEC). NOTICE V oltage reconnection. Affix a notice to the generator set after reconnecting the set to a voltage different from the voltage on the n ...

  • Kohler 10ERG - page 37

    TP-6335 9/04 Reconnection/Adjustments 27 200 - - 240-V olt Configurations The 200 - - 240-volt configuration does not use a jumper lead. If the unit was originally wired for straight 100 - - 120 volt, 3 wire, remove the jumper lead (see Figure 8-1 for location). 43 2 1 Stator Leads L0 GRD. L1 L0 (Neutral) Line Side Single-Pole Circuit Breaker Groun ...

  • Kohler 10ERG - page 38

    28 Reconnection/Adjustments TP-6335 9/04 8.2 Advanced Digital Control (ADC 2100) The model 10/13/15ERG generator sets use the ADC 2100. The ADC 2100 uses password-protected menus for generator output adjustments and controller configuration. This section contains instructions for using the ADC’s password-protected menus to check and adjust the ge ...

  • Kohler 10ERG - page 39

    TP-6335 9/04 Reconnection/Adjustments 29 8.2.3 Adjusting the V oltage, Gain, and V olts/Hz After setting the system voltage, check the output voltage and adjust, if necessary , using the following procedures. Follow the instructions in Figure 8-6 to adjust the voltage, gain, and volts/Hz while the engine is running. An x in the Display column in Fi ...

  • Kohler 10ERG - page 40

    30 Reconnection/Adjustments TP-6335 9/04 TP6196 Move the generator set master switch to the RUN position. The generator set engine starts and the controller display shows the engine runtime hours. Display :* or or T o raise or lower the voltage in large increments (approximately 5 - - 7 volts per step). T o enter fine voltage adjustment mode. T o r ...

  • Kohler 10ERG - page 41

    TP-6335 9/04 Reconnection/Adjustments 31 D i s p l a y:* Continued from Figure 8 - 6: * x in the examples above denotes any number from 0 to 9. The actual values may vary from model-to-model. S A V E T o enter SA VE mode. Note: Be sure to save your settings before exiting the configuration mode. The controller reverts to the last saved settings whe ...

  • Kohler 10ERG - page 42

    32 Reconnection/Adjustments TP-6335 9/04 8.2.5 Controller Configuration The controller configuration for each generator model is set at the factory and should not normally require changes. The controller ’s configuration mode allows adjustment of the system parameters listed in this section. Use the instructions in this section to check the confi ...

  • Kohler 10ERG - page 43

    TP-6335 9/04 Reconnection/Adjustments 33 Parameter Setting Definition Unit’s system voltage and frequency Uu01 Single phase, 60 Hz, 120/240 V AC Unit configuration Uc02 Mobile generator set Engine type Ec03 10/13/15ERG Engine data input types ( N i i k ) Ed00 All digital inputs g p y p (No magnetic pick-up) Ed01 Digital: Low coolant level and low ...

  • Kohler 10ERG - page 44

    34 Reconnection/Adjustments TP-6335 9/04 W ait about 5 seconds until the display shows the program version number . (The number may be different than the one shown here.) Hold the Select button: or T o set the voltage/frequency setting for 60 Hz models. T o step to the next parameter , unit configuration Uc. or T o set the unit configuration settin ...

  • Kohler 10ERG - page 45

    TP-6335 9/04 Reconnection/Adjustments 35 or T o set the engine data input type. T o enter battery voltage selection mode. or T o toggle between 12 and 24 VDC. T o enter communications selection mode. or T o set the communications parameter . T o enter SA VE mode. Go to Figure 8 -1 1. E d 0 x Pressing the up arrow key at the Adnc display (See Figure ...

  • Kohler 10ERG - page 46

    36 Reconnection/Adjustments TP-6335 9/04 Notes ...

  • Kohler 10ERG - page 47

    TP-6335 9/04 Appendix A-1 Appendix A Generator S election and W attage Requirements General W attage Requirements Consider the total wattage requirements (lights, motors, appliances) when selecting a generator set, or when sizing wattage usage in which available space and construction limit the size of the generator set. Motor Loads When figuring g ...

  • Kohler 10ERG - page 48

    TP-6335 9/04 A-2 Appendix Appendix B Abbreviations The following list contains abbreviations that may appear in this publication. A, amp ampere ABDC after bottom dead center AC alternating current A/D analog to digital ADC analog to digital converter adj. adjust, adjustment ADV advertising dimensional drawing AHWT anticipatory high water temperatur ...

  • Kohler 10ERG - page 49

    TP-6335 9/04 Appendix A-3 kg kilogram kg/cm 2 kilograms per square centimeter kgm kilogram-meter kg/m 3 kilograms per cubic meter kHz kilohertz kJ kilojoule km kilometer kOhm, k Ω kilo-ohm kPa kilopascal kph kilometers per hour kV kilovolt kV A kilovolt ampere kV AR kilovolt ampere reactive kW kilowatt kWh kilowatt-hour kWm kilowatt mechanical L ...

  • Kohler 10ERG - page 50

    ...

  • Kohler 10ERG - page 51

    ...

  • Kohler 10ERG - page 52

    E 2004 by Kohler Co. All rights reserved. TP-6335 9/04 KOHLER CO. Kohler , Wisconsin 53044 Phone 920-565-3381, Fax 920-459-1646 For the nearest sales/service outlet in the US and Canada, phone 1-800-544-2444 KohlerPowerSystems.com Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65)6264-6422, Fax (65)6264-64 ...

Manufacturer Kohler Category Portable Generator

Documents that we receive from a manufacturer of a Kohler 10ERG can be divided into several groups. They are, among others:
- Kohler technical drawings
- 10ERG manuals
- Kohler product data sheets
- information booklets
- or energy labels Kohler 10ERG
All of them are important, but the most important information from the point of view of use of the device are in the user manual Kohler 10ERG.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Kohler 10ERG, service manual, brief instructions and user manuals Kohler 10ERG. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Kohler 10ERG.

Similar manuals

A complete manual for the device Kohler 10ERG, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Kohler 10ERG by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Kohler 10ERG.

A complete Kohler manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Kohler 10ERG - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Kohler 10ERG, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Kohler 10ERG, that we can find in the current document
3. Tips how to use the basic functions of the device Kohler 10ERG - which should help us in our first steps of using Kohler 10ERG
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Kohler 10ERG
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Kohler 10ERG in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Kohler 10ERG?

Use the form below

If you did not solve your problem by using a manual Kohler 10ERG, ask a question using the form below. If a user had a similar problem with Kohler 10ERG it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)