    AM3Plus Access Controller (760) 438-7000 • FAX (760) 438-7043 USA & Canada (800) 421-1587 & (800) 392-0123 Toll Free FAX (800) 468-1340 www.linearcorp.com PRINTER’S INSTRUCTIONS: INSTR,INSTL,AM3PLUS - LINEAR P/N: 227542 A - INK: BLACK - MA TERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - FOLDING: ALBUM-FOLD - BINDING ...

  • Linear AM3Plus - page 2

    2 Contents Introduction The AM3Plus Access Controller is designed for use as a primary access control device f or gated communities, parking garages, offi ce buildings , apar tments, dormitories, hotels/motels, commercial buildings and recreational facilities . Housed in a lockab le, plastic enclosure, the AM3Plus f eatures a 2-digit LED display , ...

  • Linear AM3Plus - page 3

    3 Har dware Features ✓ FOUR FORM “C” (N.O. & N.C) RELAYS Each relay has 3-amp @ 24-volt rating with a status indicator and relay latching pushbutton ✓ FOUR REQUEST-TO-EXIT INPUTS Activates access device for exiting using a hardwired switch ✓ FOUR SENSING INPUTS For sensing door position to control door -ajar and alarm features, or for ...

  • Linear AM3Plus - page 4

    4 Accessor y Over view PBUS Accessories Sev eral compatible accessories are av ailable to connect to the two 6- wire communications “PBUS” inputs . Up to six PBUS accessories can be used with each AM3Plus unit. AM-RRR R emote Radio Receiv er For wireless tr ansmitters, connect the Model AM-RRR high-gain superheterodyne UHF receiver . The receiv ...

  • Linear AM3Plus - page 5

    5 Component Locations POWER INDICATOR RE S ET BUTTON ENTER BUTTON S TATU S /PROGRAM DI S PLAY ARROW BUTTON S S TATU S INDICATOR S RELAY INDICATOR S (4) RELAY LATCH BUTTON S (4) AM-MIO INTERFACE CONNECTOR (HIDDEN) POWER S WITCH TERMINAL BLOCK S TELEPHONE LINE CONNECTOR COM PORT CONNECTOR AM3PLU S ACCE SS CONTROLLER ...

  • Linear AM3Plus - page 6

    6 Wiring Diagram ELECTRIC DOOR S TRIKE DOOR S TRIKE POWER S UPPLY GATE OPERATOR OPEN GATE EXIT LOOP S EN S OR MAGNETIC DOOR LOCK DOOR LOCK POWER S UPPLY DOOR EXIT REQUE S T BUTTON "A" DOOR "B" S EN S E CONTACT GATE OPERATOR OPEN R S -2 3 2 PORT PHONE LINE EARTH GROUND S TAKE DOOR EXIT REQUE S T BUTTON "B" THIS WIRING E ...

  • Linear AM3Plus - page 7

    7 Impor tant Mounting Requir ements The AM3Plus Access Control System can be installed f or public or private use. The mounting requirements for remote k eypads will v ar y depending on the installation. Revie w the follo wing information before star ting the installation. Mounting Environment Consider the environmental f actors at the desired moun ...

  • Linear AM3Plus - page 8

    8 AM3Plus Mounting Standard Cabinet The AM3Plus cabinet is designed to be mounted directly to a wall or fl at surface . Wiring access for pow er, telephone , ear th ground, control output must be av ailable at the mounting location. For easier wiring, choose a well lit location. Wiring access for remote accessory cables must also be av ailable at ...

  • Linear AM3Plus - page 9

    9 Rela y Output Wiring Any of the f our relay outputs channels (A-D) can be used to control access devices on doors or gates . Door or Pedestrian Gate Control 1. Install a low v oltage electr ic door strike or magnetic lock as a locking de vice for the door or pedestrian gate. 2. Install the power supply or tr ansformer for the locking de vice. DO ...

  • Linear AM3Plus - page 10

    10 P ower, Bat ter y, & Gr ound Wiring Power Wiring ✦ NO TE: DO NO T APPL Y PO WER UNTIL THE IN S T ALLA TION I S COMPLETE. TURN MA S TER PO WER S WITCH OFF BEFORE WIRING. 1. Route two wires between the AM3Plus and the po wer transformer . • F or power wire runs up to 100 feet, use 18 A WG, 600-volt insulated wire. • F or power wire runs ...

  • Linear AM3Plus - page 11

    11 T elephone Wiring For prog ramming, the AM3Plus connects to a standard telephone line. ✦ NO TE: The optional Model ACM-1 modem is required f or telephone communications to the AM3Plus controller . Impor tant T elephone Wiring Tips • DO NO T ROUTE TELEPHONE AND AC WIRING INSIDE THE SAME CONDUIT . Route all telephone wires inside a dedicated c ...

  • Linear AM3Plus - page 12

    12 Wiegand Accessories The two AM3Plus Wiegand inputs (READER A & B) can connect to a large variety of 26, 30, and 31-bit Wiegand output accessories. The Wiegand format is a common standard f or access control equipment. A typical application would be to add s wipe card or proximity readers to the system. ✦ NO TE: Depending on the Wiegand acc ...

  • Linear AM3Plus - page 13

    13 Optional Net work Connections Linear’ s AM3Plus, AE1000Plus, & AE2000Plus Access Control Systems can be connected together in a network. A network will allow sharing programming and user inf or mation between the systems. Program each unit to a different netw or k Node Address (see P age 16). ✦ IMPORT ANT COMP A TIBILITY NOTE: Linear’ ...

  • Linear AM3Plus - page 14

    14 Optional Net work Connections (Continued) Network Confi guration for AccessBase2000 Programming If the system is going to be programmed using Linear’ s AccessBase2000 software, units comm unicate with each other on the network through RS-485 cable connections . AccessBase2000 does not suppor t unit-to-unit network communications through modem ...

  • Linear AM3Plus - page 15

    15 Optional Net work Connections (Continued) RS-485 Networ k Wiring Network wiring conforms to 3-wire RS-485 electr ical specifi cations. Units connected in the network can be wired using one unit as a “hub” or by wiring from one unit to the next in “daisy-chain” f ashion. See the fi gures for wiring options. • Use Belden 9925 or Carol ...

  • Linear AM3Plus - page 16

    16 Sys tem Contr ols Pushbuttons Refer to the fi gure f or the location of each of the eight pushbuttons. • UP button adds one to the v alue on the ST A TUS/PROGRAM display . • DO WN button subtracts one from v alue on the ST A TUS/PROGRAM displa y . Press with the UP button f or one second to enter Programming Mode. • ENTER button accepts t ...

  • Linear AM3Plus - page 17

    17 Sys tem Diagnos tics Sev eral indicators on the AM3Plus are f or monitor ing the system during operation. When calling f or technical assistance, Linear’ s T echnical Services Depar tment ma y ask the installer to use these indicators to diagnose the system. Indicators 15 LED indicators are on the AM3Plus. Refer to the fi gure for the locatio ...

  • Linear AM3Plus - page 18

    18 Specifi cations MECHANICAL Case dimensions: 11.5” W x 12.5” H x 3.5” D ELECTRICAL V oltage: 16-24 V olts AC or 12-24 V olts DC Current: 850 mA maximum @ 12 V olts DC Backup Battery: 12 V olt DC Outputs: Relay Channels A-D Form “C” 3 Amps @ 30 V olts maximum Inputs: Four normally closed door sense inputs Four normally open request-to-e ...

  • Linear AM3Plus - page 19

    19 Linear Limited W arrant y This Linear product is warranted against def ects in material and workmanship for tw enty-four (24) months. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’ s normal distr ibution channels . Linear does not warrant this product to consumers. Consumers should inquire from ...

  • Linear AM3Plus - page 20

    Copyright © 2007 Linear LLC 227542 A ...

Manufacturer Linear Category Mobility Aid

Documents that we receive from a manufacturer of a Linear AM3Plus can be divided into several groups. They are, among others:
- Linear technical drawings
- AM3Plus manuals
- Linear product data sheets
- information booklets
- or energy labels Linear AM3Plus
All of them are important, but the most important information from the point of view of use of the device are in the user manual Linear AM3Plus.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Linear AM3Plus, service manual, brief instructions and user manuals Linear AM3Plus. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Linear AM3Plus.

Similar manuals

A complete manual for the device Linear AM3Plus, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Linear AM3Plus by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Linear AM3Plus.

A complete Linear manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Linear AM3Plus - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Linear AM3Plus, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Linear AM3Plus, that we can find in the current document
3. Tips how to use the basic functions of the device Linear AM3Plus - which should help us in our first steps of using Linear AM3Plus
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Linear AM3Plus
5. FAQ - Frequently Asked Questions