Manual Weber 42376

16 pages 0.46 mb
Download

Go to site of 16

Summary
  • Weber 42376 - page 1

    BUILT-IN LP SIDE BURNER INST ALLA TION/ OWNER'S GUIDE 42376 US 01/10/06 LP YOU MUST READ THIS O WNERS GUIDE BEF ORE OPERA TING YOUR G A S GRILL  DANGER If you smell gas: 1. Shut off gas to the appliance. 2. Extinguish any open fl ames. 3. Open lid. 4. If odor continues, keep away from the appliance and immediately call your gas supplier or ...

  • Weber 42376 - page 2

    2  DANGERS &  W ARNINGS  DANGER Failure to follow the Dangers, W arnings and Cautions contained in this Owner ’s Manual may result in serious bodily injury or death, or in a fi re or an explosion causing damage to property .  W ARNINGS  Do not store a spare or disconnected liquid propane cylinder under or near this barbecue. ? ...

  • Weber 42376 - page 3

    3 STORA GE AND/ OR NONUSE • The gas must be turned of f at the liquid propane cylinder when the Weber ® gas barbecue is not in use. OPERA TING  W ARNING: Only use this barbecue outdoors in a well-ventilated area. Do not use in a garage, building, breezeway or any other enclosed area.  W ARNING: Y our Summit® Built-In gas barbecue shall no ...

  • Weber 42376 - page 4

    4 L OCA TING YOUR BUIL T -IN SIDE BURNER When determining a suitable location for your Built-In Side Burner installation, give attention to concerns such as exposure to wind, proximity to traffi c paths, and keeping any gas supply lines as short as possible. Never locate the Sum- mit ® Built-In Side Burner in a garage, breezeway , shed, under an ...

  • Weber 42376 - page 5

    5 MOUNTING THE SIDE BURNER Connect the corrugated gas line to the side burner valve located on the back right hand side of side burner . TEST CONNEC TIONS All connections and joints must be thoroughly tested for leaks in accordance with local codes and all listed procedures in the latest edition of ANSI Z223.1/NFP A 54. BUIL T -IN GAS LINE LOCA TIO ...

  • Weber 42376 - page 6

    6 TYPICAL BULK PROP ANE GAS SUPPL Y INST ALLA TION We recommend that this installation be done by a LICENSED professional. General Specifi cations for Piping Note - Contact your local municipality for building codes regulating outdoor gas grill installations. In absence of Local Codes, you must conform to the latest edition of the National Fuel Ga ...

  • Weber 42376 - page 7

    7 TYPICAL 20 LP PROP ANE GAS SUPPL Y INST ALLA TION We strongly recommend that you use the Summit ® Built-In T ank Cabinet (#21280) for installations using a 20 lb LP cylinder , mounted remotely in an “island” structure. The Summit ® Built-In T ank Cabinet is a CSA listed accessory for installing a remote mounted 20 lb LP cylinder , in an “ ...

  • Weber 42376 - page 8

    8 3). The minimum size of the ventilation hole (s) should not be less than 1/4 inch. d). The remote LP cylinder enclosure should be constructed with non- combustible materials. The remote LP cylinder enclosure should isolate the LP cylinder from the burner compartment, so that it provides shielding from radiation, be a fl ame barrier and provide p ...

  • Weber 42376 - page 9

    9 GAS INSTRUC TIONS FILL LIQUID PROP ANE CYLINDER T o fi ll, take the liquid propane cylinder and fi ller adapter to an R V center or look up gas-propane in the phone book for other sources of liquid propane gas.  W ARNING: We recommend that your liquid propane cylinder be fi lled at an authorized liquid propane gas dealer by a qualifi ed at ...

  • Weber 42376 - page 10

    10 T o Connect the hose to the cylinder: 3) Remove the plastic dust cover from the valve. 4) Screw the regulator coupling onto the tank valve, clockwise, or to the right. Hand-tighten only . Note: This connection tightens clockwise and will not allow gas to fl ow unless the connection is tight. The connection requires tightening by hand only .  ...

  • Weber 42376 - page 11

    11 Check: 3) “T” Connection-to-Hose connections. 4) The hose-to-Regulator connection.  W ARNING: If there is a leak at connections (2,3, or 4), turn OFF the gas. DO NOT OPERA TE THE GRILL. Contact Customer Service 1-800-446-1071. When leak checks are complete, turn gas supply OFF at the source and rinse connections with water . OPERA TING (2 ...

  • Weber 42376 - page 12

    12 LIGHTING THE SIDE BURNER. 1) Open the side burner lid. 2) Check that the side burner valve is turned OFF . (Push knob in and turn clockwise to ensure that it in the off position.)  W ARNING: The burner control knob must be in the OFF position before turning on the liquid propane cylinder valve. If it is not in the OFF position, when you turn ...

  • Weber 42376 - page 13

    13 CROSSOVER ® IGNITION S YSTEM OPERA TIONS If the Crossover ® ignition system fails to ignite the LEFT burner in a burner set, light the LEFT burner with a match. If the LEFT burner lights with a match, then check the Crossover ® ignition system. • Check that both ignition wires(1,2) are attached properly . • Check that the Crossover ® ign ...

  • Weber 42376 - page 14

    14 PROBLEM CHECK CURE Side Burner does not light. Is gas supply off? T urn supply on. Flame is low in HIGH position. Is the fuel hose bent or kinked? Straighten hose. Is LP fuel low or empty? Refi ll LP cylinder . The excess fl ow safety device, which is part of the barbecue to cylinder connection, may have activated. T o reset the excess fl ow ...

  • Weber 42376 - page 15

    15  A TTENTION: This product has been safety tested and is only certifi ed for use in a specifi c country . Refer to country designation located on outer carton. These parts may be gas carrying or gas burning components. Please contact Weber-Stephen Products Co., Customer Service Department for genuine Weber-Stephen Products Co. replacement pa ...

  • Weber 42376 - page 16

    ©2003 The following trademarks are registered in the name of W eber-Stephen Products Co., an Illinois corporation, located at 200 East Daniels Road, Palatine, Illinois 60067 U.S.A. Australia; Smokey Joe, Weber , Kettle Silhouette ® , Genesis, Austria; Kettle Silhouette ® , Smokey Joe, Weber , Benelux; Kettle Silhouette ® , Smokey Joe, Weber , C ...

Manufacturer Weber Category Burner

Documents that we receive from a manufacturer of a Weber 42376 can be divided into several groups. They are, among others:
- Weber technical drawings
- 42376 manuals
- Weber product data sheets
- information booklets
- or energy labels Weber 42376
All of them are important, but the most important information from the point of view of use of the device are in the user manual Weber 42376.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Weber 42376, service manual, brief instructions and user manuals Weber 42376. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Weber 42376.

Similar manuals

A complete manual for the device Weber 42376, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Weber 42376 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Weber 42376.

A complete Weber manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Weber 42376 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Weber 42376, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Weber 42376, that we can find in the current document
3. Tips how to use the basic functions of the device Weber 42376 - which should help us in our first steps of using Weber 42376
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Weber 42376
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Weber 42376 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Weber 42376?

Use the form below

If you did not solve your problem by using a manual Weber 42376, ask a question using the form below. If a user had a similar problem with Weber 42376 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)