    Installati on Manual Part Number 3-9000-765R evision D March 201 3 Da ni e l TM 3812 Liquid U ltrasonic Flo w Meter f or Direct or Re mo t e Mount Me t e r Elec tronics ...

  • Emerson 3812 - page 2

    ...

  • Emerson 3812 - page 3

    Da n i el c us t o m er s er v i ce Email • Customer S er vice: tech.ser vi ce@emer son process. com • Cust omer Support: daniel.cst.support@emerson.c om • Asia -Pacific: danielap .support@ emerson.com • Eur op e: Dani elE MA .C S T@ E mer so nP ro ces s.co m Location Te l e p h o n e n u m b e r Fa x n u m b e r Nor th America/Latin Americ ...

  • Emerson 3812 - page 4

    Sign al w ords and symbols Pay s pecial a tte ntion to the f ollowing signal wor ds, saf ety aler t symbols and stateme nts : Impor tant Impor tant is a state me nt the use r needs to know and conside r . Tip Tip provides information or suggestions fo r improved e fficie ncy or best results. Note Note is a “ gene ral by-the-way” conten t not es ...

  • Emerson 3812 - page 5

    Impor tant safet y instruc tions Daniel Me asure ment and Control, Inc. (D aniel) designs, manu factures and tests products to func tion within specific conditions. Becaus e these produc ts are sophisticated technical instruments, it is impor tant that the owner and oper ation personnel strictly adhere both to the inf ormation printed on the produc ...

  • Emerson 3812 - page 6

    Product O peration Personnel: • T o preve nt pe rsonal in jury , personne l must fol low all instructions of this manu al prior to and during operation of the pro duc t. • F ollow all warnings, cautions, and notices m arked on, and supplied with, this produc t. • V erif y t hat this is the correct instruc tion manual for your Daniel produc t. ...

  • Emerson 3812 - page 7

    Notic e THE CONTENTS OF THIS PUBLICA TION AR E PRESENTED FOR INFORMA TIONAL PURPOSE S ONL Y , AND WHILE E VERY EFFORT HAS B EEN MADE T O ENSURE THEIR ACCURA CY , THE Y ARE NOT T O BE C ONST RUED AS W ARRANTIES OR GU ARANTE ES , E XPRE SSED OR IMPLIED , RE GARDING THE PRODUCTS OR SERVICES DESCRIBED HEREIN OR THEIR USE OR APPLICAB ILIT Y . ALL SALE S ...

  • Emerson 3812 - page 8

    W arrant y and Limitations 1. LIMITED W ARRANT Y : Subject to the limitat ions c ontained in Section 2 here in, D aniel Meas ureme nt & Contr ol, Inc. ("D anie l") warran ts th at the li ce nsed firmw are embodi ed in the Goods will ex ecute the programming instru ction s provided by Danie l, and that the Goods manufactured by Daniel ...

  • Emerson 3812 - page 9

    Daniel 3812 Liquid Ultrasonic Flow Mete r Installation Manual Table of Contents 3-9000-765 Rev D March 2013 Table of Contents i Co ntents D aniel c ust omer se r vice ................................................................................... 3 • Sign al words and symbols ................................................................... ...

  • Emerson 3812 - page 10

    ii Table of Contents Table of Contents Daniel 3812 Liquid Ultr asonic Flow Meter Installation Manual March 2013 3-9000-765 Rev D 3.6 I/O connections ......................................................................................... 5 5 3.6.1 Frequency/Digital outputs ....................... ........... .............. ........... ............ ...

  • Emerson 3812 - page 11

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Installation Manual List of Tables 3-9000-765 Rev D March 2013 List of Tables i List o f T ables T able 1-1 Acronyms, abbreviations and definiti ons ........................ ........... .............. ........... .............. . 3 T able 1-2 Meter specifications .............. .......... ...

  • Emerson 3812 - page 12

    ii List of Tables List of Tables Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manu al Installation Manual March 2013 3-9000-765 Rev D ...

  • Emerson 3812 - page 13

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Installation Manual List of Figures 3-9000-765 Rev D March 2013 List of Figures iii List o f Figures Figure 1-1 Dan iel MeterLink download and r egistration ................ .............. ........... .............. ......... 6 Figure 1-2 Di rect mount electronic s assembl y with sp l it ...

  • Emerson 3812 - page 14

    iv List of Figures List of Figures Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manu al Installation Manual March 2013 3-9000-765 Rev D Figure 3-13 Clamped shroud security seals .................... ........... .............. .............. ........... ............. 67 Figure 3-14 Split shroud security seals .............. .............. . ...

  • Emerson 3812 - page 15

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 1: Introduction 3-9000-765 Rev D March 2013 Typical Applications 1 Sec tion 1: Introduc tion Danie l 3812 Liquid Ultra sonic Flow Mete rs ha v e direct mount or remote mount e lec tronic options and various con figurations that meet a broad range of cust omer requiremen ts. Each m ...

  • Emerson 3812 - page 16

    2 Features and benefits Section 1: Introduction Daniel 3812 Liquid Ultrasonic Flow Mete r Installation Manual March 2013 3-9000-765 Rev D 1.2 F eature s and benefits • Explosion-proof transmitte r electronics enclo sure with CPU Module, P owe r Supply , Intrinsic Safe t y Barrier Module • In trinsically safe transduc er electronics enclosure wi ...

  • Emerson 3812 - page 17

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 1: Introduction 3-9000-765 Rev D March 2013 Acronyms, abbreviati ons and definitions 3 1.3 Acron yms, abbreviations and definitions T able 1-1 Acronyms, abbr eviations and definitions Acronym or abbre viation Definition ° degree (angle) o C degrees ce lsius (te mperature unit) o ...

  • Emerson 3812 - page 18

    4 Acronyms, abbreviat ions and definitions Section 1: Introduction Daniel 3812 Liquid Ultrasonic Flow Mete r Installation Manual March 2013 3-9000-765 Rev D FOD O output that is use r con figurable as e ither a frequency or digital output HART® Communication Pro tocol Highway Addre ssable R emo te T ransducer communications pro toc ol hr hour (tim ...

  • Emerson 3812 - page 19

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 1: Introduction 3-9000-765 Rev D March 2013 Acronyms, abbreviati ons and definitions 5 PC Perso nal Com puter PFC periphe ral field c o nnection (board) P/N par t number PS powe r supply (board) psi pounds per square inch (pressure unit) psia pounds per square inch ab solute (pres ...

  • Emerson 3812 - page 20

    6 Daniel MeterLink software Section 1: Introduction Daniel 3812 Liquid Ultrasonic Flow Mete r Installation Manual March 2013 3-9000-765 Rev D 1.4 Daniel MeterLink sof t ware Danie l Mete rLink sof t ware has robust features for setting communications parameters, calibrating y our met er , collecting logs and re por ts and monitoring the meter he al ...

  • Emerson 3812 - page 21

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 1: Introduction 3-9000-765 Rev D March 2013 Daniel 3812 Liquid Ultrasonic Flow meter design 7 1.5 Daniel 3812 Liquid Ultrasonic Flow meter design TheDaniel 3812 Liquid Ultrasonic Flow Meter designs include a direct or remote mount electronics option and depending on the met er’s ...

  • Emerson 3812 - page 22

    8 Daniel 3812 Liquid Ultrasonic Flow meter design Section 1: Introduction Daniel 3812 Liquid Ultrasonic Flow Mete r Installation Manual March 2013 3-9000-765 Rev D Figure 1-3 Direct mount elec tronics with la tched single band shrouds and remote display A. E xplosion -proof transmitter enclosure (CPU Modu le, Po wer Supply , I.S. B arrier Board, B. ...

  • Emerson 3812 - page 23

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 1: Introduction 3-9000-765 Rev D March 2013 Daniel 3812 Liquid Ultrasonic Flow meter design 9 Figure 1-4 Direc t mount elec tronics with bolted single band shrouds and local display A. E xplosion -proof transmitter enclosure (CPU Modu le, Po wer Supply , I.S. B arrier Board, B. In ...

  • Emerson 3812 - page 24

    10 Daniel 3812 Liquid Ultrasonic Flow meter design Section 1: Introduction Daniel 3812 Liquid Ultrasonic Flow Mete r Installation Manual March 2013 3-9000-765 Rev D Figure 1-5 Direct mount elec tronics assembly with cl amped band shrouds A. E xplosion -proof transmitter enclosure (CPU Modu le, Po wer Supply , I.S. B arrier Board, B. Intrin sically- ...

  • Emerson 3812 - page 25

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 1: Introduction 3-9000-765 Rev D March 2013 Daniel 3812 Liquid Ultrasonic Flow meter design 11 Figure 1-6 Remot e mount elec tronics assembly with clamped band shrouds A. Explosion -proof transmitter encl osure (CPU Module, Pow e r Supply , I.S. Barrier Board, B. Intrinsi cally-sa ...

  • Emerson 3812 - page 26

    12 Daniel 3812 Liquid Ultrasonic Flow meter design Section 1: Introduction Daniel 3812 Liquid Ultrasonic Flow Mete r Installation Manual March 2013 3-9000-765 Rev D Figure 1-7 Remot e mount elec tron ic s assembly with split shrouds A. E xplosion -proof transmitter encl osure (CPU Modu le, P ower Supply , I.S. Barri er Board B. Intrin sically-safe ...

  • Emerson 3812 - page 27

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 1: Introduction 3-9000-765 Rev D March 2013 Daniel 3812 Liquid Ultrasonic Flow meter design 13 Figure 1-8 Optional local display and glass endcap The Daniel 3812 Liquid Ultrasonic Flow Meter is a two -path (four transduce rs) in -line meter de signed to me asure the d iff ere nce ...

  • Emerson 3812 - page 28

    14 Meter specifications Section 1: Introduction Daniel 3812 Liquid Ultrasonic Flow Mete r Installation Manual March 2013 3-9000-765 Rev D 1.6 M eter specificatio ns Consult your Daniel Sales and Se r vice represe ntative to e nsure you purcha se the correct c ompone nts and se als for your application. T able 1-2 Meter specifications Liquid Ultraso ...

  • Emerson 3812 - page 29

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 1: Introduction 3-9000-765 Rev D March 2013 Meter specifications 15 Electron ic specificatio ns Power Met e r • 10.4 V DC to 3 6 VDC measured at t he meter term inals 1 • 11 W maximum power consumption Serial cable • Belde n #9940 or e quivalen t (22 gauge) — Capacitance ( ...

  • Emerson 3812 - page 30

    16 Meter specifications Section 1: Introduction Daniel 3812 Liquid Ultrasonic Flow Mete r Installation Manual March 2013 3-9000-765 Rev D Communication s specificatio ns Connectivit y protoc ols One se rial RS-232/RS -485 por t (115 kbp s baud ra te) (Modbu s RTU/ASCII) • (1) Serial Port A (RS -232/R S -485 Full Duplex/R S -485 Half Dupl ex) One ...

  • Emerson 3812 - page 31

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 1: Introduction 3-9000-765 Rev D March 2013 Meter specifications 17 Digital, analog, and frequency outputs Fre q u e n c y / D i g i t a l Output(s) The meter h as u ser -configurable se lections for either a frequency output or Digital status (FODO) (Also see Sectio n 3.6.1 ) (3) ...

  • Emerson 3812 - page 32

    18 Pre-installation considerations Section 1: Introduction Daniel 3812 Liquid Ultrasonic Flow Mete r Installation Manual March 2013 3-9000-765 Rev D 1.7 Pre -installation considerations • Pipeline equipme nt c ode compli ance , ANSI, ASME, etc. • Prope r Inlet/outlet mete r tube piping for re ason able stable flow to the settling chamber (first ...

  • Emerson 3812 - page 33

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 1: Introduction 3-9000-765 Rev D March 2013 Daniel 3812 Certifications and Approvals 19 1.9 Daniel 3812 Cer tifications and Appro vals Danie l 3810 Series Liq uid Ultrasonic Flow Me ters hav e electrical, metrology , intrinsic saf ety and Pressure Equipment Directive cert ificatio ...

  • Emerson 3812 - page 34

    20 FCC compliance Section 1: Introduction Daniel 3812 Liquid Ultrasonic Flow Mete r Installation Manual March 2013 3-9000-765 Rev D ...

  • Emerson 3812 - page 35

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 2: Mechanical installation 3-9000-765 Rev D March 2013 Meter piping, lifting and mounting 21 Sec tion 2: Mech anical install a tion 2.1 Meter piping, lif ting and mounting Re fe r to the following section s for piping recommend ations, lif ting with hoist rings and slings, mounti ...

  • Emerson 3812 - page 36

    22 Meter piping, lifting and mounting Section 2: Mechan ical instal lation Daniel 3812 Liqui d Ultrasonic Flow Meter Installation Manual March 2013 3-9000 -765 Rev D Consult your Daniel Sales and Se r vice represe ntative to e nsure you purcha se the correct compone nts and se als for your application. CRUSHING HAZARD Do not remove flange stabilize ...

  • Emerson 3812 - page 37

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 2: Mechanical installation 3-9000-765 Rev D March 2013 Meter piping, lifting and mounting 23 Mete r component s FLUID CON TENTS MA Y BE UNDER P RESS URE When the meter is under pressure, DO NOT attempt to remo ve or adjust the transducer housing. Atte mpting to do so may r ele as ...

  • Emerson 3812 - page 38

    24 Meter piping, lifting and mounting Section 2: Mechan ical instal lation Daniel 3812 Liqui d Ultrasonic Flow Meter Installation Manual March 2013 3-9000 -765 Rev D Daniel Liquid Ultras onic Flow Meters are asse mble d, configured, and tested at the factor y . The meter c omponen ts include t he transmitter electronics enclosure, the base e lectro ...

  • Emerson 3812 - page 39

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 2: Mechanical installation 3-9000-765 Rev D March 2013 Meter piping, lifting and mounting 25 Figure 2-2 R emote mount me te r ele c tronics assembly with split shroud A. Remote mount explosion-proof transmitter enclosure (CPU Module , Po wer Supply , I.S. B. Intrin sically-safe b ...

  • Emerson 3812 - page 40

    26 Meter piping, lifting and mounting Section 2: Mechan ical instal lation Daniel 3812 Liqui d Ultrasonic Flow Meter Installation Manual March 2013 3-9000 -765 Rev D Figure 2-3 Direct mount meter elec tronics with bolted band shrouds A. B. C. A. Explosion -proof transmitter enclo sure (CPU Module, P ower Supply , I.S. Barrier Board, B. Intrinsicall ...

  • Emerson 3812 - page 41

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 2: Mechanical installation 3-9000-765 Rev D March 2013 Meter piping, lifting and mounting 27 Figure 2-4 Direct mount meter electron ics assembly with clamped band shrouds T able 2-1 3812 U ltrasonic Mete r shrouds options per ANSI pressure r ating Meter body size ANSI p ressure r ...

  • Emerson 3812 - page 42

    28 Piping recommendations Section 2: Mechan ical instal lation Daniel 3812 Liqui d Ultrasonic Flow Meter Installation Manual March 2013 3-9000 -765 Rev D 2.2 Piping recommendations BURST HAZ ARD Before pipe line cle aning and maint enance (“pi gging operati ons ”), remo ve str aighte ning vanes or fl ow conditi oners. F ailure to do so may caus ...

  • Emerson 3812 - page 43

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 2: Mechanical installation 3-9000-765 Rev D March 2013 Piping recommendations 29 Sunshields, pro vided by the cu stome r , may be required t o preve nt exc eeding the proce ss fluid tempe rature when the mete r is mounted in a location with ex tremely hot clima tes. Flow conditio ...

  • Emerson 3812 - page 44

    30 Piping recommendations Section 2: Mechan ical instal lation Daniel 3812 Liqui d Ultrasonic Flow Meter Installation Manual March 2013 3-9000 -765 Rev D Figure 2-6 Piping recomme ndations bidirec tional flow All pipe lengths are minimum: • D = Nomin al pi pe siz e in inches (i.e . 6" pipe siz e; 10 D = 60 in) • P = Pre ssure me asure ment ...

  • Emerson 3812 - page 45

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 2: Mechanical installation 3-9000-765 Rev D March 2013 Piping recommendations 31 Meter tube dime nsions with tube bu ndle or profiler pla te for uni-directio nal and bi-direc tional flow , the min imum straight pipe length is a s follows : • T he bore of the m ating piping shou ...

  • Emerson 3812 - page 46

    32 Meter safety for hoist rings and lif ting slings Section 2: Mechan ical instal lation Daniel 3812 Liqui d Ultrasonic Flow Meter Installation Manual March 2013 3-9000 -765 Rev D 2.3 Meter safe t y for hoist rings and lif ting slings A Danie l Ultrasonic Met e r can be saf ely li f ted and m aneuv e red into and out of a me te r run for installati ...

  • Emerson 3812 - page 47

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 2: Mechanical installation 3-9000-765 Rev D March 2013 Use of appropriate safety engineered sw ivel hoist rings in mete r end flanges 33 When li f ting a Da niel Ultr aso nic Met er b y itse lf , Daniel rec ommends t wo meth ods. These methods are : • U sing appropri ate ly rat ...

  • Emerson 3812 - page 48

    34 Use of appropriate safety engineered swivel hoist rings in meter end flanges Section 2: Mechan ical instal lation Daniel 3812 Liqui d Ultrasonic Flow Meter Installation Manual March 2013 3-9000 -765 Rev D Figure 2-8 Safety approved hois t ring and n on-com pliant eye bolt Safet y precautions usin g safety en gineered swivel hoist rings R ead and ...

  • Emerson 3812 - page 49

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 2: Mechanical installation 3-9000-765 Rev D March 2013 Use of appropriate safety engineered sw ivel hoist rings in mete r end flanges 35 8. Always use se parate sling s for e ach hoist ring. NE VER reeve one sling through both hoist rings. The slings must be of equal le ngth. Eac ...

  • Emerson 3812 - page 50

    36 Use of appropriate safety engineered swivel hoist rings in meter end flanges Section 2: Mechan ical instal lation Daniel 3812 Liqui d Ultrasonic Flow Meter Installation Manual March 2013 3-9000 -765 Rev D 9. Direc t mount option: NEVER allow the slings to c ontact the electronics enclosure . Damage to the enclosure may occu r . Use a spreader ba ...

  • Emerson 3812 - page 51

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 2: Mechanical installation 3-9000-765 Rev D March 2013 Use of appropriate safety engineered sw ivel hoist rings in mete r end flanges 37 10. R emo te moun t op tion : Alwa ys use se parate slings f or eac h hoist ring. NEVER reeve one sling through both hoist rings. The slings mu ...

  • Emerson 3812 - page 52

    38 Use of appropriate safety engineered swivel hoist rings in meter end flanges Section 2: Mechan ical instal lation Daniel 3812 Liqui d Ultrasonic Flow Meter Installation Manual March 2013 3-9000 -765 Rev D 11. NEVER apply shock loads to t he mete r . Always lift the mete r gradua lly . If shock loading eve r occurs, the hoist ri ng must be inspec ...

  • Emerson 3812 - page 53

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 2: Mechanical installation 3-9000-765 Rev D March 2013 Use of appropriate safety engineered sw ivel hoist rings in mete r end flanges 39 How to obtain safety engin eered swivel hoist rings A list of approved manufacturers of safety engineered hoist rings is below: • A merican D ...

  • Emerson 3812 - page 54

    40 Appropriately rated lifting slings Section 2: Mechan ical instal lation Daniel 3812 Liqui d Ultrasonic Flow Meter Installation Manual March 2013 3-9000 -765 Rev D 2.3.2 Appropriat ely rated lif ting slings The following instruct ions are intended t o provide general guidelines f or proper lif ting slings of the Daniel 3812 Ultrasonic meter by it ...

  • Emerson 3812 - page 55

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 2: Mechanical installation 3-9000-765 Rev D March 2013 Appropriately rated lifting slings 41 3. NEVER at tempt to lif t th e m eter usin g on ly one sli ng a ro und the meter . Alw ays use t wo slings wrapped around e a ch e nd of the body as shown be low . A choke r st yle sling ...

  • Emerson 3812 - page 56

    42 Appropriately rated lifting slings Section 2: Mechan ical instal lation Daniel 3812 Liqui d Ultrasonic Flow Meter Installation Manual March 2013 3-9000 -765 Rev D 6. NEVER allow the slings to c ontact the electronics enc losure or the transduc er shrouds. Dam age to the me te r ma y occur . If the sling s do come in c ontac t with the electronic ...

  • Emerson 3812 - page 57

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 2: Mechanical installation 3-9000-765 Rev D March 2013 Mounting requirements in heated or cooled pipelines 43 2.4 Mounting requirements in heated or cooled pipelines The ambie nt ope ratin g tempe rature of the 3812 Li quid Alloca tion e lectronics (i.e. Fl amepr oof enc losure a ...

  • Emerson 3812 - page 58

    44 Mounting requirements in heated or coo led pipelines Section 2: Mechan ical instal lation Daniel 3812 Liqui d Ultrasonic Flow Meter Installation Manual March 2013 3-9000 -765 Rev D ...

  • Emerson 3812 - page 59

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 3: Electrical installation 3-9000-765 Rev D March 2013 Cable length TTL mode 45 Sec tion 3: Elec trical inst alla tion 3.1 Cable length T TL mode The maximum cable leng th is 2000 feet w hen the “ T T L” m od e i s s ele c te d. 3.2 Cable length Open Collec tor mode For the ? ...

  • Emerson 3812 - page 60

    46 Grounding meter electronics housing Section 3: Electrical installati on Daniel 3812 Li quid Ultrasonic Flow Me ter Installation Manual March 2013 3-9000 -765 Rev D 3.3 Grounding meter electronics housin g Daniel 3812 Liquid Ultras onic Flow Meter e lectron ics should be internally grounded for intrinsi cally saf e oper ations. C onnect a wire to ...

  • Emerson 3812 - page 61

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 3: Electrical installation 3-9000-765 Rev D March 2013 Conduit seals 47 Figure 3-2 External gro und lug 3.4 Conduit seals Danie l 3812 Liquid Ultras onic Flow Meters requir e conduit se als for installations in h azardou s en vironmen ts. Adhere to sa f ety instruc tions to pro t ...

  • Emerson 3812 - page 62

    48 Startup for systems using explosion-proof conduit Section 3: Electrical installati on Daniel 3812 Li quid Ultrasonic Flow Me ter Installation Manual March 2013 3-9000 -765 Rev D 3.4.1 S t ar tup for syst e ms using explo sion -proof conduit 1. Assemble flexib le conduit (recommended by D aniel) to the T ransmitter Elec tronics Enclosur e . A con ...

  • Emerson 3812 - page 63

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 3: Electrical installation 3-9000-765 Rev D March 2013 Startup for systems that use flame-proof cable 49 3.4.2 S t ar tup for syst e ms tha t u se fl ame-proof cable 1. Check to m ake certain that all fie ld wiring power is turned OFF . 2. Re mov e the end cap nearest the cable e ...

  • Emerson 3812 - page 64

    50 Wiring and I/O Section 3: Electrical installati on Daniel 3812 Li quid Ultrasonic Flow Me ter Installation Manual March 2013 3-9000 -765 Rev D 3.5 Wiring and I/O Daniel Met erLink u ses the T C P/IP protoc ol to communicate with the 960-24™ MSTS electronics inste ad of Modbus ASCII or RTU . The T C P/IP prot oc ol only works across ei ther Eth ...

  • Emerson 3812 - page 65

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 3: Electrical installation 3-9000-765 Rev D March 2013 CPU Module labeling and LED indicators 51 3.5.1 CPU Module labe ling and LED indicators The mete r’s metrology mode and the statu s of the data trans fe r from the Acquis ition Module to the CPU M odule is indicated via lig ...

  • Emerson 3812 - page 66

    52 CPU Module labeling and LED indicators Section 3: Electrical installati on Daniel 3812 Li quid Ultrasonic Flow Me ter Installation Manual March 2013 3-9000 -765 Rev D T able 3-2 CPU Module labeling and LED func tions CPU Module swit ch Fu n c t i o n Switch position indicator or LED WRITE PRO T . • Write-prot ect mode - with s witch in the ON ...

  • Emerson 3812 - page 67

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 3: Electrical installation 3-9000-765 Rev D March 2013 CPU Module labeling and LED indicators 53 Ethernet communications The Ethe rnet port IP addr ess, subne t m ask, and g at ewa y addres s are so f tware-con figur able . In addition, a met er can be c onfi gured to act as a DH ...

  • Emerson 3812 - page 68

    54 CPU Module labeling and LED indicators Section 3: Electrical installati on Daniel 3812 Li quid Ultrasonic Flow Me ter Installation Manual March 2013 3-9000 -765 Rev D Serial connections Use se rial cable (Danie l P/N 3-2500-401) to c onnect to a PC running Danie l Mete rLink. The cable is designed f or RS -232 communications which is the se rial ...

  • Emerson 3812 - page 69

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 3: Electrical installation 3-9000-765 Rev D March 2013 I/O connections 55 Figure 3-4 PC to mete r serial connection wiring 3.6 I/O connec tions The mete r provides the I/O connections on the CPU Module. Figure 3-5 CPU Module I/O connections RX TX COM DB -9 Connector Fem ale A. B. ...

  • Emerson 3812 - page 70

    56 Frequency/Digital outputs Section 3: Electrical installati on Daniel 3812 Li quid Ultrasonic Flow Me ter Installation Manual March 2013 3-9000 -765 Rev D 3.6.1 F requenc y/Digital outputs The meter h as three use r -configurable selections for c onfiguring either a F requenc y output or Digital output (FODO). • F ODO1 (f our possible pa ramete ...

  • Emerson 3812 - page 71

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 3: Electrical installation 3-9000-765 Rev D March 2013 Frequency/Digital outputs 57 F r equenc y or Digital Outputs (FODO 3) source • FO1A, DO1A, FO1B, DO1B, FO2A, DO2A, FO2B, DO2B • F O1A, DO1A, FO1B, DO1B, FO2A, DO2A, FO2B, DO2B • F reque ncy output 1A is ba sed on fr equ ...

  • Emerson 3812 - page 72

    58 Frequency/Digital outputs Section 3: Electrical installati on Daniel 3812 Li quid Ultrasonic Flow Me ter Installation Manual March 2013 3-9000 -765 Rev D Maximum frequency f or the frequency outputs • 1000Hz • 5000Hz T able 3-5 F requenc y/Digital Outputs possible configurations F r equency/Digital output Source configuration Fr equency /Dig ...

  • Emerson 3812 - page 73

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 3: Electrical installation 3-9000-765 Rev D March 2013 Frequency/Digital outputs 59 Output for FODO1 and Digital Output1 (Group 1 o n the CPU Mo dule) share a common ground and hav e 50V isolation. FODO2 and FODO3 (Group 2 on the CPU Module) share a common ground and have 50V iso ...

  • Emerson 3812 - page 74

    60 Analog input settings Section 3: Electrical installati on Daniel 3812 Li quid Ultrasonic Flow Me ter Installation Manual March 2013 3-9000 -765 Rev D 3.6.2 An alog input se ttings The 960-24™ MSTS has the capability to samp le analog tempe rature (Analog Input 1) and pressure (An alog Input 2) with 4-20 mA signals. These an alog inpu t sign al ...

  • Emerson 3812 - page 75

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 3: Electrical installation 3-9000-765 Rev D March 2013 Configuration protect switch settings 61 3.6.6 C onfi guration pro tec t switch se ttings The mete r’s conf iguration parame te rs and fir mware can be prot ected against change s via CPU Module Write PR O T . sw itch as f ...

  • Emerson 3812 - page 76

    62 Security seal installation Section 3: Electrical installati on Daniel 3812 Li quid Ultrasonic Flow Me ter Installation Manual March 2013 3-9000 -765 Rev D 3.7 Securit y seal installation Securit y seals pro tect the integrity of the meter metrology and pre ve nt tampering with transduce r as semblie s. The follo wing sections deta il how to pr o ...

  • Emerson 3812 - page 77

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 3: Electrical installation 3-9000-765 Rev D March 2013 Direct or remote mount transmitter electronics enclosure seal 63 Procedure 1. R otat e the end cap clock wise fully closing and compre ssing the e nd cap seal. Install the Security latch u sing a 3mm Allen wre nch. 2. Install ...

  • Emerson 3812 - page 78

    64 Base Enclosure Security Seals Section 3: Electrical installati on Daniel 3812 Li quid Ultrasonic Flow Me ter Installation Manual March 2013 3-9000 -765 Rev D 3.7.2 Ba se Enclo sure Securit y Seals Use the following instructions to in stall the securit y seal wire on the Base Enclosure. Procedure 1. Install security wire seal in t o and through t ...

  • Emerson 3812 - page 79

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 3: Electrical installation 3-9000-765 Rev D March 2013 Seal the Junction Box remote mount electronics option 65 3.7.3 Se al the Junction Box re mot e mount e lec tronic s option Use the following instructions to inst all the securi t y seal wire on the junc tion box, if required. ...

  • Emerson 3812 - page 80

    66 Bolted band shroud security seals Section 3: Electrical installati on Daniel 3812 Li quid Ultrasonic Flow Me ter Installation Manual March 2013 3-9000 -765 Rev D 3.7.4 Bolted band shroud sec urit y seals If required, use the following instruc tions to in st all bolted band shrouds securit y wire seals. Figure 3-12 Bolted band shroud securi ty se ...

  • Emerson 3812 - page 81

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 3: Electrical installation 3-9000-765 Rev D March 2013 Clamped band shroud security seals 67 Procedure 1. Be nea th the me te r , install the security wires int o and through the le ft front bolt (Ite m B) and feed through the holes in the right back bolt (Ite m D). 2. R epe at w ...

  • Emerson 3812 - page 82

    68 Split shroud security seals Section 3: Electrical installati on Daniel 3812 Li quid Ultrasonic Flow Me ter Installation Manual March 2013 3-9000 -765 Rev D 3.7.6 Split shroud secur it y seals Use the following instructio ns to install the securit y seal wires on t he split shroud cove r ing the mete r body and transduce r asse mblies. Figure 3-1 ...

  • Emerson 3812 - page 83

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 3: Electrical installation 3-9000-765 Rev D March 2013 Latched band shroud security seals 69 3.7.7 Latched ba nd shroud secur it y seals Use the following instruct ions to install the securit y seal wires on the latched band shrouds co ve ring the met er body and transduc er a ss ...

  • Emerson 3812 - page 84

    70 Latched band shroud security seals Section 3: Electrical installati on Daniel 3812 Li quid Ultrasonic Flow Me ter Installation Manual March 2013 3-9000 -765 Rev D Procedure 1. Install the security seal wire in to and th rough the holes in one of the shroud latches (maximum wire diameter .078 inch ; 2.0 mm). Figure 3-16 Shroud lat ch hole s for s ...

  • Emerson 3812 - page 85

    Daniel 3812 Liquid Ultrasonic Flow Meter Instal lation Manual Section 3: Electrical installation 3-9000-765 Rev D March 2013 Seal conduit ports 71 3.7.8 Se al c onduit por ts The unit should be prope rly sealed with a se al ing compound af ter electrical connec tio ns hav e been te sted acc ording t o the cu stome r's Best Practices schedule . ...

  • Emerson 3812 - page 86

    72 Seal conduit por ts Section 3: Electrical installati on Daniel 3812 Li quid Ultrasonic Flow Me ter Installation Manual March 2013 3-9000 -765 Rev D ...

  • Emerson 3812 - page 87

    Daniel 3812 Liquid Ultrasonic Flow Meter In stallation Manual Section 4: Configuration 3-9000-765 Rev D March 2013 Daniel MeterLink setup 73 Sec tion 4: Con f iguration Af ter the mechanical and electrical installation is complete and connectivit y is established, use the Daniel MeterLink So f t ware for Gas and Liquid Ultras onic Meters Quick St a ...

  • Emerson 3812 - page 88

    74 Field Setup Wizard Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Mete r Installation Manual March 2013 3-9000 -765 Rev D 4.2 Field Setup Wizard 1. Use the Fie ld Setup Wizar d-Star tup Page and select the ch eckbox es that all ow prope r con figuration f or your mete r (T emper ature , Pressure , Mete r C orrec tions, and Met er Ou ...

  • Emerson 3812 - page 89

    Daniel 3812 Liquid Ultrasonic Flow Meter In stallation Manual Section 4: Configuration 3-9000-765 Rev D March 2013 Field Setup Wizard 75 Display It ems The valid l abels, de scrip tions and units f or the shown below: T able 4-1 Local display labels, descriptions and valid units Local Displa y labels, descrip tions and units QFL OW — Unc orrected ...

  • Emerson 3812 - page 90

    76 Field Setup Wizard Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Mete r Installation Manual March 2013 3-9000 -765 Rev D Note : When c onnected to a meter with the op tional local display , reverse flow direc tion is indicated with a minus sign (negative) bef ore the value( s) shown on the displa y . VEL — Average flow velocity ? ...

  • Emerson 3812 - page 91

    Daniel 3812 Liquid Ultrasonic Flow Meter In stallation Manual Section 4: Configuration 3-9000-765 Rev D March 2013 Field Setup Wizard 77 Display units The Meter volume unit s displayed are either U .S. Customar y or M etric. T o modif y the Display Units, c onfi gure the Me te r units syst em in th e Fiel d Setup Wi zard — Ge neral Page . • U . ...

  • Emerson 3812 - page 92

    78 Using AMS Device Manager t o configure the meter Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Mete r Installation Manual March 2013 3-9000 -765 Rev D 4.3 Using AMS Devic e Manager to c onfigure the met er This proc edure as sumes y ou ha ve AMS Devi ce Ma nage r installed on the ho st c ompute r and h av e downloaded the latest Da ...

  • Emerson 3812 - page 93

    Daniel 3812 Liquid Ultrasonic Flow Meter In stallation Manual Section 4: Configuration 3-9000-765 Rev D March 2013 Using AMS Device Mana ger to configure the meter 79 10. Click the D aniel Industries Liquid 3810 Series Rev 1 hype rlink. The file download dialog displa ys. Click the Sa ve butt on to sa ve the files t o your ho st syste m. Y ou may u ...

  • Emerson 3812 - page 94

    80 Using AMS Device Manager t o configure the meter Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Mete r Installation Manual March 2013 3-9000 -765 Rev D 17. Click the C onf igure tab , and then se lect Guided Setup , Manual Setup or Alert Setup . Figure 4-3 AMS Device Manager Figure 4-4 AMS Device Manager - Overview ...

  • Emerson 3812 - page 95

    Daniel 3812 Liquid Ultrasonic Flow Meter In stallation Manual Section 4: Configuration 3-9000-765 Rev D March 2013 Using AMS Device Mana ger to configure the meter 81 AMS Device Manager - Guided Setup The Guided setup wizard pro vides con figuratio n param ete r settings f or the mete r . The Guided Setup is a subse t of th e Manu al Setu p parame ...

  • Emerson 3812 - page 96

    82 Using AMS Device Manager t o configure the meter Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Mete r Installation Manual March 2013 3-9000 -765 Rev D 4. Af ter a ll of the data sh own below is entere d, cl ick Apply to wr ite the pa ram eters to th e mete r . a. Clic k the F requenc y/Digital O utputs tab to con figure F reque nc ...

  • Emerson 3812 - page 97

    Daniel 3812 Liquid Ultrasonic Flow Meter In stallation Manual Section 4: Configuration 3-9000-765 Rev D March 2013 Using AMS Device Mana ger to configure the meter 83 d. Click the All V ariables t ab to view a graphical display of the Pr imar y , Secondar y , Third and Fo ur th V ariables. Figure 4-6 AMS Device Manager - Servic e T ools All V a ria ...

  • Emerson 3812 - page 98

    84 Using AMS Device Manager t o configure the meter Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Mete r Installation Manual March 2013 3-9000 -765 Rev D AMS Devic e Manager - Manual Setup Use t he Manual Setup wiz ard to conf igu re t he m eter’ s para meter s. Se e Figure 4-3 and Figure 4-4 and from the AMS Devic e Manage r Confi ...

  • Emerson 3812 - page 99

    Daniel 3812 Liquid Ultrasonic Flow Meter In stallation Manual Section 4: Configuration 3-9000-765 Rev D March 2013 Using AMS Device Mana ger to configure the meter 85 page . Navig ate back to the Manu al Setup for the ch anges to be re flected in other Manual Setup pages). Click Apply , a fter you e nte r the da ta to write the parame te rs to the ...

  • Emerson 3812 - page 100

    86 Using AMS Device Manager t o configure the meter Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Mete r Installation Manual March 2013 3-9000 -765 Rev D b . Calibration G ating c onfigurati on parame te r se lections are : – Edg e gate d, ac t ive hi gh Figure 4-9 Gating conf iguratio n pa ram eter Edge gated, active high – Ed g ...

  • Emerson 3812 - page 101

    Daniel 3812 Liquid Ultrasonic Flow Meter In stallation Manual Section 4: Configuration 3-9000-765 Rev D March 2013 Using AMS Device Mana ger to configure the meter 87 – State g ated, ac tive low Figure 4-12 Gat ing confi guration parame ter S tate ga ted, activ e low 12. Click the Alert Setup tab (fro m the main Configuration page). Figure 4-13 C ...

  • Emerson 3812 - page 102

    88 Using AMS Device Manager t o configure the meter Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Mete r Installation Manual March 2013 3-9000 -765 Rev D 13. Click the Flow Analysis tab to select Configure Rev erse Flow Detection, if desired. The default sett ing is Disable d . Click the Disabl ed button to send the f ea ture command ...

  • Emerson 3812 - page 103

    Daniel 3812 Liquid Ultrasonic Flow Meter In stallation Manual Section 4: Configuration 3-9000-765 Rev D March 2013 Using AMS Device Mana ger to configure the meter 89 14. Click the Service T ools t ab t o a c ce ss t he d e vi ce a le r ts , v ar ia b l es , tr en d s a n d ma i nten a nc e statuses or to edit the configura tion parameters. a. Clic ...

  • Emerson 3812 - page 104

    90 Using AMS Device Manager t o configure the meter Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Mete r Installation Manual March 2013 3-9000 -765 Rev D c. Cli ck the Ser vice T ools|V ariables tab. The V ariables page displays tabs for th e device ’s Flow D ata, Path Inform ation, Flow T otals, and All V ariables). Figure 4-16 AMS ...

  • Emerson 3812 - page 105

    Daniel 3812 Liquid Ultrasonic Flow Meter In stallation Manual Section 4: Configuration 3-9000-765 Rev D March 2013 Using AMS Device Mana ger to configure the meter 91 g. Click Service T ools|Vari ables|All V ariables tab to view Primar y , Secondar y , Third and Fo ur th V ariable para met er stat us. Figure 4-17 AMS Device Manager - Ser vice T ool ...

  • Emerson 3812 - page 106

    92 Using AMS Device Manager t o configure the meter Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Mete r Installation Manual March 2013 3-9000 -765 Rev D h. Click the Ser vice T ools|T rends tab to display the device vari ables (uncorrec ted volume flow rat e , pressure and te mpera ture) trends. Figure 4-18 AMS Device Ma nager - Ser ...

  • Emerson 3812 - page 107

    Daniel 3812 Liquid Ultrasonic Flow Meter In stallation Manual Section 4: Configuration 3-9000-765 Rev D March 2013 Using a Field Communicator t o configure the meter 93 4.4 Using a Field Communicator to c o nfigure the met er Installation Re quirements • E merson Field Communic ator soft ware, lice nse, installation guide and use r manual avai la ...

  • Emerson 3812 - page 108

    94 Using a Field Communicator to configure the meter Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Mete r Installation Manual March 2013 3-9000 -765 Rev D Procedure 1. R emov e electrical power to the meter . If inst alled, remove the endcap securit y latc hes and seals and the n, remo ve the e ndcap . 2. Re fe r to the Field Communic ...

  • Emerson 3812 - page 109

    Daniel 3812 Liquid Ultrasonic Flow Meter In stallation Manual Section 4: Configuration 3-9000-765 Rev D March 2013 Using a Field Communicator t o configure the meter 95 5. Wire Analog Input 1 (AI1) and An alog Output 1 (AO1) as sh own in Figure 4-20 and Appendix A , drawing DMC -004936. Figure 4-20 Field Communicator wiring diagram f or the 3810 Se ...

  • Emerson 3812 - page 110

    96 Security seals for the meter Section 4: Configuration Daniel 3812 Liquid Ultrasonic Flow Mete r Installation Manual March 2013 3-9000 -765 Rev D 4.5 Securit y seals for the met er For the int egrity of the meter me trology and to prev e nt tampe ring with the transmitter electronics and transducer a ssemblies, at tach security latche s to the Sh ...

  • Emerson 3812 - page 111

    Daniel 3812 Liquid Ultrasonic Flow Mete r Installation Manual Engineering drawings 3-9000-765 Rev D March 2013 Daniel 3812 Liquid Ultrasonic Flow Meter drawings 97 Appendix A Appe ndix A: Engineering dra wing s A .1 Daniel 3812 Liquid Ultr asonic Flow Meter dra wings List of Engineering Drawings This appendix contains the following e ngineering dra ...

  • Emerson 3812 - page 112

    98 Daniel 3812 Liquid Ultrasonic Flow Meter drawings Engineering dr awings Daniel 3812 Liquid Ultrasonic Flow Meter Inst allation Manual March 2013 3-9000 -765 Rev D ...

  • Emerson 3812 - page 113

    ...

  • Emerson 3812 - page 114

    ...

  • Emerson 3812 - page 115

    ...

  • Emerson 3812 - page 116

    ...

  • Emerson 3812 - page 117

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Open source licenses 3-9000-765 Rev D March 2013 99 A Appe ndix B: O pe n sourc e lic e nses Sourc e code f or executable file s or libraries inclu ded in this product is provided per the ind icated lice nse in the table below . Hyperlink s to the c ontrolling org aniza tion's w eb s ...

  • Emerson 3812 - page 118

    100 GNU General Public License Open source licenses Daniel 3812 Liquid Ultrasonic Fl ow Meter Installation Manual March 2013 3-9000-765 Rev D Follo w the link be low t o the Danie l® Liquid Ultras onic Products GPL we bpage fo r addition al open sourc e info rmation and zipped source c ode files. http ://www2.em ersonp roce ss.com /en-US/br ands/d ...

  • Emerson 3812 - page 119

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Open source licenses 3-9000-765 Rev D March 2013 GNU General Public License 101 The GNU General Public License (GPL) Version 2, June 1991 Copyright (C) 1 989, 1991 Free Softwar e Foundation, Inc. 59 Temple Pl ace, Suite 330, Bos ton, MA 02111-1307 USA Everyone is permitt ed to copy and di ...

  • Emerson 3812 - page 120

    102 GNU General Public License Open source licenses Daniel 3812 Liquid Ultrasonic Fl ow Meter Installation Manual March 2013 3-9000-765 Rev D For example, if you distribute copies of such a program, whether gratis o r f o r a f e e , y o u m u s t g i v e t h e recipients all the rights that you have. You must make sure that they, too, receive or c ...

  • Emerson 3812 - page 121

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Open source licenses 3-9000-765 Rev D March 2013 GNU General Public License 103 TERMS AND CONDITIONS FO R COPYING, DISTRI BUTION AND MODIFICATIO N 0 . This License applies to any prog ram or other work which contains a notice placed by the copyright holder saying it may be dis tributed un ...

  • Emerson 3812 - page 122

    104 GNU General Public License Open source licenses Daniel 3812 Liquid Ultrasonic Fl ow Meter Installation Manual March 2013 3-9000-765 Rev D 2 . You may modify your copy or copies of th e Progra m or any portion of it, thus forming a work based on the Program, and copy and distribute such mo difications or work under the terms of Section 1 above, ...

  • Emerson 3812 - page 123

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Open source licenses 3-9000-765 Rev D March 2013 GNU General Public License 105 In addition, mere aggregation of another work not based on the Program with the Program (or with a work based on the Program) on a volume of a storag e or distribution medium does not bring t he other work und ...

  • Emerson 3812 - page 124

    106 GNU General Public License Open source licenses Daniel 3812 Liquid Ultrasonic Fl ow Meter Installation Manual March 2013 3-9000-765 Rev D If distribution of executab le or object code i s made by offeri ng access to copy from a designated place, then offering equi valent acces s to copy the source code f rom the same pl ace counts as distributi ...

  • Emerson 3812 - page 125

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Open source licenses 3-9000-765 Rev D March 2013 GNU General Public License 107 Program by all those who rec eive copies directly or indir ec tly through you, then the only wa y you could satisfy both it and this Lice nse would be to refrain entirely from dist ribution of the Program. If ...

  • Emerson 3812 - page 126

    108 GNU General Public License Open source licenses Daniel 3812 Liquid Ultrasonic Fl ow Meter Installation Manual March 2013 3-9000-765 Rev D conditions either of tha t version or of any later v ersion published by the Free Software Foundation. If the Program does not specify a version number of this License, you may choose any version ev er publis ...

  • Emerson 3812 - page 127

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Open source licenses 3-9000-765 Rev D March 2013 GNU General Public License 109 How to Apply These Terms to Your New Programs If you develop a new program, and you want it to be of the greatest possible use to the public, the best way to achie ve this is to make it free software which eve ...

  • Emerson 3812 - page 128

    110 GNU General Public License Open source licenses Daniel 3812 Liquid Ultrasonic Fl ow Meter Installation Manual March 2013 3-9000-765 Rev D The hypothetical commands `show w' and `show c' sh ould show the appropriate parts of the General Public License. Of course, the commands you use may be called something other than `show w' and ...

  • Emerson 3812 - page 129

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Open source licenses 3-9000-765 Rev D March 2013 GNU Lesser General Public License 111 B.2 GNU Lesser General Public License GNU LESSE R GENERAL PUBLIC LIC ENSE V ersion 3, 29 June 2007 Copyright © 2007 Free Softwa re Foundat ion, Inc. <http://fsf .org/> Everyone is permitted to co ...

  • Emerson 3812 - page 130

    112 GNU Lesser General Public License Open source licenses Daniel 3812 Liquid Ultrasonic Fl ow Meter Installation Manual March 2013 3-9000-765 Rev D The "Corresponding Application Code" for a Co mbi ned W ork means the ob ject code and/or source code for the Application, including an y data and utilit y programs needed for reproducin g th ...

  • Emerson 3812 - page 131

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Open source licenses 3-9000-765 Rev D March 2013 GNU Lesser General Public License 113 4. Combined W orks. Y ou may convey a Co m b ine d W o rk un der terms of your choice that, take n togeth er , effectively do not res trict modification of the portio ns of the Library contained in the ...

  • Emerson 3812 - page 132

    114 GNU Lesser General Public License Open source licenses Daniel 3812 Liquid Ultrasonic Fl ow Meter Installation Manual March 2013 3-9000-765 Rev D 5. Combined Libr aries. Y ou may place library fac ilit ie s that are a work ba s ed on the Library side by sid e in a s ing le library together with ot he r library facilities that are not Application ...

  • Emerson 3812 - page 133

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Open source licenses 3-9000-765 Rev D March 2013 BSD Open Source License 115 B.3 B SD Open Sourc e Lice nse For mor e details abou t the Ope n Sourc e TM BSD li ce nse or t he Open Sour ce In itia tive , follow the link be low: http://www .opensource . org/licenses/bsd-license .php Copyri ...

  • Emerson 3812 - page 134

    116 M.I.T License Open source licenses Daniel 3812 Liquid Ultrasonic Fl ow Meter Installation Manual March 2013 3-9000-765 Rev D B.4 M.I.T Li c ens e For mor e details abo ut the Ope n Sourc e TM MIT license or the Open Source Initia tive follow the link below: http://www .opensource.or g/license s/mit -lice nse.php The MIT License Copyright (c) &l ...

  • Emerson 3812 - page 135

    Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Index 3-9000-765 Rev D March 2013 Manual In dex 117 Appe ndix C Index C. 1 Ma nu a l I nd ex A Acronyms, abbreviations and definitions ............... ........ .. 3 AMS Device Manager - Manua l Setup ............. ........... ...... 84 AMS™ Suite Device Manager ........... ........ .... ...

  • Emerson 3812 - page 136

    Index Daniel 3812 Liquid Ultrasonic Flow Meter Inst allation Manual March 2013 3-9000 -765 Rev D 118 Manual Index incorrect sling attachment ............. ........ ......... .......... .. 42 safety precautions using swivel hoist rings ........ .... 34 Split shroud security seals .............. .......... ........... .. 68 , 69 swivel hoist rings .. ...

  • Emerson 3812 - page 137

    ...

  • Emerson 3812 - page 138

    P/N 3-9000-765 Rev C 2013 Daniel Measuremen t and Control, Inc . 11100 Brittmoore Park Drive Houston, TX 77041 USA T+1 713-467-6000 F+1 713-827-4805 USA Toll Free 1 888-356-9001 Daniel Measuremen t Services, Inc. T +1 713-827-6413 www.Daniel.com This product is a core c omponent of the P lantWeb digital plant archi tecture. Europe: Stirling, Scotla ...

Manufacturer Emerson Category Automobile Parts

Documents that we receive from a manufacturer of a Emerson 3812 can be divided into several groups. They are, among others:
- Emerson technical drawings
- 3812 manuals
- Emerson product data sheets
- information booklets
- or energy labels Emerson 3812
All of them are important, but the most important information from the point of view of use of the device are in the user manual Emerson 3812.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Emerson 3812, service manual, brief instructions and user manuals Emerson 3812. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Emerson 3812.

Similar manuals

A complete manual for the device Emerson 3812, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Emerson 3812 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Emerson 3812.

A complete Emerson manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Emerson 3812 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Emerson 3812, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Emerson 3812, that we can find in the current document
3. Tips how to use the basic functions of the device Emerson 3812 - which should help us in our first steps of using Emerson 3812
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Emerson 3812