    9.957.036 05 PROFLAME GTM SYSTEM USE AND INST ALLA TION INSTRUCTIONS Read the instructions before use. This control must be installed in accordance with the rules in force. ...

  • Regency 9.957.03605 - page 2

    English - 12 2 2 ENGLISH The Proflame GTM is a modular remote control system that directs the functions of a hearth appliance. The Proflame GTM is configured to control the on/off main burner operation, its flame levels, and provides on/off and Smart thermostatic control of the hearth appliance. Comfort control is advanced by the Smart thermostat f ...

  • Regency 9.957.03605 - page 3

    3 Remote Control Supply voltage 4.5 V (three 1.5 V AAA batteries) Ambient temperature ratings 0 - 50 °C (32 - 122 °F) Radio frequency 315 MHz Receiver Supply voltage 6.0 V (four 1.5 V AA batteries) Ambient temperature ratings 0 - 60 °C (32 - 140 °F) Radio frequency 315 MHz TECHNICAL DA T A ENGLISH W ARNING THE TRANSMITTER AND RECEIVER ARE RADIO ...

  • Regency 9.957.03605 - page 4

    4 ENGLISH The Proflame Remote Control System consists of two elements: 1. Proflame Transmitter. 2. Proflame Receiver and a wiring harness to connect the Receiver to the gas valve and stepper motor. The Proflame Transmitter uses a streamline design with a simple button layout and informative LCD display (Fig. 1). The Transmitter is powered by 3 AAA ...

  • Regency 9.957.03605 - page 5

    5 ENGLISH The Proflame Receiver (Fig. 3) connects directly to the gas valve and stepper motor with a wiring harness. The Receiver is powered by 4 AA type batteries. The Receiver accepts commands via radio frequency from the Transmitter to operate the appliance in accordance with with the particular Proflame system configuration. The Receiver three ...

  • Regency 9.957.03605 - page 6

    6 ENGLISH REMOTE REMOTE TP TH TPTH Green Whi te Red Black (+) (-) Fig. 5: Wiring diagram. Initializing the System for the first time Install the 4 AA batteries into the receiver battery bay. Note the polarity of battery and insert into the battery bay as indicated on the Battery cover (+/-). Place the 3 position slider switch in the “Remote” po ...

  • Regency 9.957.03605 - page 7

    7 ENGLISH Fig. 7: Remote Control display. Temperature indication Display With the system in the “OFF” position, press the Thermostat Key and the Mode Key at the same time. Look at the LCD screen on the Transmitter to verify that a C or F is visible to the right of the Room Temperature display. (Fig. 6) Fig. 6: Remote Control display in Farenhei ...

  • Regency 9.957.03605 - page 8

    8 ENGLISH Remote Flame Control The Proflame GTM has six (6) flame levels. With the system on, and the flame level at the maximum in the appliance, pressing the Down Arrow Key once will reduce the flame height by one step until the flame is turned off. The Up Arrow Key will increase the flame height each time it is pressed. If the Up Arrow Key is pr ...

  • Regency 9.957.03605 - page 9

    9 ENGLISH Smart Thermostat (Transmitter Operation) The Smart Thermostat function adjusts the flame height in accordance to the difference between the set point temperature and the actual room temperatures. As the room temperature gets closer to the set point the Smart Function will modulate the flame down. To activate this function, press the Therm ...

  • Regency 9.957.03605 - page 10

    10 ENGLISH Transmitter The life span of the remote control batteries depends on various factors: quality of the batteries used, the number of ignitions of the appliance, the number of changes to the room thermostat set point, etc. When the Transmitter batteries are low, a Battery Icon will appear on the LCD display of the Transmitter (Fig. 19) befo ...

  • Regency 9.957.03605 - page 11

    11 ENGLISH CAUTION Property Damage Hazard. Excessive heat can cause property damage. The appliance can stay lit for many hours. T ur n off the appliance if it is not going to be attended for any lenght of time. Always place the T ransmitter where childr en can not reach it. W ARNING Fire Hazard. Can cause severe injury or death The Receiver causes ...

  • Regency 9.957.03605 - page 12

    PROFLAME T ransmitter PROFLAME Receiver Hearth mounted Wa ll mounted 140 37 71 DIMENSIONAL DRA WINGS Dimensions are in millimeters PRG 102 42 REMOTE PRG 115 70 REMOTE ...

Manufacturer Regency Category Universal Remote

Documents that we receive from a manufacturer of a Regency 9.957.03605 can be divided into several groups. They are, among others:
- Regency technical drawings
- 9.957.03605 manuals
- Regency product data sheets
- information booklets
- or energy labels Regency 9.957.03605
All of them are important, but the most important information from the point of view of use of the device are in the user manual Regency 9.957.03605.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Regency 9.957.03605, service manual, brief instructions and user manuals Regency 9.957.03605. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Regency 9.957.03605.

A complete manual for the device Regency 9.957.03605, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Regency 9.957.03605 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Regency 9.957.03605.

A complete Regency manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Regency 9.957.03605 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Regency 9.957.03605, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Regency 9.957.03605, that we can find in the current document
3. Tips how to use the basic functions of the device Regency 9.957.03605 - which should help us in our first steps of using Regency 9.957.03605
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Regency 9.957.03605
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Regency 9.957.03605 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Regency 9.957.03605?

Use the form below

If you did not solve your problem by using a manual Regency 9.957.03605, ask a question using the form below. If a user had a similar problem with Regency 9.957.03605 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)