Manual Emerson PowerSure Personal XT

12 pages Not applicable
Download

Go to site of 12

Summary
  • Emerson PowerSure Personal XT - page 1

    450, 700, 1250 V A 230V PowerSure TM Personal XT U SER M ANUAL English / Deutsch / Français / Italiano / Español PS PXT-inglese.qxd 6-06-2001 9:51 Pagina 1 ...

  • Emerson PowerSure Personal XT - page 2

    2 IMPORT ANT SAFETY INSTRUCTIONS SA VE THESE INSTRUCTIONS This manual contains important safety instructions that should be followed during the installation and maintenance of the UPS and its batteries. Please read this manual thoroughly before attempting to install or operate this UPS. This equipment can be installed and operated by individuals wi ...

  • Emerson PowerSure Personal XT - page 3

    3 These units bear TUV GS mark, CE mark and comply with the following standards (limits value class B): EN 60950 (1998.8), EN 50091-1 (1994.4), EMI/RFI: EN550222 class B EMS: IEC 1000-4-2 (ESD) Level 3 IEC 1000-4-3 (RS) Level 3 IEC 1000-4-4 (EFT) Level 3 IEC 1000-4-5 (Lightning surge) Level 3 CAUTION: Although your UPS has been designed and manufac ...

  • Emerson PowerSure Personal XT - page 4

    4 INTRODUCTION & SYSTEM DESCRIPTION MAJOR COMPONENTS Congratulations on your choice of the Liebert PowerSure Personal XT Uninterruptible Power System (UPS). It provides conditioned power to microcomputers and other sensitive electronic equipment. ! PowerSure OUTPUT “Lead-acid battery inside the enclosure” “Blei-Akkumulator innerhalb des G ...

  • Emerson PowerSure Personal XT - page 5

    5 GENERAL INST ALLA TION ! PowerSure ! PowerSure ! PowerSure ! PowerSure OUTPUT “Lead-acid battery inside the enclosure” “Blei-Akkumulator innerhalb des Gehause” INPUT FUSE:250V~,5A,T RS232 MODEL:YUNTO Q700 IMPUT:230V~,50/60Hz, 4.0A, 1Ø OUTPUT:230V~,50/60Hz, 700VA/420W , 3.1A MADE IN CHINA Remove from Box Remove Plug from Units and replace ...

  • Emerson PowerSure Personal XT - page 6

    6 NORMAL MODE OPERA TION BA TTER Y MODE OPERA TION 1. Inspect the packaging carton and its contents for damage. Please inform the trasport agency immediately should you find signs of damage. Please keep the packaging in a safe for future use. 2. Plug the UPS into a wall outlet (see figure 1). Let the UPS charge the battery for at least 2 hours. Y o ...

  • Emerson PowerSure Personal XT - page 7

    7 Switch and LEDs Symbol Function On/off T urn the UPS system an and off. 1. Steady: Input power is acceptable; the UPS is in normal mode (online) Status-LED 2. Blinking: Input power is out of (green) tolerance; the UPS is battery mode. 3. Off: No input power or the battery is exhausted or the UPS is switched off. 1. Blinking: The UPS is overloaded ...

  • Emerson PowerSure Personal XT - page 8

    8 If the UPS fails to operate properly , turn off the unit and repeat the steps in the installation section of this manual. If the problem persists, refer to the chart below: PROBLEM POSSIBLE CAUSE REMEDY No indication, no Check building wall outlet and mains cable by beep even UPS is No input voltage connecting another device with cable to this wa ...

  • Emerson PowerSure Personal XT - page 9

    9 Y ou can use MultiLink™ Software to allow your UPS to communicate to your computer via your DB-9 communications port. A MultiLink Software CD is included in the box, or you can download it from our web site at www .liebert.com. The PowerSure™ Personal XT UPS contains a standard DB-9 receptacle located on the rear of the UPS unit. Several sign ...

  • Emerson PowerSure Personal XT - page 10

    10 230V SPECIFICA TIONS ELECTRICAL SPECIFICA TION Model Number PSPXT450-230 PSPXT700-230 PSPXT1250-230 INPUT V oltage 230 V AC (197 - 262 V AC) Frequency 50 Hz ± 4Hz; 60 Hz ± 4Hz Amperage (maximum) 2.6 A 4.0 A 7.0 A Phase 12 φ 2W , Ground OUTPUT Power rating 450 V A - 270 W 700 V A - 420 W 1250 V A - 750 W V oltage 230 V AC ± 10% Frequency 50 H ...

  • Emerson PowerSure Personal XT - page 11

    11 LIMITED W ARRANTY Liebert Corporation extends the following LIMITED W ARRANTY to the purchaser and to its customer (collectively referred to as the "Purchaser"): the enclosed Uninterruptible Power System (UPS) and components are free from defects in materials and workmanship under normal use, service, and maintenance FOR A PERIOD OF TW ...

  • Emerson PowerSure Personal XT - page 12

    12 T echnical Support U.S.A. 1-800-222-5877 Outside the U.S.A. 614-841-6755 U.K. +44 (0) 1793 553355 France +33 (0) 1 43 60 01 77 Germany +49 89 99 19 220 Italy +39 02 98250 1 Netherlands +31 (0) 475 503333 E-mail upstech@liebert.com Web site http://www .liebert.com Worldwide F AX tech support +614-841-5471 The Company Behind The Products With more ...

Manufacturer Emerson Category Uninterruptible power supply (

Documents that we receive from a manufacturer of a Emerson PowerSure Personal XT can be divided into several groups. They are, among others:
- Emerson technical drawings
- PowerSure Personal XT manuals
- Emerson product data sheets
- information booklets
- or energy labels Emerson PowerSure Personal XT
All of them are important, but the most important information from the point of view of use of the device are in the user manual Emerson PowerSure Personal XT.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Emerson PowerSure Personal XT, service manual, brief instructions and user manuals Emerson PowerSure Personal XT. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Emerson PowerSure Personal XT.

Similar manuals

A complete manual for the device Emerson PowerSure Personal XT, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Emerson PowerSure Personal XT by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Emerson PowerSure Personal XT.

A complete Emerson manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Emerson PowerSure Personal XT - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Emerson PowerSure Personal XT, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Emerson PowerSure Personal XT, that we can find in the current document
3. Tips how to use the basic functions of the device Emerson PowerSure Personal XT - which should help us in our first steps of using Emerson PowerSure Personal XT
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Emerson PowerSure Personal XT
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Emerson PowerSure Personal XT in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Emerson PowerSure Personal XT?

Use the form below

If you did not solve your problem by using a manual Emerson PowerSure Personal XT, ask a question using the form below. If a user had a similar problem with Emerson PowerSure Personal XT it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)