Manual Porter-Cable 735

15 pages 0.48 mb
Download

Go to site of 15

Summary
  • Porter-Cable 735 - page 1

    Double Insulated V ariable Speed TIGER SA W ® All-Purpose Saws Patents Pending Instruction manual The Model and Serial No. plate is located on the main housing of the tool. Record these numbers in the spaces below and retain for futur e refer ence. Model No. ______________________________________ T ype ___________________________________________ S ...

  • Porter-Cable 735 - page 2

    2 WORK AREA 1. Keep your work area clean and well lit . Clutter ed benches and dark areas invite accidents. 2. Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust . Power tools cr eate sparks, which may ignite the dust or fumes. 3. Keep bystanders, children, and visitors away while opera ...

  • Porter-Cable 735 - page 3

    3 4. Do not abuse the cord. Never use the cor d to carry the tools or pull the plug from an outlet. Keep cor d away from heat, all, sharp edges or moving parts. Replace damaged cords immediately . Damaged cords increase the risk of electric shock. 5. When operating a power tool outside, use an outdoor extension cord marked “W-A” or “W”. The ...

  • Porter-Cable 735 - page 4

    4 SERVICE 1. T ool service must be performed only by qualified r epair personnel. Service or maintenance performed by unqualified personnel may result in a risk of injury . 2. When servicing a tool, use only identical replacement parts. Follow instructions in the Maintenance Section of this manua l. Use of unauthorized parts or failure to follow Ma ...

  • Porter-Cable 735 - page 5

    5 SYMBOL DEFINITION V ........................ volts A ........................ amperes Hz ........................ hertz W ........................ watts kW ........................ kilowatts µ F ........................ microfarads l ........................ liters kg ........................ kilograms N/cm 2 ........................ newtons per ...

  • Porter-Cable 735 - page 6

    6 If an extension cord is used, make sur e the conductor size is lar ge enough to prevent excessive voltage dr op which will cause loss of power and possible motor damage. A table of recommended extension cor d sizes will be found in this section. This table is based on limiting line voltage drop to 5 volts (10 volts for 230 volts) at 150% of rated ...

  • Porter-Cable 735 - page 7

    7 Fig. 1 B A A Fig. 3 A Fig. 2 FUNCTIONAL DESCRIPTION FOREWORD The Porter -Cable TIGER SAW ® is designed for cutting wood up to 12" thick, metal up to 3 / 4 " thick and various other materials, such as plastics, fiber glass, hard rubber , etc. ASSEMBL Y SELECTING THE BLADE For best performance, longer blade life, and smoother cut, select ...

  • Porter-Cable 735 - page 8

    8 A Fig. 5 Fig. 6 B Fig. 7 FLUSH RECESSED BREAK BREAK BROKEN BLADE BROKEN BLADE A Fig. 4 work the blade up and down while rotating the clamp (in a counter - clockwise direction). If the blade breaks leaving nothing to grasp (to pull it from the clamp), it may be necessary to use another blade as a tool to aid in removing the br oken piece (see Fig. ...

  • Porter-Cable 735 - page 9

    9 Fig. 8 Fig. 9 A OPERA TING CONTROLS AND ADJUSTMENTS HOW TO HOLD SAW The gear housing, intermediate plate, blade and pivoting guide shoe may be made live if the blade cuts into live wiring within a wall. TO PREVENT ACCIDENT AL ELECTRICAL SHOCK THE SAW MUST BE HELD AS SHOWN IN FIG. 8, AND HA VE THE RUBBER FRONT HOUSING COVER PROPERL Y INST ALLED AN ...

  • Porter-Cable 735 - page 10

    10 →→ ←← A Fig. 10 A Fig. 11 Fig. 12 A DUAL BLADE MOTION (Model 737 only) Model 737 has dual blade motion: you have a choice of straight recipr ocating motion, as shown in Fig. 10, or orbital motion as shown in Fig. 11. Straight recipr ocating motion should be used for all metal cutting operations, and for wood cutting applications where fi ...

  • Porter-Cable 735 - page 11

    11 Fig. 13 Fig. 14 OPERA TIONS BEFORE YOU ST ART TO WORK Select the blade best suited for the material to be cut (see ACCESSORIES). For greatest economy , use the shortest blade suitable for the thickness of the material to be cut. Be sure the material to be cut is rigid. Small work pieces should be secur ely clamped in a bench vise or with clamps ...

  • Porter-Cable 735 - page 12

    12 MAINTENANCE KEEP TOOL CLEAN Periodically blow out all air passages with dry compressed air . All plastic parts should be cleaned with a soft damp cloth. NEVER use solvents to clean plastic parts. They could possibly dissolve or otherwise damage the material. W ear safety glasses while using compressed air . F AILURE TO ST ART Should your tool fa ...

  • Porter-Cable 735 - page 13

    13 ACCESSORIES A complete line of accessories is available from your Porter -Cable · Delta Supplier , Porter -Cable · Delta Factory Service Centers, and Porter -Cable Authorized Service Stations. Please visit our W eb Site www .porter - cable.com for a catalog or for the name of your nearest supplier . Since accessories other than those offer ed ...

  • Porter-Cable 735 - page 14

    14 PORTER-CABLE LIMITED ONE YEAR WARRANTY Porter -Cable warrants its Professional Power T ools for a period of one year from the date of original purchase. W e will repair or replace at our option, any part or parts of the pr oduct and accessories covered under this warranty which, after examination, proves to be defective in workmanship or materia ...

  • Porter-Cable 735 - page 15

    The following are trademarks of PORTER-CABLE • DEL T A (Las siguientes son marcas registradas de PORTER-CABLE • DEL T A S.A.) (Les marques suivantes sont des marques de fabriquant de la POR TER-CABLE • DEL T A): Auto-Set ® , BAMMER ® , B.O.S.S. ® , Builder’ s Saw ® , Contractor’ s Saw ® , Contractor’ s Saw II™, Delta ® , DEL T A ...

Manufacturer Porter-Cable Category Cordless Saw

Documents that we receive from a manufacturer of a Porter-Cable 735 can be divided into several groups. They are, among others:
- Porter-Cable technical drawings
- 735 manuals
- Porter-Cable product data sheets
- information booklets
- or energy labels Porter-Cable 735
All of them are important, but the most important information from the point of view of use of the device are in the user manual Porter-Cable 735.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Porter-Cable 735, service manual, brief instructions and user manuals Porter-Cable 735. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Porter-Cable 735.

Similar manuals

A complete manual for the device Porter-Cable 735, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Porter-Cable 735 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Porter-Cable 735.

A complete Porter-Cable manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Porter-Cable 735 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Porter-Cable 735, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Porter-Cable 735, that we can find in the current document
3. Tips how to use the basic functions of the device Porter-Cable 735 - which should help us in our first steps of using Porter-Cable 735
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Porter-Cable 735
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Porter-Cable 735 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Porter-Cable 735?

Use the form below

If you did not solve your problem by using a manual Porter-Cable 735, ask a question using the form below. If a user had a similar problem with Porter-Cable 735 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)