Manual Smeg L23LINP

16 pages Not applicable
Download

Go to site of 16

Summary
  • Smeg L23LINP - page 1

    INST ALLA TION & USER INSTR UCTIONS All instructions must be handed to the user for saf ek eeping. Revision A - 08/07 Countr y(s) of destination - GB/IE L30 F AB P23 LINEAR, P23 CLASSIC L23 LINEAR, L23 CLASSIC MODELS W ALL MOUNTED HIGH EFFICIENCY GAS FIRE SMEG (UK) L TD 3 Milton Park Abingdon, Oxon O X14 4RN Phone: +44 (0)870 99 09 907 Fax : +4 ...

  • Smeg L23LINP - page 2

    L30 Fab P23 Linear P23 Classic L23 Linear L23 Classic © 2007 Smeg (UK) L TD Please note : Except where otherwise stated, all rights, including cop yright in the text, images and la y out of this booklet is owned by Smeg (UK) L TD . Y ou are not permit- ted to cop y or adapt an y of the content without the prior written permission of Smeg (UK) L TD ...

  • Smeg L23LINP - page 3

    This appliance is a high efficiency , flueless catalytic flame effect gas fir e. It pro vides radiant and conv ected warmth both effi cient- ly and safel y utilising the latest type catalytic conv erter and burner technology . The appliance does not requir e a flue system of any type as the catal ytic conv erter cleans the flue products to pr ovide ...

  • Smeg L23LINP - page 4

    If the appliance is to be sited near a disused or unserviceable fireplace served by a natural draught flue then the old flue mu st be sealed off. It will be necessar y to ventilate the old flue to pre v ent condensation and dampness forming, howe v er any air v ent use d to ventilate the old flue m ust not be sited within 500mm of this appliance. I ...

  • Smeg L23LINP - page 5

    The appliance is designed to be v ersatile, and as such will operate correctly when exposed to normal gentle draughts experienced within the home. It is not r ecommended, howev er that the appliance be installed in ar eas wher e it is lik ely to be dir ectly expose d to persistent strong draughts, that ma y be generated by outside doors, windows, a ...

  • Smeg L23LINP - page 6

    Remov e the outer packaging, remo ve an y instructions or fixing kits. Read ALL these instructions before continuing to unpack or install this a ppliance. Lift off the remaining packaging components and r emov e the contents of the bo x. Check that the components supplied corr elate with the component checklist. Please dispose of all the packaging ...

  • Smeg L23LINP - page 7

    If the appliance is to be mounted on the inner leaf of a conv entional ca vity brick wall, or a solid wall, then the fibr e wall plugs and fixing scr ews pr ovided ma y be used. Depending on the condi- tion of the wall it ma y be necessary to use additional fixings. In this situation, an y additional fixings and wallplugs should be of the same size ...

  • Smeg L23LINP - page 8

    Classic models : The control knob is located on the low er right hand side of the outer case.It is marked as shown in figur e 6; Linear models : The control knob is located on the low er right hand side of the outer case. It is marked as shown in figur e 7; Fab models : The contr ol knob is located on the low er right hand side of the outer case. I ...

  • Smeg L23LINP - page 9

    Please note that the Linear and Classic models are supplied with a tinted glass facia assembly , which dif- fer in appearance when vie wed fr om the fr ont, simi- larly the F ab model is supplied with a metal facia, ho we ver the method of attachment to the appliance, for all frame designs, is the same . All models : Remov e the facia panel fr om a ...

  • Smeg L23LINP - page 10

    All models : Firstly , r emov e the decorative frame/glass facia assembly as described in section 8.3. Remove the inner glass panel, and disconnect the gas connection inside appliance. The gas connections to the gas valve can no w be released. Detach the burner front co v er plate by r emoval of the four retaining scr e ws (as shown in figur e 9, s ...

  • Smeg L23LINP - page 11

    It is recommended that the catal ysts are inspected f or signs of damage and dirt during routine servicing procedures. The expect- ed life of the catalysts is in excess of 11,000 hours (10 y ears of normal use). After this time the catalysts should be replaced . If there ar e an y deposits of dirt or soot on the catalyst they should be cleaned with ...

  • Smeg L23LINP - page 12

    Fire sparks but pilot does not light No gas to fir e, check isolators are open. Pipe work blockage, clean out. Air not fully purged, r e purge supply or wait longer . Spark earthing to metal work, reset ga p corr ectly . Block ed pilot, clean out internally . Pilot lights but then goes out Sev er e restriction in gas suppl y: clear obstruction. Fau ...

  • Smeg L23LINP - page 13

    Section Content P age No 1.0 Important Notes 1 2.0 Clearances to Combustibles 1 3.0 V entilation & Room Size 2 4.0 Operating Instructions 3 5.0 Combustion Monitoring System 3 6.0 Cleaning 3 7.0 Ser vicing 4 8.0 List of Replacement Parts 4 9.0 Installation Details 4 10.0 Ser vice Histor y 4 The installation and Ser vicing of this fir e MUST only ...

  • Smeg L23LINP - page 14

    Clearances to combustible materials Combustible materials are def ined as wood, fabrics, or other materials likel y to combust if exposed to flame. Generally , an y mate- rial, which is lik ely to discolour , melt or misshape when exposed to moderate heat, should be consider ed as a combustible mate- rial or surface. Clearance to the sides of the a ...

  • Smeg L23LINP - page 15

    Classic models : The control knob is located on the low er right hand side of the outer case.It is marked as shown in figur e 6; Linear models : The control knob is located on the low er right hand side of the outer case. It is marked as shown in figur e 7; Fab models : The contr ol knob is located on the low er right hand side of the outer case. I ...

  • Smeg L23LINP - page 16

    The appliance should be check ed on an annual basis to ensur e it is w orking safely and that ther e is no excessiv e build up of so ot. The frequency of service will depend on usage , but MUST be carried out at least once annually . Ser vicing must be carried out b y a competent person, such as a CORGI register ed installer . The Installation inst ...

Manufacturer Smeg Category Fireplace

Documents that we receive from a manufacturer of a Smeg L23LINP can be divided into several groups. They are, among others:
- Smeg technical drawings
- L23LINP manuals
- Smeg product data sheets
- information booklets
- or energy labels Smeg L23LINP
All of them are important, but the most important information from the point of view of use of the device are in the user manual Smeg L23LINP.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Smeg L23LINP, service manual, brief instructions and user manuals Smeg L23LINP. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Smeg L23LINP.

Similar manuals

A complete manual for the device Smeg L23LINP, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Smeg L23LINP by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Smeg L23LINP.

A complete Smeg manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Smeg L23LINP - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Smeg L23LINP, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Smeg L23LINP, that we can find in the current document
3. Tips how to use the basic functions of the device Smeg L23LINP - which should help us in our first steps of using Smeg L23LINP
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Smeg L23LINP
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Smeg L23LINP in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Smeg L23LINP?

Use the form below

If you did not solve your problem by using a manual Smeg L23LINP, ask a question using the form below. If a user had a similar problem with Smeg L23LINP it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)