Manual Fluke Fluke 16

12 pages 0.22 mb
Download

Go to site of 12

Summary
  • Fluke Fluke 16 - page 1

    PN 644226 July, 1997 Rev.1, 3/99 © 1997,1999 Fluke Corporation, Al l rights reserved. Printed in U .S.A. All p r oduct names are trademarks of their respective companies. 1 ® 16 Multimeter with Temperature Calibration Information W Warning To avoid electrical shock, remove test leads and any input signals from the Meter before opening the case. C ...

  • Fluke Fluke 16 - page 2

    16 Multimeter with Temperature 2 Accuracy specifications are given as follows: ±([% of reading] + [number of least significant digits]). Table 1. Specifications (cont) Function Range Resolution Accuracy f (50 to 400 Hz) 4000 mV 1 4.000 V 40.00 V 300.0 V 400.0 V 600.0 V 1 mV 0.001 V 0.01 V 0.1 V 0.1 V 1 V ±(1.9%+3) ±(1.9%+3) ±(1.9%+3) NA ±(1.9% ...

  • Fluke Fluke 16 - page 3

    Specifications 3 Table 1. Specifications (cont) Function Overload Protection 1 Input Impedance (Nominal) Common Mode Rejection Ratio (1 k Ω Unbalanced) 2 Normal Mode Rejection 2 f 600 V dc >5 M Ω <100 pF 2 Automatic Selection and LoZ = >2 k Ω <200 pF (ac coupled) 3 >60 dB at dc 50 Hz or 60 Hz E 600 V dc >10 M Ω <100 pF ...

  • Fluke Fluke 16 - page 4

    16 Multimeter with Temperature 4 Disassembly and Reassembly Referring to Figure 1, disassemble the Meter as follows. A Phillips-head screwdriver and small flat-blade screwdriver are required. 1. Remove the test leads and set the rotary knob to OFF. 2. Remove the Phillips-head screws from the case bottom. 3. Separate the case top from the case botto ...

  • Fluke Fluke 16 - page 5

    Recommended Test Equipment 5 Case, Top Decal Switch Assembly Actuator, Switch Main PCA Shield, Bottom Foot LCD Conn. Elastomeric Conn. Elastomeric LCD to PCA Support, Switch Assembly Battery Shock Absorber Case, Bottom Screw, THD Form, PH.P.STL, 5-14 x .750 ig3f.eps Figure 1. Model 16 Disassembled Unit ...

  • Fluke Fluke 16 - page 6

    16 Multimeter with Temperature 6 1 2 3 Snap Snap Snaps ig2f.eps Figure 2. Removing and Reinserting the Printed Circuit Assembly ...

  • Fluke Fluke 16 - page 7

    Performance Test 7 Performance Test W Warning To avoid electric shock, do not execute the performance tests procedures unless the Meter is fully assembled. To ensure that the Meter is working properly and performs to specifications, use the following procedures. If the Meter fails this test, it needs calibration adjustment or repair. Multimeter Not ...

  • Fluke Fluke 16 - page 8

    16 Multimeter with Temperature 8 Table 3. Performance Tests Test No. Meter Range Input To Meter Switch Position Display Minimum Display Maximum 1 2 3 4 5 6 7 8 9 1 10 4.000 V ac 4.000 V ac, MIN MAX 4.000 V ac 4.000 V ac 4.000 V ac 4.000 V ac 40.00 V ac 40.00 V ac 400.0 V ac 600 V ac 0 V 0 V 10 mV, 50 Hz 10 mV, 400 Hz 3.5 V, 50 Hz 3.5 V, 400 Hz 35 V ...

  • Fluke Fluke 16 - page 9

    Calibration Adjustments 9 + + 5700A Ice Bath AK-80 Banana Plug Temperature Yellow Red Copper 0 ig6f.eps Figure 3. Performance Test for Temperature + _ 9V BATTERY + Clip to Base Contacts Adjust R4 for 3.997-4.003V DC Input Receptacles + ig1f.eps Figure 4. Calibration Adjustment for DC Voltage ...

  • Fluke Fluke 16 - page 10

    16 Multimeter with Temperature 10 Temperature Note Adjust DC voltage (R4) before adjusting temperature (R38). The following describes three temperature calibration procedures: • Calibrating at room temperature. Use this procedure if it is not necessary to optimize the Meter’s performance. • Calibrating in an ice bath. Use this procedure to op ...

  • Fluke Fluke 16 - page 11

    Replacement Parts 11 ! CAL ENABLE 10A 100 mA 1000V 750V MAX ALL INPUTS 1kV MAX 500mA F 250V POWER AUTO 2ND MN MX RATE dB REL LOCAL THRESH ADDR BAUD HOLD LO HI COMP A A V FREQ DUAL DISPLAY MULTIMETER 45 V REF# REF V COM FUSED 80T-150U + _ 9V BATTERY + + R38 Clip to Base Contacts V m ig4f.eps Figure 5. Calibration Adjustment for Temperature Using the ...

  • Fluke Fluke 16 - page 12

    16 Multimeter with Temperature 12 ...

Manufacturer Fluke Category Universal Remote

Documents that we receive from a manufacturer of a Fluke Fluke 16 can be divided into several groups. They are, among others:
- Fluke technical drawings
- 16 manuals
- Fluke product data sheets
- information booklets
- or energy labels Fluke Fluke 16
All of them are important, but the most important information from the point of view of use of the device are in the user manual Fluke Fluke 16.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Fluke Fluke 16, service manual, brief instructions and user manuals Fluke Fluke 16. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Fluke Fluke 16.

Similar manuals

A complete manual for the device Fluke Fluke 16, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Fluke Fluke 16 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Fluke Fluke 16.

A complete Fluke manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Fluke Fluke 16 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Fluke Fluke 16, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Fluke Fluke 16, that we can find in the current document
3. Tips how to use the basic functions of the device Fluke Fluke 16 - which should help us in our first steps of using Fluke Fluke 16
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Fluke Fluke 16
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Fluke Fluke 16 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Fluke Fluke 16?

Use the form below

If you did not solve your problem by using a manual Fluke Fluke 16, ask a question using the form below. If a user had a similar problem with Fluke Fluke 16 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)