    www.rosemount.com ¢00825-0100-4801J¤ HART ® Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S Rosemount 3051S Series Pressure T ransmitter with HART ® Protocol Rosemount 3051SF Series Flowmeter T ransmitter with HART ® Protocol © 2008 Rosemount Inc. All rights reserved. All marks property of owne r . Rosemount and ...

  • Emerson 3051S - page 2

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 2 Rosemount Inc. 8200 Market Boulevard Chanhassen, MN USA 55317 T (US) (800) 999-9307 T (Intnl) (952) 906-8888 F (952) 949-7001 Emerson Proces s Management GmbH & Co. OHG Argelsrieder Feld 3 82234 Wessling Germany T 49 (8153) 9390, F49 (8153) 939172 Emerson Proces s ...

  • Emerson 3051S - page 3

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 3 W ARNING Explosions could result in death or serious injury: Installation of this transmitter in an explosive environment must be in accordance with the appropriate local, national, and international standards, codes, and practices. Please review the approvals section ...

  • Emerson 3051S - page 4

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 4 S TEP 1: M OUNT THE T RANSMITTER Liquid Flow Applications 1. Place taps to the side of the line. 2. Mount beside or below the taps. 3. Mount the transmitter so that the drain/vent valves are oriented upward. Gas Flow Applications 1. Place taps in the top or side of the ...

  • Emerson 3051S - page 5

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 5 S TEP 1 CONTINUED ... Panel Mount Pipe Mount Coplanar ™ Flange T raditional Flange In-line Housings PlantWeb ™ Junction Box Remote Mount Display 4801_QIG_RevHA.fm Page 5 Tues day, Februa ry 26, 2008 12:17 PM ...

  • Emerson 3051S - page 6

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 6 S TEP 2: C ONSIDER H OUSING R OT ATION S TEP 3: S ET S WITCHES AND J UMPERS If alarm and security adjustment option is not installed, the transmitter will operate normally with the default alarm condition alarm high and the security off . T o improve field access to wi ...

  • Emerson 3051S - page 7

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 7 S TEP 4: C ONNECT W IRING AND P OWER U P Use the following steps to wire the transmitter: 1. Remove the housing cover labeled “Field T erminals.” 2. Connect the positive lead to the “+” terminal, and the negative lead to the “–” terminal. NOTE Do not conn ...

  • Emerson 3051S - page 8

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 8 S TEP 4 CONTINUED ... Remote Display Wiring and Power Up The Remote Mount Display and Interf ace system consists of a local transmitter and a remote mount LCD display assembly . The local 3051S transmitter assembly includes a Junction Box housing with a three position ...

  • Emerson 3051S - page 9

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 9 S TEP 4 CONTINUED ... Intrinsic Safety Consideration: The transmitter assembly with remote display has been approved with Belden 3084A DeviceNet cable. Alternate cable may be used as long as the transmitter with remote display and cable is configured according to the i ...

  • Emerson 3051S - page 10

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 10 S TEP 4 CONTINUED ... NOTE Wire colors provided on page 9 are per Belden 3084A DeviceNet cable. Wire color may vary depending on cable selected. Belden 3084A DeviceNet cable includes a ground shield. This shield must be connected to earth ground at either the SuperMod ...

  • Emerson 3051S - page 11

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 11 S TEP 4 CONTINUED ... 2. Place coupling nut over quick connect and wrench tighten to a maximum of 300 in-lb. (34 N-m). 3. T ighten the set screw using a 3 / 32 -in hex wrench. 4. Install Cordset/ Field Wireable Co nnectors onto the Quick Connect. Do not over tighten. ...

  • Emerson 3051S - page 12

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 12 S TEP 4 CONTINUED ... Power Supply The dc power supply should provide power with less than two percent ripple. The total resistance load is the sum of the resistance of the signal leads and the load resistance of the controller , indicator , and related pieces. Note t ...

  • Emerson 3051S - page 13

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 13 S TEP 5: V ERIFY C ONFIGURATION Use any HART -compliant master to communicate with and verify configuration of the 3051S. For the HART Diagnostics transmitter (option code DA1), DD revision 3051S HDT Dev . 1 Rev . 1 is required. A check ( ⻫ ) indicates the basic con ...

  • Emerson 3051S - page 14

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 14 S TEP 5 CONTINUED ... Function Fast Key Sequence Saturation Level Configura tion 1, 4, 2, 7, 8 Scaled D/A T rim (4–20 mA Output) 1, 2, 3, 2, 2 Scaled V ariable Configu ration 1, 4, 3, 4, 7 Self T est (T ransmitter) 1, 2, 1, 1 Sensor Information 1, 4, 4, 2 Sensor T e ...

  • Emerson 3051S - page 15

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 15 S TEP 6: T RIM THE T RANSMITTER T ransmitters are shipped fully calibrat ed per request or by the factory default of full scale (lower range value = zero, upper range value = upper range limit). Zero T rim A zero trim is a single-point adjustment used for compensating ...

  • Emerson 3051S - page 16

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 16 Using the T ransmitter Zero Adjustment Button Push and hold the zero adjustment button for at least two seconds but no longer than ten seconds. Figure 8. T ransmi tter Adjustme nt Buttons PlantWeb Junction Box Span Zero Span Zero 4801_QIG_RevHA.fm Page 16 Tuesday, Feb ...

  • Emerson 3051S - page 17

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 17 S AFETY I NSTRUMENTED S YSTEMS Additional Safety Instrumented System s information is available in the Rosemount 3051S reference manual (document number 00809-0100-4801). The manual is available electronically on www .rosemount.com or by cont acting an Emerson Process ...

  • Emerson 3051S - page 18

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 18 Inst allation No special installation is required in addition to the st andard installation practices outlined in this document. Always ensure a proper seal by installing the electr onics housing covers so that metal co ntacts metal . The loop should be designed so th ...

  • Emerson 3051S - page 19

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 19 NOTES 1. T ransmitter output is not safety-rated during the following: configuration changes, multidrop, loop test. Alternative means should be used to ensure process safety during transmitter configuration and maintenance activities. 2. DCS or safety logic solver sho ...

  • Emerson 3051S - page 20

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 20 Setting the alarm values and directi on is dependent on whether or not the hardware switch option is insta lled. Y ou can use a HAR T master or communicator to set the Alarm and Saturation values. Switches installed 1. If using a communicator , use the following fast ...

  • Emerson 3051S - page 21

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 21 Operation and Maintenance Proof T est and Inspection The following proof tests are recommended. Proof test result s and corrective actions taken must be documented at www .emersonprocess.com/rosemount/safety/certtechdocumentation. htm in the event that an error is fou ...

  • Emerson 3051S - page 22

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 22 Proof T est 2 This proof test, when combined with the Proof T est 1, will detect over 92% of DU failures not detected by the 3051S_C or 3051S_L automatic diagnostics, and over 95% of DU failures not detected by the 3051S_T automatic diagnostics. Required tools: HART h ...

  • Emerson 3051S - page 23

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 23 Reference Certification The 3051S Safety-Certified Pressure T ransmitter was designed, developed, and audited to be complia nt to IEC 61508 safety-certified SIL 2 Claim Limit. Specifications The 3051S Safety-Certified Pressure T ransmitter must be operated in accordan ...

  • Emerson 3051S - page 24

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 24 P RODUCT C ERTIFICATIONS Approved Manufacturing Locations Rosemount Inc. — Chanhassen, Minnesota USA Fisher-Rosemount GmbH & Co. — Wessling, Germany Emerson Process Management Asia Paci fic Private Limited — Singapore Beijing Rosemount Far East Instru ment C ...

  • Emerson 3051S - page 25

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 25 Hazardous Locations Certifications North American Certifications FM Approvals E5 Explosion proof for Class I, Division 1, Groups B, C, and D; dust-ignition proof for Class II a nd Class III, Division 1, Groups E, F , and G; hazardous locations; en closure T ype 4X, co ...

  • Emerson 3051S - page 26

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 26 European Certifications I1 A TEX Intrinsic Safety Certificate No.: BAS01A TEX1303X II 1 G EEx ia IIC T4 (T a = -60 °C to 70 °C) -HART/Remote Display/Quick Connect/HAR T Diagnostics 1 180 Special Conditions for Safe Use (X) 1. The apparatus, excluding the T ypes 3051 ...

  • Emerson 3051S - page 27

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 27 Special Conditions for Safe Use (x) The apparatus is not capable of withst anding the 500V insulation test required by Clause 9.1 of EN 50021: 1999. This must be taken into account when installing the app aratus. ND A TEX Dust Certificate No.: BAS01A TEX1374X II 1 D T ...

  • Emerson 3051S - page 28

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 28 E1 A TEX Flame-Proof Certificate No.: KEMA00A TEX2143X II 1/2 G EEx d IIC T6 (-50 °C ≤ T amb ≤ 65 °C) EEx d IIC T5 (-50 °C ≤ T amb ≤ 80 °C) V max = 42.4V 1 180 Special conditions for safe use (x) This device contains a thin wall diaphragm. Installation, ma ...

  • Emerson 3051S - page 29

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 29 Australian Certifications E7 SAA Explosion-Proof and Dust Ignition-Proof Certification No.: AUS Ex 3798X Ex d IIC T6 (T a = 60°C) IP66 DIP A21 T A T6 (T a = 60°C) IP66 Conditions for safe use (X) 1. It is a condition of safe use that each housing shall be connected ...

  • Emerson 3051S - page 30

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 30 I7 IECEx Intrinsic Safety Certificate No.: IECExBAS04.0017X Ex ia IIC T4 (T a = -60 °C to 70 °C) -HART/Remote Display/Quick Connect/HAR T Diagnostics IP66 Conditions for safe use (X) 1. The 3051S HART 4-20mA, 3051S F OUNDATION fieldbus, 3051S Profibus and 3051S FISC ...

  • Emerson 3051S - page 31

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 31 Combinations of Certifications S tainless steel certification t ag is pr ovided when optional approval is specified. Once a device labeled with multiple approval types is installed, it should not be reinst al led using any other approval types. Permanently mark the ap ...

  • Emerson 3051S - page 32

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 32 4801_QIG_RevHA.fm Page 32 Wednes day, Februa ry 20, 2008 9:16 AM ...

  • Emerson 3051S - page 33

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 33 4801_QIG_RevHA.fm Page 33 Wednes day, Februa ry 20, 2008 9:16 AM ...

  • Emerson 3051S - page 34

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 34 4801_QIG_RevHA.fm Page 34 Wednes day, Februa ry 20, 2008 9:16 AM ...

  • Emerson 3051S - page 35

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 35 4801_QIG_RevHA.fm Page 35 Wednes day, Februa ry 20, 2008 9:16 AM ...

  • Emerson 3051S - page 36

    Quick Installation Guide 00825-0100-4801, Rev HA February 2008 Rosemount 3051S 36 NOTES 4801_QIG_RevHA.fm Page 36 Tuesday, Februar y 26, 2008 12:17 PM ...

Manufacturer Emerson Category Pacemaker

Documents that we receive from a manufacturer of a Emerson 3051S can be divided into several groups. They are, among others:
- Emerson technical drawings
- 3051S manuals
- Emerson product data sheets
- information booklets
- or energy labels Emerson 3051S
All of them are important, but the most important information from the point of view of use of the device are in the user manual Emerson 3051S.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Emerson 3051S, service manual, brief instructions and user manuals Emerson 3051S. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Emerson 3051S.

Similar manuals

A complete manual for the device Emerson 3051S, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Emerson 3051S by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Emerson 3051S.

A complete Emerson manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Emerson 3051S - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Emerson 3051S, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Emerson 3051S, that we can find in the current document
3. Tips how to use the basic functions of the device Emerson 3051S - which should help us in our first steps of using Emerson 3051S
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Emerson 3051S
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Emerson 3051S in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Emerson 3051S?

Use the form below

If you did not solve your problem by using a manual Emerson 3051S, ask a question using the form below. If a user had a similar problem with Emerson 3051S it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)