  • Moen 200-0564 - page 1

    Handheld Scanner (200-0564) Features Faxback Doc. # 38252 Your new Radio Shack PRO-64 400-Channel Portable Scanner gives you direct access to over 32,000 exciting frequencies, including police and fire departments, ambulance services, and amateur radio services. You can select up to 400 channels to scan, and you can change your selection at any tim ...

  • Moen 200-0564 - page 2

    Duplicate Frequency Check - automatically notif ies you if y ou are abou t to store a frequency y ou have already s tored, to help avoid w asting s torage space. Liquid Crystal Display - makes it easy to view and change programming information. Ten Priority Channels - let you set the scanner so it c hecks the nex t priority c hannel, in or der, ev ...

  • Moen 200-0564 - page 3

    W e recommend you record your scanner's serial number here. This number is on the scanner's back panel. Serial Number:________________________________________ __ Your PRO-64 scanner can receive all of these f requencies: 29-54 MHz (10-Meter Amateur Radio, VHF Lo, 6-Meter Amateur Radio) 108-136.975 MHz (Aircraft) 137-174 MHz (Government, 2 ...

  • Moen 200-0564 - page 4

    services, and wireline (telephone and telegraph) service providers. It is legal to listen to almost every transmission your scanner can receive. However there are some transmissions you should never intentionally listen to. These include: Telephone conversations (either cellular, cordless, or other private means of telephone signal transmission) Pa ...

  • Moen 200-0564 - page 5

    (such as Cat. No. 23-125) to power the scanner. To charge or recharge nickel-cadmium batteries, however, you must remove them from the scanner and use an external charger (such as Cat. No. 23-134). Note: If you are using a rechargeable scanner battery pack, you must charge it first (see "Charging a Rechargeable Battery Pack" below). Cauti ...

  • Moen 200-0564 - page 6

    adapter meets these specifications. Using an adapter that does not meet these specifications could damage the scanner or the adapter. When you finish using the AC adapter, disconnect it from the AC outlet first. Then disconnect it from the scanner. Plug the adapter's supplied 1.3 mm inner diameter/3.4 mm outer diameter barrel plug into the sca ...

  • Moen 200-0564 - page 7

    rechargeable battery pack (Cat. No. 23-288) while it is in the scanner. To charge the battery pack, simply connect an AC or DC adapter to the scanner's PW R/DC 9V jack. It takes about 14-16 hours to recharge a battery pack that is fully discharged. You can operate the scanner while recharging the battery pack, but the charging time is lengthen ...

  • Moen 200-0564 - page 8

    Use extreme caution when installing or removing an outdoor antenna. If the antenna starts to fall, let it go! It could contact overhead power lines. If the antenna touches a power line, contact with the antenna, mast, cable or guy wires can caused e lectrocution and death! Call the power company to remove the antenna. Do not attempt to do so yourse ...

  • Moen 200-0564 - page 9

    Once you understand a few simple terms we use in this manual and familiarize yourself with your scanner's features, you can put the scanner to work for you. You simply determine the communications you want to receive, then set the scanner to scan those frequencies. A frequency is the tuning location of a station (expressed in kHz or MHz). To f ...

  • Moen 200-0564 - page 10

    BAND - selects a preprogrammed search band. W X - scans through the preprogrammed w eather chann els. PR I - sets and turns on and off priority for 10 priority c hannels. Number Keys - each key has a single-digit label and a range of numbers. U se the digi ts on the keys to enter the n umbers for a chan nel or a frequency . Use the range of numbers ...

  • Moen 200-0564 - page 11

    Up or Down Arrow - indicates the search o r scan direction. W X - appears when you scan the preprogrammed weather channels. Key SYMBOL - appears when you lock the k eypad. AUTO - appears while the scanner automatically stores frequencies i nto channels. M - flashes with a number (1-40) to s how w hich monitor memory y ou are listeni ng to. CH - app ...

  • Moen 200-0564 - page 12

    s tored in a bank, or w hen you try to ent er a frequency during a search w hen all channels are full. L-FULL - appears when 200 frequencies are l ocked out duri ng a band, limit , or direct s earch. A-FULL - appears when you select a full bank whi le auto storing or when y ou finish sorti ng a full bank. AC-XXCH - appears with a number to show how ...

  • Moen 200-0564 - page 13

    3-Error - appears instead of ConnECt when a communications error occurred w hile trans ferring frequencies D ata trans fer stops. UNDERSTANDING BANDS/BANKS/MEMORIES Search Bands Your scanner can tune over 32,000 different frequencies. Many of these frequencies are grouped within permanent memo ry locations called search bands (1-17). Band Search Ra ...

  • Moen 200-0564 - page 14

    For example, if you wanted to search for transmissions between pilots and the control tower at an air show, you could search only the search bands where you are most likely to hear the tra nsmissions (4 and 7). Notes: The scanner can search for transmissions on frequencies that are not stored in any of the search bands. Fo r more information, see & ...

  • Moen 200-0564 - page 15

    Make sure the scanner's antenna is connected before you turn it on. 1. Turn SQUELCH MIN/MAX fully counterclockwise. 2. Turn VOLUME OFF/MAX clockwise until it clicks and you hear a hissing sound. 3. Turn SQUELCH MIN/MAX clockwise, then leave it set to a point just after the hissing sound stops. If the scanner automatically starts scanning chann ...

  • Moen 200-0564 - page 16

    3. Use the number keys to enter the frequency you want to store into that channel (including the decimal point). 4. Press ENTER to store the frequency. Notes: If you entered an invalid frequency in Step 3, the scanner beeps and displays the channel number and Error. Simply repeat Steps 3 and 4. Your scanner automatically rounds the entered fre quen ...

  • Moen 200-0564 - page 17

    Notes: To turn off bank 10, press 0. To turn a bank back on, press its number key again. The bar under the bank number appears. If you select a bank that does not contain any empty channe ls, A-FU LL appears instead of AC-XXCH. To enter new frequencies into this bank, you must delete one or more frequencies stored in it. 3. Press LIMIT. L appears. ...

  • Moen 200-0564 - page 18

    preprogrammed search bands for active frequen cies, then store any that you find into your scanner's channels or monitor memories. Notes: You can use the scanner's delay feature while using band search. During band search, you can manually change the receive mode. Follow these steps to search for and store active frequencies using band se ...

  • Moen 200-0564 - page 19

    selected band, press and hold Up or Down Arrow for about 1 second. Note: If you try to store a frequency in a monitor memory that is already stored in a channel, - dUPL - flashes then M, the channel number, CH, and the frequency flash. If you want to store the frequency anyway, press MON again. 4. To select a different band and search for another a ...

  • Moen 200-0564 - page 20

    the bar under the selected bank number flashes. 2. Using the number keys, enter the search bank number for each limit search range you want to remove or select. When a bank is selected, a bar appears under it. Note: To select bank 10, press 1 then 0. 3. Hold down Up Arrow for about 1 second to search from the lower to the upper limit, or Down Arrow ...

  • Moen 200-0564 - page 21

    You can restore the preprogrammed limit search ranges you replaced b y resetting the scanner. 1. Press PGM. PGM appears. 2. Using the number keys, select the number for the search bank where you want to store a new limit search range. Note: To select bank 10, press 1 then 0. 3. Press LIMIT. SRCH BANK, the selected search bank number, and L appear, ...

  • Moen 200-0564 - page 22

    (in steps of 5, 12.5, or 25 kHz, depending on the band), press and release Up or Down Arrow. W hen the scanner finds an active frequency, it stops searching. To store that frequency in the lowest available channel, simply press ENTER. The scanner stores the frequency, and Up or Down Arrow, the channel number and CH, and the frequency flash twice. T ...

  • Moen 200-0564 - page 23

    frequencies that the scanner cannot tune, and try to search in that range, the scanner beeps and does not search. If you set a search range that crosses over into a range of frequencies that the scanner cannot tune, the scanner searches only up to the limit of tunable frequencies and returns to the starting frequency. SCANNING THE CHANNELS To begin ...

  • Moen 200-0564 - page 24

    5. Press ENTER. The scanner stores the frequency in the selected channel. 6. To move another monitor memory frequency to the next channel, press PGM and repeat Steps 3-5. Moving Frequencies from Monitor Memories to a Bank Your scanner can move all the frequencies you have stored in mo nitor memories into a bank you specify. Notes: If there are more ...

  • Moen 200-0564 - page 25

    2. Use the number keys to enter the channel number or monito r memory number containing the frequency you want to delete. 3. If you are deleting the frequency from a channel, pre ss PGM. If you are deleting the frequency from a monitor memory, press MON. 4. Press 0, then press ENTER. The frequency is deleted. 5. To delete more frequencies, repeat S ...

  • Moen 200-0564 - page 26

    frequencies you want to sort. 3. Hold down ENTER, then press Up Arrow to sort channels from the lowest to the highest frequency, or press Down Arrow to sort channels from the highest to the lowest frequency. As the scanner sorts the frequencies, Sor. appears on the display. LISTENING TO MONITOR MEMORIES To listen to a monitor memory, press MANUAL, ...

  • Moen 200-0564 - page 27

    resumes scanning or searching. You can program a 2-second delay in any of these ways: If the scanner is scanning and stops on an active channel, quickly press DELAY before it starts to scan again. If the desired channel is not selected, manually select the channel then press DELAY. If the scanner is searching, press DELAY during the search. DLY app ...

  • Moen 200-0564 - page 28

    4. Press L/OUT. The frequency you want to remove the lockout from disappears. If there is another locked-out frequency, it appears on the display. If there are no more locked-out frequencies, the scanner continues searching. Reviewing Locked-Out Channels/Frequencies To review the channels you lock out, press MANUAL, then repeatedly press L/O RVW. A ...

  • Moen 200-0564 - page 29

    If you want to store the frequency anyway, press ENTER a gain. 5. Repeat Steps 2-4 to store more frequencies into the priority channels (up to 10 channels.) To turn on the priority feature, press PRI when the scanner is in the scan or manual mode. Pri -On- and PRI appear on the display. The scanner checks the priority channels every 2 seconds. It s ...

  • Moen 200-0564 - page 30

    scanner no longer uses any of the preset receive modes. Instead, the scanner uses the selected mode to search for frequencies in all bands. To return to the default settings, hold down CLEAR, then press AM/FM. USING THE DISPLAY BACKLIGHT You can turn on the display's backlight for easy viewing dimly-lit areas. Press LIGHT to turn on the displa ...

  • Moen 200-0564 - page 31

    Handle the scanner gently and carefully. Dropping it can damage circuit boards and cases and can cause the scanner to work improperly. Use only fresh batteries of the recommended size and type. Always remove old and weak batteries. They can leak chemicals that destroy electronic circuits. Use and store the scanner only in normal temperature environ ...

  • Moen 200-0564 - page 32

    ma nually. Keypad does Keylock is turned on. Turn off keylock. not work. Error appears Programming error. Enter the frequency on the display correctly, including the decimal point. Keys do not work Undetermined error. Turn the scanner off or display changes. then on again, or r eset the sca nner. Scanner is on SQUELCH is not Adjust SQUELCH but will ...

  • Moen 200-0564 - page 33

    2. While holding down CLEAR, insert a pointed object, such as a straightened paper clip, into the reset opening on the side of the scanner. Then gently press and release the reset button inside the opening. Note: You must release the reset button before you release CLEAR. Otherwise, the memory might not clear. 3. When the display reappears, release ...

  • Moen 200-0564 - page 34

    380-512 MH z........... ................ .............. ............ ..1 uV 806-960 MH z........... ................ .............. ............ ..2 uV AM 29-54 MHz ............... ................ .............. ............ 2 uV 108-136.9 75 MHz.......... .............. .............. ............. 2 uV 137-174 MH z........... ................ .. ...

  • Moen 200-0564 - page 35

    Built-in Speaker........................................1 3/8 Inch (36 mm) 8- ohm, Dynamic Type Power Requirements..................................................+9 VDC 6AA ba tteries AC Adapter ( Cat. No. 273-16 65) DC Adapt er (Cat. No. 270- 1560) Rechargeable Battery Pack (Cat. No. 23-288) Battery Life.........................18.5 Hours (using ...

Manufacturer Moen Category Scanner

Documents that we receive from a manufacturer of a Moen 200-0564 can be divided into several groups. They are, among others:
- Moen technical drawings
- 200-0564 manuals
- Moen product data sheets
- information booklets
- or energy labels Moen 200-0564
All of them are important, but the most important information from the point of view of use of the device are in the user manual Moen 200-0564.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Moen 200-0564, service manual, brief instructions and user manuals Moen 200-0564. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Moen 200-0564.

Similar manuals

A complete manual for the device Moen 200-0564, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Moen 200-0564 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Moen 200-0564.

A complete Moen manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Moen 200-0564 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Moen 200-0564, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Moen 200-0564, that we can find in the current document
3. Tips how to use the basic functions of the device Moen 200-0564 - which should help us in our first steps of using Moen 200-0564
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Moen 200-0564
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Moen 200-0564 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Moen 200-0564?

Use the form below

If you did not solve your problem by using a manual Moen 200-0564, ask a question using the form below. If a user had a similar problem with Moen 200-0564 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)