Manual Kathrein MSK 200/S2

24 pages 0.49 mb
Download

Go to site of 24

Summary
  • Kathrein MSK 200/S2 - page 1

    User Manual Antenna signal meter system MSK 200/S2 ...

  • Kathrein MSK 200/S2 - page 2

    2 PREF ACE/IMPORT ANT NOTES Dear customer , We kindly ask you to observe all instructions contained in this manual. The Kathrein-Werke KG has made every effort to ensure that the data and descriptions in this manual are accurate and complete. We reserve the right to make changes to this manual without prior notice. This particularly applies to modi ...

  • Kathrein MSK 200/S2 - page 3

    3 CONTENT PREF ACE/IMPORT ANT NOTES ................................................................................................. 2 GENERAL SAFETY INFORMA TION .......................................................................................... 2 CONTENT ..................................................................................... ...

  • Kathrein MSK 200/S2 - page 4

    4 SAFETY This device was built and tested in accordance with the enclosed EU certi fi cate of conformity and left the factory in a condition full fi lling all requisite safety regulations. T o ensure that this condition is maintained and to ensure hazard-free operation, the user must observe all in- structions, warnings and warning notes. Symbols ...

  • Kathrein MSK 200/S2 - page 5

    5 SAFETY 5. Prior to switching on the device, ensure that the nominal mains voltage set on the device and the nominal mains voltage of the supply match. If it is necessary to change the voltage setting, it may also be necessary to change the respective mains fuse for the device. 6. In case of devices in protection class I with a fl exible mains ca ...

  • Kathrein MSK 200/S2 - page 6

    6 FEA TURES/DELIVER Y SCOPE The MSK 200 is a compact state-of-the-art signal meter which leaves nothing to be desired when you are checking antenna and cable systems or even professional head-end systems. It can be used either in a lab or for the monitoring of remote-controlled head-end systems, or for fi nal measurements on antenna and distributi ...

  • Kathrein MSK 200/S2 - page 7

    7 OPERA TION INITIAL ST ART -UP Prior to operating for the fi rst time, please take the T 8.0 A fuse out of the packaging and fi t it into the provided fuse holder . The fuse prevents the device being switched on unintentionally during transport. Caution! Please remove this fuse again before shipping the device! Remove the AC power supply unit (1 ...

  • Kathrein MSK 200/S2 - page 8

    8 USING THE DEVICE ON THE SHOULDER STRAP When the device is used on the strap, also provide for adequate ventilation! T o avoid a build up of heat, the openings for the fan and the ventilation holes must always be clear . OPERA TION For right-handed users Pass the shoulder strap over your right shoulder! For left-handed users Pass the shoulder stra ...

  • Kathrein MSK 200/S2 - page 9

    9 GENERAL OPERA TION KEYBOARD OPERA TION SETTINGS: SA VE, SETUP , COPY , PRINT Switching the device ON/OFF , or to standby mode. If the button is kept pressed more than 5 seconds, the device is switched off. Switching the SOFTKEYS ON/OFF , zooming in the graphic display SELECTING SOURCES: SA T analogue, SA T digital, CA TV analogue, CA TV digital, ...

  • Kathrein MSK 200/S2 - page 10

    10 GENERAL OPERA TION TOUCHSCREEN OPERA TION T ap on the touchscreen keys to select the respective task! SOURCES Selection (SOURCE) Measurement Selection (ANAL YZE) When the “SOURCE“ button is pressed, the source selection buttons appear , which can be used to select the signal path! When the “ANAL YZE” key is pressed, the measure- ment sel ...

  • Kathrein MSK 200/S2 - page 11

    11 GENERAL OPERA TION This type of key leads to a selection of various set- tings (e.g. selection of the channel)! This type of key offers the facility for alphanumerical input (e.g.: entering programme names)! This type of key offers the facility for numerical input (e.g.: entering programme numbers) T ap on the screen to set the markers directly ...

  • Kathrein MSK 200/S2 - page 12

    12 GENERAL OPERA TION T o open the zoom window , press and hold your fi n- ger on the marker; you can then shift it to the desired position! Press the “FUNCTION“ key , tap on the screen and hold to drag the screen section as required (e.g.: the delay time on the oscilloscope, the mid-frequency on the spectrum analyser)! This type of key indica ...

  • Kathrein MSK 200/S2 - page 13

    13 OPERA TION CHOICE OF THE SIGNAL SOURCE AND MEASUREMENT The most important keys on the MSK 200 are and . After activating the key , you will be able to de fi ne the source and the channel or transponder to be measured. After pressing the key , you will be able to choose the type of measurement wanted and have this carried out. In the MSK 200‘s ...

  • Kathrein MSK 200/S2 - page 14

    14 OPERA TION CHOOSING THE CHANNEL T O BE MEASURED Now one can choose the channel to be measured: Generally there are different possibilities of fered as to how a measurement channel can be chosen 1. Selection of programme through programme name 1.1. Press “Chan.T ab“ to select the desired channel table 1.2. Enter the desired programme name in ...

  • Kathrein MSK 200/S2 - page 15

    15 OPERA TION Information on the individual measurement possibilities can also be found in the on-board help menus. Generally an optimal pre-setting of parameters is saved in the MSK 200 for each type of measurement. There are though many other set-up possibilities that can be carried out dependant on the measurement in question. These can be viewe ...

  • Kathrein MSK 200/S2 - page 16

    16 FUNCTION OVER VIEW Mains external AC power supply unit 100...240 V Battery internal Li-Ion battery 12 V/6,5 AH external battery supply vehicle 1 1 V ...16 VDC keyboard 12 hardkeys On/Off, Help, Prog.+, Prog.-, Analyze, Source, OSD/Off, V ol.+, V ol.-, Copy , Function, Extend external keyboard ASCII keyboard (PS2) to enter ASCII characters T ouch ...

  • Kathrein MSK 200/S2 - page 17

    17 FUNCTION OVER VIEW TV (CA TV/terrestrial) 5...900 MHz Satellite 900....3100 MHz FM 87,5...108 MHz Spectrum analysis 5...3100 MHz Digital CA TV J83 A/C (DVB-C) 16, 32, 64, 128 ,256 QAM J83 B 64 QAM DOCSIS 64, 256 QAM Analogue CA TV P AL, NICAM B/G, I, D/K, L/L´, M/N NTSC, NICAM B/G, I, D/K, L/L´, M/N SECAM, NICAM B/G, I, D/K, L/L´, M/N Digital ...

  • Kathrein MSK 200/S2 - page 18

    18 TECHNICAL APPENDIX DESIGN • Manageable portable signal meter • High-resolution 10.4“ TFT colour display to graph analogue and digital TV signals and graphics • Backlight - thus the display is excellently readable also in bright sunlight (typ. 600 cd/m 2 ) • Easy operation using 12 hard keys and through the infrared touch screen for men ...

  • Kathrein MSK 200/S2 - page 19

    19 T ype MSK 200/S2 MSK 200/S2 Order no. 21710024 21710025 Spectrum analyser Frequency range MHz 5-3100 Resolution bandwidth (-3 dB) MHz 0.001-10 Resolution bandwidth (-6 dB) kHz 9, 25, 50, 120, 200 Video bandwidths MHz 0.00001-3 Phase noise at 10 kHz carrier level spacing dBc <-90 (1 Hz), typ. -95 (1 Hz) Phase noise at 100 kHz carrier level spa ...

  • Kathrein MSK 200/S2 - page 20

    20 TECHNICAL APPENDIX Digital CA TV receiver (J83 A, B, C) Modulation type 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM Symbol frequency MSymb/s 2.0-6.999 Frequency increment kHz 50 Video output voltage/impedance V ss / Ω 1/75 ± 1 dB IF bandwidths MHz 1, 5, 6, 7, 8, 12 MER measurement dB > 33/typ. 38 Digital terrestrial TV receiver (DVB-T , A TSC) ...

  • Kathrein MSK 200/S2 - page 21

    21 TECHNICAL APPENDIX Connections RF input standarad (impedance) Ω 1.6/5.6 (75) N-type socket (50) Composite colour picture input/output, RGB output Scart socket Video input/output 2 x BNC socket T ransport current input/output 2 x Sub D socket (25-pole) ASI input/output 2 x BNC socket Common interface/card reader 1/1 PCMCIA slot 1 Interconnection ...

  • Kathrein MSK 200/S2 - page 22

    22 SER VICE DEVICE CALIBRA TION Device maintenance is essentially limited to cleaning the exterior . The calibration interval is dependent on operational demands made on it and should be carried out every 1 to 2 years. The calibration can be carried out by ESC Kathrein customer service, see below . EXTERIOR CLEANING Clean the exterior of the device ...

  • Kathrein MSK 200/S2 - page 23

    23 SER VICE If, despite studying this operating manual, you still have questions about getting started with the unit or using it correctly , or if unexpected problems occur , please contact your specialist dealer . MAIN SERVICES www .esc-Kathrein.de Fa. ESC Elektronik Service Chiemgau GmbH Bahnhofstr . 108 83224 Grassau E-Mail: service@esc-kathrein ...

  • Kathrein MSK 200/S2 - page 24

    Internet: http://www .kathrein.de KA THREIN-Werke KG • Anton-Kathrein-Straße 1 - 3 P .O. Box 10 04 44 • 83004 Rosenheim/GERMANY 936.3 448 / - / 10 08/ZWT - T echnical data subject to change! ...

Manufacturer Kathrein Category Car Stereo System

Documents that we receive from a manufacturer of a Kathrein MSK 200/S2 can be divided into several groups. They are, among others:
- Kathrein technical drawings
- MSK 200/S2 manuals
- Kathrein product data sheets
- information booklets
- or energy labels Kathrein MSK 200/S2
All of them are important, but the most important information from the point of view of use of the device are in the user manual Kathrein MSK 200/S2.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Kathrein MSK 200/S2, service manual, brief instructions and user manuals Kathrein MSK 200/S2. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Kathrein MSK 200/S2.

A complete manual for the device Kathrein MSK 200/S2, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Kathrein MSK 200/S2 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Kathrein MSK 200/S2.

A complete Kathrein manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Kathrein MSK 200/S2 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Kathrein MSK 200/S2, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Kathrein MSK 200/S2, that we can find in the current document
3. Tips how to use the basic functions of the device Kathrein MSK 200/S2 - which should help us in our first steps of using Kathrein MSK 200/S2
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Kathrein MSK 200/S2
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Kathrein MSK 200/S2 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Kathrein MSK 200/S2?

Use the form below

If you did not solve your problem by using a manual Kathrein MSK 200/S2, ask a question using the form below. If a user had a similar problem with Kathrein MSK 200/S2 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)