    © 2007 - 2012 Goodman Manufacturing Compa ny , L.P . 5151 San Felipe, Suite 500, Houston, TX 77056 www .goodmanmfg.com - or - www .amana-hac.com P/N: IO-431 Date: May 2012 ASPF AIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION. A TTENTION INST ALLING PERSONNEL Prior to installation, thoroughly fami ...

  • Goodman Mfg ASPF Air Handlers - page 2

    2 Important Safety Instructions The following symbols and labels are used throughout this manual to indicate immediate or potential safety hazards. It is the owner’s and installer’s responsibility to read and com- ply with all safety information and instructions accompanying these symbols. Failure to heed safety information increases the risk o ...

  • Goodman Mfg ASPF Air Handlers - page 3

    3 IMPORTANT: To register your Goodman ® brand unit, go to www.goodmanmfg.com and click on “Warranty Registration”. Complete registration as prompted. To register your Amana ® brand unit, go to www.amana- hac.com and click “Warranty Registraion”. Complete regis- tration as prompted. Product limited warranty certificates for models currentl ...

  • Goodman Mfg ASPF Air Handlers - page 4

    4 Return Ductwork DO NOT TERMINATE THE RETURN DUCTWORK IN AN AREA THAT CAN INTRODUCE TOXIC, OR OBJECTION- ABLE FUMES/ODORS INTO THE DUCTWORK. The return ductwork is to be introduced into the air handler bottom (upflow configuration). Return Air Filters Each installation must include a return air filter. This filtering may be performed at the air ha ...

  • Goodman Mfg ASPF Air Handlers - page 5

    5 H I G H V O LTA G E ! Fail ure to do so may cause prop ert y dama ge , pe r s o n a l i n ju r y or dea t h . Dis connec t ALL pow er befor e s ervi cing. Multiple p ower sourc es may be present. HIG H VOL T A GE! T o avoid prope rty dama ge , persona l injury or death du e to elect ri ca l sho c k, th is uni t MU S T ha ve an ele c trical ground ...

  • Goodman Mfg ASPF Air Handlers - page 6

    6 Low Voltage Connections Several combinations of low voltage schemes are available, depending on the presence of a heat kit and whether the heat kit is single-stage or multi-staging. The low voltage con- nections are determined by whether the outdoor unit is a con- denser or heat pump. The 24V-control voltage connects the air handler to the room t ...

  • Goodman Mfg ASPF Air Handlers - page 7

    7 Downflow Conversion Conversion to downflow MUST be performed in an area that allows access to all sides prior to placing the air handler in its final location. To prevent the evaporator coil pan from “sweat- ing” the DPI accessory insulation kit is to be used when per- forming this conversion. NOTE : The DPI kit is not supplied with this prod ...

  • Goodman Mfg ASPF Air Handlers - page 8

    8 ASPF Model Insulation Kit 1830 DPI H36-42 3137 / 42 60 DPIH48-6 1 Table 8 The following describes converting to “Horizontal Left-Hand”. Conversion MUST be performed in an area that allows ac- cess to all sides prior to placing the air handler in its final location ( See Figure 6 ). PRIM ARY DRAIN SECOND ARY DRAIN DPIH K I T Figure 6 1. Remove ...

  • Goodman Mfg ASPF Air Handlers - page 9

    9 Use of a condensate removal pump is permitted when nec- essary. This condensate pump should have provisions for shutting off the control voltage should a blocked drain occur. A trap must be installed between the unit and the conden- sate pump. IMPORTANT NOTE: The evaporator coil is coated with oils that may dissolve styrofoam and certain types of ...

  • Goodman Mfg ASPF Air Handlers - page 10

    10 ASPF Thermostat Connections NOTES: 1) OUTDOOR THERMOSTAT (OT-1) SHOULD BE THE FIRST TO CLOSE AND THE LAST TO OPEN. 2) JUMPER W1 AND W2 TOGETHER IF OT-2 IS NOT USED. 3) REMOVE WIRE WHEN USING OUTDOOR THERMO- STAT. NOMENCLATURE: OT - OUTDOOR THERMOSTAT (OPTIONAL) EHR - EMERGENCY HEAT RELAY (OPTIONAL) COLOR CODES RD - RED YL - YELLOW BL - BLUE BR - ...

  • Goodman Mfg ASPF Air Handlers - page 11

    11 HIGH VOL T AGE ! DIS CO NNE CT A LL POW ER BE FO RE SERV ICI NG. MUL TIPLE PO WE R S OURC ES MA Y B E P RES EN T . F AILUR E T O DO SO MA Y C AU SE PR OPERT Y DA MAGE , P ER SON AL I NJU R Y OR DE A TH . WA R N I N G Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. YG W W2 R COOLIN G U N ...

  • Goodman Mfg ASPF Air Handlers - page 12

    12 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. HIGH VOL T AGE ! DIS CO NNE CT A LL POW ER BE FO RE SERV ICI NG. MUL TIPLE PO WE R S OURC ES MA Y B E P RES EN T . F AILUR E T O DO SO MA Y C AU SE PR OPERT Y DA MAGE , P ER SON AL I NJU R Y OR DE A TH . WA R N I N G G C R HEA T PUMP UNIT ...

  • Goodman Mfg ASPF Air Handlers - page 13

    13 HIGH VOL T AGE ! DIS CO NNE CT A LL POW ER BE FO RE SERV ICI NG. MUL TIPLE PO WE R S OURC ES MA Y B E P RES EN T . F AILUR E T O DO SO MA Y C AU SE PR OPERT Y DA MAGE , P ER SON AL I NJU R Y OR DE A TH . WA R N I N G Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. ASPF Wiring Diagram BK ...

  • Goodman Mfg ASPF Air Handlers - page 14

    14 THIS P AGE LEFT INTENTIONALL Y BLANK ...

  • Goodman Mfg ASPF Air Handlers - page 15

    15 SPLIT SYSTEMS AIR CONDITIONING AND HEA T PUMP HOMEOWNER’S ROUTINE MAINTENANCE RECOMMENDA TIONS We strongly recommend a bi-annual maintenance checkup be performed before the heating and cooling seasons begin by a qualified servicer . Replace or Clean Filter IMPORTANT NOTE: Never operate unit without a filter in- stalled as dust and lint will bu ...

  • Goodman Mfg ASPF Air Handlers - page 16

    16 © 2007 - 2012 Goodman Manufacturing Company , L.P . 5151 San Felipe, Suite 500, Houston, TX 77056 www .goodmanmfg.com - or - www .amana-hac.com NOTE: SPECIFICATIONS AND PERFORMANCE DATA LISTED HEREIN ARE SUBJECT TO CHANGE WITHOUT NOTICE. ...

Manufacturer Goodman Mfg Category Wheelchair

Documents that we receive from a manufacturer of a Goodman Mfg ASPF Air Handlers can be divided into several groups. They are, among others:
- Goodman Mfg technical drawings
- ASPF Air Handlers manuals
- Goodman Mfg product data sheets
- information booklets
- or energy labels Goodman Mfg ASPF Air Handlers
All of them are important, but the most important information from the point of view of use of the device are in the user manual Goodman Mfg ASPF Air Handlers.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Goodman Mfg ASPF Air Handlers, service manual, brief instructions and user manuals Goodman Mfg ASPF Air Handlers. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Goodman Mfg ASPF Air Handlers.

A complete manual for the device Goodman Mfg ASPF Air Handlers, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Goodman Mfg ASPF Air Handlers by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Goodman Mfg ASPF Air Handlers.

A complete Goodman Mfg manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Goodman Mfg ASPF Air Handlers - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Goodman Mfg ASPF Air Handlers, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Goodman Mfg ASPF Air Handlers, that we can find in the current document
3. Tips how to use the basic functions of the device Goodman Mfg ASPF Air Handlers - which should help us in our first steps of using Goodman Mfg ASPF Air Handlers
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Goodman Mfg ASPF Air Handlers
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Goodman Mfg ASPF Air Handlers in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Goodman Mfg ASPF Air Handlers?

Use the form below

If you did not solve your problem by using a manual Goodman Mfg ASPF Air Handlers, ask a question using the form below. If a user had a similar problem with Goodman Mfg ASPF Air Handlers it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)