Manual Axis Communications B 230 V AC

20 pages 1.14 mb
Download

Go to site of 20

Summary
  • Axis Communications B 230 V AC - page 1

    INSTALLATION GUIDE ENGLISH DEUTSC H ITALIANO ESPAÑOL FRAN Ç AIS AXIS Electrical Safety Kit A 120 V AC AXIS Electrical Safety Kit B 230 V AC ...

  • Axis Communications B 230 V AC - page 2

    Electrical Safety: Low Voltage Directive (LVD) Europe - This equipment complies with the Low Voltage Directive 2006/95/EC. Safety For safety informati on regarding the components of this kit, see Technical Specifications, o n page 15. Equipment Modifications This equipment must be installed and used in strict acco rdance with th e instructions give ...

  • Axis Communications B 230 V AC - page 3

    ENGLISH Safeguards Please read through this Installation Guide carefully be fore installing the Axis product. Ke ep the Installa tion Guide for further reference . • Store the Axis product in a dry and ventilated environment. • Avoid exposing the Axis product to vibration, shocks or heavy pressure. Do not install the product on unstable bracket ...

  • Axis Communications B 230 V AC - page 4

    ...

  • Axis Communications B 230 V AC - page 5

    AXIS Electr ical Safety Kit A/B Page 5 ENGLISH AXIS Electrical Safety Kit A/B Installation Guide This Installation Guide provides instru ctions for installing AXIS Electrical Safety Kit A 120 V AC and AXIS Electr ical Safety Kit B 230 V AC in AXIS T98A-VE Surveillance Cabinet Series. The purpose of this kit is to prov ide surge protection, a fuse a ...

  • Axis Communications B 230 V AC - page 6

    Page 6 AXIS Electr ical Safet y Kit A/B Hardware Overview In this document PE, Protective Earth, and Ground are referred to as ground. 1 2 3 4 5 7 6 1 MCB fuse 4 A (Circuit bre aker) 2 Surge protector 4 A 3 Terminal block – feed-through (blue) 4 Terminal block – ground (green/yellow) 5 Terminal block – ground (green/yellow) 6 Door switch 7 Do ...

  • Axis Communications B 230 V AC - page 7

    AXIS Electr ical Safety Kit A/B Page 7 ENGLISH Connection Diagram • If an external protective bonding wire is used it is recom- mended to have a miminum area of 6 mm 2 (AWG 10) for indoor use and a minimum area of 10 mm 2 (AWG 8) for outdoor use. • The circuitry shall be connected to an external double pole cir- cuit breaker in the building ins ...

  • Axis Communications B 230 V AC - page 8

    Page 8 AXIS Electr ical Safet y Kit A/B • Check the surge protector after lig htning strikes and replace if required. See Replace the Surge Protector, on page 14. • An additional fuse may be required in regions with severe light- ning strikes. To preven t unwant ed triggering of the fuse, a higher rated fuse may replace th e 4 A MCB fuse, follo ...

  • Axis Communications B 230 V AC - page 9

    AXIS Electr ical Safety Kit A/B Page 9 ENGLISH Install the Devices • The electrical connections and conduit installat ions shall be made by a certified electricia n and in compliance with local regulations. • Risk of electric shock. The main s supply shall be disconnected during installation. • Keep the wires short but do not stretch them. Sh ...

  • Axis Communications B 230 V AC - page 10

    Page 10 AXIS Electrical Safety Kit A/B Example: AXIS Electrical Safety Kit A 120 V AC 1 0 L N PE 4 A 1 6 7 9 8 2 3 4 5 1 Circuit breaker 2 Surge protector 3 Terminal block – feed-through (blue) 4 Terminal block – ground (green/yellow) 5 Terminal block – ground (green/yellow) 6L L i n e c o n n e c t i o n 7 N Neutral connection 8 Ground conne ...

  • Axis Communications B 230 V AC - page 11

    AXIS Elect rical Safe ty Kit A/B Page 11 ENGLISH Example: AXIS Electrical Safety Kit B 230 V AC PE 1 0 LN 4 A 1 6 7 9 8 2 3 4 5 1 Circuit breaker 2 Surge protector 3 Terminal block – feed-through (blue) 4 Terminal block – ground (green/yellow) 5 Terminal block – ground (green/yellow) 6L L i n e c o n n e c t i o n 7 N Neutral connection 8 Gro ...

  • Axis Communications B 230 V AC - page 12

    Install the Door Swit ch The door switch included with the elec trical safety kit can be connected to the I/O port on a camera or an I/O device. See the camera’s Installation Guide and User Manual for information about connecting and configuring the camera’s I/O port. 1. Connect either of the connectors on the door switch cable to the common te ...

  • Axis Communications B 230 V AC - page 13

    AXIS Elect rical Safe ty Kit A/B Page 13 ENGLISH 4. If connecting to the I/O port on a camera, route the door switch cable through a cable gasket and at tach the cabl e gaske t to one of the cable holes in the cabinet door. 5. Secure the cable to the door using the supplied cable clip. 6. Connect the door switch cable to the I/O port on the camera ...

  • Axis Communications B 230 V AC - page 14

    Page 14 AXIS Electrical Safety Kit A/B Replace the Surge Protector The surge protector gets worn out by surges. The window on the surge protector shows the status of the device. 1. When the entire window is red, pull out the module and replace it. on res alarm on res alarm ...

  • Axis Communications B 230 V AC - page 15

    AXIS Elect rical Safe ty Kit A/B Page 15 ENGLISH Technical Specifications General Function/group Item Specifications General Environment In a cas ing for indoor or outdoor use Pollution Degree 2 Door switch Ap provals EN61058 UL1054 Operating conditions -40 ºC to +85 ºC (-40 ºF to 185 ºF) Humidity 15 – 10 0% RH Terminal blocks Approvals UL105 ...

  • Axis Communications B 230 V AC - page 16

    Page 16 AXIS Electrical Safety Kit A/B AXIS Electrical Safety Kit A 120 V AC Function/group Item Specifications Circuit breaker/fuse Rated current 4A at 30°C (8 6°F) Operating voltage Max 277 V AC Rated frequencey 50/60 Hz Rated short- circuit capacity 10 kA Tripping curve K Approvals IEC/EN 60947-2 UL 489 CSA 22.2 No. 5 Operating conditions -40 ...

  • Axis Communications B 230 V AC - page 17

    AXIS Elect rical Safe ty Kit A/B Page 17 ENGLISH AXIS Electrical Safety Kit B 230 V AC Function/group Item Specifications Circuit breaker/fuse Rated current 4A at 30°C (86°F) Operating voltage Max 253 V AC Rated frequencey 50/60 Hz Rated short- circuit capacity 6 kA Tripping curve C Approvals IEC/EN 60898-1 IEC/EN 60947-2 UL 1077 CSA 22.2 No. 235 ...

  • Axis Communications B 230 V AC - page 18

    Page 18 AXIS Electrical Safety Kit A/B Warranty For information about Axis’ produ ct warranty and thereto related information, see www.axis.com/warranty ...

  • Axis Communications B 230 V AC - page 19

    ...

  • Axis Communications B 230 V AC - page 20

    Installation Guide Ver.2.10 AXIS Electrical Safety Kit A/B Printed: October 2012 © Axis Communications AB, 2012 Part No. 48993 ...

Manufacturer Axis Communications Category Marine Safety Devices

Documents that we receive from a manufacturer of a Axis Communications B 230 V AC can be divided into several groups. They are, among others:
- Axis Communications technical drawings
- B 230 V AC manuals
- Axis Communications product data sheets
- information booklets
- or energy labels Axis Communications B 230 V AC
All of them are important, but the most important information from the point of view of use of the device are in the user manual Axis Communications B 230 V AC.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Axis Communications B 230 V AC, service manual, brief instructions and user manuals Axis Communications B 230 V AC. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Axis Communications B 230 V AC.

A complete manual for the device Axis Communications B 230 V AC, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Axis Communications B 230 V AC by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Axis Communications B 230 V AC.

A complete Axis Communications manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Axis Communications B 230 V AC - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Axis Communications B 230 V AC, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Axis Communications B 230 V AC, that we can find in the current document
3. Tips how to use the basic functions of the device Axis Communications B 230 V AC - which should help us in our first steps of using Axis Communications B 230 V AC
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Axis Communications B 230 V AC
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Axis Communications B 230 V AC in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Axis Communications B 230 V AC?

Use the form below

If you did not solve your problem by using a manual Axis Communications B 230 V AC, ask a question using the form below. If a user had a similar problem with Axis Communications B 230 V AC it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)