Manual Agilent Technologies 60501B

11 pages 0.1 mb
Download

Go to site of 11

Summary
  • Agilent Technologies 60501B - page 1

    OPERATING MANUAL 150 WATT ELECTRONIC LOAD MODULE Agilent Model 60501B FOR MO DULES WITH SERIAL NUMBERS: 3118A -00101 A ND A BOVE A gilent Part No. 60501-90009 Printed in U.S.A . Microf iche No. 60501-90010 June, 1991 ...

  • Agilent Technologies 60501B - page 2

    DECLA RA TION OF CONFORMI TY according to IS O/IEC G uide 22 and E N 45014 Manufacturer’s Name : Agilent Tec hnologies Manuf acturer’s A ddress: New Jersey Divi sion 140 Green Pond Road Rock away , NJ 07866 U.S.A. declares that the pr oduct Product Name: Load mainf ram e and m odules Model Number(s): Agilent 6050A, 6051A mainf ram es with m odu ...

  • Agilent Technologies 60501B - page 3

    1 150-Watt Module About This Manual This m anual provides in form ation for t he Ag ilent 60501B 150- Watt Electron ic Load Modul e. It is desig ned as a supplem ent to the A gilent 6050A /6051A Mu ltiple Input Mainf rame Electron ic Load Operating Man ual (part nu mber 06050- 90001). Four tabl es provide th e follow ing modu le-specif ic inf ormat ...

  • Agilent Technologies 60501B - page 4

    2 Table 60501-1. Specification and Supplemental Characteristics SPECIFICA TIO NS DC Input Rating: Current: 0 to 30 A Voltage : 3 to 60 V (min imu m dc operat ion from 0 to 2 V for 0 t o 30 A) Pow er: 150 W at 40 ° C (derated to 112 W at 55 ° C) A . OPERA TING CHARA CTERISTICS B. DERA TED CURRENT DETAIL Constant Current Mode: Ranges: 0 to 3 A; and ...

  • Agilent Technologies 60501B - page 5

    3 Table 60501-1 Specifications and Supplemental Characteristics (continued) Transient Operat ion: Continuous Mode Frequency Range: 0.25 Hz to 10 kHz Frequency Resolution: 4% Frequency A ccuracy : 3% Duty Cy cle Range: 3% to 97% (0.25 Hz to 1 k Hz); 6% to 94% (1 k Hz to 10 kHz) Duty Cy cle Resolution: 4% Duty Cycle A ccuracy : 6% of set ting ± 2% P ...

  • Agilent Technologies 60501B - page 6

    4 Table 60501-1 Specifications and Supplemental Characteristics (continued) External A nalog Programming 0 to 10 V (dc or ac): Bandwidth: 10 kHz (3 db freque ncy ) A ccuracy: ± 4.5% ± 40 m A (0 t o 3 A rang e) ± 4.5% ± 130 m A (0 to 30 A range) ± 0.8% ± 200 mV (0 to 60 V range) Temperature Coeffic ient: 100 ppm/ ° C ± 3 mA/ ° C (cu rrent r ...

  • Agilent Technologies 60501B - page 7

    5 Table 60501-1 Specifications and Supplemental Characteristics (continued) Current Slew Rate:* Rate # 30 A Range Step 3 A Range Step Transition T ime 1 0.5 A/m s 0.05 A/s 8.0 ms 2 1.2 A/m s 0.12 A/s 3.2 ms 3 2.5 A/m s 0.25 A/m s 1.6 ms 4 5 A/m s 0.5 A/m s 800 µ s 5 12 A/m s 1.2 A/m s 320 µ s 6 25 A/m s 2.5 A/m s 160 µ s 7 0.05 A/ µ s 5 A /m s ...

  • Agilent Technologies 60501B - page 8

    6 Table 60501-1 Specifications and Supplemental Characteristics (continued) Source Turn-On Current Overshoot: Less than 10% of fin al value (in CC and CR m odes w hen connected to pow er supplies with voltage rise times of greater than 500 µ s). Programmable Shor t Circuit: 0.066 Ω (0.04 Ω typical) Programmable Open Circuit: 20 k Ω (ty pical ...

  • Agilent Technologies 60501B - page 9

    7 Table 60501-2. Programming Ranges (continued) Transient O peration Set Frequency FREQ value " T RAN:FREQ value" 0.25 Hz to 10 kHz Set Duty Cy cle (shif t) DCYCLE v alue "TRAN: DCYC va lue" 3-97% (0.25 Hz- 1 kHz) 6-94% (1 k Hz-10 kH z) *S et Puls e Width "TRAN:TWID valu e" 0.00005 to 4 s Trigger Operat ion *S et Trigg ...

  • Agilent Technologies 60501B - page 10

    8 Table 60501-4. Calibration Info rmation Ranges and Calibration Points Variables Variables Value Power Supply Settings Current Shunt High C urrent R ange Hi_cu rr_rng 30 5 V/31 A 100 A High C urrent Of fset Hi_curr_off set 0.013 Low Cu rrent Ran ge Lo_curr_rn g 3 5 V/10 A 15 A Low Curren t Off set L o_curr_off set 0.013 Voltage Range N/A N/A 61 V/ ...

  • Agilent Technologies 60501B - page 11

    9 Agilent Sales and Support Office For more information about Agilent Technologies test and measurement products, applications, services, and for a current sales office listing, visit our web site: http://www.agilent.com/find/tmdir You can also contact one of the following centers and ask for a test and measurement sales representative. United Stat ...

Manufacturer Agilent Technologies Category Drums

Documents that we receive from a manufacturer of a Agilent Technologies 60501B can be divided into several groups. They are, among others:
- Agilent Technologies technical drawings
- 60501B manuals
- Agilent Technologies product data sheets
- information booklets
- or energy labels Agilent Technologies 60501B
All of them are important, but the most important information from the point of view of use of the device are in the user manual Agilent Technologies 60501B.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Agilent Technologies 60501B, service manual, brief instructions and user manuals Agilent Technologies 60501B. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Agilent Technologies 60501B.

A complete manual for the device Agilent Technologies 60501B, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Agilent Technologies 60501B by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Agilent Technologies 60501B.

A complete Agilent Technologies manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Agilent Technologies 60501B - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Agilent Technologies 60501B, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Agilent Technologies 60501B, that we can find in the current document
3. Tips how to use the basic functions of the device Agilent Technologies 60501B - which should help us in our first steps of using Agilent Technologies 60501B
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Agilent Technologies 60501B
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Agilent Technologies 60501B in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Agilent Technologies 60501B?

Use the form below

If you did not solve your problem by using a manual Agilent Technologies 60501B, ask a question using the form below. If a user had a similar problem with Agilent Technologies 60501B it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)