  • National Instruments cFP-RTD-122 - page 1

    323348B-01 April 2003 © 2002–2003 Nat ional Instr uments Corp. All ri ghts reserved. FieldPoint ™, National Instruments ™, NI™, and ni. com™ are tradema rks of National I nstruments Cor poration. Produc t and com pany n ames m entioned herein are trad emar ks or trad e names o f their respecti ve com panies . For patent s covering Nation ...

  • National Instruments cFP-RTD-122 - page 2

    FP-RTD-122 and cFP-RTD-122 2 ni.com Installing th e FP-RTD-122 The FP-R TD-122 mounts on a Fie ldPoi nt termin al base (FP-TB - x ), which pro vides operating po wer to the module. Inst alling th e FP-R TD-122 onto a po wered termin al base do es not disru pt the opera tion of the ba nk. T o install the F P-R TD-122, refer to Figure 1 an d complete ...

  • National Instruments cFP-RTD-122 - page 3

    © National Instruments Corp. 3 FP-RTD-122 and cFP-RTD-122 T o install the cFP -R TD-122, refer to Figure 2 and complete the follo wing steps: 1. Alig n the captive screws on the cFP-RTD-122 with the hol es on the bac kplane. The ali gnment keys on the cFP- R TD-12 2 prev ent backward ins ertion. 2. Press firmly to sea t the cFP-R TD-1 22 on the ba ...

  • National Instruments cFP-RTD-122 - page 4

    FP-RTD-122 and cFP-RTD-122 4 ni.com Wiring the [c]FP-R TD-122 The FP-TB- x terminal bases have connection s for each o f the eight input c hannels on the FP-R T D-122. Th e cFP-CB- x co nnector blocks pr ovide the same connect ions for t he cFP-R TD-122. T able 1 li sts t he term inal as sig nment s for t he si gnals asso ciat ed with each cha nnel ...

  • National Instruments cFP-RTD-122 - page 5

    © National Instruments Corp. 5 FP-RTD-122 and cFP-RTD-122 Figure 3 . [c]F P-RTD-122 Inpu t Circuitry T aking Measurements from Three-Wire R TDs Three-wire R TDs often ha ve a wire of one color (usually white, sometimes re d) for po siti ve e xcitation, and tw o wires of another color (usually red, sometim es black). Conn ect the positive ex citati ...

  • National Instruments cFP-RTD-122 - page 6

    FP-RTD-122 and cFP-RTD-122 6 ni.com Figure 5. Fou r -Wire RTD Connection s on One Channel T aking Measurements from T wo-Wire R TDs Connect eith er wire of a two-wire R TD to the EX+ terminal and the other wire to the COM term inal, and co nnect a sho rt jumper wire between th e COM and SENSE terminals. Figure 6. T wo-Wire RTD Connectio ns on One C ...

  • National Instruments cFP-RTD-122 - page 7

    © National Instruments Corp. 7 FP-RTD-122 and cFP-RTD-122 Converting Resistance M easurements to T emperatu re Measureme nts The [c]FP -R TD-122 has b uilt-in line arization algo rithms for platinu m R TDs of ei ther 100 or 1,00 0 Ω no minal resista nce, and for si x TCR (or a lpha, α ) values. The TCR is the av erage temperature co eff icient ...

  • National Instruments cFP-RTD-122 - page 8

    FP-RTD-122 and cFP-RTD-122 8 ni.com The [c]FP-R TD-122 uses a l inearizati on curve known as the Callendar-V an Dusen equat ion to measur e the temperature of R TDs. The equat ion is as follows: T emper atures belo w 0 ° C: R T = R 0 [1 + A × T + B × T 2 + C × T 3 × ( T – 100 °C )] T emper atur es a bo v e 0 ° C: R T = R 0 [1 + A × T + B ...

  • National Instruments cFP-RTD-122 - page 9

    © National Instruments Corp. 9 FP-RTD-122 and cFP-RTD-122 ef fects of th e lea ds. The only residua l error s ar e tho se ca us ed b y mismatchi ng the EX+ and COM lead s. Most R TDs have lead resistances wi thin 5% of each ot her, so the com pensation of the [c]FP-R TD-122 corrects for 95% or more of the errors introduced by lead resistanc es. Th ...

  • National Instruments cFP-RTD-122 - page 10

    FP-RTD-122 and cFP-RTD-122 10 ni.com Upgradin g the FieldPoi nt Firmw are Y ou may need t o upgra de the Fiel dPoin t firmware when y ou add new I/O module s to the Fi eldPo int syst em. For inf ormat ion on deter mining which f irmwar e you need an d ho w to upgr ade you r firmware, go to ni.com/info and enter fpmatrix . Isolation and Sa fety Guid ...

  • National Instruments cFP-RTD-122 - page 11

    © National Instruments Corp. 11 FP-RTD-122 and cFP-RTD-122 • Oper ate the [c]FP -R TD-122 only at or belo w Pollution Degree 2. Po llut ion Degree 2 mea ns tha t only no ncon ductive pollu tion oc curs in most case s. Occasion ally , howe ver , a tempor ary cond uctivity caused by con densati on must be expected. • Refer to t he Fiel dPoint pr ...

  • National Instruments cFP-RTD-122 - page 12

    FP-RTD-122 and cFP-RTD-122 12 ni.com Offset error , 4,00 0 Ω range 15 to 35 °C ......... ............... ... 0.2 Ω ty p, 0. 7 Ω ma x – 40 to 70 °C .............. ........... 0.8 Ω typ, 4.0 Ω ma x Gain error 15 to 35 °C ............. ........... ... 0.01% ty p, 0. 02% max – 40 to 70 °C ........... ........... ... 0.07% typ, 0. 1% m ...

  • National Instruments cFP-RTD-122 - page 13

    © National Instruments Corp. 13 FP-RTD-122 and cFP-RTD-122 Maximum altitud e ........... ........... ....... 2,000 m; a t higher a ltitude s the isolat ion v oltage r atings must be lowered Pollutio n De gree ......... ....... ........... ... 2 Shock an d Vibratio n Thes e speci fic ations apply on ly to the cFP -R TD- 122. NI recommends Compact F ...

  • National Instruments cFP-RTD-122 - page 14

    FP-RTD-122 and cFP-RTD-122 14 ni.com CE Complia nce This produ ct meets the essential re quirements of applicab le European Direct iv es, as amended for CE Mark ing, as follows: Lo w-V oltage Dire cti ve (safety)......... 73/23 /EEC Electrom agnetic Compati bility Directi ve (EMC ) ............. ....... ........... 89/33 6/EEC Note Ref er to t he D ...

  • National Instruments cFP-RTD-122 - page 15

    © National Instruments Corp. 15 FP-RTD-122 and cFP-RTD-122 Go to ni.com/support for the most current m anuals, example s, and t rouble shootin g info rmati on. For telephone supp ort in the United States, crea te your service request at ni.com/ask and follow the calling instructions or dial 512 795 8248. F or telep hone support outside the United ...

Manufacturer National Instruments Category Network Router

Documents that we receive from a manufacturer of a National Instruments cFP-RTD-122 can be divided into several groups. They are, among others:
- National Instruments technical drawings
- cFP-RTD-122 manuals
- National Instruments product data sheets
- information booklets
- or energy labels National Instruments cFP-RTD-122
All of them are important, but the most important information from the point of view of use of the device are in the user manual National Instruments cFP-RTD-122.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals National Instruments cFP-RTD-122, service manual, brief instructions and user manuals National Instruments cFP-RTD-122. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product National Instruments cFP-RTD-122.

A complete manual for the device National Instruments cFP-RTD-122, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use National Instruments cFP-RTD-122 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of National Instruments cFP-RTD-122.

A complete National Instruments manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual National Instruments cFP-RTD-122 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the National Instruments cFP-RTD-122, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the National Instruments cFP-RTD-122, that we can find in the current document
3. Tips how to use the basic functions of the device National Instruments cFP-RTD-122 - which should help us in our first steps of using National Instruments cFP-RTD-122
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with National Instruments cFP-RTD-122
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of National Instruments cFP-RTD-122 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning National Instruments cFP-RTD-122?

Use the form below

If you did not solve your problem by using a manual National Instruments cFP-RTD-122, ask a question using the form below. If a user had a similar problem with National Instruments cFP-RTD-122 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)