  • Fluke 7000DP - page 1

    Manual Supplement © 2008-2009 Fluke Corporation . All rights reserv ed. Printed in the U.S .A. Manual Title: Impulse 6000D/7000DP Users Supplement Issue: 3 Print Date: August 2007 Issue Date: 3/09 Revision/Date: 1, 1/08 Page Count: 10 This supplement contai ns information nece ssary to en sure the accuracy of the above manual. This manual is distr ...

  • Fluke 7000DP - page 2

    Impulse 6000D/7000DP Users Manual Supplement 4/08 1 Change #1, 46470, 46697, 47714, 48007, 49680 Replace pages 31 through 35, with the following: Defibrillator Analyzer Specifications Energy Output Measurement Compatible Defibrillator Wa veshapes ................ Lown, Edmark, Trapezoidal, DC Bi -phasic, and AC Pulsed Bi-phasic Note AC Pulsed Bipha ...

  • Fluke 7000DP - page 3

    Manual Supplement Impulse 6000D/700 0DP Users 2 8/08 Accuracy ............................................................. ± 0.1 ms Voltage Range ................................................................. 20 to 5000 V Accuracy ............................................................. ± (1 % of reading + 2 V) Current Range ............ ...

  • Fluke 7000DP - page 4

    Impulse 6000D/7000DP Users Manual Supplement 4/08 3 Scope Output Autorange ........................................................... 2000:1, 400:1 and 80:1: depe ndant on the range Waveform Playback Output ............................................................. BNC Output impedance........................................... 50 Ω Amplitude ...

  • Fluke 7000DP - page 5

    Manual Supplement Impulse 6000D/700 0DP Users 4 3/09 Ventricular Fibrillation ......................................... Coarse and fine Monomorphic Ventricular Tachycardia ............... 120 to 300 (by 5) BPM Polymorphic Ventricular Tachycardia ................. 5 types Asystole .............................................................. Flat l ...

  • Fluke 7000DP - page 6

    Impulse 6000D/7000DP Users Manual Supplement 8/08 5 Normal Sinus waves Lead # I II III V1 V2 V3 V4 V5 V6 Ref. Amp. 70 % 100 % 30 % 24 % 48 % 100 % 120 % 112 % 80 % Lead I reference Performance waves and R wave detection Lead # I II III V1 V2 V3 V4 V5 V6 Ref. Amp. 100 % 150 % 50 % 100 % 100 % 100 % 100 % 100 % 100 % Normal Sinus waves Lead # I II II ...

  • Fluke 7000DP - page 7

    Manual Supplement Impulse 6000D/700 0DP Users 6 4/08 Sine waves ......................................................... 0.05, 0.5, 5, 10, 40, 50, 60, 10 0, 150, and 200 Hz Pulse ................................................................... 30 and 60 BPM, 60 ms pulse width R-Wave Detection Waveform ........................................... ...

  • Fluke 7000DP - page 8

    Impulse 6000D/7000DP Users Manual Supplement 4/08 7 Accuracy ......................................................... ±(10 % of setting + 0.2 mV) Amplitude of Transvenous Pacer Pulse Simulation signals relative to amplitude setting (in percent) Lead II reference Lead # I II III V1 V2 V3 V4 V5 V6 Ref. Amp. 67 % 100 % 33 % 67 % 67 % 67 % 67 % 67 % ...

  • Fluke 7000DP - page 9

    Manual Supplement Impulse 6000D/700 0DP Users 8 4/08 Change #2 On page 12, prior to Analyzing Pacemakers (7000DP only) , add the following section: SCOPE OUTPUT Each time a defibrillator is fired into the An alyzer during an active defibrillator test, a delayed represe ntation of the defibrillator pulse is sent to the Scope Output jack on the rear ...

  • Fluke 7000DP - page 10

    Impulse 6000D/7000DP Users Manual Supplement 4/08 9 Pulse playback +4 V, 1 ms pulse Start of defibrillator pulse playback [1] [1] Pulse playback includes 0.4 ms before th e pulse was detected and theref ore displays any ear ly transitional signals. Use the synchronizing marker pulses to display specific information from the Scope Outpu t signal. To ...

  • Fluke 7000DP - page 11

    Manual Supplement Impulse 6000D/700 0DP Users 10 8/08 Change #3, 48038 On page 38, under Pacemaker Input, change: From: Accuracy …………..±1 % non-inductive (<2 μ H) To: Accuracy……………±2 % non-inductive (<2 μ H) ...

Manufacturer Fluke Category CD Player

Documents that we receive from a manufacturer of a Fluke 7000DP can be divided into several groups. They are, among others:
- Fluke technical drawings
- 7000DP manuals
- Fluke product data sheets
- information booklets
- or energy labels Fluke 7000DP
All of them are important, but the most important information from the point of view of use of the device are in the user manual Fluke 7000DP.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Fluke 7000DP, service manual, brief instructions and user manuals Fluke 7000DP. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Fluke 7000DP.

Similar manuals

A complete manual for the device Fluke 7000DP, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Fluke 7000DP by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Fluke 7000DP.

A complete Fluke manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Fluke 7000DP - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Fluke 7000DP, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Fluke 7000DP, that we can find in the current document
3. Tips how to use the basic functions of the device Fluke 7000DP - which should help us in our first steps of using Fluke 7000DP
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Fluke 7000DP
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Fluke 7000DP in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Fluke 7000DP?

Use the form below

If you did not solve your problem by using a manual Fluke 7000DP, ask a question using the form below. If a user had a similar problem with Fluke 7000DP it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)