  • Xantrex Technology TM500A - page 1

    Installation & Operator ’ s Guide TM500A Battery S t atus Monitor ™ ...

  • Xantrex Technology TM500A - page 2

    © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 About Xantrex Xantrex T echnology Inc., is a world-leading supplier of advanced power electronics and controls with products from 50 watt portables to 1 megawatt utility-scale systems for wind, solar , batteries, fuel cells, microturbines, and backup power applications in both grid-c ...

  • Xantrex Technology TM500A - page 3

    © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 i T able of Content s 1.0 INTRODUCTION ............................................................... 1 The TM500A .......................................................................................... 1 Unpacking and Inspection .................................................. ...

  • Xantrex Technology TM500A - page 4

    © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 ii T able of Content s (continued) 4.0 OPERA TION ................................................................... 2 5 Indicators and Controls ....................................................................... 2 5 Buttons ...................................................... ...

  • Xantrex Technology TM500A - page 5

    © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 IMPORT ANT SAFETY INSTRUCTIONS This manual contains important safety instructions that should be followed during the installation and maintenance of this product. T o reduce the risk of electrical shock, and to ensure the safe installation and operation of this product, the following ...

  • Xantrex Technology TM500A - page 6

    © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 BA TTER Y SAFETY INFORMA TION • Always wear eye protection, such as safety glasses, when working with batteries. • Remove all loose jewelry before working with batteries. • Never work alone. Have someone assist you with the installation or be close enough to come to your aid wh ...

  • Xantrex Technology TM500A - page 7

    1 © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 The TM500A The TM500A features six data monitoring functions and three indicators including: • S tate of charge/amp-hour content (full or percent of capacity) • S tate of charge/voltage (real-time volt age level, historical high and low system voltage) • Amps (real-time amps, ...

  • Xantrex Technology TM500A - page 8

    2 © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 Unpacking and Inspection Upon receiving the TM500A, check that the following items are included. TM500A (12/24 V olt) • TM500A (meter panel, adaptor and mounting bracket) • Manual • 50-foot communications cable • Deltec™ 500 amp/50 mV shunt • 12/24 volt shunt-printed ci ...

  • Xantrex Technology TM500A - page 9

    3 © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 Required T ools • Phillips screw driver • 3/32" and 3/16" drill bits • Hole saw If the TM500A will also function as a remote control (INVERTER ON/OFF), an additional cable must be ordered. Available lengths are: 10 feet–TC/10 25 feet–TC/25 50 feet–TC/50 100 fe ...

  • Xantrex Technology TM500A - page 10

    4 © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 Surface Mounting • Using the mounting bracket as a template, mark the positions for the screw holes and an area where the cable(s) will feed through. • Drill out the four screws holes (if required) and wire access opening. Use a 3/16" bit if the supplied plastic anchors ar ...

  • Xantrex Technology TM500A - page 11

    5 © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 Figure 2-2 Surface Mounting the TM500A Using the Adaptor Wire Access Hole T race Meter Bracket Trace Meter Adaptor T race Meter Figure 2-3 Communication and Remote Cable Connections J2 TO INVERTER ONL Y J1 TO SHUNT ONL Y SP ADE LUG 2.0 INST ALLA TION ...

  • Xantrex Technology TM500A - page 12

    6 © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 Flush Mounting T o flush mount the TM500A , an opening must be cut in the backing material to allow room for the circuit board, wires and connectors. Allow at least one inch depth behind the circuit board for the connectors and wires. • Use the bracket as a template and mark the ...

  • Xantrex Technology TM500A - page 13

    7 © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 Figure 2-4 Flush Mounting the TM500A Area T o Be Cut-Out T race Meter Bracket Trace Meter Figure 2-5 Communication and Remote Cable Connections J2 TO INVERTER ONL Y J1 TO SHUNT ONL Y SP ADE LUG 2.0 INST ALLA TION ...

  • Xantrex Technology TM500A - page 14

    8 © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 Extended Length Installations If the TM500A is mounted in excess of 100 feet from the inverter , an additional wire (with a spade lugs on both ends) must be connected between the TM500A and shunt spade lugs. This wire acts as a ground reference and ensures the meter will read accur ...

  • Xantrex Technology TM500A - page 15

    9 © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 Deltec™ Shunt W ARNING: BEFORE WIRING THE SHUNT TO THE BA TTERIES, SWITCH THE DC DISCONNECT TO OFF AND/OR REMOVE THE DC FUSE. Mounting/Wiring the Shunt The shunt connects between the inverter and batteries in the negative (–) line (Figure 2-10). • Mount the shunt on or near t ...

  • Xantrex Technology TM500A - page 16

    10 © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 Mounting Circuit Board to an Existing Shunt Model TM500A - NS is supplied without a shunt and is intended to be wired to an existing shunt. The kit includes two brass 8-32 x 5/8 inch machine screws, two lock-washers and two metal standoffs. NOTE: The shunt must be of the proper ty ...

  • Xantrex Technology TM500A - page 17

    11 © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 Connecting the Shunt Board • Remove the fuse from the in-line fuse holder by rotating the fuse holder cap counterclockwise. • Connect the ring terminal from the fuse holder to the battery’s positive terminal. • Connect the shunt communications cable into the RJ1 1 jack on ...

  • Xantrex Technology TM500A - page 18

    12 © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 Setup The TM500A is configured at the factory for monitoring a 12 VDC system. These settings can be changed to meet specific system parameters. The default settings are: % Charge Efficiency 94 % V V oltage (full-charge) 14.4 volts DC A Amperage DC 35 amps Ah Amp Hours 200 Hours Lo ...

  • Xantrex Technology TM500A - page 19

    © 2001 Xantrex T echnology Inc. 13 P/N 973-0012-01-02 Rev . A 05/01 Setting Parameters Individual system parameters can be set by the following procedure: 1. Press the SELECT button until the mode selection indicator to be set is illuminated. 2. Press the SELECT and RESET buttons simulat aniously . Release both buttons when the LED display flashes ...

  • Xantrex Technology TM500A - page 20

    14 © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 Setting Parameters (continued) Charge Efficiency % Since batteries are not 100 percent efficient, more energy is required to charge them than can be extracted. Some of this energy is lost in the form of heat and gassing. An efficiency factor of 94 to 98% is typical for lead-acid b ...

  • Xantrex Technology TM500A - page 21

    © 2001 Xantrex T echnology Inc. 15 P/N 973-0012-01-02 Rev . A 05/01 Setting Parameters (continued) Amp Hours Ah The amp-hour setting should be set to a value equal or lower than the actual amp-hour capacity of the system’s battery bank. Using a number that is lower than the actual amp-hour capacity allows the % Battery S tate-of- Charge meter to ...

  • Xantrex Technology TM500A - page 22

    16 © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 Figure 3-4 Setting the Amp Hours Setting Parameters (continued) 4 280. Set Battery Amp-Hour Rating 2 3 1 Ah LED Indicates Amp-Hour Function is Selected 3.0 CONFIGURA TION ...

  • Xantrex Technology TM500A - page 23

    © 2001 Xantrex T echnology Inc. 17 P/N 973-0012-01-02 Rev . A 05/01 Setting Parameters (continued) CHARGED Indicator Setup The CHARGED indicator LED can be programmed to light when the batteries are fully charged based on several different parameters: • Trigger the LED when voltage only parameters are met • Trigger the LED when voltage and cur ...

  • Xantrex Technology TM500A - page 24

    18 © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 Setting Parameters (continued) CHARGED Indicator Setup (continued) The fully-charged voltage parameters are now set. T o allow the voltage only setting to trigger the fully-charged LED, the amperage setting must be switched OFF . Step B Switching OFF the Amperage Detection 1B. Pre ...

  • Xantrex Technology TM500A - page 25

    © 2001 Xantrex T echnology Inc. 19 P/N 973-0012-01-02 Rev . A 05/01 Setting Parameters (continued) CHARGED Indicator Setup (continued) T rigger on Voltage and Amperage When this mode is selected, the CHARGED indicator LED illuminates when the volt age reaches the programmed level (Step A) and the amperage decreases to the value set in S tep B. As ...

  • Xantrex Technology TM500A - page 26

    20 © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 Step B Setting the Amperage Trigger Level 1B. Press the SELECT button until the Amperage LED ( A ) is illuminated. 2B. Press the SELECT and RESET buttons simulataniously until the LED display flashes. 3B. Press the RESET button until the display indicates the desired amperage. 4B. ...

  • Xantrex Technology TM500A - page 27

    © 2001 Xantrex T echnology Inc. 21 P/N 973-0012-01-02 Rev . A 05/01 Setting Parameters (continued) CHARGED Indicator Setup (continued) T rigger on V oltage and Time When this mode is selected, the CHARGED indicator LED illuminates when the volt age reaches the programmed level (Step A) and the amperage remains positive for the specified time (S te ...

  • Xantrex Technology TM500A - page 28

    22 © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 Setting Parameters (continued) CHARGED Indicator Setup (continued) Step B Setting the Time Duration 1B. Press the SELECT button until the Amperage LED ( A ) is illuminated. 2B. Press the SELECT and RESET buttons simulataniously until the LED display flashes. 3B. Press the RESET bu ...

  • Xantrex Technology TM500A - page 29

    © 2001 Xantrex T echnology Inc. 23 P/N 973-0012-01-02 Rev . A 05/01 Setting Parameters (continued) CHARGED Indicator Setup (continued) Charger Considerations There are several different types of chargers (relay , taper or three- stage) which can affect the settings and prevent the CHARGE LED from illuminating. Relay Chargers Relay type chargers ra ...

  • Xantrex Technology TM500A - page 30

    24 © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 Setting Parameters (continued) Low-V oltage Indicator V The TM500A should be set to trigger on a user specified low DC voltage level. When the battery voltage falls below this level, the VOL T AGE indicator ( V ) flashes approximately once every four seconds. This meter is useful ...

  • Xantrex Technology TM500A - page 31

    © 2001 Xantrex T echnology Inc. 25 P/N 973-0012-01-02 Rev . A 05/01 Indicators and Controls The TM500A contains the following controls and indicators. • Large three-digit LED display • Four red mode indicators • One green CHARGED indicator • One green INVERTER ON/OFF indicator • Three pressure sensitive push-buttons The three-digit LED d ...

  • Xantrex Technology TM500A - page 32

    26 © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 Indicators and Controls (continued) Basic Meters T o display one of the four meters; • Press the SELECT button until the desired indicator illuminates. • The LED display indicates the values for the selected function. A vailable Meters % (st ate-of charge) When this indicator ...

  • Xantrex Technology TM500A - page 33

    © 2001 Xantrex T echnology Inc. 27 P/N 973-0012-01-02 Rev . A 05/01 Indicators and Controls (continued) Ah (AMP HOURS) When this indicator is illuminated, the LED display shows the total amp hours used since the last time the amp-hour meter was reset. The range is from ±0.00 to ±167,000 amp hours. When the decimal point flashes, multiply the rea ...

  • Xantrex Technology TM500A - page 34

    28 © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 Indicators and Controls (continued) Dat a Monitors There are several additional data displays available, accessed by pressing and holding the SELECT button until “dSF” appears in the display . Pressing and releasing the SELECT button alternates between it s value, then scrolls ...

  • Xantrex Technology TM500A - page 35

    © 2001 Xantrex T echnology Inc. 29 P/N 973-0012-01-02 Rev . A 05/01 Indicators and Controls (continued) T o access the Dat a Monitor Function: • Press and hold the SELECT button until dSF appears in the LED display . The display alternates between the data monitor function and it s data. • Press the RESET button to display the value for the se ...

  • Xantrex Technology TM500A - page 36

    30 © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 Reminders and Indicators The TM500A features a programmable recharge reminder as well as low- voltage and charged indicators. Amp-Hour Reminder The Amp-Hour LED can be configured to flash at a specified interval following recharge as a reminder that it is time to charge the batter ...

  • Xantrex Technology TM500A - page 37

    © 2001 Xantrex T echnology Inc. 31 P/N 973-0012-01-02 Rev . A 05/01 Reminders and Indicators (continued) Low-V oltage Indicator A voltage between 10 and 35 volts (10 and 64.9 volt s for 48-volt systems) can be specified to activate the low-voltage alarm. When the battery voltage falls below this level, the voltage indicator ( V ) flashes approxima ...

  • Xantrex Technology TM500A - page 38

    32 © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 Reminders and Indicators (continued) CHARGED Indicator The CHARGED indicator ( ) can be programmed to flash every four seconds when specified charging criteria are met. This can be voltage only , voltage and current , or volt age and time . When the programmed conditions are met f ...

  • Xantrex Technology TM500A - page 39

    © 2001 Xantrex T echnology Inc. 33 P/N 973-0012-01-02 Rev . A 05/01 m o t p m y S e s u a C e l b i s s o P n o i t u l o S F F O / N O R E T R E V N I n i D E L . t h g i l t o n s e o d h c t i w s o t n i d e g g u l p t o n g u l p 2 J . r e t r e v n i e h t r o A 0 0 5 M T a e v a h t o n s e o d r e t r e v n I . k c a J e l b a t a p m o c ...

  • Xantrex Technology TM500A - page 40

    34 © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 Xantrex T echnology Inc., takes great pride in its products and makes every effort to ensure your unit fully meets your independent powering needs. If your product needs repair , contact our Customer Service department at: (360) 435-8826 to obtain an RMA# and shipping information; ...

  • Xantrex Technology TM500A - page 41

    ©2001 Xantrex T echnology Inc. 35 P/N 973-0012-01-02 Rev . A 05/01 Specifications Function Range Accuracy Battery V olts 8.0–35 volts ± 0.1 volt 16.0–70 volts ± 0.2 volt Battery Amps 0.1–999 amps ± 1.5% (+ least significant digit) Battery Amp s Resolution 0.1 to 99.9 amps ± 0.1 amp 100 to 999 amps ± 1.0 amp Battery Level % Low (< 27. ...

  • Xantrex Technology TM500A - page 42

    36 © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 Limited Warranty Xantrex T echnology Inc., warrants its power products against defects in materials and workmanship for a period of two (2) years from the date of purchase, established by proof of purchase or formal warranty registration, and extends this warranty to all purchaser ...

  • Xantrex Technology TM500A - page 43

    ...

  • Xantrex Technology TM500A - page 44

    Xantrex T echnology Inc. 5916 195th Northeast Arlington, WA 98223 U.S.A. t: 360/435.8826 f: 360/435.3945 ww w .xantrex.com Printed in U.S.A. © 2001 Xantrex T echnology Inc. P/N 973-0012-01-02 Rev . A 05/01 ...

Manufacturer Xantrex Technology Category Computer Monitor

Documents that we receive from a manufacturer of a Xantrex Technology TM500A can be divided into several groups. They are, among others:
- Xantrex Technology technical drawings
- TM500A manuals
- Xantrex Technology product data sheets
- information booklets
- or energy labels Xantrex Technology TM500A
All of them are important, but the most important information from the point of view of use of the device are in the user manual Xantrex Technology TM500A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Xantrex Technology TM500A, service manual, brief instructions and user manuals Xantrex Technology TM500A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Xantrex Technology TM500A.

A complete manual for the device Xantrex Technology TM500A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Xantrex Technology TM500A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Xantrex Technology TM500A.

A complete Xantrex Technology manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Xantrex Technology TM500A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Xantrex Technology TM500A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Xantrex Technology TM500A, that we can find in the current document
3. Tips how to use the basic functions of the device Xantrex Technology TM500A - which should help us in our first steps of using Xantrex Technology TM500A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Xantrex Technology TM500A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Xantrex Technology TM500A in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Xantrex Technology TM500A?

Use the form below

If you did not solve your problem by using a manual Xantrex Technology TM500A, ask a question using the form below. If a user had a similar problem with Xantrex Technology TM500A it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)