  • Sanyo ECOi - page 1

    ECOi TM V ariable R efrigerant Flo w (VRF), Multi-Zone, Heat P ump & Heat R eco v er y S y stems ...

  • Sanyo ECOi - page 2

    INTRODUCTION.. ..................................................2 ECOi™ Building Y our Business..................................3 ECOi™ . Y our Building Life T ool ..................................4 SANY O OUTDOOR Units ..................................6 3 Pipe VRF Heat Recovery ................................6 ECOi Mini VRF .............. ...

  • Sanyo ECOi - page 3

    INTRODUCTION E CO i™ . B u i l d i ng Y o u r B u s i n e s s . SANY O's Brand V ision SANYO HV AC consistently builds new ideas to help build your business. By delivering multi-zone options, space-saving and environmentally friendly designs, our solutions are evolving, improving solutions. Flexible Combinations: ECOi allows multiple indoor ...

  • Sanyo ECOi - page 4

    Contractors. Buil ding Support. At SANYO, we realize contractors are looking for turnkey installation and support. ECOi™ is quite simply the perfect building solution. With its modular design and ease of installation, it’ s a solution that can grow with any building project. In fact, ECOi may just make you remember why you got into the business ...

  • Sanyo ECOi - page 5

    INTRODUCTION For th e b ui ldi ngs re qui ri ng sim ult ane ou s h eat ing an d coo lin g, SANYO 3-Way ECOi™ system provides the perfect solution 05 05 C o m m e r ci a l o f f i c e b u i l d i n g s a r e s u b j e c t t o f l uc t ua t i n g h e a t l e v e l s g e n e r a t e d f r o m e l e c t r on ic o f f i c e e q u i p m e n t , ligh t ...

  • Sanyo ECOi - page 6

    MODELS (T ype: Nominal Cooling Capacity , etc) V olt PH CHDZ 07263 72,000 BTU Heat Recovery 208-230V/60 HZ 3 CHDZ R07263 72,000 BTU Heat Recovery W ith Salt Protection - Special Order 208-230V/60 HZ 3 CHDZ 09663 96,000 BTU Heat Recovery 208-230V/60 HZ 3 CHDZ R09663 96,000 BTU Heat Recovery W ith Salt Protection - Special Order 208-230V/60 HZ 3 CHDZ ...

  • Sanyo ECOi - page 7

    SANY O OUTDOOR 07 DESCRIPTION CHDZ (R) 07263 CHDZ (R) 09663 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW 72,000 5.3 81,000 5.79 96,000 7.75 108,000 8.6 ELECTRICAL RA TINGS VOL T AG E R A TING COOLING RUNNING AMPERES HEA TING RUNNING AMPERES MIN. CIRCUIT AMP ACITY MAX. CIRCUIT AMP ACITY 208 - 230 ...

  • Sanyo ECOi - page 8

    WCHDZ 14463 / WCHDZ 16863 / WCHDZ 19263 WCHDZ 21663 / WCHDZ 24063 WCHDZ 26463 / WCHDZ 28863 K E Y F E AT U R E S : * T hre e -Way H ea t Re c ov er y * Co mbin e 3 ou td oor u nit s up t o 24 tons * “EC O F rie ndl y” R 41 0A R ef r iger an t * 20 8/ 23 0 V , 3 Ph ase, 6 0 H z * Mult iple C omp r es so rs F o r E x tr a Reliabilit y and P ar ti ...

  • Sanyo ECOi - page 9

    SANY O OUTDOOR 09 WCHDZ SERIES 3-W ay ECOi VRF Heat Recov ery Combined Units DESCRIPTION WCHDZ 14463 WCHDZ 16863 WCHDZ 19263 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW includes (1) CHDZ07263 and (1) CHDZ07263 144,000 10.56 162,000 11.58 includes (1)CHDZ07263 and (1) CHDZ09663 168,000 12.97 189, ...

  • Sanyo ECOi - page 10

    WCHDZ SERIES 3-W ay ECOi VRF Heat Recov ery combined units DESCRIPTION WCHDZ 21663 WCHDZ 24063 WCHDZ 26463 WCHDZ 28863 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW includes (3) CHDZ07263 216,000 15.84 243,000 17.37 includes (2) CHDZ07263 and (1) CHDZ09663 240,000 18.25 270,000 20.18 includes (1) ...

  • Sanyo ECOi - page 11

    11 SANYO’ s Mini ECOi is suited for numerous commercial and premium residential applications. SANY O OUTDOOR CHX SERIES Mini ECOi Multi Split VRF Heat Pump CHX (R) 03652 / CHX (R) 05252 K E Y F E AT U RE S : * Single P ha se 2 0 8 / 2 3 0 v olt s * One O u tdo or U nit C on ne c ts A s M an y A s 9 Ind oor U nit s ( 5 0 % -1 30 % r at io of ind o ...

  • Sanyo ECOi - page 12

    12 CHDX SERIES 2-W ay ECOi VRF Heat Pump DESCRIPTION (T ype: Nominal Cooling Capacity , etc) V olt PH CHDX 07263 * 72,000 BTU Heat Pump 208-230V/60 HZ 3 CHDX (R) 07263 * 72,000 BTU Heat Pump W ith Salt Protection - Special Order 208-230V/60 HZ 3 CHDX 09663 * 96,000 BTU Heat Pump 208-230V/60 HZ 3 CHDX (R) 09663 * 96,000 BTU Heat Pump W ith Salt Prot ...

  • Sanyo ECOi - page 13

    13 SANY O OUTDOOR CHDX SERIES 2- W ay ECOi VRF Heat Pump * NOTE : *460 V olt Step Down T ransformers (460-230) available for 6 and 8 ton condensers (R) indicates with salt protection - Special Order DESCRIPTION CHDX (R) 07263 CHDX (R) 09663 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW 72,000 5.28 ...

  • Sanyo ECOi - page 14

    14 WCHDX SERIES W 2-W ay ECOi VRF Heat Pumps combined units WCHDX 14463 / WCHDX 16863 / WCHDX 19263 WCHDX 21663 / WCHDX 24063 WCHDX 26463 / WCHDX 28863 K E Y F E AT U RE S : * He at P um p * Co mbin e 3 ou td oor u nit s up t o 24 tons * Co mbin ed S er ies A llow s Up t o 4 0 In doo r Uni ts ( 5 0 % - 1 30 % ra tio of indo or t o ou td oor c ap a ...

  • Sanyo ECOi - page 15

    15 SANY O OUTDOOR WCHDX SERIES W 2-W ay ECOi VRF Heat Pumps combined units DESCRIPTION WCHDX 14463 WCHDX 16863 WCHDX 19263 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW includes (2) CHDX07263 144,000 10.56 162,000 11.58 includes (1) CHDX07263 and (1) CHDX09663 168,000 12.97 189,000 14.39 includes ...

  • Sanyo ECOi - page 16

    16 WCHDX SERIES W 2-W ay ECOi VRF Heat Pumps combined units DESCRIPTION WCHDX 21663 WCHDX 24063 WCHDX 26463 WCHDX 28863 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW includes (3) CHDX07263 216,000 15.84 243,000 17.37 includes (2) CDDX07263 and (1) CHDX09663 240,000 18.25 270,000 20.18 includes (1) ...

  • Sanyo ECOi - page 17

    17 SANY O INDOOR KHX 0752 / KHX 0952 / KHX 1252 / KHX 1862 KHX 1962 / KHX 2452 / A TK-SVRK56BA K E Y F E AT U RE S : * “EC O F rie ndl y” R 41 0A R ef r iger an t * 20 8/ 23 0 V , 1 Ph ase, 6 0 H z * Ea sy Wall Mo un t for A n y A p plica tio n * W a s h a b l e L o n g L if e F i l t e r * E l e c t r on i c E x p a n s i o n V al v e ( E E V ...

  • Sanyo ECOi - page 18

    18 THX SERIES Ceiling Suspended Unit DESCRIPTION THX 1252 THX 1852 THX 2452 CAP ACIT Y COOLING HEA TING 12,000 BTU 14,000 BTU 19,000 BTU 21,000 BTU 25,000 BTU 27,000 BTU CUR REN T COOLING HEA TING 0.14/0.17 A 0.14/0.15 A 0.15/0.14 A 0.15/0.17 A 0.34/0.31 A 0.34/0.36 A POW ER INP UT COOLING HEA TING 15/16 W 15/16 W 16/16 W 16/18 W 38/37 W 40/40 W UN ...

  • Sanyo ECOi - page 19

    SYSTEM/MODEL Components (T ype: Nominal Cooling Capacity , etc) V olt PH 07 AHX 52 System 7500 BTU 1-Way Ceiling cassette (includes grille) 208-230V/60 HZ 1 AHX 0752 cassette 208-230V/60 HZ 1 PNR-AH1252 grille 09 AHX 52 System 9000 BTU 1-Way Ceiling cassette (includes grille) 208-230V/60 HZ 1 AHX 0952 cassette 208-230V/60 HZ 1 PNR-AH1252 grille 12 ...

  • Sanyo ECOi - page 20

    XMHX SERIES Concealed Ducted - Low Profile, Low Static, with Condensate Pump 4-W ay Ceiling Cassette 24" x 24", with Condensate Pump 12 XMHX 52 / 18 XMHX 52 K E Y F E AT U RE S : * “EC O F rie ndl y” R 41 0A R ef r iger an t * 20 8/ 23 0 V , 1 Ph ase, 6 0 H z * F o u r Wa y A i r T h r o w * Wash able L on g Li fe A ir F ilter * B ui ...

  • Sanyo ECOi - page 21

    SANY O INDOOR XHX SERIES 4-W ay Ceiling Cassette 35" x 35", with Condensate Pump 24 XHX 52 / 36 XHX 52 K E Y F E AT U RE S : * “EC O F rie ndl y” R 41 0A R ef r iger an t * 20 8/ 23 0 V , 1 Ph ase, 6 0 H z * F o u r Wa y A i r T h r o w * Wash able L on g Li fe A ir F ilter * B ui l t- In D r a i n P um p – 2 5 I n c h L i f t Po ss ...

  • Sanyo ECOi - page 22

    UMHX SERIES Concealed Ducted - Low Profile, Low Static, with Condensate Pump UMHX 0762 / UMHX 0962 / UMHX 1262 UMHX 1562 / UMHX 1862 K E Y F E AT U RE S : * “E C O Fr ie nd ly ” R 410A R e f ri ge ra n t * 20 8 / 2 3 0 V, 1 Pha se , 6 0 Hz * Ele c t r oni c E x p a nsi on Va lv e ( E E V ) fo r A c cur a t e Re f ri ge ra n t C on t ro l * Ad ...

  • Sanyo ECOi - page 23

    SANY O INDOOR UHX SERIES Concealed Ducted - Medium Static DESCRIPTION UHX 0762 UHX 0962 UHX 1262 UHX 1562 UHX 1862 UHX 2462 UHX 3662 UHX 4862 UHX 5462 PERFORMANCE COOL ING CAP A CITY HEA TING CAP ACITY 7,500 BTU/H 8,500 BTU/H 9,600 BTU/H 11,000 BTU/H 12,000 BTU/H 14,000 BTU/H 15,0 0 0 BTU/H 17 , 0 0 0 BTU/H 19,0 0 0 BTU/H 21,0 0 0 BTU/H 25 ,0 0 0 B ...

  • Sanyo ECOi - page 24

    DHX SERIES Concealed Ducted - Medium-High Static DESCRIPTION DHX 3652 DHX 4852 CAP ACIT Y COOLING HEA TING 36,000 BTU 39,000 BTU 47,800 BTU 54,600 BTU CUR REN T COOLING HEA TING 2.84/2.89 A 2.74/2.80 A 3.24/3.19 A 3.17/3.42 A POW ER INP UT COOLING HEA TING 548/620 W 528/602 W 644/695 W 627/756 W UNIT DIMENSIONS Inches (") / lbs. 16.5"/ 42 ...

  • Sanyo ECOi - page 25

    SANY O INDOOR FHX/FMHX SERIES Floor Mounted FMHX 0762 / FMHX 0962 / FMHX 1262 FMHX 1562 / FMHX 1862 / FMHX 2462 K E Y F E AT U RE S : * “EC O F rie ndl y” R 41 0A R ef r iger an t * 20 8/ 23 0 V , 1 Ph ase, 6 0 H z * Ele ct r onic E xp an sion Valv e ( E E V ) fo r Ac cu ra te R ef r iger an t C on tr ol * Wir e d or W irel es s Rem ot e C on t ...

  • Sanyo ECOi - page 26

    CONTROL S Y S TEMS SANYO’ s system control network is the heart and soul of the ECOi™ unit, enabling it to live with the living inside. With a simple two-wire loop installation, we put co nt rol in yo ur ha nds , l ite ral ly . N o o uts id e spe cia lis ts re qui red , i t’ s a n all -in -on e s ol uti on for you, and a way to further build ...

  • Sanyo ECOi - page 27

    SANY O Control S ystem 27 CONTROL S Y S TEMS Simple System Control Network WIRED REMO TES SIMPLE TO INST ALL K E Y F E AT U RE S : ( S I M PL E RE M O T E ) * T hin and E as y T o Re ad * Simple T o Ins t all and Us e * Ca n Be A d ap te d fo r Us e On A ll EC Oi In doo r Unit s * Mo de * Operating Mode (Heating / Cooli ng/Au to / Dr y/ F an) * Vac ...

  • Sanyo ECOi - page 28

    CONTROL S Y S TEMS Simple System Control Network SHA-K T 2 5 6BA Intel l igent Controll er K E Y F E AT U RE S ( INT EL L IGENT CONT ROL) : * 6.5 Inc h T ouch Scr een P anel * Co ntr ols up to 2 5 6 Indo or unit s wi th ad ded C ommu nicat ion Ad apt er (1 28 indo ors w it hou t ) * N e w C o n t r ol W i r i n g S y s t e m ( S N e t ) C o n n e c ...

  • Sanyo ECOi - page 29

    SANY O Control S ystem 29 CONTROL S Y S TEMS Building Management Integration K E Y F E AT U RE S : * Co mmunica te W it h L onWork s Co mp atible Sy st ems * St ar t / St op * Co ntr ols Up T o 1 6 Groups ( Ma ximum 6 4 In door U nits ) * F o r 17 o r m or e g r o u p s o f in d o or u ni t s c on n e c t a d di t i o n a l inter fac e unit s. * T ...

  • Sanyo ECOi - page 30

    30 A CCESSORIES P ART NUMBER DESCRIPTION 2-W a y Distr ibution Kits (cut to fit) Simple System Control Network APR -P160UK DISTRIBUTION JOINT KIT CUT TO FIT Used with 2 Pipe indoor Unit Piping - Up to 76,400 BTUs APR -P680UK DISTRIBUTION JOINT KIT CUT TO FIT Used with 2 Pipe indoor Unit Piping - 76,500 to 232,000 BTUs APR -P1350UK DISTRIBUTION JOI ...

  • Sanyo ECOi - page 31

    31 SERVICES SER VICES Simple System Control Network P ART NUMBER DESCRIPTION ECO -SC-4 ECOi COMMISSIONING (Per normal business day , up to 24 tons) IC -SC-1 COMMISSIONING OF INTELLIGENT CONTROLLER (Base fee for each Intelligent Controller) IC -SC-INDOOR COMMISSIONING OF INTELLIGENT CONTROLLER (Indoor Units) LW -SC-1 COMMISSIONING OF LONWORKS INTERF ...

  • Sanyo ECOi - page 32

    Us age ○ T h e a i r c on d i t i o n e r s l i s t e d h e r e i n a r e o nl y f o r c o o l i n g / h e a t i n g a r e a s u s e d b y peo pl e. D o no t u se t h e un i t f or f oo ds , an ima ls , pla n t s, p r e ci si on m ac hi ne s, w o r k s o f a r t o r o t h e r o b j e c t s . D o i ng s o m a y c a u s e d a m a g e t o t h e u n ...

Manufacturer Sanyo Category Work Light

Documents that we receive from a manufacturer of a Sanyo ECOi can be divided into several groups. They are, among others:
- Sanyo technical drawings
- ECOi manuals
- Sanyo product data sheets
- information booklets
- or energy labels Sanyo ECOi
All of them are important, but the most important information from the point of view of use of the device are in the user manual Sanyo ECOi.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Sanyo ECOi, service manual, brief instructions and user manuals Sanyo ECOi. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Sanyo ECOi.

Similar manuals

A complete manual for the device Sanyo ECOi, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Sanyo ECOi by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Sanyo ECOi.

A complete Sanyo manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Sanyo ECOi - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Sanyo ECOi, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Sanyo ECOi, that we can find in the current document
3. Tips how to use the basic functions of the device Sanyo ECOi - which should help us in our first steps of using Sanyo ECOi
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Sanyo ECOi
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Sanyo ECOi in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Sanyo ECOi?

Use the form below

If you did not solve your problem by using a manual Sanyo ECOi, ask a question using the form below. If a user had a similar problem with Sanyo ECOi it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)