  • White Rodgers 1F95-391 - page 1

    WHITE-RODGERS 90 SERIES 1F95-391 MUL TI-ST AGE/HEA T PUMP INST ALLA TION/CONFIGURA TION This White-Rodgers Digital Thermostat uses microcomputer technology to provide precise time, humidity , and temperature control. This thermostat offers the flexibility to design 1F95-391 : 7 Day programming; residen- tial applications. ELECTRICAL D A T A Electri ...

  • White Rodgers 1F95-391 - page 2

    A TTENTION! This product does not contain mercury . However , this product may replace a unit which contains mercury . Do not open mercury cells. If a cell becomes damaged, do not touch any spilled mercury . W earing non-absorbent gloves, take up the spilled mercury with sand or other absorbent material and place into a container which can be seale ...

  • White Rodgers 1F95-391 - page 3

    HEA T PUMP TERMINAL OUTPUTS Refer to equipment manufacturers’ instruc- tions for specific system wiring information. Y ou can configure the thermostat for use with the following heat pump system types: HEA T PUMP TYPE 1. Single-stage compressor system; gas or electric backup. HEA T PUMP TYPE 2. Multi-stage or two- compressor system; gas or electr ...

  • White Rodgers 1F95-391 - page 4

    RESET SWITCH See the T roubleshooting section at the end of this document for more information about the function of this switch. E2/P SWITCH (DHM) TERMINAL FUNCTION The E2/P switch is located on the back of the thermostat body (see fig. 2). This switch controls how the DHM terminal will be energized. 1. In the P position (up) the DHM terminal will ...

  • White Rodgers 1F95-391 - page 5

    INST ALLER CONFIGURA TION BEFORE TURNING POWER ON, please read the following instructions. Befor e operating the system, you must configure the thermostat to operate properly with your equipment. The thermostat, as it comes from the factory , is configured to operate a standard multi- stage electric forced hot air system with a single stage air con ...

  • White Rodgers 1F95-391 - page 6

    INST ALLER T ABLE NOTE: You must be in the User Configuration Menu to enter the Installer Table. Firmly press TIME FWD and TIME BACK at same time and release to enter the Configuration Menu. 6 1 ML TI STG HEA T PUMP 2 HEA T PUMP (1) 2 Selects type of system. Selecting HEA T PUMP makes additional items for heat pump systems av ailable. 3 ELEC HEA T ...

  • White Rodgers 1F95-391 - page 7

    These numbers are approximate and represent operation with a typical system. Actual temperature differentials and run times may vary widely based on your building and equipment, as well as outdoor temperature conditions. COMPRESSOR OFF DELA Y Installer table, step 1 1 is available if the fossil fuel kit alternative option (PUMP OFF) is selected. Th ...

  • White Rodgers 1F95-391 - page 8

    The Service Button Menu allows you to view or program as many as 4 reminders that indicate when service is required. 1. Humidifiers = A programmable run time in hours to indicate on the LCD when the humidifier will need to be serviced. 2. Air Filters = A programmable run time in hours to indicate on the LCD when the filter will need to be serviced ...

  • White Rodgers 1F95-391 - page 9

    TR OUBLESHOO TING F AN OPERA TION If your system does not have a G terminal Connection, skip to HEA T/HUMIDITY section below . 1. Turn power on to the system. 2. Press PROGRAM RUN . 3. Press FA N until F AN ON is displayed. The fan should begin to operate. 4. Press FA N until F AN AUT O is displayed. The fan should stop operating, unless a call for ...

  • White Rodgers 1F95-391 - page 10

    Symptom P ossible Cause Corrective Action No Heat/No Cool/No Fan 1. Blown fuse or tripped circuit breaker . Replace fuse or reset breaker . (Common Prob lems) 2. Furnace power switch to OFF . T ur n switch to ON. 3. Furnace blow er compar tment door or Replace door panel in proper position to engage panel loose or not properly installed. saf ety in ...

  • White Rodgers 1F95-391 - page 11

    Symptom P ossible Cause Corrective Action Thermostat Setting and Thermostat 1. Thermostat ther mometer setting requires The thermometer can be adjusted +/- 5 degrees. Thermometer Disagree adjustment. See T emperature Displa y Adjustment in the Operating Manual under Configuration. Thermostat Display Sho ws CHCK P AD, 1. Thermostat ser vice indicato ...

  • White Rodgers 1F95-391 - page 12

    The Emerson logo is a trademark and a service mar k of Emerson Electric Co. ...

Manufacturer White Rodgers Category Heat Pump

Documents that we receive from a manufacturer of a White Rodgers 1F95-391 can be divided into several groups. They are, among others:
- White Rodgers technical drawings
- 1F95-391 manuals
- White Rodgers product data sheets
- information booklets
- or energy labels White Rodgers 1F95-391
All of them are important, but the most important information from the point of view of use of the device are in the user manual White Rodgers 1F95-391.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals White Rodgers 1F95-391, service manual, brief instructions and user manuals White Rodgers 1F95-391. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product White Rodgers 1F95-391.

A complete manual for the device White Rodgers 1F95-391, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use White Rodgers 1F95-391 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of White Rodgers 1F95-391.

A complete White Rodgers manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual White Rodgers 1F95-391 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the White Rodgers 1F95-391, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the White Rodgers 1F95-391, that we can find in the current document
3. Tips how to use the basic functions of the device White Rodgers 1F95-391 - which should help us in our first steps of using White Rodgers 1F95-391
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with White Rodgers 1F95-391
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of White Rodgers 1F95-391 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning White Rodgers 1F95-391?

Use the form below

If you did not solve your problem by using a manual White Rodgers 1F95-391, ask a question using the form below. If a user had a similar problem with White Rodgers 1F95-391 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)