  • Philips TW0200 - page 8

    7-1.5 Meters for M/W System 1. Power Meter Anritsu - ML 4803 A 2. Power Meter HP - 437 B, 4368, Philips 3350 3. Spectrum Analyzer- Anritsu MS 7101 B,10 KHz- 23 GHz, 22 GHz- 140 GHz. 4. M/W System Analyzer (MSA ) Transm itter & Receiver ME 538 M Anritsu 4510 B Transmitter and Receiver. 5. M/W frequenc y counter Anritsu MF 76 A 6. Sweep Generator ...

  • Philips TW0200 - page 9

    7-1.6 Before proceeding any M/W system A/T --------- 1] Get TT-O, TT-1 duly filled in all respect, 2] Collect Survey report which includes, - Check list - Route details - Site survey report - Particulars at a glance - Clearance calculation - Path data calculation - Rain attenuation calculation - Availability calculation - Interference calculation - ...

  • Philips TW0200 - page 10

    161 ...

  • Philips TW0200 - page 11

    162 ...

  • Philips TW0200 - page 12

    163 ...

  • Philips TW0200 - page 13

    164 ...

  • Philips TW0200 - page 14

    165 ...

  • Philips TW0200 - page 15

    166 ...

  • Philips TW0200 - page 16

    167 ...

  • Philips TW0200 - page 17

    168 ...

  • Philips TW0200 - page 18

    169 ...

  • Philips TW0200 - page 19

    170 ...

  • Philips TW0200 - page 20

    171 ...

  • Philips TW0200 - page 21

    172 ...

  • Philips TW0200 - page 22

    7-2 MICROWAVE SYSTEM A/T Microwave A/T comprises of - Local A/ T of all stations, and Repeaters. - Hop Test. - Through Test. 7-2.1 Local A/T:- There are several makes of Narrow / Wide band m icrowave systems, near about all test are same except power suppl y points, access points. Here for ex ample Satara M/W station to T.E. end link of 11 GHz (1+ ...

  • Philips TW0200 - page 23

    174 ...

  • Philips TW0200 - page 24

    3. Test on receiver :- - Check of RLO frequency :- Check of RLO frequency with unritsu or HP frequency counter, measure frequency and offset - Write assigned measured and deviation in PPM lim it ±20 PPM - Measure RLO output level at RLO mon limit ≥ -12 dBm - Feed Receive RF frequency at a level of -30 dBm at RX, RF and record - 1.RF frequency li ...

  • Philips TW0200 - page 25

    7-2.2 VSWR: - Voltage standing wave ratio Standing wave :- If the impedance of the load (Ant enna) and source ( Generator ) is not equal, that is not matching then part of the energy is reflected back towards the source., some power is absorbed and rest is reflected .this interference form one set of waves V & I traveling towards the load and r ...

  • Philips TW0200 - page 26

    177 ...

  • Philips TW0200 - page 27

    MSA Transmitter Fig. 7-10 Conversion chart of VSWR, Return Loss and SW R. VSWR Return loss In dB Reflection Coefficient SWR In dB 1.01 46.1 0.5 0.086 1.02 40.1 1.0 0.172 1.03 36.6 1.5 0.257 1.04 34.2 2.0 0.341 1.05 32.3 2.4 0.424 1.06 30.7 2.9 0.506 1.07 29.4 3.4 0.588 1.08 28.3 3.8 0.668 1.09 27.3 4.3 0.749 1.10 26.4 4.8 0.828 1.11 25.7 5.2 0.906 ...

  • Philips TW0200 - page 28

    179 ...

  • Philips TW0200 - page 29

    180 ...

  • Philips TW0200 - page 30

    Please see the W iltron diagram, Anritsu detector converts power into voltages. - Connect Open , select - Connect Short , select - Connect device , - Start select, - Function, - Max /select -20 dBm, - Min / select -34 dBm, - Cursor also move for max to minimum. Wiltron Generator: - See Fig. 7-1 2, 7-13. - Take 10.7 to 11.7 GHz - Level +10 dBm ( + 7 ...

  • Philips TW0200 - page 31

    182 . Check of BER with IF Loop: - oop IF Trans to If Receive and test 140 Mb/ STM-1 on DTA set for 0 PPM and ± 15 PPM. The result should be 0.00 E -11 5. a) Trans Branching Filter loss: - The difference between Trans Power at PA out and antenna port will be a Trans Branching Filter loss. b) Receive Filter loss: - Feed RF Frequency at a nominal le ...

  • Philips TW0200 - page 32

    7-2.4 HOP A/T OF 11 GHz 140 Mbps or STM-1 1] Receive level : - Note down Surveyed level, Nom inal level and measure Rx RF level at Rx IN by power meter with suitable sens or and pad by removing the W/G from RF IN. m - The same Rx RF l evel can be eas ured with calibrated spectrum analyzer and by ed een survey ed and nominal level should be within ? ...

  • Philips TW0200 - page 33

    4] BER measurement:- - Ask distant station loop on 140 Mb or STM-1 which is installed. - Carry out BER Test as usual for 0 and ± 15/20 PPM. - Take out printout for each channel/PPM , - Limit: - 1x 10 E -11 5] i Carr on channels for the following freq Filters as HP-1+LP & HP-2 +LP. o ± 15 or 20 PPM t 0 PPM, note down the ber 8] Check of ORDER ...

  • Philips TW0200 - page 34

    which transmits and receives Radio sig nals agnetic waves. Antenna used for the transmission of Radio, TV, , GSM and CDMA network. y in all direction) nal antenna of array of dipoles. - Parabolic: - It is made up of 2 to 4 meter diameter nd its components are Reflector, Feed, Support (Tie beam) ----------------- ------------- Or ------------ Λ (Wa ...

  • Philips TW0200 - page 35

    7-3.2 3. Link Budget:- Link budget is to calcula Receive level taking into consideration all gains and losses in the ne rk. It accounts atte nuation of transm itted FL – Br Where ns. not for at antenna port. e.g. Free space loss = 20 log FD + 92.4 = 144.60 dB Meter.) 91.20 dB 30.0 dBm Calculated Receive le vel = - 36.52 dBm ith thick blanket in d ...

  • Philips TW0200 - page 36

    7-3.3 5. Fresnel zone: - No. of concentric ellipsoid revolutions whic h defines volumes in radiation pattern of ircular aperture and it is due to diffraction by circular aperture ar in cross s ection and concentric near th e path of radio beam. TR – Direct path and TAR – ary transmission path eflection of M/W energy from A. in radio system fadi ...

  • Philips TW0200 - page 37

    -3.4 8. Rain attenuation: - As the water droplets scatters and absorb s radiation the effect of es on increasing with the increase of fr equencies i.e. it is more in 13 GHz system GHz stance likely size of rain cell i.e. by space diversity. in 1+1 traffic, called es, cost of the version of the same signal are transm itted at different time instance ...

  • Philips TW0200 - page 38

    Antenna diversity: - In this diversity sc hem microwave signals are transmitted along st instantaneously on failure of 11 Thi for ove 1. B 2. Frame Synch loss when BER >10 3. CMI O/P to Mux is lost Here Priority is 3>2>1 Process:- - Fault in reg annel detected at receiving end. - Faulty cha l switching control is tr ansmitte received end t ...

  • Philips TW0200 - page 39

    13. Wayside dropping: - If any small station in any hop requires 2 MB stream, an additional card is provided in system so as to handle th e traffic of small station along with main M/W system. fferential Absolute Delay Equalizer. It is to adjust the phase difference between signals received through 15. ATPC: - Automatic Trans Power Control. ATPC fa ...

  • Philips TW0200 - page 40

    7-4 2 GHz / 8 MB D/ UHF System A/T Make: - ARM-2208-M3 Specification: - 7-4.1 - Frequency band 2.0 to 2.3 GHz. range 45 dBm for threshold. - Ref Rec. I/P level -42 dBm ± 1 dBm. - Overload of LNA -35 dBm or better. Bm at Rx In. - O/W response ± 2 dBm. 7 nal level, the deviation should not be more than ± 3 dBm. - Mostly towers are existing but whe ...

  • Philips TW0200 - page 41

    192 ...

  • Philips TW0200 - page 42

    - Disconnect RF cable from Rx In. - Make a test set up as above for AGC calibration. - Select RF frequency and level say -40 dB m and calibrate it for the correct O/P level. - Put ON RF O/P and monitor AGC voltage. - Note down AGC voltage up to -75 dBm in steps of -10 dBm and there after in 5 dBm steps when E -3 LED lights. - Reading will be -86 to ...

  • Philips TW0200 - page 43

    7-4.4 HOP/ through A/T 1. Receive level: - - Measure RF Rx level at Rx IN a nd compare it with surveyed level. Deviat - ion between surv eyed and measured le vel should be within ±1 dBm. 5 minutes each. n: - m distant station. - r channel. as been switched to Same observe by making receiver off. - d ask other end to observe protection switching. - ...

  • Philips TW0200 - page 44

    - Tele command status TC1, TC2 OFF. - supervisory card out. - ous alarm on Transm itter . - / front pane l synthesizer go es 0/0 lock. ecovered. arranging loop from other station. % DM 0.045 7-4.5 C ial Feeder. /8 coaxial Cu 50 Ω . 9.1 mm. 28.9 mm er. 6. BITE Alarms: - - Eqpt fail: - Any Eqpt failure. - System fail: - Any System failure. Micropro ...

Manufacturer Philips Category Microwave Oven

Documents that we receive from a manufacturer of a Philips TW0200 can be divided into several groups. They are, among others:
- Philips technical drawings
- TW0200 manuals
- Philips product data sheets
- information booklets
- or energy labels Philips TW0200
All of them are important, but the most important information from the point of view of use of the device are in the user manual Philips TW0200.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Philips TW0200, service manual, brief instructions and user manuals Philips TW0200. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Philips TW0200.

Similar manuals

A complete manual for the device Philips TW0200, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Philips TW0200 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Philips TW0200.

A complete Philips manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Philips TW0200 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Philips TW0200, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Philips TW0200, that we can find in the current document
3. Tips how to use the basic functions of the device Philips TW0200 - which should help us in our first steps of using Philips TW0200
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Philips TW0200
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Philips TW0200 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Philips TW0200?

Use the form below

If you did not solve your problem by using a manual Philips TW0200, ask a question using the form below. If a user had a similar problem with Philips TW0200 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)