Manual Agilent Technologies 16440A SMU

28 pages 0.37 mb
Download

Go to site of 28

Summary
  • Agilent Technologies 16440A SMU - page 1

    User ’ s Guide Agilent 16 440A SMU/P ulse Ge nerato r Selec tor Agilent Part No. 16440-900 00 Printed in Japan January 2000 Edition 4 ...

  • Agilent Technologies 16440A SMU - page 2

    2 A gilent 16440A User ’s Guide, Edition 4 Legal Notice The information con tained in this docum ent is subject to chang e with out notice. Cop yrigh t © 1 994 - 2 00 0 Agil ent T ech nolo gie s This document contai ns inform ation w hich is protected by copyrig ht. All righ ts are reserved. Reproduction, adaptation, or translation with out prio ...

  • Agilent Technologies 16440A SMU - page 3

    A gilent 16440A Us er ’ s Guide, E dition 4 3 T o the extent allowed by local law , the above warranties are excl usive and no other warrant y or condition, w heth er written or oral, is expressed or implied an d Agilen t T echnologies specifically disclaim an y im plied warranties or conditions of merchan tability , sat isfactory qualit y , and ...

  • Agilent Technologies 16440A SMU - page 4

    4 A gilent 16440A User ’ s Guide, Edition 4 • GROUND THE INSTRUMENT This is Safety Class I instrum ent. T o min imize sh ock hazard, the instrum ent chassis and cabinet m ust be connected to an electrical g round. T he pow er terminal an d the power cable mu st meet Int ernational Electrotechnical Comm ission (IEC) safet y standards. • DO NOT ...

  • Agilent Technologies 16440A SMU - page 5

    A gilent 16440A Us er ’ s Guide, E dition 4 5 • Safety Symbols The general definitions of safety s ym bols used on equipmen t or in manu als are listed below . Instruction m anual sy m bol: the product will be m arked with this sy mbol w hen it is necessary for the user to refer to the instruct ion manu al in order to protect against dam age to ...

  • Agilent Technologies 16440A SMU - page 6

    6 A gilent 16440A User ’ s Guide, Edition 4 • Herstellerbescheinigung GE Ä USCHEMISSION Lpa < 70 dB am A rbeitsplatz normaler Betrieb nach DIN 45635 T . 19 • Manufactur er’s Declara tion ACOUSTIC NOISE EMISSION Lpa < 70dB operator po sition normal operation per ISO 7779 Printing History Edition 1: February 1994 Edition 2: April 1995 ...

  • Agilent Technologies 16440A SMU - page 7

    A gilent 16440A Us er ’ s Guide, E dition 4 User's Guide ...

  • Agilent Technologies 16440A SMU - page 8

    2 A gilent 16440 A User ’ s Guide, E dition 4 User's Guide Agilen t 16440A SMU/Pulse Generator Selector is one of the accessories available for Agilent 4155/41 56 Semiconduct or Parameter Analy zers. T he select or is for automaticall y sw itching the unit (SMU or PGU) that is connected to a DUT pin according to the state (stress force state ...

  • Agilent Technologies 16440A SMU - page 9

    A gilent 16440A Us er ’ s Guide, E dition 4 3 User's Guide Introduction Introduction The 16440 A selector contains the follow ing accessories: NOTE Inspecting the 16440A upon Receiving When the 16440A arrives at you r site, make su re that nothing is miss ing or damaged. Unpack the carton , then check the contents agai nst figu re and table ...

  • Agilent Technologies 16440A SMU - page 10

    4 A gilent 16440 A User ’ s Guide, E dition 4 User's Guide Operation Operation This section describes the operating theory of the selector . Agilen t 4155/4156 can control the s elector to automatically sw itch th e unit (SMU or PGU) that is connected to a DUT pin according to the state (stress force state or measu rement state). This is use ...

  • Agilent Technologies 16440A SMU - page 11

    A gilent 16440A Us er ’ s Guide, E dition 4 5 User's Guide Oper ation The following figure sh ows a sim ple circuit diagram of the selector (selector expander). The CH 1 and CH 3 circuits are different from the C H 2 and CH 4 circuits. Each channel has one mechan ical relay for SMU and one m echanical relay for PGU, but the CH 1 and CH 3 cir ...

  • Agilent Technologies 16440A SMU - page 12

    6 A gilent 16440 A User ’ s Guide, E dition 4 User's Guide Operation The switchi ng state of a channel is in dicated by the green LEDs on the selector front panel. The follow ing table show s the relation of th e relays and the LE Ds for each swit ching state. The "P GU open" state is usefu l if a lot of sw itching needs to be perf ...

  • Agilent Technologies 16440A SMU - page 13

    A gilent 16440A Us er ’ s Guide, E dition 4 7 User's Guide Installation Installation This section describes how to attach the selector to Agil ent 16442A test fixture or to a shielding box, and how to connect it to Ag ilent 4155/415 6. T o Attach the Sel ector to T est Fixture Y ou can attach your selector to the 16442A test fix ture. Y ou n ...

  • Agilent Technologies 16440A SMU - page 14

    8 A gilent 16440 A User ’ s Guide, E dition 4 User's Guide Installation The following steps apply w hen usi ng tw o selectors: 5. Place the second selector on your workbench . Place the selector and the test fixture on top of the secon d selector . 6. Position a plate on both si des. 7. Attach each plate usi ng the three fl athead screws s u ...

  • Agilent Technologies 16440A SMU - page 15

    A gilent 16440A Us er ’ s Guide, E dition 4 9 User's Guide Installation If you u se the 16441A R-box, attach the R- Box to the selector as show n below: ...

  • Agilent Technologies 16440A SMU - page 16

    10 A gilent 16440A Use r ’ s Guide, E dition 4 User's Guide Installation T o Attach the Sel ector to Shielding Bo x Y ou can attach your selector to a shielding box. Y ou need a standard screw driver . The following figure sh ows the s pacing of the 16440A screw holes. Y ou n eed to prepare four screws and nu ts to match th e screw holes . ...

  • Agilent Technologies 16440A SMU - page 17

    A gilent 16440A Us er ’ s Guide, E dition 4 1 1 User's Guide Installation If you u se two selectors, connect selectors before attaching to the sh ielding box, as show n below: 1. Place the selector on your w orkbench. 2. Place the second selector on top of the selector . 3. Position a plate on both si des. 4. Attach each plate usi ng the thr ...

  • Agilent Technologies 16440A SMU - page 18

    12 A gilent 16440A Use r ’ s Guide, E dition 4 User's Guide Installation Attach the s elector to the shielding box as sh own below : 1. Attach an ang le bracket to each side of the selector , using th e screws s upplied. 2. Place the selector(s) on the side panel of the sh ield ing b ox. 3. Position four nuts on the in side panel of the sh i ...

  • Agilent Technologies 16440A SMU - page 19

    A gilent 16440A Us er ’ s Guide, E dition 4 13 User's Guide Installation If you u se the 16441A R-box, attach the R- Box to the selector on the shielding box as show n below: ...

  • Agilent Technologies 16440A SMU - page 20

    14 A gilent 16440A Use r ’ s Guide, E dition 4 User's Guide Installation Connecting the Selector to the 4155/ 4156 • Connecting two selectors If you us e two selectors, connect the Control Output term inal of the selector to the Control Input term inal of the second selector us ing a 40 cm control cable as show n below . ...

  • Agilent Technologies 16440A SMU - page 21

    A gilent 16440A Us er ’ s Guide, E dition 4 15 User's Guide Installation • Connecting the selector to the 4155/41 56 T urn off the 4155/415 6 and 41501 before c onnecting the instrum ents. Then connect as show n below . 41501 4155/4156 16442A Test Fixture 16440A Selector 1 2 3 4 Inst rum ent T ermin al 16440A Te r m i n a l Cable 41501 T o ...

  • Agilent Technologies 16440A SMU - page 22

    16 A gilent 16440A Use r ’ s Guide, E dition 4 User's Guide Maintenan ce Maintenance This section provides the follow ing m aintenan ce information : • Cle aning • Servicing Cleaning the Selector T o maintain hig h performa nce, the selector must be kept clean. Oil, perspiration, hair , dust, and dirt will degrade the board insu lation, ...

  • Agilent Technologies 16440A SMU - page 23

    A gilent 16440A Us er ’ s Guide, E dition 4 17 User's Guide Maintena nce Circuit Block D iagram ...

  • Agilent Technologies 16440A SMU - page 24

    18 A gilent 16440A Use r ’ s Guide, E dition 4 User's Guide Maintenan ce Repl aceab le Pa rts When soldering, use low hy drochloric acid solder (Agilen t part num ber: 8090-0433) to prevent the flux in the solder from spreading unnecessarily, and make sure that adjacent terminals are not bridged. A fter soldering, m ake sure that there are n ...

  • Agilent Technologies 16440A SMU - page 25

    A gilent 16440A Us er ’ s Guide, E dition 4 19 User's Guide Maintena nce R13 0698-0085 Resistor 2.61 k W , 1% R15 0757-0279 Resistor 3.16 k W , 1% CR1 1901-0050 Diode CR2 1901-0050 Diode CR3 1901-0050 Diode CR4 1901-0050 Diode L1 9140-0210 Inductor 100 m H ±5% C1 0180-3468 Capacitor 47 m F 50 V CP1 1990-1625 Opto-isolator CP2 1990-1625 Opto ...

  • Agilent Technologies 16440A SMU - page 26

    20 A gilent 16440A Use r ’ s Guide, E dition 4 User's Guide Specifications Specifications The "supplemental inf ormation" and "typical" entries, in the f ollowing specifications are not w arranted, but provide useful informat ion about the functions and performance of th e instrum ents. The following specifications data i ...

  • Agilent Technologies 16440A SMU - page 27

    A gilent 16440A Us er ’ s Guide, E dition 4 21 User's Guide Specifications • Accessories (fu rnished). See Section 1 for details. • Option 001 • 1.5 m control cable (Agilent part nu mber 04155-61612) • 40 cm triaxial cable (Agi lent part num ber 04155 -61605) • Option 002 • 3.0 m control cable (Agilent part nu mber 04155-6161 1) ...

  • Agilent Technologies 16440A SMU - page 28

    22 A gilent 16440A Use r ’ s Guide, E dition 4 User's Guide Specifications Supplemental Informati on The following reference data is specified at 23 ± 5 ° C (73 ± 9 ° F) and 50 % relative hum idity . • SMU channel Leakage current less than 100 fA at 100 V Residual resistance 0.2 W typical S tray capacitance (for ce comm on) 0.3 pF typi ...

Manufacturer Agilent Technologies Category Sander

Documents that we receive from a manufacturer of a Agilent Technologies 16440A SMU can be divided into several groups. They are, among others:
- Agilent Technologies technical drawings
- 16440A SMU manuals
- Agilent Technologies product data sheets
- information booklets
- or energy labels Agilent Technologies 16440A SMU
All of them are important, but the most important information from the point of view of use of the device are in the user manual Agilent Technologies 16440A SMU.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Agilent Technologies 16440A SMU, service manual, brief instructions and user manuals Agilent Technologies 16440A SMU. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Agilent Technologies 16440A SMU.

A complete manual for the device Agilent Technologies 16440A SMU, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Agilent Technologies 16440A SMU by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Agilent Technologies 16440A SMU.

A complete Agilent Technologies manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Agilent Technologies 16440A SMU - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Agilent Technologies 16440A SMU, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Agilent Technologies 16440A SMU, that we can find in the current document
3. Tips how to use the basic functions of the device Agilent Technologies 16440A SMU - which should help us in our first steps of using Agilent Technologies 16440A SMU
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Agilent Technologies 16440A SMU
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Agilent Technologies 16440A SMU in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Agilent Technologies 16440A SMU?

Use the form below

If you did not solve your problem by using a manual Agilent Technologies 16440A SMU, ask a question using the form below. If a user had a similar problem with Agilent Technologies 16440A SMU it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)