    Installation Guide Remo vable P o w er Supply and F an A T -PWR01 A T -PWR02 A T -PWR05 A T -F AN01 A T -F AN03 ...

  • Allied Telesis AT-FAN01 - page 2

    Remo vable P o wer Suppl y and F an Installation Guide AT - P W R 0 1 AT - P W R 0 2 AT - P W R 0 5 AT - F A N 0 1 AT - F A N 0 3 Download the complete document set fr om www .alliedtelesis.com/suppor t/software ...

  • Allied Telesis AT-FAN01 - page 3

    Removable P ow er Supply and Fan 2 Removable P ower Supply and Fan Installatio n Guide Document Number C613-04057-00 REV L © 2008 Allied T elesis, Inc. All rights r eserved. No part of this publication ma y be repr oduced wit hout prior written permissi on fro m Allied T elesis, Inc. Allied T elesis, Inc. reserves the right to change specification ...

  • Allied Telesis AT-FAN01 - page 4

    Installation Guide 3 Contents About this Guide ........................................... ..................... .................... .......................... 4 Compatible Switches .............................................. ..................... .................... ................ 4 Package Contents ........... ..................... ....... ...

  • Allied Telesis AT-FAN01 - page 5

    Removable P ow er Supply and Fan 4 About this Guide This Installation Guide de scribes how to install the f ollowing PSUs and fans: ■ A T -PWR01 PSU , either A C or DC power suppl y unit ■ AT - P W R 0 2 P S U , A C o n l y ■ AT - P W R 0 5 P S U , A C o n l y ■ A T -F AN01, fan-only module ■ A T -F AN03, chassis fan module Compatible Swi ...

  • Allied Telesis AT-FAN01 - page 6

    Installation Guide 5 P acka ge Contents Depending on the model, switches are shipp ed with a single supply unit (PSU), either A C or DC . Some models also ha v e fan-onl y modules (FOM), chassis f an modules, or blanking plates. ■ The A T -8948, A T -9924Ts, x900-24XT , x900-24XT-N, and x900-24XS switches ha ve a PSU and a FOM installed. ■ The ...

  • Allied Telesis AT-FAN01 - page 7

    Removable P ow er Supply and Fan 6 Installing a P o wer Suppl y Unit or F an Use these instructions to install PSUs, chassis fan mo dules and FOMs. ■ Do not combine PWR01 and PWR02 PSUs in the sa me switch. ■ Do not combine A C and DC PSUs in the same switch. Befor e y ou begin ■ Read the safety information f or the switch. Safety inf ormatio ...

  • Allied Telesis AT-FAN01 - page 8

    Installation Guide 7 Installing a PWR01, PWR02, or F AN01 1. If you a re r eplacing a PSU, disconnect the po w er cord fr om the currently installed PSU befor e r emovin g it. For A C PSUs, turn off the main po w er sour ce to the PSU and disc onnect the pow er cord. For DC PSUs, push the Run/Standby contr ol and r elease it to the Off position. Wh ...

  • Allied Telesis AT-FAN01 - page 9

    Removable P ow er Supply and Fan 8 Installing a PWR05 or F AN03 1. If you a re r eplacing a PSU, turn off the main pow er sour ce to th e PSU and disconnect the pow er cor d befor e r emoving it. The DC eart hing connection is not necessar y for the SwitchBlade x908 when using A C PSUs because the ch assis is gr ounded t hr ough the p ow er cor ds. ...

  • Allied Telesis AT-FAN01 - page 10

    Installation Guide 9 Connecting an A C po w er suppl y Follow these instructions to connect an A T-PWR01, A T-PWR02, or A T-PWR05 A C PSU to an A C powe r supply: Wa r n i n g The A T-PWR01 A C PSU has a fuse rating of 2 50 V , 5 A for FH1 01 and FH102. Wa r n i n g The A T-PWR01 A C PSU has double pole/neutral fusing. Electric shock is possible si ...

  • Allied Telesis AT-FAN01 - page 11

    Removable P ow er Supply and Fan 10 3. Connect the po wer cord to the main po we r sour ce. 4. Check that the Run/Standby s witch is set to the Run position (1). Both the A C and DC LEDs should be lit. Note that when the Run/Standby switch is set to the Standby position (0), the A C LED lights and the fan spins, but the DC LED does not light and th ...

  • Allied Telesis AT-FAN01 - page 12

    Installation Guide 11 Connecting a DC po wer suppl y Follow these instructions to connect an A T-PWR01-80 DC PSU to a DC power supply . Only trained and qualified p erso nnel sh ould connect a DC pow er suppl y . Y ou need an appropriate DC po wer sour ce, DC supply cable, ring connectors, a crimp tool and an a ppr opriate scr ewdriver to tighten t ...

  • Allied Telesis AT-FAN01 - page 13

    Removable P ow er Supply and Fan 12 5. Ensure ther e ar e no exposed cable strands. 6. Replace the co ver . Y ou must replace the transparent plastic te rminal cover befor e contin uing. 7. Secur e the supply cabl e to the rack frame w ork or a similar object to ensur e that connections ar e iso lated fro m any f or ce a pplied to the cable. 8. Ens ...

  • Allied Telesis AT-FAN01 - page 14

    Installation Guide 13 Checking LEDs LEDs on PSUs, fans, and the fr ont panels o f switches in dicate the operationa l status of the devices. Aft er you ha ve installed a PSU or fan and ha ve po wer ed on the switch, c heck the LEDs to v erify operation by using the f ollowing tables. PWR01 PWR02 The follo wing table describes LEDs o n the PWR01 and ...

  • Allied Telesis AT-FAN01 - page 15

    Removable P ow er Supply and Fan 14 Switch The follo wing table describes how LEDs on the swi tch re port operations and faults with installed PSUs and FOMs. LED State Description PSU 1 and PSU 2 Green The PSU is installed and supplying po wer to the s witch. The vo ltage output is with in specification. Red One of the f ollowing: • The PSU is in ...

  • Allied Telesis AT-FAN01 - page 16

    Installation Guide 15 Remo ving a P o wer Suppl y Unit or F an Follow these instructions to remo ve a PSU , chassis fan module or FOM. Befor e y ou begin ■ Read the safety information f or the switch. Safety inf ormation is in the x900 Ser ies Switc h and Switc hBlade ® x908 Installation and Safety Guide . Y ou can download th is document fr om ...

  • Allied Telesis AT-FAN01 - page 17

    Removable P ow er Supply and Fan 16 T r oub leshooting If the PSU does not function as expected: ■ Check that all cable connections ar e corr ect and secur e. ■ On the PWR01 DC model, chec k that the Run/Standb y switch h as been presse d and is in the On position. ■ On the PWR05 A C model, check that the Run/Standb y switch has been set to R ...

  • Allied Telesis AT-FAN01 - page 18

    Installation Guide 17 Obtaining Documentation and Resour ces The complete docume nt set for x900 Series switches and SwitchBlade x908 includes: ■ this Installation Guide ■ the x900 Ser ies Switc h and Switc hBlade ® x908 Installation and Saf ety Guide , which describes ho w to install t he switch and includes important safety and statutor y in ...

  • Allied Telesis AT-FAN01 - page 19

    Removable P ow er Supply and Fan 18 A T -TFTP Ser ver for Windows is a TFTP ( T r ivial File T ransfer Pr otocol ) server for transferrin g softwar e v ersions, configurat ion scripts and other files betw een a PC and the switc h. Y ou download A T -TFTP Ser ver fr om www .alliedtelesis.com/support/softwar e . CD-R OM Some pr oducts also ship with ...

  • Allied Telesis AT-FAN01 - page 20

    Installation Guide 19 Standards Pr oducts in this document meet the follo wing standar ds: Category Appro val Agency and Requir ement UL60950-1 CAN/CSA-C22.2 No. 609 50-1-03 EN60950-1 AS/NZS 60950.1 Electr omagnetic Complia nce FCC CFR47 Part 15 Class A EN55022 Class A VCCI Clas s A AS/NZS CISPR22 Class A CNS 13438 Class A EN61000-3-2/ 3 Immunity E ...

  • Allied Telesis AT-FAN01 - page 21

    Removable P ow er Supply and Fan 20 EC Declaration of Conformity We : ALLIED TELESIS LABS LIMITED 27 NAZARETH A VENUE CHRISTCHURCH 802 4 NEW ZEALAND Declare unde r our sole legal responsibil ity that these pro ducts: A T -PWR01, A T -PWR01-80, A T -PWR02, and A T -PWR05 Po w er Supply Units Are in conformity w ith the essential r equir ements o f d ...

Manufacturer Allied Telesis Category Power Supply

Documents that we receive from a manufacturer of a Allied Telesis AT-FAN01 can be divided into several groups. They are, among others:
- Allied Telesis technical drawings
- AT-FAN01 manuals
- Allied Telesis product data sheets
- information booklets
- or energy labels Allied Telesis AT-FAN01
All of them are important, but the most important information from the point of view of use of the device are in the user manual Allied Telesis AT-FAN01.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Allied Telesis AT-FAN01, service manual, brief instructions and user manuals Allied Telesis AT-FAN01. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Allied Telesis AT-FAN01.

A complete manual for the device Allied Telesis AT-FAN01, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Allied Telesis AT-FAN01 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Allied Telesis AT-FAN01.

A complete Allied Telesis manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Allied Telesis AT-FAN01 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Allied Telesis AT-FAN01, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Allied Telesis AT-FAN01, that we can find in the current document
3. Tips how to use the basic functions of the device Allied Telesis AT-FAN01 - which should help us in our first steps of using Allied Telesis AT-FAN01
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Allied Telesis AT-FAN01
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Allied Telesis AT-FAN01 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Allied Telesis AT-FAN01?

Use the form below

If you did not solve your problem by using a manual Allied Telesis AT-FAN01, ask a question using the form below. If a user had a similar problem with Allied Telesis AT-FAN01 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)