Manual Uniden BC 235XLT

37 pages 1.6 mb
Download

Go to site of 37

Summary
  • Uniden BC 235XLT - page 1

    TABLE OF CONTENTS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 What is Scanning? . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 What is Searching? . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Types of Communications . . . . . . . . . . . . . . . . . . . . . 3 Feature Highlights . . . . . . . ...

  • Uniden BC 235XLT - page 2

    Introduct i on The BC 235XLT is a brand new state-of-the-art information radio with automatic scanning capabilities. It can store frequencies such as police, fire/emergency, marine, air, amateur, and other communications into 10 banks of 30 channels each. And you can scan all 300 channels at super fast Turbo Scan speed. With the BC 235XLT , you can ...

  • Uniden BC 235XLT - page 3

    Types of Communications Monitor communications such as: Police and fire department (including rescue and paramedics) NOAA weather broadcasts (preprogrammed channels) Business/industrial radio Motion picture and press relay Utilities Land transportation frequencies, such as trucking firms, buses, taxis, tow trucks, and railroads Marine and amateur ( ...

  • Uniden BC 235XLT - page 4

    Feature Highlig hts 30 Channels – Program one frequency into each channel. You must have at least one channel programmed to use the Scan mode. 29 MHz-512 MHz – Search these frequency ranges with your scanner. (The frequency coverage is not totally continuous from 29 MHz to 512 MHz.) Chain Searching – You can define five different personal sea ...

  • Uniden BC 235XLT - page 5

    Where to Obtain More Info r mati o n Before using your scanner, you must program frequencies into available channels. The Betty Bearcat Starter Frequency Guide lists typical frequencies used around the U.S.A. and Canada that you may program into your new scanner. If the frequencies listed in the starter guide do not work in your area, call the encl ...

  • Uniden BC 235XLT - page 6

    Included with Your Scanner If any of these items are missing or damaged, immediately contact your place of purchase or Uniden Customer Service at: (800) 297-1023, 8:00 a.m. to 5:00 p.m., Central, Monday through Friday. Rubber Antenna (A T218) Belt Clip with Screws (BCK150) AC Adapter (AD70U) Betty Bearcat Star ter F requency Guide Other Printed Mat ...

  • Uniden BC 235XLT - page 7

    Setu p These are helpful guidelines when using your new scanner: If your scanner receives interference or electrical noise, move the scanner or its antenna away from the source. If you need to improve reception, use an optional antenna designed for multi-band coverage.(You can purchase this type of antenna at a local electronics store.) Use the inc ...

  • Uniden BC 235XLT - page 8

    3. Replace cover and press down until it clicks into place. Warning: Do not mix alkaline batteries with Ni-Cd Batteries. Be sure to install four batteries of the same type. AC Adapter/Charger Use the AC Adapter/Charger to power the BC 235XLT from an AC outlet. Charging Warning Do not charge alkaline batteries in this scanner. Doing so may cause ser ...

  • Uniden BC 235XLT - page 9

    Adapter Safety Feature The AC Adapter included with this scanner may be equipped with a polarized line plug — a plug with one blade wider than the other. This plug will fit into the power outlet only one way. If you are unable to insert the plug fully into the outlet, try reversing the plug. Flexible Antenna Belt Clip Attach the flexible antenna ...

  • Uniden BC 235XLT - page 10

    Basic Operation Note: You can fold out the Front Cover to see the Controls and Indicators while reading this Guide. Setting the Squelch To set the Squelch, you must be in the Manual Mode. No signal should be present when adjusting squelch. 1. Press M until you do not hear a signal. 2. Adjust VOLUME to a comfortable listening level. 3. Think of the ...

  • Uniden BC 235XLT - page 11

    4. Turn SQUELCH fully clockwise until you hear a hiss. This lowers the “Squelch Gate” so that everything gets through—noise, weak signals, and strong signals. 5. Turn SQUELCH back counter-clockwise just until the hiss stops. Now the “Squelch Gate” allows only strong signals through. Strong Signals Medium Signals Weak Signals Noise PHONE S ...

  • Uniden BC 235XLT - page 12

    Keylock Key Lock prevents accidental key entries during scanning. 1. To lock the keypad, press and hold K until the key symbol appears. 2. To unlock the keypad, press and hold K until the key symbol disappears. 12 ...

  • Uniden BC 235XLT - page 13

    Pro gramm in g Before the BC 235XLT can receive radio broadcasts, you must program a frequency into at least one channel. Before scanning, repeat this procedure for each channel you program. 1. Select frequencies from your starter guide. 2. Press M . 3. Select a channel. a. Enter the channel number. b. Then press M . 13 ...

  • Uniden BC 235XLT - page 14

    4. Enter the frequency. a. Enter the frequency number. b. Then press E . Note: To clear a mistake while entering the frequency, press B twice, and start over. If the frequency entered is outside the Frequency Range of the scanner, a distinctive beep sounds. (See the Table on page 3 or the Band List on the back of the scanner). Press and go back to ...

  • Uniden BC 235XLT - page 15

    Programming Tips Do not program a weather frequency into one of the channels, since weather channels transmit continuously. Use for weather information. Group similar frequencies into adjacent channels. For example, program police frequencies in channels 1 through 10 and fire/emergency into channels 11 through 20, and so on. Put the frequency that ...

  • Uniden BC 235XLT - page 16

    Scanning When you turn on the power, the BC 235XLT automatically starts in the Scan mode. During normal scanning the scanner skips unprogrammed or locked out channels. When a transmission is received, the Scanner stops on that channel. When the transmission ends, scanning resumes automatically after two seconds. To stop on a channel during scanning ...

  • Uniden BC 235XLT - page 17

    Channel Lockout You can lockout any channel so it is not reviewed during normal scanning. You can restore the channel to scanning whenever you wish. Lockout in Manual Mode 1. Press . 2. Select a channel. a. Enter the channel number. b. Then press again. 3. Press to lockout the channel. 17 ...

  • Uniden BC 235XLT - page 18

    Locking a Channel While Scanning If the scanner keeps stopping on a particular channel due to noise or too frequent transmissions, you may want to keep that channel from scanning. 1. Wait until the scanner stops at the channel. 2. Then press . 3. The scanner immediately resumes scanning because the locked out channel is no longer in the scanning se ...

  • Uniden BC 235XLT - page 19

    Restore a Locked Out Channel 1. Press . 2. Select a locked out channel. a. Enter the channel number. b. Then press again. 3. Press to unlock the channel. 19 ...

  • Uniden BC 235XLT - page 20

    Restore All Locked-out Channels 1. Press . Note: You must be in Manual Mode before restoring all locked-out channels. 2. Press and hold for about two seconds. You will hear two beeps when all the channels have been restored. 20 ...

  • Uniden BC 235XLT - page 21

    Priority Scan When Priority Scan is turned on, your scanner checks the priority channel every two seconds for activity. If a signal is present on the priority channel, your scanner monitors the channel until the transmission ends, then resumes normal scanning. You can designate any of the 30 available channels as your Priority Channel. To activate ...

  • Uniden BC 235XLT - page 22

    Changing the Priority Channel You cannot eliminate the Priority Channel, but you can change it to any other of the 30 available channels. 1. Press . 2. Select a new Priority Channel. a. Enter the channel number. b. Then press again. 3. Press and hold for two seconds to designate this channel as your new Priority Channel. Two beeps indicate that the ...

  • Uniden BC 235XLT - page 23

    Chain Search Use Chain Search to find active frequencies in your area. You can search up to all five personal bands or turn off those bands you don’t want to hear. This gives you flexibility of searchin g for any channel between 29 and 512 MHz, as long as they are within the 10 frequencies bands covered by the BC60XLT-1 . See the table on page 3, ...

  • Uniden BC 235XLT - page 24

    To program a frequency range into one of the five personal Chain Search bands, follow these steps: 1. Press s until the search location you want appears in the display. 2. Enter lower limit of the search band. a. Enter the frequency number. b. Then press E . Note: The display alternates between the upper and lower ranges. 3. Enter upper limit of th ...

  • Uniden BC 235XLT - page 25

    Note: The display alternates between the upper and lower ranges. If you program the wrong limit, press 0 and E , then press 0 and E again to erase the error and reset the limits to zero. Then begin again. 4. Either press R to begin your search. Note: Your scanner searches each selected Personal Chain Search band. The display flashes the number of t ...

  • Uniden BC 235XLT - page 26

    5. To turn off a Chain Search band during search scanning, press its location number. For example, (a) if Chain Search locations 1 , 2 and 3 are selected, (b) press 3 to turn off band three so that it’s not scanned during your search. Search Hold Feature 1. Press U or D at anytime to stop the search. 2. Press U to move to the next higher frequenc ...

  • Uniden BC 235XLT - page 27

    Channel Skip If a particular channel continues to interrupt search scanning, it is possible to set your scanner to skip the frequency. If your scanner stops while searching, press N to lockout the frequency from the search range. Note: You can program 10 skip frequencies. The 11th skip frequency entered causes the 1st skip frequency to unlock. To u ...

  • Uniden BC 235XLT - page 28

    1. Press M . 2. Select a channel. a. Enter the channel number. b. Then press M again. 3. Select one or more of the personal search bands. For example, select CHAIN 2 . Note: These frequencies were used during “Setting a Search Range,” on page 23. 4. Press R . 5. When the scanner stops at the frequency you want, press either U or D . 28 ...

  • Uniden BC 235XLT - page 29

    Note: After this step you are in Search Hold mode. Press R to resume scanning. 6. Press E to store the frequency in the channel you selected. Note: After this step you are in manual mode. Repeat steps 2 through 6 for all the Search frequencies you want to store. Note: Remember that there are only 30 channels available to store frequencies, whether ...

  • Uniden BC 235XLT - page 30

    Weather Scan Your BC60XLT-1 is designed to scan 7 programmed NOAA frequencies, so you easily find your local NOAA weather broadcast. Note: It is not advisable to program a weather frequency into one of the 30 channels since weather channels transmit continuously. The scanner will remain on the weather channel, disrupting the scanning cycle. 1. Pres ...

  • Uniden BC 235XLT - page 31

    Care an d Maintenance General Use Turn the scanner off before disconnecting the power or replacing the batteries. Always write down the programmed frequencies in the event of memory loss. If memory is lost, simply reprogram each channel. The display shows 000.0000 in all channels when there has been a memory loss. Always press each button firmly un ...

  • Uniden BC 235XLT - page 32

    Repairs Do not attempt any repair. The scanner contains no serviceable parts. Contact the Uniden Customer Service Center or take it to a qualified repair technician. Birdies All radios can receive “birdies” (undesired signals). If your scanner stops during Scan mode and no sound is heard, it may be receiving a birdie. Birdies are internally gen ...

  • Uniden BC 235XLT - page 33

    Troubleshooting If your BC60XLT-1 is not performing properly, try the following steps. Proble m Sugges tion Scanner won’t work. 1. Chec k the connections at both ends of the AC Adapter. 2. Turn on the wall switch of your room. You could be using an outlet controlled by the wall switch. 3. Move the AC Adapter to another wall outlet or replace the ...

  • Uniden BC 235XLT - page 34

    Specifications Certified in accordance with FCC Rules and Regulations Part 15, Subpart C, as of date of manufacture. Channels : 30 (1 Bank) WX: 7 NOAA Weather Service Channels Search Bands: 10 Preprogrammed Bands 5 Programmable Chain Search Bands Frequenc y Range: 29.0–29.7 MHz 10 Meter Amateur Band 29.7–50 MHz VHF Low Band 50–54 MHz 6 Meter ...

  • Uniden BC 235XLT - page 35

    Accessories and Replacement Par ts Rubber Antenna (A T218) Belt Clip with Screws (BCK150) AC Adapter (AD70U) Monaur al Earph one 64 (EP009) Ω Cigarette Lighter P ower Cord (U A502) Hard-Wired P ower Cord (U A510) Betty Bearcat Star ter F requency Guide 35 ...

  • Uniden BC 235XLT - page 36

    One Year Limited Warranty Important: Evidence of original purchase is required for warranty service. WARRANTOR: UNIDEN AMERICA CORPORATION (“Uniden”) ELEMENTS OF WARRANTY: Uniden warrants, for one year, to the original retail owner, this Uniden Prod uct to be free from defects in materials and crafts manship with only the limitati ons or exclus ...

  • Uniden BC 235XLT - page 37

    Covered under one or more of the following U.S. patents: RE31,523 4,027,251 4,057,760 4,092,594 4,100,497 4,114,103 4,123,715 4,156,193 4,157,505 4,179,662 4,219,821 4,270,217 4,398,304 4,409,688 4,455,679 4,461,036 4,521,915 4,627,100 4,888,815 4,932,074 4,947,456 5,014,348 5,199,109 ©1995 Uniden America Corporation. All rights reserved. Printed ...

Manufacturer Uniden Category Scanner

Documents that we receive from a manufacturer of a Uniden BC 235XLT can be divided into several groups. They are, among others:
- Uniden technical drawings
- BC 235XLT manuals
- Uniden product data sheets
- information booklets
- or energy labels Uniden BC 235XLT
All of them are important, but the most important information from the point of view of use of the device are in the user manual Uniden BC 235XLT.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Uniden BC 235XLT, service manual, brief instructions and user manuals Uniden BC 235XLT. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Uniden BC 235XLT.

Similar manuals

A complete manual for the device Uniden BC 235XLT, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Uniden BC 235XLT by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Uniden BC 235XLT.

A complete Uniden manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Uniden BC 235XLT - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Uniden BC 235XLT, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Uniden BC 235XLT, that we can find in the current document
3. Tips how to use the basic functions of the device Uniden BC 235XLT - which should help us in our first steps of using Uniden BC 235XLT
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Uniden BC 235XLT
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Uniden BC 235XLT in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Uniden BC 235XLT?

Use the form below

If you did not solve your problem by using a manual Uniden BC 235XLT, ask a question using the form below. If a user had a similar problem with Uniden BC 235XLT it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)